Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Diamond Beam Monitor for Medical Dosimetry (Final Report)

In this technical report we will discuss the efforts to develop diamond radiation detectors as dosimeters for therapeutic proton beam diagnostics, measuring the proton fluence as well as the beam profiles in high energy proton beams. The detector performance was recorded as the ion beam induced current (IBIC) from the 800MeV proton beam using different beam conditions. The lifetime of the detectors was also measured by monitoring the real-time detector response changes during the extensive proton irradiation. All irradiated diamond detectors were then characterized using synchrotron X-rays, by measuring the detector performance including I-V curves, response maps, flux scan and timing. The device performance decay was further studied with several simulation packages (SRIM\TRIM and FLUKA), and radiation damage mechanism was investigated by using experimental data and simulation models. Several impact factors (fluence rate, total dose, contact materials and cooling time) were discussed and the radiation effect on carrier transport was studied.

36 MATERIALS SCIENCE↗

Support of research in X-ray astronomy

Activities described include: (1) the evaluation of CCD detectors for X-ray astronomy applications; (2) contributions to the development of an imaging gas scintillation proportional counter; (3) the evaluation of certain metal oxide crystals as potential radiation detectors; (4) optical observations and searches for X-ray sources discovered by the HEAO-1 A2 experiment; and (5) theoretical modeling of nonequilibrium ionization structure of supernova remnants.

Garmire, G.↗

Hgi2 Sub 2 Crystal Growth for Nuclear Detectors

The objectives of this program are to obtain a benchmark quality sample grown at low-g conditions and to study vapor growth phenomena under space conditions. Ground-based crystals show a defect structure which impairs their performance as nuclear radiation detectors. These defects may be caused by the gravitational force acting on the crystal in its weakended state at the elevated growth temperature and by irregular convection patterns in the vapor during growth. Mechanical strength measurements have been performed (uniaxial compression tests) which show that the crystals exhibit slip parallel to the c-planes at stresses as low as 1/2 psi. Preliminary calculations using a simple linearized model indicate the oscillating instabilities in the convection part of the vapor transport system are unlikely, even at 1-g, provided that the utmost care is taken in the preparation of the crystal growth source material.

Schnepple, W. F.↗

Design and Challenges of Edge Computing ASICs on Front-End Electronics

In situ or hardware-embedded data processing of raw signals, close to their source, in radiation detectors is expected to provide dramatic improvements in data quality and volumes. However, the implementation of artificial neural networks (ANNs) in the front-end electronics, and the design of custom integrated circuits (ASICs), comes with challenges. In addition, detectors have to operate with limited power budget and implement complex functionalities in a very dense space. They often are exposed to extreme conditions as they work in high-radiation environments and/or cryogenic temperatures. This paper presents examples of applications and design methodologies for in-situ ANNs, along with the challenges of retaining the fidelity of the trained networks. For illustration, we use the problem of estimating the energy deposited by the radiation from digitized waveforms. The proposed implementation starts with an ML algorithm trained in Qkeras and eventually leads to an equivalent ASIC implementation. The associated design challenges in realizing energy and area efficient implementations in CMOS processes are reviewed. Novel approaches that employ hybrid technologies (combination of CMOS with memristors), in-memory computing models, and bio-inspired spiking neural networks are also highlighted

47 OTHER INSTRUMENTATION↗

Investigation of the Internal Electric Field in Cadmium Zinc Telluride Detectors Using the Pockels Effect and the Analysis of Charge Transients

The Pockels electro-optic effect can be used to investigate the internal electric field in cadmium zinc telluride (CZT) single crystals that are used to fabricate room temperature x and gamma radiation detectors. An agreement is found between the electric field mapping obtained from Pockels effect images and the measurements of charge transients generated by alpha particles. The Pockels effect images of a CZT detector along two mutually perpendicular directions are used to optimize the detector response in a dual anode configuration, a device in which the symmetry of the internal electric field with respect to the anode strips is of critical importance. The Pockels effect is also used to map the electric field in a CZT detector with dual anodes and an attempt is made to find a correlation with the simulated electric potential in such detectors. Finally, the stress-induced birefringence effects seen in the Pockels images are presented and discussed.

Groza, Michael↗

SU-E-T-167: Characterization of In-House Plastic Scintillator Detectors Array for Radiation Therapy

Purpose: To characterize basic performance of plastic scintillator detectors (PSD) array designed for dosimetry of radiation therapy. Methods: An in-house PSD array has been developed by placing single point PSD into customized 2D holder. Each point PSD is a plastic scintillating fiber-based detector designed for highly accurate measurement of small radiotherapy fields used in patient plan verification and machine commissioning and QA procedures. A parallel fiber without PSD is used for Cerenkov separation by subtracting from PSD readings. Cerenkov separation was confirmed by optical spectroscopy. Alternative Cerenkov separation approaches are also investigated. The optical signal was converted to electronic signal with a photodiode and then subsequently amplified. We measured its dosimetry performance, including percentage depth dose and output factor, and compared with reference ion chamber measurements. The PSD array is then placed along the radiation beam for multiple point dose measurement, representing subsets of PDD measurements, or perpendicular to the beam for profile measurements. Results: The dosimetry results of PSD point measurements agree well with reference ion chamber measurements. For percentage depth dose, the maximal differences between PSD and ion chamber results are 3.5% and 2.7% for 6MV and 15MV beams, respectively. For the output factors, PSD measurements are within 3% from ion chamber results. PDD and profile measurement with PSD array are also performed. Conclusions: The current design of multichannel PSD array is feasible for the dosimetry measurement in radiation therapy. Dose distribution along or perpendicular to the beam path could be measured. It might as well be used as range verification in proton therapy.A PS hollow fiber detector will be investigated to eliminate the Cerenkov radiation effect so that all 32 channels can be used.

60 APPLIED LIFE SCIENCES↗

Inclusion free cadmium zinc tellurium and cadmium tellurium crystals and associated growth method

The present disclosure provides systems and methods for crystal growth of cadmium zinc tellurium (CZT) and cadmium tellurium (CdTe) crystals with an inverted growth reactor chamber. The inverted growth reactor chamber enables growth of single, large, high purity CZT and CdTe crystals that can be used, for example, in X-ray and gamma detection, substrates for infrared detectors, or the like. The inverted growth reactor chamber enables reductions in the presence of Te inclusions, which are recognized as an important limiting factor in using CZT or CdTe as radiation detectors. The inverted growth reactor chamber can be utilized with existing crystal growth techniques such as the Bridgman crystal growth mechanism and the like. In an exemplary embodiment, the inverted growth reactor chamber is a U-shaped ampoule.

47 OTHER INSTRUMENTATION↗

Cosmic ray charge spectrometer.

Gas-filled Cerenkov radiation detector combined with solid detectors to measure charge and flux of relativistic cosmic rays

RELATIVISTIC PARTICLE↗

Overall View of the JEM-EUSO Instruments

JEM-EUSO mission with a large and wide-angle telescope mounted on ISS has been planned to open up 'particle astronomy' through the investigation of extreme-energy cosmic rays by detecting fluorescent and Cherenkov photons by air showers developed in the earth's atmosphere. The JEM-EUSO telescope consists of optical Fresnel lenses with a diameter of about 2.5 m, 300 k channels of MAPMT, frontend readout electronics, trigger electronics, and system electronics. An infrared camera and a LIDAR system will be used to monitor the earth's atmosphere.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The JEM-EUSO optics system

The Extreme Universe Space Observatory onboard the Japanese Experiment Module is an international mission devoted to the detection of ultra high-energy cosmic particles with energies E>7x10{sup 19} eV. They are revealed through emission in the atmosphere of Cherenkov and fluorescence light in the near-UV region, by using an optical system with 60 deg. field of view and a 2.3 m entrance pupil. One of the challenges consists in developing an unusual combination of large and lightweight refractive optics: two double-sided curved Fresnel lenses and a central curved Fresnel+diffractive lens, whose maximum dimensions are 2.65 m. This paper describes the development of such a optical system and its performances of the latest configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-Ray Localization of Terrestrial Gamma-Ray Flashes

Terrestrial gamma-ray flashes (TGFs) are very short bursts of high-energy photons and electrons originating in Earth's atmosphere. We present here a localization study of TGFs carried out at gamma-ray energies above 20 MeV based on an innovative event selection method. We use the AGILE satellite Silicon Tracker data that for the first time have been correlated with TGFs detected by the AGILE Mini-Calorimeter. We detect 8 TGFs with gamma-ray photons of energies above 20 MeV localized by the AGILE gamma-ray imager with an accuracy of {approx}5-10 deg. at 50 MeV. Remarkably, all TGF-associated gamma rays are compatible with a terrestrial production site closer to the subsatellite point than 400 km. Considering that our gamma rays reach the AGILE satellite at 540 km altitude with limited scattering or attenuation, our measurements provide the first precise direct localization of TGFs from space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CHRPR Operations Manual

The TSA Systems VM-250AGN portal monitor is a set of two pillars made to detect nuclear material in a vehicle. Each pillar contains two polyvinyl toluene (PVT) plastic gamma ray detectors and four 3 He neutron detectors, as well as a power supply and electronics to process the output from these detectors. Pacific Northwest National Laboratory (PNNL) has designed and built a continuous high-resolution PVT readout (CHRPR) for the TSA portal to allow spectral readout from the gamma and neutron detectors. The CHRPR helps differentiate between different types of radioactive material through increased spectroscopic capability and associated developments. The TSA VM-250AGN continually monitors the levels of gamma ray and neutron radiation that occur around the pillars. A presence sensor records the passage of vehicles between the two pillars. An alarm is generated when radiation levels exceed a preset alarm threshold. The outputs of the radiation detectors inside each pillar are amplified and shaped by the SCA-775 single channel analyzer unit. Information from both SCA-775 units is passed to the SC-770 detector interface module and processor in the master pillar. This module analyzers count readings, triggers any appropriate alarms, and can output timestamped measurements to a serial connection.

CHRPR Operations Manual↗

A simulation study of the ability to detect power distribution perturbations in the texas A&M TRIGA reactor with self-powered neutron detectors

Given the variety of ways that nuclear reactor core power may be perturbed, reactor operators and developers are keen on understanding the accuracy and convergence time during which perturbations in reactor power distribution may be synthesized (i.e., inferred) from an array of in-core radiation detectors. A simulation study was conducted as described herein using a highly detailed model of the Texas A&M Training, Research, Isotopes, General Atomics Reactor, in which an array of self-powered neutron detectors (SPNDs) was considered for input to the power synthesis methodology. The core power synthesis is conducted using a point-based iterative method with an iterative loop built in to ensure working equation consistency. The forward problem of SPND response to simulated perturbations in reactor power was solved for Gaussian peak-type perturbations in the reactor power distribution. These perturbations varied in variance, amplitude, and core location to assess their impact on synthesis error and to determine the number of iterations required for convergence. A relation between the unique resolvability limit and perturbation width was identified such that the maximum synthesis error increased rapidly when the peak width went beneath this limit (a width approximating half the reactor’s fuel pin-to-pin pitch); this resolvability limit is specific to the SPND configuration and fuel segmentation considered herein. The synthesis error increased linearly with perturbation peak amplitude, whereas the convergence time increased nonlinearly. Perturbations located closer to the center of the core were synthesized more accurately, albeit with a higher number of required iterations. These findings provide a qualitative and quantitative understanding of the accuracy and speed at which different types of spatial power perturbations can be resolved in light-water reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of simulated and experimentally measured detector impulse responses to pulsed x-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-toend performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BIRD Data Report from Exploration Flight Test 1

This report summarizes the data acquired by the Battery-operated Independent Radiation Detector (BIRD) during Exploration Flight Test 1 (EFT-1). The BIRD, consisting of two redundant subsystems isolated electronically from the Orion MPCV, was developed to fly on the Orion EFT-1 to acquire radiation data throughout the mission. The BIRD subsystems successfully triggered using on-board accelerometers in response to launch accelerations, acquired and archived data through landing, and completed the shut down routine when battery voltage decreased to a specified value. The data acquired are important for understanding the radiation environment within the Orion MPCV during transit through the trapped radiation belts.

Orion↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RadSim: Particle Transport Wrapper

RadSim is being developed to provide the capability to simulate radiation source emissions, interpolate results from radiation transport tools into a common format to prepare incident flux, and model radiation detector response. This software package includes wrapper API code which is utilized in the development of the second (transport) task of the RadSim project. This software package only contains tools to interface RadSim with radiation transport tools (GEANT4 and MCNP) and does not include any part of the transport source code itself. The users will need prior access to the transport tools (GEANT4 and MCNP), and can use this software package to interface with the transport tool of their choice. This software package takes the geometry file for a radiation transport problem and converts it into an input deck for the transport tools (GEANT4 and MCNP). Additionally, it also contains filters that convert the output of the transport tools to a common flux format.

Cheung, Hoi Sing↗

Transition-radiation-Compton-scattering detector for very relativistic nuclei

The paper presents the design and predicted performance of a large acceptance (2 sq m sr) transition-radiation-Compton-scattering detector system which can be used to measure energy spectra up to several thousand Gev/nucleon for nuclei with Z between 6 and 28, as well as up to 40,000 GeV/nucleon for He. The following circumstances made such a detector system practicable: (1) transition radiation output is proportional to the square of particle charge; (2) output varies at least as rapidly as the square of Lorentz factor over the range from several hundred to several thousand.

Osborne, W. Z.↗