The estimation of galactic cosmic ray penetration and dose rates

This study is concerned with approximation methods that can be readily applied to estimate the absorbed dose rate from cosmic rays in rads - tissue or rems inside simple geometries of aluminum. The present work is limited to finding the dose rate at the center of spherical shells or behind plane slabs. The dose rate is calculated at tissue-point detectors or for thin layers of tissue. This study considers cosmic-rays dose rates for both free-space and earth-orbiting missions.

Burrell, M. O.↗

Spectral structure of the diffuse X-ray sky

A description of diffuse celestial X-ray flux is drawn from data taken by rocket borne detectors. It was concluded that the diffuse flux is intra- and extra-galactic in origin and is caused by Compton scattering of .052 rad black body photons of relativistic electrons leaking out of the galaxies.

Boldt, E. A.↗

Niobium hyperfine structure in crystal calcium tungstate

A study of the niobium hyperfine structure in single crystal calcium tungstate was made by the combination of the technique of electron paramagnetic resonance and electron nuclear double resonance (EPR/ENDOR). The microwave frequency was about 9.4 GHz and the radio frequency from 20MHz to 70 MHz. The rare earth ions Nd(3+), U(3+), or Tm(3+) were added as the charge compensator for Nb(5+). To create niobium paramagnetic centers, the sample was irradiated at 77 deg K with a 10 thousand curie Co-60 gamma source for 1 to 2 hours at a dose rate of 200 K rads per hour and then transferred quickly into the cavity. In a general direction of magnetic field, the spectra showed 4 sets of 10 main lines corresponding to 4 nonequivalent sites of niobium with I = 9/2. These 4 sets of lines coalesced into 2 sets of 10 in the ab-plane and into a single set of 10 along the c-axis. This symmetry suggested that the tungsten ions are substituted by the niobium ions in the crystal.

Tseng, D. L.↗

Testing superalloys at 2000 (1367) and 2200 F (1478 K) in a Mach 4.6 airstream

Seven superalloy models were tested in a plasma arc tunnel facility. The test models were 3 in. (7.62cm) square flat surfaces (nominally 0.01 to 0.02 in. (0.0254 to 0.0508 cm) thick) held in a water-cooled wedge holder at a 60 deg (1.05 rad) angle of attack. The models were cycled 25 times (two were cycled 50 times) for 10 min each cycle in a Mach 4.6 test stream with the model leading edge temperature maintained at 2200 F (1478 K) (one at 2000 F (1367 K)). Backface temperatures were measured with four platinum-platinum 10% rhodium thermocouples and the front surface temperatures with an optical pyrometer. Four different nickel base alloy materials and one cobalt material were evaluated.

Land, D. W.↗

Electron and proton flux models for Jupiter's radiation belts

Estimates of the energetic particle distribution in Jupiter's radiation belts are presented and are compared with previous estimates. Mathematical expressions are developed for the equatorial electron and proton fluxes, shielded electron and proton dose rates, and radiation lifetimes of electronic circuits. It is calculated that a 1 g/sq cm aluminum shield will screen out all protons of energy less than 27.5 MeV, and a 2 g/sq cm shield will screen out protons less than 40.6 MeV. The radiation lifetimes are based on a maximum permissible dose value of 10 million rads, a value 1/2 to 1/3 of the flux at which electronic circuits begin to fail. Estimated increases in lifetimes by using a 3 x 50 orbit instead of a 3 x 3 orbit, and going from 1 to 2 g/sq cm are given.

Klopp, D. A.↗

Inhaled ozone as a mutagen. II - Effect on the frequency of chromosome aberrations observed in irradiated Chinese hamsters.

Exposure-adjusted break frequencies for chromosome aberrations produced in Chinese hamster circulating blood lymphocytes were the quantitative indicator of damage from 5 hrs of exposure to X-radiation and/or to ozone. Radiation produced 5.51 x 0.0001 breaks/cell rad for cells withdrawn 2 weeks after exposure, a reasonable value when compared with data from in vivo exposure of human lymphocytes and Chinese hamster bone marrow cells. Animals exposed to the two agents simultaneously exhibited more than 70% of the total breaks anticipated assuming the expected equal contributions to be additive. Extending to humans, at presently permitted levels, exposure to ozone would be much more detrimental than exposure to radiati*n.

Zelac, R. E.↗

Gamma ray emission from the region of the galactic center

A combination nuclear emulsion-spark chamber gamma ray (E=100 MeV) telescope was used to study the region of sky that includes the Galactic Center. 95% confidence upper limits on the flux from the reported sources G gamma 2 - 3 and Sgr gamma-1 were placed at 4.4 and 8.8 x 10 to the minus 5th power protons/sq cm-sec, and a similar limit on the emission from the Galactic Center as a point source (plus or minus .75 degrees) was placed at 3.3 x 10 to the minus 5th power protons/sq cm-sec. No enhanced emission was observed from the Galactic Plane (plus or minus 6 degrees) and an upper limit of 2 x 10 to the minus 4th power protons/sq cm-sec rad/ was obtained.

Dahlbacka, G. H.↗

NERVA turbopump bearing retainer fabrication on nonmetallic retainer

The need for a low-wear, lightweight, high strength bearing retainer material with a radiation degradation threshold of 10 to the 9th power rads (C) prompted development of nonmetallic reinforced polymers of the following types: (1) polybenzimidazole, (2) polyimide, and (3) polyquinoxaline. Retainers were machined from tubular laminates (billets), including reinforcement by either glass or graphite fabric or filament. Fabrication of billets involves hot preimpregnation of the reinforcement fabric or filament with polymer followed by wrapping this prepreg over a heated mandrel to form a tube with the required thickness and length.

Accinelli, J. B.↗

Proton dosimeter design for distributed body organs.

The design of a real-time rem-rad dosimeter with sufficient generality for inclusion of dose distribution factors for space applications is discussed. This generalized dosimetric system is only slightly more complex than dosimeters in current use.

Khandelwal, G. S.↗

Proton tissue dose for the blood forming organ in human geometry: Isotropic radiation

A computer program is described which calculates doses averaged within five major segments of the blood forming organ in the human body taking into account selfshielding of the detailed body geometry and nuclear star effects for proton radiation of arbitrary energy spectrum (energy less than 1 GeV) and isotropic angular distribution. The dose calculation includes the first term of an asymptotic series expansion of transport theory which is known to converge rapidly for most points in the human body. The result is always a conservative estimate of dose and is given as physical dose (rad) and dose equivalent (rem).

Khandelwal, G. S.↗

Study of a number of biochemical indices of the blood and tissue of dogs after prolonged gamma-radiation

The glucose content in blood and the lipid content in serum and tissues of dogs exposed to chronic radiation for 3 and 5 years were studied. In tissues of these animals, the concentration of soluble DNA and DNA contained in DNP was studied in the spleen, lymph node (deep cervical node) and bone marrow of thigh bones. Results indicate that chronic gamma irradiation significantly changes concentrations of glucose in the blood, and that of several lipids in serum and tissues. A reduction in the concentration of DNP in tested organs reflects changes in the relative number of cells with various nuclear cytoplasmic ratios; most pronounced changes in biochemical indices occur in dogs exposed to chronic gamma radiation in doses of 125 rad per year.

Alers, I.↗

The temporal organization of processes of cell reproduction and its connection with rhythms of radiosensitivity of the body

Radiosensitivity of individual phases of the mitotic cycle was studied in synchronous cell cultures and in several biological objects. It was found that radiosensitivity changed essentially according to phases of the mitotic cycle, depending on the kind of cells, evaluation criteria and the radiation dosage. Tests on partially synchronized HeLa cell populations, according to the criterion of survival, showed them most sensitive during mitosis, as well as in later G sub 1- or early DNA-synthesizing stages. With radiation in doses of 300 rad, the proportion of surviving cells showed a sensitivity directly before DNA synthesis of approximately 4 times higher than the later S-phase and during the major portion of G sub 1- and G sub 2-periods. Sensitivity of cells in mitosis was approximately 3 times higher than in late G sub 1- and early S-phases.

Druzhinin, Y. P.↗

Thermal and radiation damage to SL/1 EREP films

Tests were conducted to determine the present sensitometric characteristics of the SL/1 EREP films stored in Skylab. These films underwent the high temperature environment at the beginning of the mission and have since been stored outside the film vault. As a result, the films will have received a radiation dose estimated at approximately 12 rads by the end of SL/3.

Perry, L.↗

Experiments on the use of CCD's to detect photoelectron images

Image tube design and processing requirements for building an ICCD are discussed. Work is under way at EVC for building an ICCD using the Fairchild CCD 201 (100 x 100) array, and progress will be reported. Demountable tests have been made, exposing parts of a CCD 201 to 15 kilovolt electrons over five radiation levels from approximately 10 to 1 million rads. Other tubes built by EVC over the last few years which successfully use semiconductors to detect photoelectrons will be described briefly.

Choisser, J. P.↗

Effects of radiation on charge-coupled devices

The effects of 1 MeV electron irradiation upon the performance of two phase, polysilicon aluminum gate CCDs are reported. Both n- and p-surface channel and n-buried channel devices are investigated using 64- and 128-stage line arrays. Characteristics measured as a function of radiation dose include: Transfer inefficiency, threshold voltage, field effect mobility, interface state density, full well signal level and dark current. Surface channel devices are found to degrade considerably at less than 10 to the 5th power rads (Si) due to the large increase in fast interface state density caused by radiation. Buried channel devices maintain efficient operation to the highest dose levels used.

Carnes, J. E.↗

The Pioneer 10/11 and Helios A/B cosmic ray instruments

This paper describes the design and performance of a set of cosmic-ray particle experiments for the Pioneer 10/11 and Helios A/B space missions. These experiments had to be very light-weight, low-power and electronically sophisticated in order to meet the spacecraft and scientific requirements. Both sets of missions use several solid-state detector telescopes to measure protons from 100 KeV to 800 MeV and heavier ions up to Neon at 200 MeV per nucleon. Good performance is required for 7-8 years, and the system must tolerate large vibration loads and ionizing radiation doses up to 500,000 rads.

Stilwell, D. E.↗

Effect of electron irradiation in vacuum on FEP-A silicon solar cell covers

The effect of irradiation on the light transmittance of ethylene-propylene-A (FEP-A) was investigated by measuring the short-circuit current of the cells after each of several electron dose increments, immediately after total irradiation, and 16 hours after total irradiation. Results indicated no apparent overall loss in transmission due to irradiation of FEP-A. However, filter wheel measurements revealed a 'darkening' of the FEP-A at the blue end of the spectrum. Some embrittlement of the FEP-A occurred at an accumulated dose of 67,500,000 rads.

Marsik, S. J.↗

Technical and Economic Assessment of Span-Distributed Loading Cargo Aircraft Concepts

A 700,000 kg (1,540,000-lb) aircraft with a cruise Mach number of 0.75 was found to be optimum for the specified mission parameters of a 272 155-kg (600,000-lb) payload, a 5560-km (3000-n.mi.) range, and an annual productivity of 113 billion revenue-ton km (67 billion revenue-ton n. mi.). The optimum 1990 technology level spanloader aircraft exhibited the minimum 15-year life-cycle costs, direct operating costs, and fuel consumption of all candidate versions. Parametric variations of wing sweep angle, thickness ratio, rows of cargo, and cargo density were investigated. The optimum aircraft had two parallel rows of 2.44 x 2.44-m (8 x 8-ft) containerized cargo with a density of 160 kg/cu m (10 lb/ft 3) carried throughout the entire 101-m (331-ft) span of the constant chord, 22-percent thick, supercritical wing. Additional containers or outsized equipment were carried in the 24.4-m (80-ft) long fuselage compartment preceding the wing. Six 284,000-N (64,000-lb) thrust engines were mounted beneath the 0.7-rad (40-deg) swept wing. Flight control was provided by a 36.6-m (120-ft) span canard surface mounted atop the forward fuselage, by rudders on the wingtip verticals and by outboard wing flaperons.

Johnston, W. M.↗