Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reliability assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Development and Assessment of Deployed Sensors and Technologies Supporting Molten Salt Loop Operations

During FY24, Argonne conducted a variety of activities to develop and assess new monitoring and control technologies towards enabling long-duration operations of molten salt reactor systems. The first objective of the work completed this year was to deploy technologies capable of reliably and rapidly monitoring the operational health of a molten salt loop. To achieve this, the project focused on specific tasks, including: (1) electroanalytical technique development for use in deployed sensors, and (2) operations of sensors on the Facility to Alleviate Salt Technology Risks (FASTR) loop at Oak Ridge National Laboratory. The second objective of the work this year focused on creating a pumped actinide flow loop to enable long-duration salt chemistry and corrosion studies using uranium-bearing fuel salts. Toward that end, we designed and procured a loop capable of being installed into a radiological glovebox at Argonne. A corrosion control system was also designed for integration into this loop. These combined systems will enable the feasibility of corrosion control and management systems to be investigated with complex chloride fuel salt mixtures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rapid Detection of Anomalies in Battery Energy Storage System Data

Data analytics is pivotal in assessing the technical characteristics and performance of Battery Energy Storage Systems (BESS), underpinning BESS modeling, optimization, and control. However, raw datasets frequently harbor anomalies from measurement errors and equipment malfunctions, impacting BESS reliability and analysis accuracy To address the challenge, this paper presents a novel methodology for the rapid detection of anomalous charge or discharge cycles within BESS operational data, expediting the cleaning process while ensuring data integrity. We’ve collected diverse and comprehensive real-world BESS operational datasets in collaboration with the Electric Power Research Institute and multiple Washington State utilities. These datasets serve dual roles: enabling comprehensive data exploration and analysis for understanding underlying challenges and method development, while also acting as a vital validation resource, demonstrating practical effectiveness. The proposed method detects anomalies and aids in their resolution, improving system performance characterization precision. It also reveals recurring data anomaly sources, offering insights for data collection and handling enhancement. Practitioners can gain valuable insights from the identified anomalous cycles in the real-world datasets along with the investigative process for root cause analyses and essential data cleaning steps.

Crawford, Aladsair J.↗

Reference Station Risk Assessment for Refueling Heavy-Duty Vehicles Using HyRAM+

The deployment of heavy-duty (HD) hydrogen fuel cell vehicles that are entering the market now is driving the need for expanded HD hydrogen refueling station infrastructure to meet demand. This expansion must prioritize safety and reliability, necessitating careful consideration of the associated risks. In this study, we use a light-duty (LD) hydrogen refueling station as a comparative tool to quantify the risks for a HD station, which is essentially a scaled-up version of a LD station.

08 HYDROGEN↗

An Evaluation of Sustainable Power System Resilience in the Face of Severe Weather Conditions and Climate Changes: A Comprehensive Review of Current Advances

Natural disasters pose significant threats to power distribution systems, intensified by the increasing impacts of climate changes. Resilience-enhancement strategies are crucial in mitigating the resulting social and economic damages. Hence, this review paper presents a comprehensive exploration of weather management strategies, augmented by recent advancements in machine learning algorithms, to show a sustainable resilience assessment. By addressing the unique challenges posed by diverse weather conditions, we propose flexible and intelligent solutions to navigate disaster complications effectively. This proposition emphasizes sustainable practices that not only address immediate disaster complications, but also prioritize long-term resilience and adaptability. Furthermore, the focus extends to mitigation strategies and microgrid technologies adapted to distribution systems. Through statistical analysis and mathematical formulations, we highlight the critical role of these advancements in mitigating severe weather conditions and ensuring the system reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiscale assessment of North American terrestrial carbon balance

Abstract. Comparisons of carbon uptake estimates from bottom-up terrestrial biosphere models (TBMs) to top-down atmospheric inversions help assess how well we understand carbon dioxide (CO2) exchange between the atmosphere and terrestrial biosphere. Previous comparisons have shown varying levels of agreement between bottom-up and top-down approaches, but they have almost exclusively focused on large, aggregated scales (e.g., global or continental), providing limited insights into reasons for the mismatches. Here we explore how consistency, defined as the spread in net ecosystem exchange (NEE) estimates within an ensemble of TBMs or inversions, varies with at finer spatial scales ranging from 1∘×1∘ to the continent of North America. We also evaluate how well consistency informs accuracy in overall NEE estimates by filtering models based on their agreement with the variability, magnitude, and seasonality in observed atmospheric CO2 drawdowns or enhancements. We find that TBMs produce more consistent estimates of NEE for most regions and at most scales relative to inversions. Filtering models using atmospheric CO2 metrics causes ensemble spread to decrease substantially for TBMs, but not for inversions. This suggests that ensemble spread is likely not a reliable measure of the uncertainty associated with the North American carbon balance at any spatial scale. Promisingly, applying atmospheric CO2 metrics leads to a set of models with converging flux estimates across TBMs and inversions. Overall, we show that multiscale assessment of the agreement between bottom-up and top-down NEE estimates, aided by regional-scale observational constraints is a promising path towards identifying fine-scale sources of uncertainty and improving both ensemble consistency and accuracy. These findings help refine our understanding of biospheric carbon balance, particularly at scales relevant for informing regional carbon-climate feedbacks.

54 ENVIRONMENTAL SCIENCES↗

Life Cycle Inventory Availability: Status and Prospects for Leveraging New Technologies

The demand for life cycle assessments (LCA) is growing rapidly, which leads to an increasing demand of life cycle inventory (LCI) data. While the LCA community has made significant progress in developing LCI databases for diverse applications, challenges still need to be addressed. This perspective summarizes the current data gaps, transparency, and uncertainty aspects of existing LCI databases. Additionally, we survey and discuss novel techniques for LCI data generation, dissemination, and validation. We propose key future directions for LCI development efforts to address these challenges, including leveraging scientific and technical advances such as the Internet of Things (IoT), machine learning, and blockchain/cloud platforms. Adopting these advanced technologies can significantly improve the quality and accessibility of LCI data, thereby facilitating more accurate and reliable LCA studies.

blockchain platforms↗

Rapid and high-throughput determination of sorghum ( Sorghum bicolor ) biomass composition using near infrared spectroscopy and chemometrics

Compositional characterization of biomass is vital for the biofuel industry. Traditional wet chemistry-based methods for analyzing biomass composition are laborious, time-consuming, and require extensive use of chemical reagents as well as highly skilled personnel. In this study, near-infrared (NIR) spectroscopy was used to quickly assess the composition of above-ground vegetative biomass from 113 diverse, photoperiod-sensitive, biomass-type sorghum (Sorghum bicolor) accessions cultivated under field conditions in Central Illinois. Biomass samples were analyzed using NIR spectra collected in the spectral range of 867–2536 nm, with their chemical compositions determined following the National Renewable Energy Laboratory (NREL) protocol. Advanced spectral pre-treatment and band selection techniques were utilized to develop calibration models using partial least squares regression (PLSR). The models’ effectiveness was assessed through cross-validation and independent data tests. The predictions for moisture, ash, extractives, glucan, xylan, acid-soluble lignin (ASL), acid-insoluble lignin (AIL), and total lignin were accurate and reliable, demonstrating the capability of NIR spectroscopy to provide rapid and precise characterization of sorghum biomass. The results demonstrated that NIR spectroscopy is an efficient tool for rapidly characterizing sorghum biomass, making it a sustainable option for screening desirable feedstock for biofuel or bioproduct production.

09 BIOMASS FUELS↗

Mine Water Use, Treatment, and Reuse in the United States: A Look at Current Industry Practices and Select Case Studies

Mining provides significant economic value while often impacting local water supplies and environments because of freshwater usage and waste disposal practices. In this paper we identify current practices in mine water, including how water is used in mining, influent and effluent water quality, treatment technologies, and end uses with the goal of informing future research on implementable, reliable, and cost-effective advanced water treatment in the mining sector. This study also reviews the available literature to broadly evaluate mining in the United States and performs a techno-economic assessment on water use and disposal for three detailed case studies applicable to lithium, uranium, and copper mines. These case studies highlight specific industry examples of distinct extraction methods, geographical regions, and mined commodities. Hypothetical scenarios based on case study baselines revealed potential impacts to mine water available for beneficial reuse through the use of novel water treatment technologies and alternate water management strategies. Finally, an assessment of national level impacts resulting from the reuse of treated mine source water is presented.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermal expansion of LaB 6 from 298 to 998 K

We propose LaB 6 as a temperature calibration standard for high-temperature (HT) X-ray diffractometry owing to its high temperature stability. Such HT applications require a reliable HT lattice parameter or, equivalently, peak position data, which have not been readily accessible to the diffraction community to date. As such, the thermal expansion behavior of NIST SRM 660a LaB6 was assessed in the temperature range 298–998 K using HT Bragg–Brentano parafocusing θ:θ X-ray diffractometry in conjunction with Rietveld analysis. Data were collected in the 2θ range 20–150° at a data collection rate of 0.5° θ min −1 in air and at 1 atm. The temperature was stepped in 50 K increments. The cubic unit-cell lattice parameter [a(T)] of LaB 6 in Å was found to vary as a(T) = 4.15678 (±0.00001) + Ξ(T − 298 K) + Ψ(T − 298 K) 2 , where Ξ = 2.4645 × 10 −5 (±4.8904 × 10 −8 ) Å K −1 and Ψ = 1.0325 × 10 −8 (±6.7376 × 10 −11 ) Å K −1 . The isobaric volume thermal expansion coefficient (TEC) was obtained as α V P = (5.9291 × 10 −6 ) + (4.9680 × 10 −9 )(T − 298 K) K −1 , from which the corresponding linear TEC was obtained as α L P = (1.9764 × 10 −6 ) + (1.6560 × 10 −9 )(T − 298 K) K −1 . The 3 × 3 matrix representations of the single-crystal isobaric linear TEC and the volume expansivity were obtained for the cubic crystal class to which LaB 6 belongs. Also, the temperature dependence of the lattice parameter data of this study was compared with past landmark studies on LaB 6 by Dutchak et al. [Inorg. Mater. (1972), 8, 1877–1880] and Aivazov et al. [Inorg. Mater. (1979), 15, 1015–1016].

LaB6 standard material↗

Developing VSC-HVDC Oscillation Damping Control Constraints in Unit Commitment

High-voltage direct current (HVDC) systems within the existing power grids will play a pivotal role in enabling high share of renewable power integration and transportation electrification. There is a need for transmission planning models to accurately capture the impact of VSC-HVDC oscillation damping control on the system planning and model the constraints in the security constrained unit commitment (SCUC) problem. In this paper, the SCUC problem in a hybrid DC-AC grid considering damping on electromechanical inter-area oscillation is studied. An electromechanical oscillation-driven transmission capability constraints are derived from system swing equation and incorporated into the SCUC. Multiple system damping control scenarios are set based on the extracted plausible bounds of damping coefficient and inertia constant to linearize the nonlinear expressions. The SCUC problem with proposed constraints is tested on the Reliability Test System Grid Modernization Lab Consortium (RTS-GMLC) via PLEXOS. The impact of the proposed constraints on regional generation, inertia, power flow, annual system cost, and renewable energy curtailment are fully assessed.

damping control↗

Data for Rapid and High-Throughput Determination of Sorghum ( Sorghum bicolor ) Biomass Composition using Near Infrared Spectroscopy and Chemometrics

Compositional characterization of biomass is vital for the biofuel industry. Traditional wet chemistry-based methods for analyzing biomass composition are laborious, time-consuming, and require extensive use of chemical reagents as well as highly skilled personnel. In this study, near-infrared (NIR) spectroscopy was used to quickly assess the composition of above-ground vegetative biomass from 113 diverse, photoperiod-sensitive, biomass-type sorghum ( Sorghum bicolor ) accessions cultivated under field conditions in Central Illinois. Biomass samples were analyzed using NIR spectra collected in the spectral range of 867–2536 nm, with their chemical compositions determined following the National Renewable Energy Laboratory (NREL) protocol. Advanced spectral pre-treatment and band selection techniques were utilized to develop calibration models using partial least squares regression (PLSR). The models’ effectiveness was assessed through cross-validation and independent data tests. The predictions for moisture, ash, extractives, glucan, xylan, acid-soluble lignin (ASL), acid-insoluble lignin (AIL), and total lignin were accurate and reliable, demonstrating the capability of NIR spectroscopy to provide rapid and precise characterization of sorghum biomass. The results demonstrated that NIR spectroscopy is an efficient tool for rapidly characterizing sorghum biomass, making it a sustainable option for screening desirable feedstock for biofuel or bioproduct production.

Biomass Analytics↗

Radiological Monitoring Plan for the Oak Ridge Y-12 National Security Complex: Surface Water

DOE Order 458.1 requires that dose estimates consider contributions from all facilities. In the Y-12 Radiological Monitoring Plan (RMP), surface water is monitored at points that reflect individual facilities, as well as at points that reflect the combined contributions of all facilities. This monitoring plan does not consider other potential routes (i.e., airborne releases and food chains). Thus, a complete determination of total effective dose (TED) cannot be made based on this plan alone. The other routes from Y-12, and all routes from other DOE facilities on the Oak Ridge Reservation (e.g., Oak Ridge National Laboratory (ORNL) and The Heritage Center), must be considered in order to satisfy DOE Order 458.1 requirements. Determination of TED from all sites and pathways is done through the use of dose-assessment models and is documented in the Annual Site Environmental Report. This monitoring plan provides adequate monitoring goals for Y-12 surface water releases to provide input of sufficient sensitivity and accuracy to reliably determine the Y-12 surface water component of the TED. The routine radiological monitoring program is designed to monitor effluents at four types of locations: (1) treatment facilities, (2) other point and area source discharges, (3) instream locations, and (4) production building roof run-off. With this sampling and analysis program, data will be obtained on primary point sources as well as on locations that represent the composite of other potential sources. This plan will be reviewed periodically to determine necessary modifications to the sampling frequencies, parameters, and locations. Modifications, if any, will be based on the analysis of the previous data and its effectiveness in satisfying the objectives of this plan. Appendix A contains graphs of the sum of the DCS fractions for locations and frequencies contained in a previous version of this plan. The data was collected from January 2009 through December 2019. Each sample was analyzed, and each result was divided by the appropriate DCS to compute a DCS fraction. These fractions were summed for all isotopes. According to DOE –STD-1196-2011, the annual average of these sums should be below 1.

54 ENVIRONMENTAL SCIENCES↗

Precursor Analysis Report: SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003

The SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003 Precursor Analysis Report leverages publicly available information about Davis-Besse’s 2003 cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 25 January 2003, the SQL Slammer worm infected more than 90% of vulnerable hosts and crashed the internet in 10 to 15 minutes, making it one of the fastest spreading worms in history. SQL Slammer is a fileless, memory-resident worm that remotely exploits a stack-based buffer overflow vulnerability on local hosts to intensively scan and rapidly self-propagate across the internet. The worm infected approximately 300,000 unpatched hosts running Microsoft Structured Query Language (SQL) Server 2000 or Microsoft Desktop Engine (MSDE) 2000 with SQL Server Resolution Service. The SQL Slammer worm indirectly infected FirstEnergy’s Davis-Besse nuclear power plant by first infecting a consultant’s company network server and then propagating through an external misconfigured connection into Davis-Besse’s site network. The infection caused major network congestion, slow performance, data overloads, and the inability of local hosts to communicate with each other, which eventually caused a loss of availability and a loss of view when the Safety Parameter Display System (SPDS) and Plant Process Computer (PPC) crashed. At the time of the infection, the plant was already offline, the digital monitoring systems had redundant analog backups, and the plant control and safety functions were not affected, so there were no concerns of a safety breach. However, this incident resulted in many lessons learned and spawned important discussions about cybersecurity’s role in nuclear safety and electric power reliability regulation, policy, and guidance. Researchers and analysts identified 10 unique techniques utilized during the attack with a total of 640 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Eight of the identified techniques used during Davis-Besse cyber attack were precursors to the triggering event. Analysis identified 596 observables associated with these precursor techniques, 428 of which were assessed to have an increased likelihood of being perceived in the 331 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Geometric Optimization of an Electrochemical Purification Cell to Prevent Corrosion in CSP Plants During Operation

When exposed to moisture or oxygen, molten chloride salts produce corrosive impurities which degrade containment alloys. As a result, this can significantly decrease the lifetime and increase costs of molten-salt-based systems. To overcome this barrier, we designed and modeled an electrochemical purification cell to remove the corrosive impurity MgOH+. Various reactor architectures, including constant stirred tank reactors (CSTRs) and plug flow reactors (PFRs) were investigated. Steady-state thermoelectric properties were evaluated, allowing assessment of the effects of structure and design parameters such as flow rate, cell length, and cross-sectional area of molten salt. The results suggest that our design could most effectively increase reliability and decrease costs of molten-chloride-salt-based systems by protecting them during continuous operation using an annular plug flow reactor.

chloride salts↗

Medium-Voltage Testbed for Comparing Advanced Power Line Sensors vs. Measurement Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medi-um-voltage sensor is compared with a reference PT and CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the US De-partment of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with integrator for current monitoring. The advanced outdoor power line sensor testbed has a real-time simulator that was used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, service restoration), while the analog signals were recorded by the same high resolution power meter. The behavior of analog signals, harmonic components, total harmonic distortion, and crest factors were assessed for this power line sensor compared with the reference PT/CT, because of the absence for testing standards for advanced outdoor power line sensors.

Piesciorovsky, Emilio↗

Risk Assessment in a Chemical Laboratory Following an Explosive Incident Involving a Novel Diazonium Compound: Retrospective Analysis and Lessons Learned

Diazonium compounds are synthetically useful in the production of dyes and textiles, however they are highly explosive under dry conditions. Explosion prevention becomes more difficult when new diazonium compounds are synthesized, because while some syntheses include a counterion to increase their stability, this is not always a reliable method to prevent an explosive incident. Due to the uncertainty surrounding the explosiveness of different diazonium compounds, it is important to understand how to safely clean up after an incident and how to determine when it is safe to return a laboratory to typical operational use, particularly when the incident involves a novel compound where a standard does not exist for instrument calibration. Here, an explosive event is discussed involving the synthesis of 4-bromo-benzenediazonium-2-carboxylate. Following the explosive incident and 3-step cleanup, which involved a precautionary neutralization step, samples were collected from the fume hood where the incident occurred. Because the incident involved an unstable, novel compound that is not commercially available and was deemed unsafe to resynthesize for instrument calibration, we assessed the risk of further explosion by analyzing for the stable decomposition products. Mass spectrometry analysis confirmed that the residue in the fume hood contained 5-bromosalicylic acid, a decomposition product of 4-bromo-benzenediazonium-2-carboxylate. Samples were taken from multiple points in the fume hood and analyzed to estimate the spatial distribution of the decomposition product. Based on this analysis, we inferred that the primary decomposition product was far more abundant than residual energetic, indicating the energetic had been consumed or neutralized to a trace quantity where the risk of further explosion was low. Furthermore, the steps presented here─specifically, initial neutralization and then analyzing the spatial distribution of expected decomposition products to assess risk when a novel explosive material is detonated in a confined space─were our approach to assess further risk following an explosion due to a novel diazonium compound without the need for any further handling or resynthesis of the energetic. Here, we present our approach and critically analyze these steps by discussing retrospective lessons learned and alternative analytical approaches.

Computer simulations↗

On the measurement of S diff splitting caused by lowermost mantle anisotropy

Seismic anisotropy has been detected at many depths of the Earth, including its upper layers, the lowermost mantle and the inner core. While upper mantle seismic anisotropy is relatively straightforward to resolve, lowermost mantle anisotropy has proven to be more complicated to measure. Due to their long, horizontal ray paths along the core–mantle boundary (CMB), S waves diffracted along the CMB (S diff ) are potentially strongly influenced by lowermost mantle anisotropy. S diff waves can be recorded over a large epicentral distance range and thus sample the lowermost mantle everywhere around the globe. S diff therefore represents a promising phase for studying lowermost mantle anisotropy; however, previous studies have pointed out some difficulties with the interpretation of differential SH diff –SV diff traveltimes in terms of seismic anisotropy. Here, we provide a new, comprehensive assessment of the usability of S diff waves to infer lowermost mantle anisotropy. Using both axisymmetric and fully 3-D global wavefield simulations, we show that there are cases in which S diff can reliably detect and characterize deep mantle anisotropy when measuring traditional splitting parameters (as opposed to differential traveltimes). First, we analyze isotropic effects on S diff polarizations, including the influence of realistic velocity structure (such as 3-D velocity heterogeneity and ultra-low velocity zones), the character of the lowermost mantle velocity gradient, mantle attenuation structure, and Earth’s Coriolis force. Secondly, we evaluate effects of seismic anisotropy in both the upper and the lowermost mantle on SH diff waves. In particular, we investigate how SH diff waves are split by seismic anisotropy in the upper mantle near the source and how this anisotropic signature propagates to the receiver for a variety of lowermost mantle models. We demonstrate that, in particular and predictable cases, anisotropy leads to S diff splitting that can be clearly distinguished from other waveform effects. Here, these results enable us to lay out a strategy for the analysis of S diff splitting due to anisotropy at the base of the mantle, which includes steps to help avoid potential pitfalls, with attention paid to the initial polarization of S diff and the influence of source-side anisotropy. We demonstrate our S diff splitting method using three earthquakes that occurred beneath the Celebes Sea, measured at many transportable array stations at a suitable epicentral distance. We resolve consistent and well-constrained S diff splitting parameters due to lowermost mantle anisotropy beneath the northeastern Pacific Ocean.

54 ENVIRONMENTAL SCIENCES↗