Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RINGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Half-life determination of heavy ions in a storage ring considering feeding and depleting background processes

Heavy-ion storage rings have relatively large momentum acceptance which allows for multiple ion species to circulate at the same time. This needs to be considered in radioactive decay measurements of highly charged ions, where atomic charge exchange reactions can significantly alter the intensities of parent and daughter ions. In this study, we investigate this effect using the decay curves of ion numbers in the recent 205 Tl 81+ bound-state beta decay experiment conducted using the Experimental Storage Ring at GSI Darmstadt. To understand the intricate dynamics of ion numbers, we present a set of differential equations that account for various atomic and nuclear reaction processes—bound state beta decay, atomic electron recombination and capture, and electron ionization. By incorporating appropriate boundary conditions, we develop a set of differential equations that accurately simulate the decay curves of various simultaneously stored ions in the storage ring: 205 Tl 81+ , 205 Pb 81+ , 205 Pb 82+ , 200 Hg 79+ , and 200 Hg 80+ . Through a quantitative comparison between simulations and experimental data, we provide insights into the detailed reaction mechanisms governing stored heavy ions within the storage ring. Our approach effectively models charge-changing processes, reduces the complexity of the experimental setup, and provides a simpler method for measuring the decay half-lives of highly charged ions in storage rings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ring Pull Strain Analysis

Ring Pull Strain Analysis (RPSA) is a framework for analysis of Digital Image Correlation (DIC) data of gaugeless ring pull testing. It is meant for analysis of rings cut from tube cross sections and pulled in a displacement-controlled tensile test. This code takes load frame data, images take during testing, and csv files from the DIC analysis of those images and allows the user to analyze and plot data from the test. Some important features of the software include getting the strain values as a function of radial distance and angle, plotting of the strain around the ring, and stress-strain analysis of the load frame data. Additional capability is included with Ring Pull Coating Analysis (RPCA, also part of the software). Additional images are taken of samples with an outer coating and are used to correlate failure of the coating with strain values measured with DIC.

Beck, Peter↗

Photonic ring resonator filters for astronomical OH suppression

Ring resonators provide a means of filtering specific wavelengths from a waveguide, and optionally dropping the filtered wavelengths into a second waveguide. Both of these features are potentially useful for astronomical instruments. In this paper we focus on their use as notch filters to remove the signal from atmospheric OH emission lines from astronomical spectra. We derive the design requirements for ring resonators for OH suppression from theory and finite difference time domain simulations. We find that rings with small radii (< 10 μm) are required to provide an adequate free spectral range, leading to high index contrast materials such as Si and Si 3 N 4 . Critically coupled rings with high self-coupling coefficients should provide the necessary Q factors, suppression depth, and throughput for efficient OH suppression, but will require post-inscription tuning of the coupling and the resonant wavelengths. The overall prospects for the use of ring resonators in astronomical instruments is promising, provided efficient fibre-chip coupling can be achieved.

79 ASTRONOMY AND ASTROPHYSICS↗

Miniaturized integrated spectrometer using a silicon ring-grating design

We introduce and experimentally demonstrate a miniaturized integrated spectrometer operating over a broad bandwidth in the short-wavelength infrared (SWIR) spectrum that combines an add-drop ring resonator narrow band filter with a distributed Bragg reflector (DBR) based broadband filter realized in a silicon photonic platform. The contra-directional coupling DBR filter in this design consists of a pair of waveguide sidewall gratings that act as a broadband filter (i.e., 3.9 nm). The re-directed beam is then fed into the ring resonator which functions as a narrowband filter (i.e., 0.121 nm). In this scheme the free spectral range (FSR) limitation of the ring resonator is overcome by using the DBR as a filter to isolate a single ring resonance line. The overall design of the spectrometer is further simplified by simultaneously tuning both components through the thermo-optic effect. Moreover, several ring-grating spectrometer cells with different central wavelengths can be stacked in cascade in order to cover a broader spectrum bandwidth. This can be done by centering each unit cell on a different center wavelength such that the maximum range of one-unit cell corresponds to the minimum range of the next unit cell. This configuration enables high spectral resolution over a large spectral bandwidth and high extinction ratio (ER), making it suitable for a wide variety of applications.

42 ENGINEERING↗

Ectopic Expression of the RING Domain of the Arabidopsis PEROXIN2 Protein Partially Suppresses the Phenotype of the Photomorphogenic Mutant De-Etiolated1

The Arabidopsis CONSTITUTIVE PHOTOMORPHOGENIC/DE-ETIOLATED 1/FUSCA (COP/DET1/FUS) proteins repress photomorphogenesis by degrading positive regulators of photomorphogenesis, such as the transcription factor LONG HYPOCOTYL5 (HY5). The gain-of-function mutant ted3, which partially suppresses the det1 mutant, contains a missense mutation of a Val-to-Met substitution before the C-terminal RING finger domain of the peroxisomal membrane protein PEROXIN2 (PEX2). We hypothesized that a truncated PEX2 protein, which only contains the C-terminal RING domain, is initiated by the ted3 mutation and by-passes the function of DET1 in the nucleus. Although we have not been able to detect this hypothetic peptide in vivo, we show in this study that, when fused with a fluorescent protein and overexpressed, the PEX2 RING domain can localize to the nucleus, where it is able to interact with HY5, and PEX2 RING domain overexpression in det1 also partially suppresses the det1 phenotype. Compared with det1, ted3 det1 plants have significantly decreased levels of the HY5 protein and the expression of most of the analyzed HY5 target genes is altered to levels comparable to those in hy5. We conclude that compromised activity of HY5 may have been mainly responsible for the partial reversal of the det1 phenotype in ted3 det1. Our data support the notion that, when appropriately localized, some RING finger domains may be able to achieve neomorphic effects in the cell.

59 BASIC BIOLOGICAL SCIENCES↗

CSR behavior and aging model for the Viton© Fluorelastomer O-rings in the 9975 shipping package

The 9975 Type B shipping package is used within the DOE complex for shipping special nuclear materials. This package is re-certified annually in accordance with Safety Analysis Report for Packaging (SARP) requirements. The package is also used at the Savannah River Site as part of the long-term storage configuration of special nuclear materials. As such, the packages do not undergo annual recertification during storage, with uncertainty as to how long some of the package components will meet their functional requirements in the storage environment. The packages are currently approved for up to 15 years storage, and work continues to provide a technical basis to extend that period. This report describes efforts by the Savannah River National Laboratory (SRNL) to extend the service life estimate of Viton® GLT and GLT-S fluoroelastomer O-rings used in the 9975 shipping package. O-rings of both GLT and GLT-S compositions are undergoing accelerated aging at elevated temperature, and are periodically tested for compression stress relaxation (CSR) behavior. The CSR behavior of O-rings was evaluated at temperatures from 175 to 400 °F. These collective data were used to develop predictive models for extrapolation of CSR behavior to relevant service temperatures (< 156 °F). The predictive model developed from the CSR data conservatively indicates a service life of approximately 37 years for Viton GLT O-rings at the maximum effective service temperature of 156 °F. The estimated service life for Viton GLT-S O-rings is significantly longer.

36 MATERIALS SCIENCE↗

Crosslinking of SAVY-4000 O-rings as a Function of Aging Conditions

SAVY-4000 containers were developed as a part of DOE M 441.1-1 to protect workers who handle stored nuclear material from exposure due to loss of containment.1 The SAVY-4000 is comprised of three parts: a lid, a container, and a cross-linked fluoropolymer O-ring. Degradation of the O-ring during use could limit the lifetime of the SAVY-4000. In order to quantify the chemical changes of the Oring over time, the molecular weight between crosslinks was determined as a function of aging conditions using a swelling technique. Because the O-ring is a cross-linked polymer, it will absorb solvent into its matrix without dissolving. The relative amount of solvent uptake can be related to the degree of crosslinking using an equation developed by Paul Flory and John Rehner Jr3. This method was used to analyze O-ring samples aged under thermal and ionizing-radiation conditions. It was found that at the harsher thermal gaining conditions in absence of ionizing-radiation the average molecular weight between crosslinks decreased, indicating a rise in crosslinks, which may be attributable to advanced aging with no ionizing radiation present. Inversely, in the presence of ionizing radiation it was found that material has a higher level of cross-linking with age. This information could be used to help predict the lifetime of the O-rings in SAVY-4000 containers under service conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FY2018 Status Report: Model 9975 O-Ring Fixture Long-Term Leak Performance

A series of experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the Model 9975 shipping package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperature. Other methods such as compression stress-relaxation (CSR) tests and field surveillance are also on going to evaluate O-ring behavior. Seventy tests using PCV mock-ups with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, a smaller test matrix with fourteen additional tests was initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SAVY-4000 O-Ring and Filter Lifetime Extension Report

The 3-year accelerated aging study of the SAVY-4000 O-ring detailed in our previous Lifetime Extension Report showed very little evidence of significant degradation to samples subjected to aggressive elevated temperature and radiation conditions. Whole container thermal aging studies followed by helium leakage testing and compression set measurements were used to establish a failure criterion estimate for O-ring compression set of ≥ 65 %, which led to an O-ring lifetime estimate of greater than 65 years at 80°C. Herein, we describe a statistical model of the 3-year accelerated aging study and present additional results gathered in FY17 that further support the lifetime extension of the O-ring to 40 years at 80°C. Because we are choosing an extremely conservative lifetime value (40 years) compared to the aging study results (>65 years), the O-ring lifetime could be extended further, especially if supported by surveillance results collected over the years to come.

36 MATERIALS SCIENCE↗

Accident Scenarios for IOTA Ring and Dose Distributions Calculated with MARS15 Code

The Integrable Optics Test Accelerator (IOTA) at Fermilab’s Accelerator Science and Technology (FAST) facility [1] is a storage ring for advanced high intensity beam physics research. Layout of the ring is shown in Fig. 1. A plan view of the ring with enclosure walls are shown in Fig. 2. The entire beam, stored in the IOTA ring, is assumed to be completely lost at either of the three locations shown in Fig. 2. Therefore, we will consider three separate corresponding accident scenarios. The maximal amount of electrons stored in the IOTA ring is estimated to be 2×10 10 electrons with energy of 150 MeV. At locations 1 and 2 the beam is lost on 60-deg dipole walls, while at location 3 the beam is lost on Lambertson magnet wall.

43 PARTICLE ACCELERATORS↗

Ring-based electron cooler for EIC

An Electron Ion Collider (EIC) at Brookhaven National Laboratory (BNL) is being proposed as a new discovery machine for the nuclear physics and quantum chromodynamics. The hadron beam cooling plays an important role in the EIC machine to achieve its physics goals. The most challenging is cooling of protons at the highest energy in the EIC. In this paper, we present a possible design of a ring-based electron cooler for the high energy hadron beam cooling. In proposed approach, the electrons will cool the hadrons while being cooled themselves by radiation damping in the storage ring. For design of the cooler using storage ring approach several aspects becomes very important, including electron ring optics design, chromaticity correction, calculate the dynamic aperture, radiation damping, quantum excitation, and intrabeam scattering (IBS). In addition, such effects as beam-beam scattering (BBS) due to interaction of electrons with hadrons become of special concern. In this paper, we discuss and take into design all the effects above, as well as introduce generalized treatment of the BBS and 3-D quantum lifetime. A special feature of our design is an effective use of dispersion in the cooling section, both for the ions and electrons, to redistribute the cooling rate between the longitudinal and horizontal planes. Finally, the cooling performance is simulated for proton beam at the top energy of the EIC. Our conclusion is that such ring-based cooler could be a feasible approach to provide required parameters of hadron beam at the top energy of 275 GeV for the EIC.

43 PARTICLE ACCELERATORS↗

FY2023 Status Report: Model 9975 O-Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton ® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Damping Ring for the Rapid Cycling Synchrotron

The Electron-Ion Collider (EIC) electron accelerator chain consists of a 400 MeV electron Linear Accelerator (LINAC), the Rapid Cycling Synchrotron (RCS), and the Electron Storage Ring (ESR). The LINAC injects into the RCS, the RCS ramps to a top energy of 18 GeV and the electron beam is extracted to the ESR. To minimize the momentum spread of the 400 MeV injected beam and serve as a 28 nC electron accumulator ring, a damping ring is proposed. This ring may also serve as an intermediate energy booster for the RCS. The damping ring is not within the current baseline of the EIC project.

43 PARTICLE ACCELERATORS↗

Revisiting the Recommended Geometry for the Diametrally Compressed Ceramic C-Ring Specimen

A study conducted several years ago found that a stated allowable width/thickness (b/t) ratio in ASTM C1323 (Standard Test Method for Ultimate Strength of Advanced Ceramics with Diametrally Compressed C-Ring Specimens at Ambient Temperature) could ultimately cause the prediction of a non-conservative probability of survival when the measured C-ring strength was scaled to a different size. Because of that problem, this study sought to reevaluate the stress state and geometry of the C-ring specimen and suggest changes to ASTM C1323 that would resolve that issue. Elasticity, mechanics of materials, and finite element solutions were revisited with the C ring geometry. To avoid the introduction of more than 2% error, it was determined that the C ring width/thickness (b/t) ratio should range between 1-3 and that its inner radius/outer radius (ri/ro) ratio should range between 0.50-0.95. ASTM C1323 presently allows for b/t to be as large as 4 so that ratio should be reduced to 3.

36 MATERIALS SCIENCE↗

LIFETIME PREDICTION FOR MODEL 9975 O-RINGS IN KAMS

The Savannah River Site (SRS) is currently storing plutonium materials in the K-Area Materials Storage (KAMS) facility. The materials are packaged per the DOE 3013 Standard and transported and stored in KAMS in Model 9975 shipping packages, which include double containment vessels sealed with dual O-rings made of Parker Seals compound V0835-75 (based on Viton{reg_sign} GLT). The outer O-ring of each containment vessel is credited for leaktight containment per ANSI N14.5. O-ring service life depends on many factors, including the failure criterion, environmental conditions, overall design, fabrication quality and assembly practices. A preliminary life prediction model has been developed for the V0835-75 O-rings in KAMS. The conservative model is based primarily on long-term compression stress relaxation (CSR) experiments and Arrhenius accelerated-aging methodology. For model development purposes, seal lifetime is defined as a 90% loss of measurable sealing force. Thus far, CSR experiments have only reached this target level of degradation at temperatures {ge} 300 F. At lower temperatures, relaxation values are more tolerable. Using time-temperature superposition principles, the conservative model predicts a service life of approximately 20-25 years at a constant seal temperature of 175 F. This represents a maximum payload package at a constant ambient temperature of 104 F, the highest recorded in KAMS to date. This is considered a highly conservative value as such ambient temperatures are only reached on occasion and for short durations. The presence of fiberboard in the package minimizes the impact of such temperature swings, with many hours to several days required for seal temperatures to respond proportionately. At 85 F ambient, a more realistic but still conservative value, bounding seal temperatures are reduced to {approx}158 F, with an estimated seal lifetime of {approx}35-45 years. The actual service life for O-rings in a maximum wattage package likely lies higher than the estimates due to the conservative assumptions used for the model. For lower heat loads at similar ambient temperatures, seal lifetime is further increased. The preliminary model is based on several assumptions that require validation with additional experiments and longer exposures at more realistic conditions. The assumption of constant exposure at peak temperature is believed to be conservative. Cumulative damage at more realistic conditions will likely be less severe but is more difficult to assess based on available data. Arrhenius aging behavior is expected, but non-Arrhenius behavior is possible. Validation of Arrhenius behavior is ideally determined from longer tests at temperatures closer to actual service conditions. CSR experiments will therefore continue at lower temperatures to validate the model. Ultrasensitive oxygen consumption analysis has been shown to be useful in identifying non-Arrhenius behavior within reasonable test periods. Therefore, additional experiments are recommended and planned to validate the model.

42 ENGINEERING↗

NuSTORM $\mu$ Ring – Design and Injection Optimization

The design of the NuSTORM muon production beam line and storage ring is discussed. The facility includes a pion production target station with a pion collection horn and transport into a straight section of a storage ring. {\pi} decay within that straight section provides {\mu}'s that are stored within the ring for subsequent decay providing precision electron and muon neutrino beams. The ring and transport designs are described and optimized. Genetic Algorithm optimization of the horn and transport into the ring has been performed, providing a significant increase in intensity

43 PARTICLE ACCELERATORS↗

Polarization Studies for the eRHIC Electron Storage Ring

A hadron/lepton collider with polarized beams has been under consideration by the scientific community since some years, in the U.S. and Europe. Among the various proposals, those by JLAB and BNL with polarized electron and proton beams are currently under closer study in the U.S. In the BNL Ring-Ring design electrons are stored at top energy in a ring to be accommodated in the existing RHIC tunnel. The transversely polarized electron beam is injected into the storage ring at variable top energy, between 5 and 18 GeV. Polarization is brought into the longitudinal direction at the IP by a couple of spin rotators. In addition experimenters call for the simultaneous storage of electron bunches with both spin helicities. In this paper studies of the attainable beam polarization level and lifetime in the storage ring at 18 GeV are presented.

43 PARTICLE ACCELERATORS↗

FINDING THE CENTER: AN ANALYSIS OF THE TILTED RING MODEL FITS TO THE INNER AND OUTER PARTS OF SIX DWARF GALAXIES

We present a study of the H i emission of six dwarf galaxies. Profiles of dark matter halos of galaxies such as these have been the subject of much debate. In this paper we investigate the accuracy with which the dynamical center (the center of rotation) of each galaxy can be determined. We have used the tilted ring model. We find that the tilted ring method produces plausible centers that are consistent with other published works that used rings at radii larger than 1 kpc. At a radius of 1 kpc the method often converges on centers that do not make sense, producing, for example, radial velocities for the galaxies that are inconsistent with the data. The only way to get the method to work in the centers of galaxies is to use prior information about the redshifts to rule out implausible centers. This suggests that the tilted ring ring method may not be producing reliable rotational velocities in the central kiloparsecs of dwarf galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗