Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROTATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

SU-E-J-195: Quantification of Rotations and Deformations in Head and Heck Radiotherapy

Purpose: To quantify the magnitude of patient rotations and deformations over the course of head and neck radiotherapy. Methods: 45 CBCT images acquired weekly were selected retrospectively from 5 head and neck cancer patients. CBCT images were registered to the corresponding planning CT images using translation, rigid-body, and cubic B-spline deformable transformations. Elastix ( elastix.isi.uu.nl ), an open-source public domain registration algorithm, was used for all registrations with mutual information as similarity metric and gradient descent as optimization. Four-level multiresolution approach was employed with 2 cm B-spline grid spacing at the finest resolution. Registration qualities were visually verified. Rotational occurrences were quantified from the rigid-body registrations. The magnitude of deformations in planning target volumes (PTV) and organs were quantified from the deformation vector fields with rigid registrations as baseline. Results: The measured rotations (mean±std) were 1.0±1.0 deg, - 0.3±1.0 deg, and 0.1±0.8 deg in the sagittal, coronal, and axial plains respectively. The estimated magnitudes of deformations (mean±std) were 3.4±2.1 mm for PTVs, 2.9±1.2 mm for parotid glands, 2.8±1.2 mm for mandible, and 2.2±1.1 mm for spinal cord. The overall deformation in the body contour was 4.3±4.3 mm. The organ spatial deviation due to rotation was small and approximately 8.4% of that from deformations. Results varied among patients. Conclusion: Rotations occurred about 1.0 deg (1SD) in the H'N area. Daily geometric deviation of target volumes was considerable and mainly from tissue deformation than rotations. Proper safety margin is necessary for adequate target coverage. Online plan adaptation may mitigate the daily differences between the plan and actual patient poses. Partially supported by a grant from Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

SU-E-T-333: Dosimetric Impact of Rotational Error On the Target Coverage in IMPT Lung Cancer Plans

Purpose: The main purpose of this study was to investigate the impact of rotational (yaw, roll, and pitch) error on the planning target volume (PTV) coverage in lung cancer plans generated by intensity modulated proton therapy (IMPT). Methods: In this retrospective study, computed tomography (CT) dataset of previously treated lung case was used. IMPT plan were generated on the original CT dataset using left-lateral (LL) and posterior-anterior (PA) beams for a total dose of 74 Gy[RBE] with 2 Gy[RBE] per fraction. In order to investigate the dosimetric impact of rotational error, 12 new CT datasets were generated by re-sampling the original CT dataset for rotational (roll, yaw, and pitch) angles ranged from −5° to +5°, with an increment of 2.5°. A total of 12 new IMPT plans were generated based on the re-sampled CT datasets using beam parameters identical to the ones in the original IMPT plan. All treatment plans were generated in XiO treatment planning system. The PTV coverage (i.e., dose received by 95% of the PTV volume, D95) in new IMPT plans were then compared with the PTV coverage in the original IMPT plan. Results: Rotational errors caused the reduction in the PTV coverage in all 12 new IMPT plans when compared to the original IMPT lung plan. Specifically, the PTV coverage was reduced by 4.94% to 50.51% for yaw, by 4.04% to 23.74% for roll, and by 5.21% to 46.88% for pitch errors. Conclusion: Unacceptable dosimetric results were observed in new IMPT plans as the PTV coverage was reduced by up to 26.87% and 50.51% for rotational error of 2.5° and 5°, respectively. Further investigation is underway in evaluating the PTV coverage loss in the IMPT lung cancer plans for smaller rotational angle change.

60 APPLIED LIFE SCIENCES↗

Multihelix rotating shield brachytherapy for cervical cancer

Purpose: To present a novel brachytherapy technique, called multihelix rotating shield brachytherapy (H-RSBT), for the precise angular and linear positioning of a partial shield in a curved applicator. H-RSBT mechanically enables the dose delivery using only linear translational motion of the radiation source/shield combination. The previously proposed approach of serial rotating shield brachytherapy (S-RSBT), in which the partial shield is rotated to several angular positions at each source dwell position [W. Yang et al., “Rotating-shield brachytherapy for cervical cancer,” Phys. Med. Biol. 58, 3931–3941 (2013)], is mechanically challenging to implement in a curved applicator, and H-RSBT is proposed as a feasible solution. Methods: A Henschke-type applicator, designed for an electronic brachytherapy source (Xoft Axxent™) and a 0.5 mm thick tungsten partial shield with 180° or 45° azimuthal emission angles and 116° asymmetric zenith angle, is proposed. The interior wall of the applicator contains six evenly spaced helical keyways that rigidly define the emission direction of the partial radiation shield as a function of depth in the applicator. The shield contains three uniformly distributed protruding keys on its exterior wall and is attached to the source such that it rotates freely, thus longitudinal translational motion of the source is transferred to rotational motion of the shield. S-RSBT and H-RSBT treatment plans with 180° and 45° azimuthal emission angles were generated for five cervical cancer patients with a diverse range of high-risk target volume (HR-CTV) shapes and applicator positions. For each patient, the total number of emission angles was held nearly constant for S-RSBT and H-RSBT by using dwell positions separated by 5 and 1.7 mm, respectively, and emission directions separated by 22.5° and 60°, respectively. Treatment delivery time and tumor coverage (D{sub 90} of HR-CTV) were the two metrics used as the basis for evaluation and comparison. For all the generated treatment plans, the D{sub 90} of the HR-CTV in units of equivalent dose in 2 Gy fractions (EQD2) was escalated until the D{sub 2cc} (minimum dose to hottest 2 cm{sup 3}) tolerance of either the bladder (90 Gy{sub 3}), rectum (75 Gy{sub 3}), or sigmoid colon (75 Gy{sub 3}) was reached. Results: Treatment time changed for H-RSBT versus S-RSBT by −7.62% to 1.17% with an average change of −2.8%, thus H-RSBT treatments times tended to be shorter than for S-RSBT. The HR-CTV D{sub 90} also changed by −2.7% to 2.38% with an average of −0.65%. Conclusions: H-RSBT is a mechanically feasible delivery technique for use in the curved applicators needed for cervical cancer brachytherapy. S-RSBT and H-RSBT were clinically equivalent for all patients considered, with the H-RSBT technique tending to require less time for delivery.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-JeP3-01: A Statistical Model for Analyzing the Rotational Error of Single Iso-Center Technique

Purpose: To develop a generalized statistical model that incorporates the treatment uncertainty from the rotational error of single iso-center technique, and calculate the additional PTV (planning target volume) margin required to compensate for this error. Methods: The random vectors for setup and additional rotation errors in the three-dimensional (3D) patient coordinate system were assumed to follow the 3D independent normal distribution with zero mean, and standard deviations σx, σy, σz, for setup error and a uniform σR for rotational error. Both random vectors were summed, normalized and transformed to the spherical coordinates to derive the chi distribution with 3 degrees of freedom for the radical distance ρ. PTV margin was determined using the critical value of this distribution for 0.05 significant level so that 95% of the time the treatment target would be covered by ρ. The additional PTV margin required to compensate for the rotational error was calculated as a function of σx, σy, σz and σR. Results: The effect of the rotational error is more pronounced for treatments that requires high accuracy/precision like stereotactic radiosurgery (SRS) or stereotactic body radiotherapy (SBRT). With a uniform 2mm PTV margin (or σx =σy=σz=0.7mm), a σR=0.32mm will decrease the PTV coverage from 95% to 90% of the time, or an additional 0.2mm PTV margin is needed to prevent this loss of coverage. If we choose 0.2 mm as the threshold, any σR>0.3mm will lead to an additional PTV margin that cannot be ignored, and the maximal σR that can be ignored is 0.0064 rad (or 0.37°) for iso-to-target distance=5cm, or 0.0032 rad (or 0.18°) for iso-to-target distance=10cm. Conclusions: The rotational error cannot be ignored for high-accuracy/-precision treatments like SRS/SBRT, particularly when the distance between the iso-center and target is large.

60 APPLIED LIFE SCIENCES↗

WE-DE-201-08: Multi-Source Rotating Shield Brachytherapy Apparatus for Prostate Cancer

Purpose: To introduce a novel multi-source rotating shield brachytherapy (RSBT) apparatus for the precise simultaneous angular and linear positioning of all partially-shielded 153Gd radiation sources in interstitial needles for treating prostate cancer. The mechanism is designed to lower the detrimental dose to healthy tissues, the urethra in particular, relative to conventional high-dose-rate brachytherapy (HDR-BT) techniques. Methods: Following needle implantation, the delivery system is docked to the patient template. Each needle is coupled to a multi-source afterloader catheter by a connector passing through a shaft. The shafts are rotated by translating a moving template between two stationary templates. Shaft walls as well as moving template holes are threaded such that the resistive friction produced between the two parts exerts enough force on the shafts to bring about the rotation. Rotation of the shaft is then transmitted to the shielded source via several keys. Thus, shaft angular position is fully correlated with the position of the moving template. The catheter angles are simultaneously incremented throughout treatment as needed, and only a single 360° rotation of all catheters is needed for a full treatment. For each rotation angle, source depth in each needle is controlled by a multi-source afterloader, which is proposed as an array of belt-driven linear actuators, each of which drives a source wire. Results: Optimized treatment plans based on Monte Carlo dose calculations demonstrated RSBT with the proposed apparatus reduced urethral D{sub 1cc} below that of conventional HDR-BT by 35% for urethral dose gradient volume within 3 mm of the urethra surface. Treatment time to deliver 20 Gy with multi-source RSBT apparatus using nineteen 62.4 GBq {sup 153}Gd sources is 117 min. Conclusions: The proposed RSBT delivery apparatus in conjunction with multiple nitinol catheter-mounted platinum-shielded {sup 153}Gd sources enables a mechanically feasible urethra-sparing treatment technique for prostate cancer in a clinically reasonable timeframe.

60 APPLIED LIFE SCIENCES↗

Experimental study of magnetized plasma rotation in crossed fields

Rotation of magnetized plasma between two coaxial electrodes in crossed electric and magnetic fields was studied experimentally. Three regimes of plasma rotation were observed. In the first regime, the radial electric field is created by a beam−plasma discharge due to the charging of the inner axial electrode by electrons, the outer electrode being grounded. Plasma rotation in this case is accompanied by strong high-frequency current oscillations detected by a Mach probe. When a negative voltage was applied to the coaxial electrodes, the second regime was observed, in which weakly perturbed quasi-stationary plasma rotation occurred at a relatively low radial current. The third regime of plasma rotation was observed upon a spontaneous disruption of the second regime. It is characterized by high currents of ~1 kA, sheared plasma rotation, and excitation of high-frequency perturbations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Theoretical investigations on Kerr and Faraday rotations in topological multi-Weyl Semimetals

Motivated by the recent proposal of giant Kerr rotation in WSMs, we investigate the Kerr and Faraday rotations in time-reversal broken multi-Weyl semimetals (mWSMs) in the absence of an external magnetic field. Using the framework of Kubo response theory, we find that both the longitudinal and transverse components of the optical conductivity in mWSMs are modified by the topological charge ( n n ). Engendered by the optical Hall conductivity, we show in the thin film limit that, while the giant Kerr rotation and corresponding ellipticity are independent of n n , the Faraday rotation and its ellipticity angle scale as n n and n^2 n 2 , respectively. In contrast, the polarization rotation in semi-infinite mWSMs is dominated by the axion field showing n n dependence. In particular, the magnitude of Kerr (Faraday) angle decreases (increases) with increasing n n in Faraday geometry, whereas in Voigt geometry, it depicts different n n -dependencies in different frequency regimes. The obtained results on the behavior of polarization rotations in mWSMs could be used in experiments as a probe to distinguish single, double, and triple WSMs, as well as discriminate the surfaces of mWSMs with and without hosting Fermi arcs.

36 MATERIALS SCIENCE↗

Study of Particle Rotation Effect in Gas-Solid Flows using Direct Numerical Simulation with a Lattice Boltzmann Method

A new and efficient direct numerical method with second-order convergence accuracy was developed for fully resolved simulations of incompressible viscous flows laden with rigid particles. The method combines the state-of-the-art immersed boundary method (IBM), the multi-direct forcing method, and the lattice Boltzmann method (LBM). First, the multi-direct forcing method is adopted in the improved IBM to better approximate the no-slip/no-penetration (ns/np) condition on the surface of particles. Second, a slight retraction of the Lagrangian grid from the surface towards the interior of particles with a fraction of the Eulerian grid spacing helps increase the convergence accuracy of the method. An over-relaxation technique in the procedure of multi-direct forcing method and the classical fourth order Runge-Kutta scheme in the coupled fluid-particle interaction were applied. The use of the classical fourth order Runge-Kutta scheme helps the overall IB-LBM achieve the second order accuracy and provides more accurate predictions of the translational and rotational motion of particles. The preexistent code with the first-order convergence rate is updated so that the updated new code can resolve the translational and rotational motion of particles with the second-order convergence rate. The updated code has been validated with several benchmark applications. The efficiency of IBM and thus the efficiency of IB-LBM were improved by reducing the number of the Lagragian markers on particles by using a new formula for the number of Lagrangian markers on particle surfaces. The immersed boundary-lattice Boltzmann method (IBLBM) has been shown to predict correctly the angular velocity of a particle. Prior to examining drag force exerted on a cluster of particles, the updated IB-LBM code along with the new formula for the number of Lagrangian markers has been further validated by solving several theoretical problems. Moreover, the unsteadiness of the drag force is examined when a fluid is accelerated from rest by a constant average pressure gradient toward a steady Stokes flow. The simulation results agree well with the theories for the short- and long-time behavior of the drag force. Flows through non-rotational and rotational spheres in simple cubic arrays and random arrays are simulated over the entire range of packing fractions, and both low and moderate particle Reynolds numbers to compare the simulated results with the literature results and develop a new drag force formula, a new lift force formula, and a new torque formula. Random arrays of solid particles in fluids are generated with Monte Carlo procedure and Zinchenko's method to avoid crystallization of solid particles over high solid volume fractions. A new drag force formula was developed with extensive simulated results to be closely applicable to real processes over the entire range of packing fractions and both low and moderate particle Reynolds numbers. The simulation results indicate that the drag force is barely affected by rotational Reynolds numbers. Drag force is basically unchanged as the angle of the rotating axis varies.

36 MATERIALS SCIENCE↗

INFALLING–ROTATING MOTION AND ASSOCIATED CHEMICAL CHANGE IN THE ENVELOPE OF IRAS 16293–2422 SOURCE A STUDIED WITH ALMA

We have analyzed rotational spectral line emission of OCS, CH{sub 3}OH, HCOOCH{sub 3}, and H{sub 2}CS observed toward the low-mass Class 0 protostellar source IRAS 16293–2422 Source A at a sub-arcsecond resolution (∼0.″6 × 0.″5) with ALMA. Significant chemical differentiation is found on a scale of 50 au. The OCS line is found to trace well the infalling–rotating envelope in this source. On the other hand, the distributions of CH{sub 3}OH and HCOOCH{sub 3} are found to be concentrated around the inner part of the infalling–rotating envelope. With a simple ballistic model of the infalling–rotating envelope, the radius of the centrifugal barrier (a half of the centrifugal radius) and the protostellar mass are evaluated from the OCS data to be from 40 to 60 au and from 0.5 to 1.0 M {sub ⊙}, respectively, assuming the inclination angle of the envelope/disk structure to be 60° (90° for the edge-on configuration). Although the protostellar mass is correlated with the inclination angle, the radius of the centrifugal barrier is not. This is the first indication of the centrifugal barrier of the infalling–rotating envelope in a hot corino source. CH{sub 3}OH and HCOOCH{sub 3} may be liberated from ice mantles by weak accretion shocks around the centrifugal barrier and/or by protostellar heating. The H{sub 2}CS emission seems to come from the disk component inside the centrifugal barrier in addition to the envelope component. The centrifugal barrier plays a central role not only in the formation of a rotationally supported disk but also in the chemical evolution from the envelope to the protoplanetary disk.

79 ASTRONOMY AND ASTROPHYSICS↗

A Rotation Rate for the Planetary-mass Companion DH Tau b

DH Tau b is a young planetary-mass companion orbiting at a projected separation of 320 au from its ∼2 Myr old host star DH Tau. With an estimated mass of 8–22 M{sub Jup} this object straddles the deuterium-burning limit, and might have formed via core or pebble accretion, disk instability, or molecular cloud fragmentation. To shed light on the formation history of DH Tau b, we obtain the first measurement of rotational line broadening for this object using high-resolution (R ∼ 25,000) near-infrared spectroscopy from Keck/NIRSPEC. We measure a projected rotational velocity (v sin i) of 9.6 ± 0.7 km s{sup −1}, corresponding to a rotation rate that is between 9% and 15% of DH Tau b’s predicted breakup speed. This low rotation rate is in good agreement with scenarios in which magnetic coupling between the companion and its circumplanetary disk during the late stages of accretion reduces angular momentum and regulates spin. We compare the rotation rate of DH Tau b to published values for other planetary-mass objects with masses between 0.3 and 20 M{sub Jup} and find no evidence of a correlation between mass and rotation rate in this mass regime. Finally, we search for evidence of individual molecules in DH Tau b’s spectrum and find that it is dominated by CO and H{sub 2}O, with no evidence of the presence of CH{sub 4}. This agrees with expectations given DH Tau b’s relatively high effective temperature (∼2300 K).

79 ASTRONOMY AND ASTROPHYSICS↗

Galaxy Size and Rotation Curve Diversity in ΛCDM with Baryons

The observed rotation curves of dwarf galaxies exhibit significant diversity at fixed halo mass, challenging galaxy formation within the cold dark matter (CDM) model. Previous cosmological galaxy formation simulations with baryonic physics fail to reproduce the full diversity of rotation curves, suggesting that there is a flaw in baryonic feedback models, observational bias, or that an alternative to CDM must be invoked. In this work, we use the Marvelous Massive Dwarf zoom-in simulations, a suite of high-resolution dwarf simulations with M 200 ∼ 10 10 –10 11 M ⊙ and M * ∼ 10 7 –10 9 M ⊙ , designed to target the mass range where the galaxy rotation curve diversity is maximized, i.e., between and 100 km s −1 . We add to this a set of low-mass galaxies from the Marvel Dwarf Zoom Volumes to extend the galaxy mass range to lower values. Our fiducial star formation and feedback models produce simulated dwarfs with a broader range of rotation curve shapes, similar to observations. These simulations both create dark matter cores via baryonic feedback, reproducing the slower-rising rotation curves, while also allowing for compact galaxies and steeply rising rotation curves. Our simulated dwarfs also reproduce the observed size–M * relation, including scatter, producing both extended and compact dwarfs for the first time in simulated field dwarfs. However, the slowly rising and high baryon mass fraction, as well as the steeply rising and low baryon mass fraction, remain missing. We explore star formation and feedback models and conclude that previous simulations may have had feedback that was too strong to produce compact dwarfs.

Cruz, Akaxia [Flatiron Institute, New York, NY (Un↗

Solar rotation as determined from OSO-4 EUV spectroheliograms.

Spectroheliograms obtained in extreme ultraviolet (EUV) lines and the Lyman continuum are used to determine the rotation rate of the solar chromosphere, transition region, and corona. A cross-correlation analysis of the observations indicates the presence of differential rotation through the chromosphere and transition region. The rotation rate does not vary with height. The average sidereal rotation rate is given by omega (deg/day) = 13.46-2.99 sin squared B where B is the solar latitude. This rate agrees with spectroscopic determinations of the photospheric rotation rate, but is slower by about 1 deg/day than rates determined from the apparent motion of photospheric magnetic fields and from the brightest points of active regions observed in the EUV. The corona does not clearly show differential rotation as do the chromosphere and transition region.

Dupree, A. K.↗

Differential rotation of solar filaments

The latitudinal component of solar differential rotation and the possibility of a radial component are discussed and compared to the observed rotational velocities of solar filaments. The author's values of rotational rate versus heliographic latitude for 100 points in the solar atmosphere derived from 17 quiescent filaments are shown to be comparable to the rates found by d'Azambuja and d'Azambuja (1948). The filament rate is significantly greater than the spot rate (Newton and Nunn, 1951); the difference cannot be accounted for by the poleward migration of filaments and seems to reflect a true radial gradient of rotational velocity in the sun. It is shown that filaments in closer proximity to active regions usually exhibit no differential rotation, while those far from active regions generally show it clearly. Comparison with Mt. Wilson photospheric Doppler measurements shows that filaments rotate faster than the general photosphere and that the spot rate exceeds that for the general photosphere.

Glackin, D. L.↗

Differential rotation rates for short-lived regions of emerging magnetic flux

We have measured the synodic rotation rates of a sample of compact X-ray emission features lasting from 1 day to 7 days, thus bridging the transition between X-ray bright points and active regions. The rotation rate is found to be a function of the lifetime, or size, of the feature; shorter-lived smaller features rotate more slowly than long-lived ones. The rotation rate for features lasting 2 days or less is consistent with that of the photospheric gas. The longest-lived features rotate at a rate about 5% higher, consistent with the sunspot rotation rate.

Golub, L.↗

Free collapse of a rotating sphere of stars

The free-fall collapse of a system of 115,000 stars was studied by means of a three-dimensional simulation on the ILLIAC IV computer. The system started from a spherical shape with uniform density and rigid rotation which balanced the gravitational force in the equatorial plane. The system settled down into a 'hot' prolate 'bar' in about two initial rotation periods. This bar rotates about a short axis and is a long-lived form. Detailed discussion of the development of this system leads to several important dynamical inferences: (1) the first collapse does not become triaxial, and the prolate form follows much later; (2) forms seen in projection along the rotation axis are strikingly similar to forms seen in disk galaxy simulations, notwithstanding an unusual thickness along the rotation axis (this strengthens confidence in disk galaxy simulations); (3) many elliptical galaxies must be prolate objects rotating about a short axis and seen in projection; and (4) collapse models of galaxy formation lead to strongly anisotropic velocity dispersions, which are not in agreement with observation.

Miller, R. H.↗

Dynamics of rotating and oscillating free drops

The Dynamics of Rotating and Oscillating Free Drops (DROP) experiment is to be performed using the Drop Dynamics Module (DDM). The main scientific objectives of the DROP experiment are the study of the equilibrium figures of a rotating drop and the study of the large-amplitude oscillations of a liquid drop. The objective of the DROP experiment in relation to the DDM is to establish the advantages of conducting future drops and bubbles experiments in space. The DROP experiment will be subjected to continual to ensure that the experiments are scientifically current and available. The two component experiments (rotation and oscillation) of the DROP experiment have been chosen as the simplest experiments representative of the entire class of drop dynamics experiments. The component experiment on the equilibrium shapes of a rotating liquid drop of a simple liquid is not only an important and interesting experiment in its own right, but is also the simplest gyrostatic experiment that can be performed. In later experiments, more complicated liquids can be used; bubbles can be included; and the dynamics of rotating drops can be studied. This experiment, as it now stands, is an important exercise of the module's ability to provide drop rotation and the requisite science data.

Wang, T. G.↗

Rotational discontinuities and the structure of the magnetopause

Symmetric and asymmetric rotational discontinuities are studied by means of a one-dimensional computer simulation and by single-particle trajectory calculations. The numerical simulations show the symmetric rotation to be stable for both ion and electron senses of rotation with a thickness of the order of a few ion gyroradii when the rotation angle of the tangential field is 180 deg or less. Larger rotation angles tend to be unstable. In an expansive discontinuity, when the magnetic field on the downstream side of the discontinuity is larger, an expanding transition layer separating the highfield from a low-field region develops on the downstream side, and a symmetric rotational discontinuity forms at the upstream edge. The implication of these results for magnetopause structure and energy flow through the magnetopause is described.

Swift, D. W.↗

Asteroid rotation rates

A trend of increasing mean rotational frequency with increasing diameter is noted in asteroids with diameters greater than 120 km, irrespective of M-, S-, and C-type asteroid subset and family or nonfamily membership. This trend cannot be accounted for by observational selection. For asteroids with diameters smaller than 120 km mean rotational frequency increases with decreasing diameter, but within this group there is a subset with exceptionally long rotational periods. This marked change in the distribution at 120-km diameter could separate primordial asteroids from their collision products. It is also noted that, for asteroids of a given diameter, M asteroids rotate faster than S asteroids, which in turn rotate faster than C asteroids. For all types, family members rotate faster than nonfamily members.

Dermott, S. F.↗