Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Instrumentation for Hanford Direct-Feed Low-Activity Waste Real-Time, In-Line Process Monitoring - 18339

The direct-feed low-activity waste (DFLAW) process will utilize facilities in the Hanford tank farms to stage tank waste feed, a new facility to pretreat the tank waste feed, and facilities in the Hanford Waste Treatment and Immobilization Plant (WTP) to immobilize the low-activity waste (LAW) and disposition effluents from the vitrification process. Process sampling is used extensively throughout the DFLAW process to qualify waste feeds, control the process, and demonstrate compliance with regulatory and contractual commitments. The U.S. Department of Energy's Office of River Protection (ORP) has started a program to evaluate the potential benefits of replacing some sample collection requirements with realtime, in-line monitoring (RTIM). The program will identify, develop, and evaluate technologies that can reduce the number of samples required for WTP operation. Potential benefits of RTIM include elimination of process holds for sample analysis, a reduction in worker exposure to radiation and chemical hazards, decreased secondary waste volume, reducing the cost for sample collection and analysis, an improvement in product quality, and timely indication of process anomalies. In order to incorporate RTIM, the process control strategy for the overall process, as well as each unit operation, was reviewed and revisions to the strategies proposed. The following items were identified for incorporation of RTIM: - Real-time material balance calculations linked to the process control system; - Use of RTIM instruments to validate the material balance for selected analytes; - Anion analysis for determination of selected semi-volatile species (e.g., chlorine, sulfur, and fluorine) in the recycle stream. Based on the proposed process control strategy, a preliminary list of potential analytical equipment was developed. This was followed by a preliminary survey of instrument technologies currently on the market building on surveys performed for ORP, literature reviews, vendor web sites, and subject matter experts from the Savannah River National Laboratory and other U.S. Department of Energy national laboratories. Each technology was evaluated for measurement capability, operations and maintenance requirements, space requirements, and potential for application as process control instrumentation. The instrument technologies were chosen based on the following criteria: - Ability to perform analyses needed; - Potential to be used or adapted for use as process control instruments; - Potential to be adapted to size and operational constraints of standard WTP sample cabinets; - Operational and maintenance requirements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monitoring Linear Accelerator Output Constancy Using the PTW Linacheck

The PTW-Linacheck was assessed for its ability to monitor linear accelerator radiation output constancy. The key issues that were considered were the setup for daily output measurements, e.g., requirements for build-up and backscatter material, and the reproducibility and linearity of the device with linear accelerator output. An appropriate measurement setup includes a 10 x 10 cm field at 100 cm FSD, 5 cm backscatter, and no added build-up for 4 MeV electron beams, 1 cm added build-up for 6-16 MeV electron beams and 5 cm added build-up for 6-15 MV photon beams. Using this measurement setup, the dose linearity and short-term reproducibility were acceptable; however, the Linacheck should be recalibrated on a monthly basis to ensure acceptable long-term reproducibility.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-794: Validation of the MCNPX Monte Carlo Model of the Ocular Beam Line at the Proton Therapy Center Houston

Purpose: The PTCH is preparing the ocular proton beam nozzle for clinical use. Currently commissioning measurements are being performed using films, diodes and ionization chambers. In parallel, a Monte Carlo model of the beam line was created for integration into the automated Monte Carlo treatment plan computation system, MC{sup 2}. This work aims to compare Monte Carlo predictions to measured proton doses in order to validate the Monte Carlo model. Methods: A complete model of the double scattering ocular beam line has been created and is capable of simulating proton beams with a comprehensive set of beam modifying devices, including eleven different range modulator wheels. Simulations of doses in water were scored and compare to ion chamber measurements of depth doses, lateral dose profiles extracted from half beam block exposures of films, and diode measurements of lateral penumbrae at various depths. Results: All comparison resulted in an average relative entrance dose difference of less than 3% and peak dose difference of less than 2%. All range differences were smaller than 0.2 mm. The differences in the lateral beam profiles were smaller than 0.2 mm, and the differences in the penumbrae were all smaller than 0.4%. Conclusion: All available data shows excellent agreement of simulations and measurements. More measurements will have to be performed in order to completely and systematically validate the model. Besides simulating and measuring PDDs and lateral profiles of all remaining range modulator wheels, the absolute dosimetry factors in terms of number of source protons per monitor unit have to be determined.

60 APPLIED LIFE SCIENCES↗

MO-FG-202-08: Real-Time Monte Carlo-Based Treatment Dose Reconstruction and Monitoring for Radiotherapy

Purpose: This proof-of-concept study is to develop a real-time Monte Carlo (MC) based treatment-dose reconstruction and monitoring system for radiotherapy, especially for the treatments with complicated delivery, to catch treatment delivery errors at the earliest possible opportunity and interrupt the treatment only when an unacceptable dosimetric deviation from our expectation occurs. Methods: First an offline scheme is launched to pre-calculate the expected dose from the treatment plan, used as ground truth for real-time monitoring later. Then an online scheme with three concurrent threads is launched while treatment delivering, to reconstruct and monitor the patient dose in a temporally resolved fashion in real-time. Thread T1 acquires machine status every 20 ms to calculate and accumulate fluence map (FM). Once our accumulation threshold is reached, T1 transfers the FM to T2 for dose reconstruction ad starts to accumulate a new FM. A GPU-based MC dose calculation is performed on T2 when MC dose engine is ready and a new FM is available. The reconstructed instantaneous dose is directed to T3 for dose accumulation and real-time visualization. Multiple dose metrics (e.g. maximum and mean dose for targets and organs) are calculated from the current accumulated dose and compared with the pre-calculated expected values. Once the discrepancies go beyond our tolerance, an error message will be send to interrupt the treatment delivery. Results: A VMAT Head-and-neck patient case was used to test the performance of our system. Real-time machine status acquisition was simulated here. The differences between the actual dose metrics and the expected ones were 0.06%–0.36%, indicating an accurate delivery. ∼10Hz frequency of dose reconstruction and monitoring was achieved, with 287.94s online computation time compared to 287.84s treatment delivery time. Conclusion: Our study has demonstrated the feasibility of computing a dose distribution in a temporally resolved fashion in real-time and quantitatively and dosimetrically monitoring the treatment delivery.

60 APPLIED LIFE SCIENCES↗

Refining Groundwater Monitoring Approaches Through an Objectives-Driven Process - 16333

Groundwater monitoring is conducted throughout the groundwater remediation process, from initial site characterization through demonstration of cleanup objectives attainment. The DOE uses the groundwater monitoring data to define plumes, manage ongoing remediation, and determine how close the contamination levels are to meeting an endpoint criteria, such as a drinking water standard. Due to the expense of groundwater sampling and analysis, the DOE Office of Environmental Management compiled a synopsis of monitoring technologies and approaches, and defined opportunities for improving environmental remediation monitoring. This information included techniques to optimize and streamline groundwater monitoring. At the Hanford Site, years of extensive groundwater monitoring have been applied to support characterization and remedy-selection activities. Continuation of this monitoring intensity would be costly and would need to be reviewed in the context of future activities for groundwater remedy implementation. A structured review of monitoring plans is underway and has identified significant potential changes to the monitoring approach. These changes have been developed based on careful definition of monitoring objectives and consideration of innovative and targeted techniques to gather the appropriate data for remedy performance monitoring and transition to longer-term monitoring and closure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PRODUCTION PROCESS MONITORING OF MULTILAYERED MATERIALS USING TIME-DOMAIN TERAHERTZ GAUGES

The results of both a laboratory and factory trial of a time-domain terahertz (TD-THz) multi-layer gauge for on-line process monitoring are presented. The TD-THz gauge is demonstrated on a two layer laminated plastic insulation material. The TD-THz gauge simultaneously measured the total and the individual layer thicknesses. Measurements were made while transversely scanning across a 12 foot wide sheet extruded at high speed in a factory environment. The results were analyzed for precision, accuracy, and repeatability; and demonstrated that the TD-THz gauge performed in an equivalent or superior manner to existing ionizing radiation gauges (which measure only one layer). Many dielectric materials (e.g., plastic, rubber, paper, paint) are transparent to THz pulses, and the measurement of a wide range of samples is possible.

36 MATERIALS SCIENCE↗

A 400 kilowatt argon arc lamp for solar simulation

A 400 kilowatt argon arc lamp for a solar simulator has been designed, operated, and evaluated. The lamp is designed to produce one solar constant on a test area 4.6 by 9.2 meters when used with a collimator. The divergence angle of the beam is about 1 deg. The lamp is designed to operate completely within a vacuum environment. Over 80 kilowatt of directed radiation was monitored and measured for a 25-hour period during a recent test. In another test, an arc was operated at 400 kilowatt for 110 hours without removal or refurbishing of the electrodes. These tests have proven the cleanliness and integrity of the radiation source.

Decker, A. J.↗

A new era of nuclear test verification

The global network of sensors commissioned to monitor compliance with the Comprehensive Nuclear-Test-Ban Treaty has proven capable of that task and more.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Radiation Detection and Dual-Energy X-Ray Imaging for Port Security

Millions of cargo containers are transported across the United States border annually and are inspected for illicit radioactive material and contraband using a combination of passive radiation portal monitors (RPM) and high energy X-ray non-intrusive inspection (NII) systems. As detection performance is expected to vary with the material composition of cargo, characterizing the types of material present in cargo is important to national security. This work analyzes the passive radiation and dual energy radiography signatures from on RPM and two NII system, respectively. First, the cargos were analyzed to determine their ability to attenuate emissions from an embedded radioactive source. Secondly, dual-energy X-ray discrimination was used to determine the material composition and density of the cargos.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous measurement of multiple radiation-induced protein expression profiles using the Luminex(TM) system

Space flight results in the exposure of astronauts to a mixed field of radiation composed of energetic particles of varying energies, and biological indicators of space radiation exposure provides a better understanding of the associated long-term health risks. Current methods of biodosimetry have employed the use of cytogenetic analysis for biodosimetry, and more recently the advent of technological progression has led to advanced research in the use of genomic and proteomic expression profiling to simultaneously assess biomarkers of radiation exposure. We describe here the technical advantages of the Luminex(TM) 100 system relative to traditional methods and its potential as a tool to simultaneously profile multiple proteins induced by ionizing radiation. The development of such a bioassay would provide more relevant post-translational dynamics of stress response and will impart important implications in the advancement of space and other radiation contact monitoring. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

NASA Center JSC↗

SU-E-T-365: Estimation of Neutron Ambient Dose Equivalents for Radioprotection Exposed Workers in Radiotherapy Facilities Based On Characterization Patient Risk Estimation

Purpose: Previous measurements with Bonner spheres{sup 1} showed that normalized neutron spectra are equal for the majority of the existing linacs{sup 2}. This information, in addition to thermal neutron fluences obtained in the characterization procedure{sup 3}3, would allow to estimate neutron doses accidentally received by exposed workers, without the need of an extra experimental measurement. Methods: Monte Carlo (MC) simulations demonstrated that the thermal neutron fluence distribution inside the bunker is quite uniform, as a consequence of multiple scatter in the walls{sup 4}. Although inverse square law is approximately valid for the fast component, a more precise calculation could be obtained with a generic fast fluence distribution map around the linac, from MC simulations{sup 4}. Thus, measurements of thermal neutron fluences performed during the characterization procedure{sup 3}, together with a generic unitary spectra{sup 2}, would allow to estimate the total neutron fluences and H*(10) at any point{sup 5}. As an example, we compared estimations with Bonner sphere measurements{sup 1}, for two points in five facilities: 3 Siemens (15–23 MV), Elekta (15 MV) and Varian (15 MV). Results: Thermal neutron fluences obtained from characterization, are within (0.2–1.6×10{sup 6}) cm−{sup 2}•Gy{sup −1} for the five studied facilities. This implies ambient equivalent doses ranging from (0.27–2.01) mSv/Gy 50 cm far from the isocenter and (0.03–0.26) mSv/Gy at detector location with an average deviation of ±12.1% respect to Bonner measurements. Conclusion: The good results obtained demonstrate that neutron fluence and H*(10) can be estimated based on: (a) characterization procedure established for patient risk estimation in each facility, (b) generic unitary neutron spectrum and (c) generic MC map distribution of the fast component. [1] Radiat. Meas (2010) 45: 1391 – 1397; [2] Phys. Med. Biol (2012) 5 7:6167–6191; [3] Med. Phys (2015) 42:276 - 281. [4] IFMBE (2012) 39: 1245–1248. [5] ICRU Report 57 (1998)

60 APPLIED LIFE SCIENCES↗

PKS 2155-304 in July 2006: H.E.S.S. results and simultaneous multi-wavelength observations

The high-frequency-peaked BL Lac PKS 2155-304 is one of the brightest and best-studied VHE {gamma}-ray sources in the southern hemisphere. The High Energy Stereoscopic System (H.E.S.S.) has monitored PKS 2155-304 in 2006 and a multi-wavelength campaign involving X-ray, optical and radio observatories was triggered by the detection of an active state in July 2006, followed by the detection of two extraordinary flares on July, 28th and 30th, with peak fluxes {approx}100 times the usual values. We present results from the spectral and flux variability analysis of the VHE and simultaneous X-ray observations with Chandra during the second flare, as well as the detailed evolution of the VHE flux of PKS 2155-304 observed by H.E.S.S. in 2006. A study of flux correlations in the different frequency ranges during the second flare and the adjacent nights is discussed. We also present an interpretation of the active state of PKS 2155-304 in the framework of synchrotron self-Compton emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Monitoring Hexavalent Chromium in the Columbia River Hypo-rheic Zone - 16405

Concentrations of hexavalent chromium in groundwater at the 100-BC reactor area, located on the U.S. Department of Energy's Hanford Site, exceed the State of Washington's surface water quality criterion of 10 μg/L. Groundwater discharge to the Columbia River is the primary pathway for contaminants to reach potential receptors. Additional monitoring was needed in order to make an informed decision about groundwater remediation. An array of 23 hypo-rheic sampling points (HSPs) was installed and monitored. The HSPs consist of stainless-steel tubing with 15-cm long mesh screens at depths ranging from 0.15 to 1 meter in the riverbed. The HSPs, which are fully submerged at all river stages, were installed and sampled from a boat using low-flow pumping. The HSPs provided permanent sampling points to obtain samples of hypo-rheic zone water. They were equally suitable for high-frequency sampling, with up to 48 samples collected from each HSP over a 4-day period, and long-term monitoring, with monthly grab samples collected over a 2-year period. The HSPs could be sampled at any river stage, which varied up to 3 meters daily and 4 meters seasonally. Pumping rates were kept low to ensure representative sampling and avoid hydraulic short-circuiting. Short-term increases in river stage did not suppress hexavalent chromium concentrations. Monthly sampling showed that hexavalent chromium concentrations and specific conductance did decline during periods of sustained, seasonally high river stage. Concentrations varied from <2 μg/L during high river stage to 25 μg/L during moderate to low river stage, compared to 50 to 60 μg/L in near-river monitoring wells. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of a simple asynchronous mechanical light chopper to multielectron coincidence spectroscopy

A simple asynchronous mechanical light chopper, based on modification of a turbo-molecular pump, has been developed to extend the interval between light pulses in single bunch operation at the Photon Factory storage ring. A pulse repetition rate of 80 kHz was achieved using a cylinder rotating at 48000 rpm, with 100 slits of 80 {mu}m width. This allows absolute timing of particles up to 12.48 {mu}s instead of the single-bunch period of 624 ns. We have applied the chopper together with a light pulse monitor to measure multielectron coincidence spectra using a magnetic bottle time-of-flight electron spectrometer. With such a system, the electron energies are determined without any ambiguity, the folding of coincidence spectra disappears and the effect of false coincidences is drastically reduced.

43 PARTICLE ACCELERATORS↗

A self-checking fiber optic dosimeter for monitoring common errors in brachytherapy applications

Scintillation dosimetry with optical fiber readout [fiber optic dosimetry (FOD)] requires accurate measurement of light intensity. It is therefore vulnerable to loss of calibration if any changes occur in the efficiency of the optical pathway between the scintillator and the light detector. The authors show in this article that common types of errors that arise during clinical use for brachytherapy applications can be quantified using a light emitting diode to stimulate the scintillator, the so-called LED-FOD method, in an integrated and easy-to-use control unit that incorporates a compact peripheral component interconnect extension for instrumentation. Common sources of error include bending and mechanical compression of the fiber optic components and changes in the temperature of the scintillator. The authors show that the method can detect all the common errors studied in this work and that different types of errors can result in different correlations between the LED stimulated signal and the brachytherapy source signal. For a single-type error the LED-FOD can be used easily for system diagnosis and validation with the possibility to correct the dosimeter reading if the correlation between the LED stimulated signal and the brachytherapy source signal can be defined. For more complex errors, resulting from two or more errors occurring simultaneously, the LED-FOD method can also allow the clinician to make a judgment on the reliability of the dosimeter reading. This self-checking method can enhance the clinical robustness of the FOD for achieving accurate dose control.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correction for turbidity and pH interference for in situ hexavalent chromium monitoring - 16297

Hexavalent chromium is of increasing concern worldwide because of its toxicity, mobility in aqueous media, and relative abundance in waste effluent from a variety of industrial processes. Some of that waste has reached groundwater aquifers. Because of these factors, the fate and transport of hexavalent chromium in aquifers is of great importance for evaluating risk to fresh water sources and to the biosphere, and for designing means for abatement or remediation. Conventional sampling and analysis of groundwater samples from wells is labor intensive and therefore budget limited. The result is inadequate temporal and spatial characterization of contaminant plumes with respect to rate of movement, concentrations, and contaminant flux. A submersible hexavalent chromium sensor designed for extended-term deployment and based on ultraviolet colorimetry has been developed and tested at the Hanford Site, Washington. Adaptation of the method for in situ measurements requires automatic correction for sample turbidity and pH for every measurement. Turbidity is compensated nephelometrically. A method for estimating sample pH based on absorbance measurements made using two different wavelengths is presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dosimetric Comparison of RapidArc with Fixed Gantry Intensity-Modulated Radiotherapy Treatment for Multiple Liver Metastases Radiotherapy

We wanted to compare the dosimetric difference and treatment efficiency of RapidArc and fixed gantry intensity-modulated radiotherapy treatment (IMRT) for multiple liver metastases. Computed tomography datasets of 10 patients were studied retrospectively. IMRT plans were generated using 5 fields and RapidArc using either 1 or 2 arcs. The dose distribution of planning target volume (PTV), organs at risk (OARs), and the normal tissue were compared. Monitor units and treatment time were scored to measure expected treatment efficiency. Both RapidArc and IMRT plans resulted in equivalent target coverage. There was no statistically significant difference for the maximum and the minimum dose of PTV. RapidArc plans achieved an improved conformity index compared with IMRT (RA1 = 1.68 {+-} 0.27, RA2 = 1.61 {+-} 0.25, IMRT = 1.80 {+-} 0.37). For OARs, all techniques respected planning objectives. RapidArc plans had a lower dose in V{sub 40} of small bowel than IMRT, but were higher in mean dose of kidneys. Concerning the V{sub 5}, V{sub 10}, and V{sub 15} of healthy tissue, RapidArc plans were higher than IMRT. However, the V{sub 20}, V{sub 25}, and V{sub 30} of healthy tissue in RapidArc plans were lower than IMRT. Monitor units per fraction of RapidArc plans were about 40% or 46% of IMRT. Compared with IMRT plans, treatment time of RapidArc plans were reduced by 60% or 70%. All techniques respected planning objectives. RapidArc showed statistical improvements in conformity index and healthy tissue sparing with uncompromised target coverage. This, in combination with fewer monitor units and short delivery time, can lead to clinically significant advances for the treatment of multiple liver metastases.

61 RADIATION PROTECTION AND DOSIMETRY↗