UV Laser Radiation: Skin Hazards and Skin Protection Controls
Abstract Not Provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract Not Provided
Evidence is presented that radiated power line harmonics leak into high-altitude regions of the magnetosphere with sufficient intensity to control the starting frequencies of chorus emissions. OGO-3 data from three passes show that the starting frequencies of all measurable chorus emissions were within a few hertz of power line harmonics. It is also found that emissions detected over Western Europe were controlled by harmonics of 50 Hz; over the eastern United States and Canada by 60 Hz; and along the Alaska-New Zealand meridian by harmonics of both 50 and 60 Hz. These results indicate that man-made VLF noise plays an important role in the generation of chorus, one of the commonly observed forms of wave activity in the outer magnetosphere.
We propose a spoof surface plasmon polariton (SPP) emitter which is composed of ultrathin corrugated metallic strips, exhibiting the directional radiation property. The spoof SPP emitter provides a way to quickly convert the SPP mode to a radiated mode. By controlling phase modulations produced by the phase-gradient metasurface on the ultrathin metallic strips, we demonstrate theoretically and experimentally that spoof SPP waves are converted into spatial propagating waves with high efficiency, which are further radiated with flexible beam steering. The proposed method sets up a link between SPP waves and radiation waves in a highly controllable way, which would possibly open an avenue in designing new kinds of microwave and optical elements in engineering.
We demonstrate that the THz generation in air from a two-color pulse, composed of the fundamental and second-harmonic waves, can be coherently controlled by field-free molecular alignment. By tuning its time delay to properly match various molecular alignment revivals, the THz generation from the two-color pulse can be promoted or decreased due to the spatial cross-(de)focusing effect and the alignment-dependent ionization probabilities of the prealigned diatomic molecules in air. For the two-color pulse of orthogonally polarized fundamental and second-harmonic waves, the polarization of the generated THz radiation can be controlled by the field-free molecular alignment, which functions as a transient dynamic wave plate for the two-color pulse with different phase velocities for the orthogonally polarized field components. The plasma effect on the THz generation of the two-color pulse is also observed, leading to additional amplitude and polarization control of the THz radiation.
A control system based on a two-channel narrow-band LMS algorithm is used to isolate periodic vibration at low frequencies on a structure composed of a rigid top plate mounted on a flexible receiving plate. The control performance of distributed PVDF error sensors and accelerometer point sensors is compared. For both sensors, high levels of global reduction, up to 32 dB, have been obtained. It is found that, by driving the PVDF strip output voltage to zero, the controller may force the structure to vibrate so that the integration of the strain under the length of the PVDF strip is zero. This ability of the PVDF sensors to act as spatial filters is especially relevant in active control of sound radiation. It is concluded that the PVDF sensors are flexible, nonfragile, and inexpensive and can be used as strain sensors for active control applications of vibration isolation and sound radiation.
Hospitals often declare their waste as being 'non-radioactive'; however this material often has excessive levels of radiation caused either by an accident or lack of control. To ensure the best possible protection against the accidental receipt of radioactive materials and as a safety precaution for their employees, waste-handling companies have installed large-scale radiation portal monitors at their weigh scales or entry gates of the incinerator plant, waste transfer station, and/or landfill. Large-volume plastic scintillator-based systems can be used to monitor radiation levels at entry points to companies handling medical waste. The recent and intensive field tests together with the thousands of accumulated hours of actual real-life vehicle scanning have proven that the plastic scintillation based system is an appropriate radiation control instrument for waste management companies. The Real-Time background compensation algorithm is flexible with automatic adjustable coefficients that will response to rapidly changing environmental and weather conditions maintaining the preset alarm threshold levels. The Dose Rate correction algorithms further enhance the system's ability to meet the stringent requirements of the waste industries need for Dose Rate measurements. (authors)
To understand how variations in interface properties such as misfit-dislocation density and local chemistry affect radiation-induced defect absorption and recombination, we have explored a model system of CrxV1-x alloy epitaxial films deposited on MgO single crystals. By controlling film composition, the lattice mismatch with MgO was adjusted so that the misfit-dislocation density varies at the interface. These interfaces were exposed to irradiation and in situ results show that the film with a semi-coherent interface (Cr) withstands irradiation while V film, which has similar semi-coherent interface like Cr, showed the largest damage. Theoretical calculations indicate that, unlike at metal/metal interfaces, the misfit dislocation density does not dominate radiation damage tolerance at metal/oxide interfaces. Rather, the stoichiometry, and the precise location of the misfit-dislocation density relative to the interface, drives defect behavior. Together, these results demonstrate the sensitivity of defect recombination to interfacial chemistry and provide new avenues for engineering radiation-tolerant nanomaterials.
It is shown that the temporal modulation of a pulse from an electron-beam-controlled CO laser can be caused by the periodic modulation of losses caused by the monotonic heating of the active medium. (control of laser radiation parameters)
An acousto-optic shaper is developed for transformation of the Gaussian beam profile into almost rectangular profile. As distinct from lens devices, an acousto-optic device allows modification of the shape of the output beam in a fixed optical configuration using changes in radio control with relatively short response times of about 10 μs. The method is based on multibeam high-efficiency Bragg diffraction when the diffraction orders are overlapped with respect to angle. It is shown that the beam profile can be transformed into rectangular and more complicated profiles with an efficiency of no less than 80%. The experiments are performed using the TeO{sub 2} crystal.
The focus of work of medical physicists in 1980’s was on quality control and quality assurance. Radiation safety was important but was dominated by occupational radiation protection. A series of over exposures of patients in radiotherapy, nuclear medicine and observation of skin injuries among patients undergoing interventional procedures in 1990’s started creating the need for focus on patient protection. It gave medical physicists new directions to develop expertise in patient dosimetry and dose management. Publications creating awareness on cancer risks from CT in early part of the current century and over exposures in CT in 2008 brought radiation risks in public domain and created challenging situations for medical physicists. Increasing multiple exposures of individual patient and patient doses of few tens of mSv or exceeding 100 mSv are increasing the role of medical physicists. Expansion of usage of fluoroscopy in the hands of clinical professionals with hardly any training in radiation protection shall require further role for medical physicists. The increasing publications in journals, recent changes in Safety Standards, California law, all increase responsibilities of medical physicists in patient protection. Newer technological developments in dose efficiency and protective devices increase percentage of time devoted by medical physicists on radiation protection activities. Without radiation protection, the roles, responsibilities and day-to-day involvement of medical physicists in diagnostic radiology becomes questionable. In coming years either medical radiation protection may emerge as a specialty or medical physicists will have to keep major part of day-to-day work on radiation protection. Learning Objectives: To understand how radiation protection has been increasing its role in day-to-day activities of medical physicist To be aware about international safety Standards, national and State regulations that require higher attention to radiation protection than in past To be aware about possible emergence of medical radiation protection as a specialty and challenges for medical physicists.
Key cable knowledge gaps identified in the Expanded Materials Degradation Assessment (EMDA) volume on Aging of Cables and Cable Systems (Volume 5) specifically relate to the combined effects of thermal and gamma irradiation stresses on cable insulation materials. These include dose rate effects (DRE), inverse temperature effects (ITE), and synergistic effects (S/E). Extent of radiation-induced polymer degradation is proportional to absorbed dose, but DRE describe the phenomenon in which degree of damage is based not only on total dose, but also on the dose rate experienced during dose accumulation. This can be particularly complicated in the presence of thermal stress as a material spends more time at elevated temperature to receive the same total dose at a lower dose rate. Rates of cable polymer degradation generally increases with temperature, but ITE describes the situation in which polymer material damage under irradiation is greater at lower temperatures than at higher temperatures. Finally, S/E describe the concept that the mechanism of polymer material degradation when exposed to thermal aging and radiation aging in succession may be different than when exposed to thermal and radiation aging concurrently. The experimental campaign at the Pacific Northwest National Laboratory (PNNL) described in this report seeks to address these knowledge gaps through investigation of the degradation of relevant cable insulation materials at select conditions using controlled temperatures, dose rates and total doses. Insulation materials considered were chosen to represent those most commonly found in U.S. nuclear power plants in terms of manufacturers and polymer systems. They include products from manufactures including The Rockbestos Company; The Okonite Company; Boston Insulated Wire & Cable Company; Kerite Company; Anaconda Company; Brand Rex, Inc.; and Samuel Moore Company. The products include the most ubiquitous cross-linked polyethylene (XLPE) and ethylene-propylene rubber (EPR) classes of insulation polymer. Circulating air ovens with remote temperature sensing and control are positioned within the gamma irradiation beam to enable controlled temperatures during radiation exposure. Dose rates are controlled through repeatable positioning of specimens at determined distances from the Cobalt-60 gamma source. Total absorbed doses for comparing temperature and dose rate effects are controlled by removing samples from exposure at pre-determined time points. The effects of gamma beam geometry, source decay and attenuation due to samples, ovens and racks are determined and controlled for using local point dosimetry. The temperature, dose and dose rates selected for the experimental campaign described in this report were determined following input from a range of stakeholders and intended to balance the constraints of the experimental capabilities, available material, project timeline and project funding with the value of the effort in narrowing EMDA-identified knowledge gaps. Results from this campaign are anticipated to reduce uncertainty in the understanding of cable material degradation behavior in nuclear power plant environments and thereby support cable aging management in long term operation.
Purpose: To assess the effects of noscapine, a tubulin-binding drug, in combination with radiation in a murine glioma model. Methods and Materials: The human T98G and murine GL261 glioma cell lines treated with noscapine, radiation, or both were assayed for clonogenic survival. Mice with established GL261 hind limb tumors were treated with noscapine, radiation, or both to evaluate the effect of noscapine on radioresponse. In a separate experiment with the same treatment groups, 7 days after radiation, tumors were resected and immunostained to measure proliferation rate, apoptosis, and angiogenic activity. Results: Noscapine reduced clonogenic survival without enhancement of radiosensitivity in vitro. Noscapine combined with radiation significantly increased tumor growth delay: 5, 8, 13, and 18 days for control, noscapine alone, radiation alone, and the combination treatment, respectively (p < 0.001). To assess the effect of the combination of noscapine plus radiation on the tumor vasculature, tubule formation by the murine endothelial 2H11 cells was tested. Noscapine with radiation significantly inhibited tubule formation compared with radiation alone. By immunohistochemistry, tumors treated with the combination of noscapine plus radiation showed a decrease in BrdU incorporation, an increase in apoptosis by terminal deoxynucleotidyl transferase-mediated deoxyuridine triphosphate nick end labeling, and a decrease in tumor vessel density compared with tumors treated with radiation alone. Conclusion: Noscapine enhanced the sensitivity of GL261 glioma tumors to radiation, resulting in a significant tumor growth delay. An antiangiogenic mechanism contributed to the effect. These findings are clinically relevant, particularly in view of the mild toxicity profile of this drug.
Main parameters of a new scheme of a compact VUV grazing incidence spectrometer based on a plane amplitude diffraction grating are considered. The spectrometer will allow simultaneous detection of spectra at the +1st order diffraction edge with a sufficiently high ( λ/δ λ ∼ 150) spectral resolution and in the –1st order with a moderate resolution ( λ/δ λ ∼ 15 – 30), but in a very wide (5 – 200 nm) spectral range. The use of such a spectrometer is promising for measuring the absolute radiation yield in these spectral regions, which is necessary for the diagnostics and control of plasma radiation sources, including those intended for projection EUV nanolithography. (vuv spectroscopy)
Individual current feeds enable better uniformity and flexible control. Separate contacts for lasers in array enable control of output radiation pattern and compensation of manufacturing nonuniformities among lasers. Concept of separate current control described for two-laser array in "Semiconductor Laser Phased Array" (NPO-15963).
An analysis of the experiments on the kinetics of the rise and decay of the current under the influence of extreme ultraviolet radiation on the indium–zinc oxide filament layer obtained by the electrospinning method is given. It is shown that the rate of rise of photocurrent is controlled by the radiation intensity and its decay rate is controlled by the partial pressure of oxygen on the surface of the wires. Owing to a significantly larger area of the active surface, this UV sensor with a layer of nanoscale wires has a shorter response time in comparison with homogeneous film structures in which the oxygen adsorption sites are concentrated.
Tests were designed to investigate the validity of the "modular" approach to space radiator system design for space shuttle and future applications by gathering performance data on various systems comprised of different numbers of identical panels, subject to nominal and extreme heat loads and environments. Both one-sided and two-sided radiation was tested, and engineering data was gathered on simulated low a/e coatings and system response to changes in outlet temperature control point. The results of the testing showed system stability throughout nominal orbital transients, unrealistically skewed environments, freeze-thaw transients, and rapid changes in outlet temperature control point. Various alternative panel plumbing arrangements were tested with no significant changes in performance being observed. With the MRS panels arranged to represent the shuttle baseline system, a maximum heat rejection of 76,600 Btu/hr was obtained in segmented tests under the expected worst case design environments. Testing of an alternate smaller two-sided radiation configuration yielded a maximum heat rejection of 52,931 Btu/hr under the maximum design environments.
Active control of sound radiation from vibrating plates by oscillating forces applied directly to the structure is analytically studied. The model consists of a plane acoustic wave incident on a clamped elastic circular thin plate. Control is achieved by point forces, and quadratic optimization is used to calculate the optimal control gains necessary to minimize a cost function proportional to the radiated acoustic power (the transmitted field). The results show that global attenuation of broadband radiated sound levels for low to mid-range frequencies can be achieved with one or two control forces, irrespective of whether the system is on or off resonance. The efficiency of the control strategy is demonstrated to be related to the nature of the coupling between the plate modes of response and the radiated field.
Four advanced space radiator concepts that were pursued in an integrated effort to develop multi-mission-use and low cost heat rejection systems which can overcome the limitations of current radiator systems are briefly discussed and described. Also, in order to establish a firm background to compare the advanced space radiator concepts, the Orbiter active thermal control system is also briefly described.