Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Observation of D 2 molecule line emission after massive D 2 injection into runaway electron plateaus in DIII-D

Molecular deuterium line emission is observed in both the visible and ultraviolet (UV) wavelength ranges after massive (> 100 Torr-L) injection of D 2 gas into post-disruption runaway electron (RE) dominated plasmas in the DIII-D tokamak. D 2 UV line emission is found to be the dominant source of radiated power, surpassing D Lyα. Interpretive modeling with a collisional-radiative model (CRM) indicates that D 2 radiation surpasses D radiation because Lyα is strongly trapped, while D 2 UV lines are mostly untrapped. The CRM also indicates that the D 2 line emission is completely dominated by RE impact (rather than thermal electron impact), so the D 2 line emission can serve as a good diagnostic for the spatial localization of REs. Analysis of D 2 visible lines indicates that the D 2 molecules in the plasma are thermally equilibrated with the background plasma, with vibrational, rotational, and kinetic temperatures all near 0.3 eV. D 2 spectroscopy therefore serves as a convenient diagnostic of background plasma temperature. As a result, measurement of D 2 radiated power also appears to serve as a useful diagnostic for constraining neutral transport modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Excessive charge, beam loading, and impedance collapse thresholds for a velvet emitter

Excess emission has been observed from velvet cathodes with total emission times >150 ns. In this diode experiment, we produce a sub-relativistic electron beam with the ability to consistently change γ from 1.2 to 1.5 and β = 0.5–0.75. Electron emission in this particular diode geometry requires electric fields >40 kV/cm. The current increases at steady rates >0.05 A/ns after the head of the pulse, indicating an expansion of the emission surface and reduction in the effective AK gap. Small transients of excess emission (or arcs) are consistently observed for current pulses exceeding 150 ns. The excess emission results in beam loaded levels ≥10 kV on the diode voltage. The effects described here are compounded as diode voltage is increased. The principal objective of these experiments is to quantify electric field emission thresholds, current ramps, excess emission delays, effective beam loading, and impedance collapse.

43 PARTICLE ACCELERATORS↗

Developing a robust sensor for infrared imaging bolometers

A new type of large area sensor for infrared imaging bolometers has been developed. It replaces the thin and fragile free-standing metal foils, which typically have been used, with a multi-layer coated sapphire (or diamond) substrate. Sapphire is transparent to mid-infrared wavelengths, is robust against transients, and can be thick enough to even be the vacuum window. The primary radiation absorber is still a thin deposited metal layer, but now it is partially insulated from the supporting sapphire substrate by a black (carbon-based) layer, which also acts as a blackbody remitter. Test results indicate 6× more noise equivalent power density (estimated NEPD = 23 W/m 2 at 5 ms camera exposure time, foil temperature decay time 60 ms) for a 2 μm gold-coated sapphire disk compared to estimated NEP = 4 W/m 2 at 1.8 ms exposure time, with foil decay time 420 ms, for a nominal 2.5 μm thick platinum-free-standing foil.

47 OTHER INSTRUMENTATION↗

Quantifying fission yields at the National Ignition Facility using depleted uranium foil experiments

There are programs for high-Z shell experiments at the National Ignition Facility (NIF). For shells made of actinide material, a quantitative fission diagnostic is needed in order to determine how much fission took place and whether the fission was sufficient to produce a non-negligible heat source in the burning capsule. Here, we present a viable coupled experimental and theoretical technique for making quantitative fission measurements possible. The proposed scheme involves using a well-characterized set of depleted uranium foils outside an NIF capsule to verify the conversion of xenon and krypton fission fragments collected at the Radiochemical Analysis of Gaseous Samples (RAGS) facility into total fission yield. We present the calculations needed for this conversion, including the decays in and out of fission fragment chains during the RAGS pump-down of the NIF chamber.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development and characterization of a laser-gated, high resolution x-ray radiography platform for high energy density experiments using toroidally bent crystals

Bent crystal x-ray imagers are a well-established diagnostic tool to study high energy density (HED) objects by acquiring two-dimensional x-ray radiographs. Often, studying these HED objects requires very high spatial resolution, which is limited by astigmatism when using spherically bent crystals. By using toroidal-shaped crystals instead, astigmatism can be reduced and the overall spatial resolution of the instrument improved. Here, the development and characterization of a laser-gated x-ray radiography platform at the National Ignition Facility using a toroidal crystal is presented. This includes measurements of the spatial and temporal profile, which is determined by the x-ray source. In conclusion, to properly validate the reduced astigmatism, a new multi-plane grid approach was implemented, which, for the first time, allows a depth of field measurement, alignment verification and x-ray source size estimate in a single shot, demonstrating the current platform’s capability to provide sub-10 μm resolution over a 0.9 mm depth of field with a temporal resolution of 110 ps.

Crystal optics↗

Measurement of near- and far-field impurity flows during pellet-induced rapid shutdown in DIII-D

Both near-field (<1 m away toroidally from the pellet) and far-field (>1 m away toroidally from the pellet) poloidal and toroidal impurity (carbon ion) flows are measured using visible imaging and fast bolometry during a polypropylene pellet-induced rapid plasma shutdown in the DIII-D tokamak. In the near field, the pellet appears to increase poloidal flow in the ion diamagnetic direction, possibly due to the strong radial temperature gradient caused by the pellet ablation. In the far field, the poloidal impurity flow typically appears slower and in the opposite direction. Toroidal impurity flow appears to be strongly influenced by the plasma initial toroidal rotation, especially in the far field. These results demonstrate that rapid shutdown impurity flows are not necessarily global in structure but can be quite different close to and far from the injected pellet.

Electromagnetic radiation detectors↗

Measurements of Single Event Upset in ATLAS IBL

Effects of Single Event Upsets (SEU) and Single Event Transients (SET) are studied in the FE-I4B chip of the innermost layer of the ATLAS pixel system. SEU/SET affect the FE-I4B Global Registers as well as the settings for the individual pixels, causing, among other things, occupancy losses, drops in the low voltage currents, noisy pixels, and silent pixels. Quantitative data analysis and simulations indicate that SET dominate over SEU on the load line of the memory. Operational issues and mitigation techniques are presented.

47 OTHER INSTRUMENTATION↗

Active Region Extent Assessment with X-rays (AREA-X)

The development of semiconductor sensors for new particle tracking detectors places increasing limits on sensor characteristics such as uniformity, size and shape of inefficient areas and size of active compared to inactive sensor areas. Accurately assessing these relatively subtle effects requires either measurements in particle beams or the modification of samples to be used in dedicated laser test setups. Active Region Extent Assessment with X-rays (AREA-X) has been developed as an alternative method for the fast, efficient and precise study of the active area of a semiconductor sensor. It uses a monochromatic, micro-focused X-ray beam with a 10–20 keV energy range as provided by several synchrotron beam lines and uses the photo current induced in the sensor to measure the depth of the responsive sensor volume. It can be used to study local inhomogeneities or inefficiencies, the overall extent of the active sensor volume and its shape and its localised application, which makes the need to gather statistics over a large area unnecessary, allowing for fast readout, which enables studies of the sensor behaviour at a range of external parameters, e.g. temperature or applied bias voltage. This paper presents the measurement concept and technical setup of the measurement, results from initial measurements as well as capabilities and limitations of the method.

47 OTHER INSTRUMENTATION↗

Analysis of humidity sensitivity of silicon strip sensors for ATLAS upgrade tracker, pre- and post-irradiation

During the prototyping phase of the new ATLAS Inner-Tracker (ITk) strip sensors, a degradation of the device breakdown voltage at high humidity was observed. Although the degradation was temporary, showing a fast recovery in dry conditions, the study of the influence of humidity on the sensor performance was critical to establish counter-measures and handling protocols during production testing in order to ensure the proper performance of the upgraded detector. The work presented here has the objective to study for the first time the breakdown voltage deterioration in presence of ambient humidity of ATLAS ITk production-layout strip sensors with different surface properties, before and after proton, neutron and gamma irradiations. A study of the humidity sensitivity of miniature ATLAS ITk strip sensors, before and after proton irradiations, is also presented to compare the sensitivity of devices with different sizes. The sensors were also exposed for several days to high humidity with the aim to recreate and evaluate the influence of the detector integration environment expected during the Large Hadron Collider (LHC) Long Shutdown 3 (LS3) in 2026, where the sensors will be exposed to ambient humidity for prolonged times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test beam performance of a CBC3-based mini-module for the Phase-2 CMS Outer Tracker before and after neutron irradiation

The Large Hadron Collider (LHC) at CERN will undergo majorupgrades to increase the instantaneous luminosity up to5–7.5×10$^{34}$ cm$^{-2}$s$^{-1}$. This High Luminosityupgrade of the LHC (HL-LHC) will deliver a total of3000–4000 fb$^{-1}$ of proton-proton collisions at acenter-of-mass energy of 13–14 TeV. To cope with thesechallenging environmental conditions, the strip tracker of the CMSexperiment will be upgraded using modules with two closely-spacedsilicon sensors to provide information to include tracking in theLevel-1 trigger selection. This paper describes the performance, ina test beam experiment, of the first prototype module based on thefinal version of the CMS Binary Chip front-end ASIC before and afterthe module was irradiated with neutrons. Results demonstrate thatthe prototype module satisfies the requirements, providing efficienttracking information, after being irradiated with a total fluencecomparable to the one expected through the lifetime of theexperiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of planar silicon pixel sensors with the RD53A readout chip for the Phase-2 Upgrade of the CMS Inner Tracker

The Large Hadron Collider at CERN will undergo an upgrade inorder to increase its luminosity to7.5 × 10$^{34}$ cm$^{-2}$s$^{-1}$. The increased luminosityduring this High-Luminosity running phase, starting around 2029,means a higher rate of proton-proton interactions, hence a largerionizing dose and particle fluence for the detectors. The currenttracking system of the CMS experiment will be fully replaced inorder to cope with the new operating conditions. Prototype planarpixel sensors for the CMS Inner Tracker with square50 μm × 50 μm and rectangular100 μm × 25 μm pixels read out by theRD53A chip were characterized in the lab and at the DESY-II testbeamfacility in order to identify designs that meet the requirements ofCMS during the High-Luminosity running phase. A spatial resolutionof approximately 3.4 μm (2 μm) is obtained using themodules with 50 μm × 50 μm(100 μm × 25 μm) pixels at the optimalangle of incidence before irradiation. After irradiation to a 1 MeVneutron equivalent fluence ofΦ$_{eq}$ = 5.3 × 10$^{15}$ cm$^{-2}$, a resolution of9.4 μm is achieved at a bias voltage of 800 V using a modulewith 50 μm × 50 μm pixel size. All modulesretain a hit efficiency in excess of 99% after irradiation tofluences up to 2.1 × 10$^{16}$ cm$^{-2}$. Further studies ofthe electrical properties of the modules, especially crosstalk, arealso presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

How the discovery of Cold Noise delayed the production of ATLAS ITk strip tracker modules by a year

Here, the construction of the ATLAS strip tracker barrel will require the assembly of 12,000 barrel detector modules over the course of 3.5 years. In 2022, during the module pre-production phase, modules were found to display clusters of noisy channels outside required specifications when tested at operating temperatures (-35°C), called “Cold Noise”. Extensive investigations into the cause and mechanism of Cold Noise interrupted pre-production and occupied most barrel module assembly sites. This contribution presents an overview of the year-long investigations into Cold Noise, the final identification of the underlying mechanism and necessary changes for the transition to production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam-induced backgrounds measured in the ATLAS detector during local gas injection into the LHC beam vacuum

Inelastic beam-gas collisions at the Large Hadron Collider (LHC), within a few hundred metres of the ATLAS experiment, are known to give the dominant contribution to beam backgrounds. These are monitored by ATLAS with a dedicated Beam Conditions Monitor (BCM) and with the rate of fake jets in the calorimeters. These two methods are complementary since the BCM probes backgrounds just around the beam pipe while fake jets are observed at radii of up to several metres. In order to quantify the correlation between the residual gas density in the LHC beam vacuum and the experimental backgrounds recorded by ATLAS, several dedicated tests were performed during LHC Run 2. Local pressure bumps, with a gas density several orders of magnitude higher than during normal operation, were introduced at different locations. The changes of beam-related backgrounds, seen in ATLAS, are correlated with the local pressure variation. In addition the rates of beam-gas events are estimated from the pressure measurements and pressure bump profiles obtained from calculations. Using these rates, the efficiency of the ATLAS beam background monitors to detect beam-gas events is derived as a function of distance from the interaction point. These efficiencies and characteristic distributions of fake jets from the beam backgrounds are found to be in good agreement with results of beam-gas simulations performed with theFluka Monte Carlo programme.

43 PARTICLE ACCELERATORS↗

Quality concerns caused by quality control — deformation of silicon strip detector modules in thermal cycling tests

The ATLAS experiment at the Large Hadron Collider (LHC) is currently preparing to replace its present Inner Detector (ID) with the upgraded, all-silicon Inner Tracker (ITk) for its High-Luminosity upgrade (HL-LHC). The ITk will consist of a central pixel tracker and the outer strip tracker, consisting of about 19,000 strip detector modules. Each strip module is assembled from up to two sensors, and up to five flexes (depending on its geometry) in a series of gluing, wirebonding and quality control steps. During detector operation, modules will be cooled down to temperatures of about -35 °C (corresponding to the temperature of the support structures on which they will be mounted) after being initially assembled and stored at room temperature. In order to ensure compatibility with the detector's operating temperature range, modules are subjected to thermal cycling as part of their quality control process. Ten cycles between -35 °C and +40 °C are performed for each module, with full electrical characterisation tests at each high and low temperature point. As part of an investigation into the stress experienced by modules during cooling, it was observed that modules generally showed a change in module shape before and after thermal cycling. This paper presents a summary of the discovery and understanding of the observed changes, connecting them with excess module stress, as well as the resulting modifications to the module thermal cycling procedure.

47 OTHER INSTRUMENTATION↗

Search for a heavy neutral lepton with the MAGNETO-𝜈 experiment using 241 Pu 𝛽 − decays

The MAGNETO-𝜈 experiment searches for keV-scale heavy neutral leptons (HNLs) through precise measurements of the 𝛽 − -decay spectrum of 241 Pu. We present spectra comprising a total of 194 million 𝛽 − decays recorded using decay energy spectrometry with metallic magnetic calorimeters, representing the most statistically precise measurement of 241 Pu 𝛽 − decay to date. The 𝛽-endpoint energy was determined using 𝛾 rays and x-rays from an external 133 Ba calibration source, yielding 𝑄 𝛽 = 22.273⁢ (33) ⁢keV. The measured spectrum shows no statistically significant deviation from the allowed 𝛽-decay model. From a subset of the high-statistics data, we set an upper limit on the mixing of an 11.5-keV HNL with the electron neutrino, |𝑈 𝑒⁢4 | 2 < 1.31 × 10 −3 at the 95% confidence level.

A ≥ 220↗

Constraining the Synthesis of the Lightest 𝑝 Nucleus 74 Se

We provide the first experimental cross section of the 73 As(p, γ) 74 Se reaction to constrain one of the main destruction mechanisms of the p nucleus 74 Se in explosive stellar environments. The measurement was done using a radioactive 73 As beam at incident energies of 3.1 and 3.7 MeV/nucleon. Along with the total cross section measurement, statistical properties of the 74 Se compound nucleus were extracted, constraining the reaction cross section across the entire Gamow window of the γ process. The impact of the experimentally constrained reaction rate on 74 Se production in Type II supernovae is investigated through Monte Carlo one-zone network simulations. The results indicate that the overproduction of 74 Se by Type II supernova models cannot be resolved by nuclear physics and point towards the description of the astrophysical conditions of the γ process.

59 ≤ A ≤ 89↗

Single-nucleon knockout cross sections for reactions producing resonance states at or beyond the drip line

Single-nucleon knockout cross sections from fast secondary beams of the proton-drip-line nuclei 9 C, 13 O, and 17 Ne on a 9 Be target have been studied with emphasis on the production of resonance states. These states were identified by their invariant mass, and resonances with two-, three-, and five-body exit channels were examined. The measured cross sections for these states were compared with eikonal-model predictions using shell-model or variational Monte Carlo spectroscopic factors. The experimental yields were found to be suppressed relative to the model predictions, especially when a well-bound neutron or proton is removed. This suppression exceeds that found systematically in measured inclusive cross sections to particle-bound final states. In neutron knockout from 9 C and 13 O projectiles, this suppression of the unbound ground-state residuals yield is a factor of two to three times larger than that found in the bound final-state studies. Modifications to the structure of these systems due to coupling of the shell-model configurations to the continuum is expected to contribute to this extra suppression, especially when the final state is a near-threshold resonance. Furthermore, other considerations including the role of nuclear dynamics may be required to explain all the observed trends.

6 ≤ A ≤ 19↗

Simultaneous measurement of organic scintillator response to carbon and proton recoils

Organic scintillators are widely used for neutron detection in both basic nuclear physics and applications. While the proton light yield of organic scintillators has been extensively studied, measurements of the light yield from neutron interactions with carbon nuclei are scarce. Demonstrate a new approach for the simultaneous measurement of the proton and carbon light yield of organic scintillators. Provide new carbon light yield data for the EJ-309 liquid and EJ-204 plastic organic scintillators. A 33-MeV 2 H + beam from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory was impinged upon a 3-mm-thick Be target to produce a high-flux, broad-spectrum neutron beam. The double time-of-flight technique was extended to simultaneously measure the proton and carbon light yields of the organic scintillators, wherein the light output associated with the recoil particle was determined using np and nC elastic scattering kinematics. The proton and carbon light yield relations of the EJ-309 liquid and EJ-204 plastic organic scintillators were measured over a recoil energy range of approximately 0.3 to 1 MeV and 2 to 5 MeV, respectively, for EJ-309, and 0.2 to 0.5 MeV and 1 to 4 MeV, respectively, for EJ-204. Furthermore, these data provide new insight into the ionization quenching effect in organic scintillators and key input for simulation of the response of organic scintillators for both basic science and a broad range of applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗