At least 703 records · Page 39

FLOWSHEET FOR ALUMINUM REMOVAL FROM SLUDGE BATCH 6

Samples of Tank 12 sludge slurry show a substantially larger fraction of aluminum than originally identified in sludge batch planning. The Liquid Waste Organization (LWO) plans to formulate Sludge Batch 6 (SB6) with about one half of the sludge slurry in Tank 12 and one half of the sludge slurry in Tank 4. LWO identified aluminum dissolution as a method to mitigate the effect of having about 50% more solids in High Level Waste (HLW) sludge than previously planned. Previous aluminum dissolution performed in a HLW tank in 1982 was performed at approximately 85 C for 5 days and dissolved nearly 80% of the aluminum in the sludge slurry. In 2008, LWO successfully dissolved 64% of the aluminum at approximately 60 C in 46 days with minimal tank modifications and using only slurry pumps as a heat source. This report establishes the technical basis and flowsheet for performing an aluminum removal process in Tank 51 for SB6 that incorporates the lessons learned from previous aluminum dissolution evolutions. For SB6, aluminum dissolution process temperature will be held at a minimum of 65 C for at least 24 days, but as long as practical or until as much as 80% of the aluminum is dissolved. As planned, an aluminum removal process can reduce the aluminum in SB6 from about 84,500 kg to as little as 17,900 kg with a corresponding reduction of total insoluble solids in the batch from 246,000 kg to 131,000 kg. The extent of the reduction may be limited by the time available to maintain Tank 51 at dissolution temperature. The range of dissolution in four weeks based on the known variability in dissolution kinetics can range from 44 to more than 80%. At 44% of the aluminum dissolved, the mass reduction is approximately 1/2 of the mass noted above, i.e., 33,300 kg of aluminum instead of 66,600 kg. Planning to reach 80% of the aluminum dissolved should allow a maximum of 81 days for dissolution and reduce the allowance if test data shows faster kinetics. 47,800 kg of the dissolved aluminum will be stored in Tank 8 and 21,000 kg will be stored in saltcake via evaporation. Up to 77% of the total aluminum planned for SB6 may be removed via aluminum dissolution. Storage of the aluminum-laden supernate in Tank 8 will require routine evaluation of the free hydroxide concentration in order to maintain aluminum in solution. Periodic evaluation will be established on concurrent frequency with corrosion program samples as previously established for aluminum-laden supernate from SB5 that is stored in Tank 11.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final CRADA Report: Evaluation of Trace Particle Removal Techniques for Enhanced Detection of Explosives in Air Cargo

This report describes the procedures used and the test results obtained at the Idaho National Laboratory (INL), to determine the ability of thermal and mechanical (vibration and airflow) methods to remove/harvest trace explosives from various material substrate surfaces relevant to air cargo. As part of the Battelle Memorial Institute’s (BMI) Air Cargo Screening (ACS) Initiative, INL conducted mechanical and thermal/mechanical removal tests using three different military explosives: C-4(RDX), cast TNT, and SEMTEX (PETN, 76% and RDX, 4.6%) on two substrate materials relevant to air cargo: metal and cardboard. This work leveraged similar experiments using homemade explosives (HME) which were funded by the Department of Homeland Security’s Science and Technology Directorate (DHS S&T). The DHS S&T tests involved evaluating the removal efficiencies of thermal and mechanical methods for four different HME: Ammonium Nitrate prills (AN, explosive grade), Guanidine Nitrate (GN, 98% pure in Methanol), Triacetone Triperoxide (TATP, 99.5% pure in Acetonitrile), and Hexamethylene Triperoxide Diamine (HMTD, 98.4% pure in Acetonitrile). Substrate materials used for the HME removal tests included metal, cotton, canvas, leather, shrink wrap, cardboard, and vinyl. This report documents the procedures that were used during the testing as well as the test results and recommendations for future Air Cargo Screening applications.

Source record↗

Chloride Salt Purification by Reaction With Thionyl Chloride Vapors to Remove Oxygen, Oxygenated Compounds, and Hydroxides

Molten chloride salts (including MgCl 2 , KCl, NaCl, and ZnCl 2 ) are being considered for heat transfer media for renewable (solar) and nuclear power generators, as fuel carrier for nuclear reactors, and as thermal energy storage media. Impurities such as oxygen, hydroxides, moisture, and sulfur are known to negatively influence the corrosion of materials in contact with the salt (e.g., structural metals). Commercially available chloride salts come with a range of impurities. Before using the chloride salts at high temperature, it is desirable to remove the impurities to increase the performance of the salt and reduce corrosion. In this study, we tested the use of thionyl chloride vaporized into a stream of argon to react with oxygenated impurities in a mixture of MgCl 2 -KCl-NaCl, removing them as HCl and SO 2 . The reagent was bubbled through the salt when both above and below the melting point. The reaction was followed using thermocouple data from the salt and by Fourier transform infrared (FTIR) spectroscopy on the exhaust of the reactor. The reaction kinetics were followed by comparing the peaks from SO 2 product to SOCl 2 reagent in the FTIR spectra. The purity of the salt was assessed at the end of the purification process by x-ray diffraction and inductively coupled plasma analysis. Although the process was effective in removing the oxygen content of the mixture, ternary compounds were formed in the process, including KNiCl 3 and KMgCl 3 . The nickel in KNiCl 3 came from the reaction between the salt and the nickel vessel. Thus, these experiments suggest that improvements to the process must be made before using SOCl 2 vapors for the purification of chloride salts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification and Removal of Contaminant Sequences From Ribosomal Gene Databases: Lessons From the Census of Deep Life

Earth’s subsurface environment is one of the largest, yet least studied, biomes on Earth, and many questions remain regarding what microorganisms are indigenous to the subsurface. Through the activity of the Census of Deep Life (CoDL) and the Deep Carbon Observatory, an open access 16S ribosomal RNA gene sequence database from diverse subsurface environments has been compiled. However, due to low quantities of biomass in the deep subsurface, the potential for incorporation of contaminants from reagents used during sample collection, processing, and/or sequencing is high. Thus, to understand the ecology of subsurface microorganisms (i.e., the distribution, richness, or survival), it is necessary to minimize, identify, and remove contaminant sequences that will skew the relative abundances of all taxa in the sample. In this meta-analysis, we identify putative contaminants associated with the CoDL dataset, recommend best practices for removing contaminants from samples, and propose a series of best practices for subsurface microbiology sampling. The most abundant putative contaminant genera observed, independent of evenness across samples, were Propionibacterium, Aquabacterium, Ralstonia, and Acinetobacter. While the top five most frequently observed genera were Pseudomonas, Propionibacterium, Acinetobacter, Ralstonia, and Sphingomonas. The majority of the most frequently observed genera (high evenness) were associated with reagent or potential human contamination. Additionally, in DNA extraction blanks, we observed potential archaeal contaminants, including methanogens, which have not been discussed in previous contamination studies. Such contaminants would directly affect the interpretation of subsurface molecular studies, as methanogenesis is an important subsurface biogeochemical process. Utilizing previously identified contaminant genera, we found that ~27% of the total dataset were identified as contaminant sequences that likely originate from DNA extraction and DNA cleanup methods. Thus, controls must be taken at every step of the collection and processing procedure when working with low biomass environments such as, but not limited to, portions of Earth’s deep subsurface. Taken together, we stress that the CoDL dataset is an incredible resource for the broader research community interested in subsurface life, and steps to remove contamination derived sequences must be taken prior to using this dataset.

16S rRNA↗

Nitrogen and Carbon Removal Capacity by Farmed Kelp Alaria marginata and Saccharina latissima Varies by Species

An increasing body of evidence shows that seaweeds, including kelp, can be used as a tool to neutralize or remove excess nutrients and metals from the water column. Here we report on a preliminary field assessment showing potential nutrient and carbon removal differences in sugar kelp and ribbon kelp grown in common gardens. Seawater and tissue samples were collected systematically from two farms in Alaska. Results show differences between the %N and %C content between Alaria marginata and Saccharina latissima. Results also show that tissue nitrogen in ribbon kelp varies sharply due to nitrogen availability in the water column. In contrast, the percentage of tissue N in sugar kelp remains comparatively stable. Our outcomes provide insight into potential differences in nutrient removal and harvest timing for different kelp species.

Umanzor, Schery (ORCID:0000000238124565)↗

Biochar Nanocomposite as an Inexpensive and Highly Efficient Carbonaceous Adsorbent for Hexavalent Chromium Removal

Biochar is commonly used for soil amendment, due to its excellent water-holding capacity. The Cr(VI) contamination of water is a current environmental issue in industrial regions. Here, we evaluated the effects of two-step modifications on boosting biochar’s performance in terms of the removal of aqueous hexavalent chromium (Cr(VI)), along with investigating the alterations to its surface properties. The first modification step was heat treatment under air at 300 °C, producing hydrophilic biochar (HBC). The resulting HBC was then impregnated with zero-valent iron nanoparticles (nZVI), creating an HBC/nZVI composite, adding a chemical reduction capability to the physical sorption mechanism. Unmodified biochar (BC), HBC, and HBC/nZVI were characterized for their physicochemical properties, including surface morphology and elemental composition, by SEM/EDS, while functional groups were ascertained by FTIR and surface charge by zeta potential. Cr(VI) removal kinetic studies revealed the four-time greater sorption capacity of HBC than BC. Although unmodified BC showed faster initial Cr(VI) uptake, it rapidly worsened and started desorption. After nZVI impregnation, the Cr(VI) removal rate of HBC increased by a factor of 10. FTIR analysis of biochars after Cr(VI) adsorption showed the presence of Cr(III) oxide only on the used HBC/nZVI and demonstrated that the carbonyl and carboxyl groups were the main groups involved in Cr(VI) sorption. Modified biochars could be considered an economical substitute for conventional methods.

36 MATERIALS SCIENCE↗

Removal of Iron from Pyrite-Rich Coal Refuse by Calcination and Magnetic Separation for Hydrometallurgical Extraction of Rare Earth Elements

In the metallurgical extraction of rare earth elements (REEs), the ratio of contaminant ions to REEs in the leachate dictates the cost and operational efficiency of the downstream processes. The current study investigated the potential iron contamination removal from the feed to the hydrometallurgical process by calcination followed by magnetic separation. The 2.20 specific gravity sink fraction of Baker coal seam coarse refuse was pulverized to finer than 180 μm, calcined at various temperatures, and separated into magnetic and non-magnetic fractions using a wet high-intensity magnetic separator at different field strengths. The untreated feed, calcined products, and their subsequent magnetic and non-magnetic fractions were subjected to acid leaching tests with 1.2 M sulfuric acid at 75 °C and 1% w/v solids concentration. The recovery of light and heavy rare earth elements (LREEs and HREEs, respectively) along with the concentration of common contaminant ions (Al, Ca, and Fe) were measured as output variables. The weight percent of magnetic material was maximized at approximately 29% by calcination at a temperature of 400 °C. Magnetic removal of this fraction using a field strength of 1.15 Tesla resulted in the rejection of 81% of the iron. Leaching of the magnetic fraction provided significantly higher Fe recovery relative to untreated feed material and the non-magnetic fraction. The non-magnetic fraction was subsequently calcined at 600 °C to dehydroxylate the clays and released the REE minerals in the same manner as the treatment of the original coarse refuse material. A comparison of the leachate elemental concentrations resulting from the leaching of both the calcined non-magnetic and original coarse refuse showed only a slight reduction in the iron content from the non-magnetic material. This finding combined with the REE loss in the magnetic fraction resulted in the conclusion that the magnetic removal step was unfavorable.

58 GEOSCIENCES↗

Removal of Non-Specifically Bound Proteins Using Rayleigh Waves Generated on ST-Quartz Substrates

Label-free biosensors are plagued by the issue of non-specific protein binding which negatively affects sensing parameters such as sensitivity, selectivity, and limit-of-detection. In the current work, we explore the possibility of using the Rayleigh waves in ST-Quartz devices to efficiently remove non-specifically bound proteins via acoustic streaming. A coupled-field finite element (FE) fluid structure interaction (FSI) model of a surface acoustic wave (SAW) device based on ST-Quartz substrate in contact with a liquid loading was first used to predict trends in forces related to SAW-induced acoustic streaming. Based on model predictions, it is found that the computed SAW body force is sufficient to overcome adhesive forces between particles and a surface while lift and drag forces prevent reattachment for a range of SAW frequencies. We further performed experiments to validate the model predictions and observe that the excitation of Rayleigh SAWs removed non-specifically bound (NSB) antigens and antibodies from sensing and non-sensing regions, while rinsing and blocking agents were ineffective. An amplified RF signal applied to the device input disrupted the specific interactions between antigens and their capture antibody as well. ST-quartz allows propagation of Rayleigh and leaky SH-SAW waves in orthogonal directions. Thus, the results reported here could allow integration of three important biosensor functions on a single chip, i.e., removal of non-specific binding, mixing, and sensing in the liquid phase.

59 BASIC BIOLOGICAL SCIENCES↗

Field Testing of an Affordable Zero-Liquid-Discharge Arsenic-Removal Technology for a Small-Community Drinking Water System in Rural California

Arsenic contamination in groundwater threatens public health, particularly in small, low-income communities lacking affordable treatment solutions. This study investigated the field implementation of novel air cathode assisted iron electrocoagulation (ACAIE) technology for arsenic removal in Allensworth, California, where groundwater arsenic concentrations exceeded 250 µg/L. Over four months, a pilot-scale ACAIE system, operating at 600 L/h, consistently reduced arsenic levels to below the EPA’s maximum contaminant level of 10 µg/L. Laboratory experiments informed the optimization of charge dosage and flow rates, which were validated during field testing of the ACAIE 600 L/h system. The in-situ generation of hydrogen peroxide at the cathode speeded up the reaction kinetics, ensuring high arsenic removal efficiency while allowing high throughput, even with a compact reactor size. An economic analysis demonstrated a treatment cost of USD 0.02/L excluding labor, highlighting the system’s affordability compared to conventional methods. Adding labor costs increased the treatment cost to USD 0.09/L. The regeneration of air cathodes extended their operational life, addressing a key maintenance challenge, thus reducing the costs slightly. Intermittent challenges were encountered with filtration and secondary contaminant removal; these issues highlight opportunities for further operational improvements. Despite these challenges, ACAIE’s low operational complexity, scalability, and cost-effectiveness make it a promising solution for underserved small communities. These findings provide critical insights into deploying sustainable arsenic remediation technologies that are tailored to the needs of rural, low-resource communities.

Bandaru, Siva R S↗

MARCUS ARM CN and CCN data reprocessed to remove ship exhaust influence

The data presented in this collection are the cloud condensation nuclei (CCN) and condensation nuclei (CN) from the MARCUS (Measurements of Aerosols, Radiation and CloUds over the Southern Oceans) campaign. This campaign involved the deployment of the ARM Mobile Facility aboard the RSV Aurora Australis between October 2017 and March 2018 during its summer season resupplying Australia’s Antarctic research stations from its port in Hobart, Australia. Routine processing undertaken by ARM does not remove platform exhaust associated with its deployment aboard ships. Consequently, the raw data were obtained and manually filtered to remove the influence of platform exhaust on the measurements by reviewing CCN, CN and BC data simultaneously and flagging all affected periods. Remaining data were then quality controlled for when instrument parameters were out of specification. CCN data are split into different streams for supersaturation settings before statistics for each hour being calculated. All data files contain NaN values for periods when data was removed for QC or exhaust reasons. Original raw data available at: Kulkarni, G. R., Flynn, C. and Koontz, A.: Atmospheric Radiation Measurement (ARM) user facility. 2017, updated hourly. Cloud Condensation Nuclei Particle Counter (AOSCCN100). 2017-10-29 to 2018-03-24, ARM Mobile Facility (MAR) Hobart, AUS to Antarctic Coast - resupply ship Aurora Australis; AMF2 (M1)., Atmospheric Radiation Measurement (ARM) user facility Data Center: Oak Ridge, Tennessee, USA [online] Available from: http://dx.doi.org/10.5439/1227964 (Accessed 9 November 2018), 2018. Kuang, C., Salwen, C., Boyer, M. and Singh, A.: Atmospheric Radiation Measurement (ARM) user facility. 2017, updated hourly. Condensation Particle Counter (AOSCPCF). 2017-10-29 to 2018-03-26, ARM Mobile Facility (MAR) Hobart, AUS to Antarctic Coast - resupply ship Aurora Australis; AMF2 (M1)., Atmospheric Radiation Measurement (ARM) user facility Data Center: Oak Ridge, Tennessee, USA [online] Available from: http://dx.doi.org/10.5439/1046184 (Accessed 9 November 2018), 2018.

54 ENVIRONMENTAL SCIENCES↗

Effects of casing boundary-layer removal on noise of a turbofan rotor

The effect of casing boundary-layer removal on noise produced by a turbofan rotor was measured. The outlet guide vanes were removed for these tests. A comparison was made between the noise measurements when the boundary layer was bled off and under zero bleed conditions. When the boundary layer was removed, overall sound pressure level was reduced 2 dB with moderate blade loading and 3 dB with heavier blade loading. An analysis of the changes in the spectral density with bleed is presented.

Goldstein, A. W.↗

A transient performance method for CO2 removal with regenerable adsorbents

A computer program is described which can be used to predict the transient performance of vacuum-desorbed sorbent beds for CO2 or water removal, and composite beds of two sorbents for simultaneous humidity control and CO2 removal. The program was written primarily for silica gel and molecular sieve inorganic sorbents, but can be used for a variety of adsorbent materials. Part 2 of this report describes a computer program which can be used to predict performance for multiple-bed CO2-removal sorbent systems. This program is an expanded version of the composite sorbent bed program described in Part 1.

Hwang, K. C.↗

Techniques for lithium removal from 1040 C aged tantalum alloy, T-111

The liquid ammonia and vacuum distillation techniques were found to be satisfactory for removing lithium from 1040 C aged T-111 (tantalum - 8-percent tungsten- 2-percent hafnium). Results of ductility tests and chemical analysis show that these two methods are adequate for removing lithium without embrittlement or contamination of the T-111. Moist air exposure of T-111 with traces of lithium on the surface produced mixed results. Some specimens were ductile; others were brittle. Brittle T-111 had an increased hydrogen content. Water removal of lithium from T-111 caused brittleness and an increased hydrogen concentration.

Gahn, R. F.↗

Water hyacinths for removal of cadmium and nickel from polluted waters

Removal of cadmium and nickel from static water systems utilizing water hyacinths (Eichhornia crassipes (Mart.) Solms) was investigated. This aquatic plant demonstrated the ability to rapidly remove heavy metals from aqueous systems by root absorption and concentration. Water hyacinths demonstrated the ability to absorb and concentrate up to 0.67 mg of cadmium and 0.50 mg of nickel per gram of dry plant material when exposed for a 24-hour period to waters polluted with from 0.578 to 2.00 ppm of these toxic metals. It is found that one hectare of water hyacinths has the potential of removing 300 g of cadmium or nickel from 240,000 liters of water polluted with these metals during a 24-hour period.

Wolverton, B. C.↗

Aquatic plants for removal of mevinphos from the aquatic environment

Fragrant waterlily (Nymphaea odorata, Ait.), joint-grass (Paspalum distichum L.), and rush (Juncus repens, Michx.) were used to evaluate the effectiveness of vascular aquatic plants in removing the insecticide mevinphos (dimethyl-1-carbomethoxy-1propen-2-yl phosphate) from waters contaminated with this chemical. The emersed aquatic plants fragrant waterlily and joint-grass removed 87 and 93 ppm of mevinphos from water test systems in less than 2 weeks without apparent damage to the plants; whereas rush, a submersed plant, removed less insecticide than the water-soil controls. Water-soil control still contained toxic levels of this insecticide, as demonstrated by fish bioassay studies, after 35 days.

Wolverton, B. C.↗

Water hyacinths and alligator weeds for removal of silver, cobalt, and strontium from polluted waters

Water hyacinths and alligator weeds demonstrated the ability to rapidly remove heavy metals from an aqueous system by root absorption and concentration. Water hyacinths demonstrated the ability to remove 0.439 mg of silver, 0.568 mg of cobalt, and 0.544 mg of strontium in an ionized form per gram of dry plant material in a 24-hour period. Alligator weeds removed a maximum of 0.439 mg of silver, 0.130 mg of cobalt, and 0.161 mg of strontium per gram of dry plant material per day.

Wolverton, B. C.↗

Spacelab baseline ECS trace contaminant removal test program

An estimate of the Spacelab Baseline Environmental Control System's contaminated removal capability was required to allow determination of the need for a supplemental trace contaminant removal system. Results from a test program to determine this removal capability are presented.

Ray, C. D.↗

Experiments on multiplane balancing using a laser for material removal

The modifications of a flexible rotor system for two-plane laser balancing is described. Experimental testing of the laser material removal method for balancing through the first bending critical speed was demonstrated. The test rig, optical configuration, and a neodymium glass laser system were assembled and calibrated for static and rotating material removal rates. The laser control computer program was combined with the influence coefficient balancing process, resulting in a completely automated data acquisition, laser, and balancing system. The laser system rotor was balanced through the first bending critical speed using the laser material removal procedure to apply trial weights and correction weights without stopping the rotor.

Demuth, R. S.↗