Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Characterizing the AFP Spin Flipper for the Nab Experiment

The Nab experiment at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) aims to yield a precise measurement of the electron-neutrino correlation parameter, a , to $\frac{Δa}{a}$ = 1 × 10 −3 from the beta-decay of the free neutron. To achieve Nab’s precision goal, polarization of the neutron beam must be near-zero. A polarizer/analyzer combination, neutron monitors, and an Adiabatic Fast Passage (AFP) spin flipper will be used to determine a beam polarization effectively less than 2 × 10 −5 . Here, I will discuss the initial characterization efforts of the Nab spin flipper as well as plans for further testing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of STARFLEET Velocimetry in the NASA Langley 0.3-Meter Transonic Cryogenic Tunnel

Selective two-photon absorptive resonance femtosecond laser electronic excitation tagging (STARFLEET) velocimetry is demonstrated for the first time in a NASA Langley wind tunnel with high repetition-rate and single-shot imaging. Experiments performed in the 0.3-meter Transonic Cryogenic Tunnel (TCT) allowed for testing at 300 K over a range of pressures (124 to 517 kPa) and Mach numbers (0.2-0.8) for freestream conditions and flow behind a cylindrical model. Measurement precision and accuracy are determined for the current set of experiments, as are signal intensity and lifetime. Precisions of 3-5 m/s (based on one standard deviation) were typical in the experiment; precisions better than 2% of the mean velocity were obtained for some of the highest velocity conditions. Agreement within a mean error of 3 m/s between STARFLEET freestream velocity measurements and facility DAS readings is demonstrated. STARFLEET is also shown to return spatially-resolved velocity profiles, though some binning of the signal is required.

STARFLEET↗

The Jefferson Lab tritium program of nucleon and nuclear structure measurements

In this work a series of experiments were performed in Hall A of Jefferson Lab in 2018 that used a novel tritium and helium-3 target system. These experiments took advantage of the isospin symmetry of these mirror nuclei to make precise measurements of isospin dependence in both nucleon and nuclear structure. We summarize here the design and properties of these cells, the physics measurements that have been published, and results currently under analysis from this program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of β -delayed proton emitters in the region of 100 Sn

An experiment on neutron-deficient nuclei in the region of doubly magic 100 Sn was carried out at the Radioactive Ion Beam Factory (RIBF) at the RIKEN Nishina Center in Japan. 𝑁 ≈ 𝑍 ≈ 50 nuclei were produced following fragmentation of an intense primary 124 Xe beam and implanted in the Advanced Implantation Detector Array silicon setup for the first study of proton-rich nuclei with this system at RIKEN. Measurements of the 𝛽-delayed proton emitter decay half-lives, branching ratios and proton energy spectra of nuclei in the region of 100 Sn were performed, with improved precision in many cases. New results for the energy spectrum of 101 Sn are presented, where a 2.03(5)-MeV peak was observed. In conclusion, these results are compared to shell-model calculations, using the recent precise measurement of the 101 In proton separation energy are presented.

Appleton, C. J. [Univ. of Edinburgh, Scotland (Uni↗

Remote sensing of atmospheric pollutant gases using an infrared heterodyne spectrometer

Remote sensing of the concentration and vertical distribution of atmospheric gases using an infrared heterodyne spectrometer (IHS) has been investigated, and a dual (C-13)(O-16)2 laser multichannel IHS has been developed. Analyses of nadir thermal-radiance measurements from an aircraft at 10-km altitude and of solar absorption measurements from the ground indicate that initial applications of the IHS to tropospheric measurements of NH3 and O3 are feasible with measurement precisions ranging from 0.5 to 2 ppb and 20 to 30 ppb, respectively. These analyses have included effects of potential retrieval-error sources and have resulted in specifications of measurement modes, optimum signature lines, required system parameters, and expected sensitivities. Preliminary instrument performance data are presented.

Seals, R. K., Jr.↗

Seasat-A - An ocean observation satellite

Mission details, onboard equipment, and measurements to be taken are described for the Seasat-A global ocean monitoring satellite. The satellite is designed for mapping the global ocean geoid, charting ice fields and leads, precision measurement of sea surface topography, global monitoring of wave height and wave directional spectra, surface winds and wind direction, current patterns, and ocean temperature. Data handling subsystems, a compressed pulse radar altimeter, coherent synthetic aperture imaging radar, microwave wind scatterometer, scanning visible/IR radiometer, scanning multispectral (5 freq) microwave radiometer mounted on the satellite are described briefly.

Williams, F. L.↗

SULI Internship Deliverables (Flow Orifice Design: Measuring Degas Flow of Experiment Loops at the Advanced Test Reactor)

These deliverables present a design for a new orifice flow meter to be installed in three experiment loops at the Advanced Test Reactor. The current configuration of the experiment loop system has an orifice that is not properly sized to the low flow rates of the degas line of the pressurizer system, causing inaccurate flow measurements. Under consideration of flow conditions and system constraints, an iterative procedure was utilized to determine the optimal sizing for a new orifice. This orifice is designed to accurately and precisely measure the flow rate of the degas line, which will consequently improve control of the pressure and chemistry of the loop pressurizer system. The scope of this project includes recommendations for orifice sizing, material, flange type, face type, and installation location on the loop piping spools. The design is suitable for experiment loops 1D-N, 2B-SE, and 2D-SW and meets all necessary standards.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The INTEGRAL scatterometer SPI

The INTErnational Gamma Ray Astrophysics Laboratory (INTEGRAL) mission's onboard spectrometer, the INTEGRAL spectrometer (SPI), is described. The SPI constitutes one of the four main mission instruments. It is optimized for detailed measurements of gamma ray lines and for the mapping of diffuse sources. It combines a coded aperture mask with an array of large volume, high purity germanium detectors. The detectors make precise measurements of the gamma ray energies over the 20 keV to 8 MeV range. The instrument's characteristics are described and the Monte Carlo simulation of its performance is outlined. It will be possible to study gamma ray emission from compact objects or line profiles with a high energy resolution and a high angular resolution.

Mandrou, P.↗

Charged Current Single Pion Production on SBND

The Short Baseline Neutrino (SBN) program at Fermilab is designed to provide precise measurements of neutrino oscillations using 3 Liquid Argon Time Projection Chambers (LArTPC) built along Fermilab's Booster Neutrino Beam (BNB). The Short Baseline Near Detector (SBND), located at only 110 m from the BNB target, will precisely characterize the neutrino flux before oscillations take place, thanks to its unprecedented neutrino interaction statistics. Due to its proximity to the neutrino production target, the detector expects over a million neutrino interactions annually, which will open the possibility of exploring exclusive channels of neutrino interactions. This poster will show SBND’s capabilities of exploring Muon Neutrino Charged Current Single Pion production, for which previous measurements in Argon were limited by statistics. The poster will introduce the relevance of this process for neutrino Physics, the unique possibilities of SBND and a preliminary event selection using SBND's current reconstruction tools.

43 PARTICLE ACCELERATORS↗

Measurement of the branching fractions of the decays Λ c + → Λ K S 0 K + , Λ c + → Λ K S 0 π + , and Λ c + → Λ K * +

Studies are performed of the Cabibbo-favored decay Λ c + → Λ K S 0 K + and the singly Cabibbo-suppressed decay Λ c + → Λ K S 0 π + , based on a sample of e + e − collision data, corresponding to an integrated luminosity of 4.5 fb − 1 , accumulated at center-of-mass energies between 4599.53 MeV and 4698.82 MeV with the BESIII detector. The decay Λ c + → Λ K S 0 π + is observed for the first time. The branching fractions of Λ c + → Λ K S 0 K + and Λ c + → Λ K S 0 π + are measured to be ( 3.04 ± 0.30 ± 0.16 ) × 10 − 3 and ( 1.73 ± 0.27 ± 0.10 ) × 10 − 3 , respectively, where the first uncertainties are statistical and the second are systematic. These results correspond to the most precise measurement of these quantities for both decays. Evidence of a K * + contribution in the Λ c + → Λ K S 0 π + decay is found with a statistical significance of 4.71 σ . The branching fraction of Λ c + → Λ K * + is calculated under three possible interference scenarios, with the significance increasing to 5.03 σ when interference is taken into account. Published by the American Physical Society 2025

Ablikim, M.↗

Phase and contrast moiré signatures in two-dimensional cone beam interferometry

Neutron interferometry has played a distinctive role in fundamental science and characterization of materials. Moiré neutron interferometers are candidate next-generation instruments: they offer microscopy-like magnification of the signal, enabling direct camera recording of interference patterns across the full neutron wavelength spectrum. Here we demonstrate the extension of phase-grating moiré interferometry to two-dimensional geometries. Our fork-dislocation phase gratings reveal phase singularities in the moiré pattern, and we explore orthogonal moiré patterns with two-dimensional phase gratings. Our measurements of phase topologies and gravitationally induced phase shifts are in good agreement with theory. These techniques can be implemented in existing neutron instruments to advance interferometric analyses of emerging materials and precision measurements of fundamental constants. Published by the American Physical Society 2024

Sarenac, D. (ORCID:0000000185753367)↗

Bayesian Fit to NOvA Data Subsamples for Three Flavor Oscillation Analysis

NOvA (NuMI Off-Axis $\nu_e$ Appearance) is a long baseline neutrino experiment designed to measure the oscillation of muon neutrinos to electron neutrinos over a distance of 810 km. NOvA uses a near and far detector to observe $\nu_\mu$ disappearance and $\nu_e$ appearance of neutrinos produced by the NuMI beam at Fermilab. NOvA uses a Bayesian analysis framework in addition to its Frequentist method to measure neutrino oscillation parameters such as the mixing angles, mass ordering, and CP-violating phase. We report preliminary results of Bayesian fits to representative NOvA datasets. Comparison of fits to $\nu_\mu$ disappearance and $\nu_e$ appearance enables a cross-check of NOvA results with reactor $\bar{\nu_e}$ disappearance measurements. NOvA also searches for violation of Lorentz invariance by analyzing fits of forward horn current (FHC) versus reverse horn current (RHC) samples. The results validate and advance NOvA's contributions to precision measurements of neutrino properties.

Zhao, Larry [Fermilab]↗

Neutrino Oscillation Results from the NOvA Experiment

The NOvA experiment is a long-baseline accelerator-based neutrino oscillation experiment that uses the upgraded NuMI beam from Fermilab to measure electron-neutrino appearance and muon-neutrino disappearance between the Near Detector, located at Fermilab, and the Far Detector, located at Ash River, Minnesota. NOvA's primary physics goals include precision measurements of oscillation parameters, such as $\theta_{23}$ and the atmospheric mass-squared splitting, along with probes of the mass hierarchy and of the CP-violating phase. This talk will cover NOvA’s most recent three-flavor oscillation results, based on a neutrino beam exposure of 13.6E20 protons-on-target and an anti-neutrino beam exposure of 12.5E20 protons-on-target.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraining the Halo Mass of Damped Lyα Absorption Systems (DLAs) at z = 2–3.5 Using the Quasar-CMB Lensing Cross-correlation

We study the cross-correlation of damped Lyα systems (DLAs) and their background quasars, using the most updated DLA catalog and the Planck 2018 CMB lensing convergence field. Our measurement suggests that the DLA bias b DLA is smaller than 3.1, corresponding to log (M/M ⊙ h -1 ) ⩽ 12.3 at a confidence of 90%. These constraints are broadly consistent with Alonso et al. and previous measurements by cross-correlation between DLAs and the Lyα forest (e.g., Font-Ribera et al.; Prez-Rfols et al.). Further, our results demonstrate the potential of obtaining a more precise measurement of the halo mass of the high-redshift sources using next generation CMB experiments with a higher angular resolution. The python-based codes and data products of our analysis are available at https://github.com/LittleLin1999/CMB-lensingxDLA.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical Polarization as a Probe of the Local Interstellar Medium

The use of interstellar polarization as a tool for measuring interstellar dust is discussed. Problems resulting from dust and magnetic field configurations becoming mixed up are discussed, as is the availability of sufficiently bright stars to obtain the photons needed for precision measurements. It is proposed that: (1) on the scale of several hundred parsec, there is a preferential magnetic field direction, as evidenced by observations at the Galactic poles and selected longitudes in the Galactic plane; (2) the local (r 50 pc) region is devoid of dust, as evidenced by the mean square degree of polarization as a function of distance; and, less certainly, that (3) at a distance of less than 5 pc, there is a patch of dust which may be of interest in connection with cloud models.

Tinbergen, J.↗

The Atacama Cosmology Telescope: Beam Measurements and the Microwave Brightness Temperatures of Uranus and Saturn

We describe the measurement of the beam profiles and window functions for the Atacama Cosmology Telescope (ACT), which operated from 2007 to 2010 with kilopixel bolometer arrays centered at 148, 218, and 277 GHz. Maps of Saturn are used to measure the beam shape in each array and for each season of observations. Radial profiles are transformed to Fourier space in a way that preserves the spatial correlations in the beam uncertainty to derive window functions relevant for angular power spectrum analysis. Several corrections are applied to the resulting beam transforms, including an empirical correction measured from the final cosmic microwave background (CMB) survey maps to account for the effects of mild pointing variation and alignment errors. Observations of Uranus made regularly throughout each observing season are used to measure the effects of atmospheric opacity and to monitor deviations in telescope focus over the season. Using the WMAP-based calibration of the ACT maps to the CMB blackbody, we obtain precise measurements of the brightness temperatures of the Uranus and Saturn disks at effective frequencies of 149 and 219 GHz. For Uranus we obtain thermodynamic brightness temperatures T(149/U) = 106.7 +/- 2.2 K and T(219/U) = 100.1 +/- 3.1 K. For Saturn, we model the effects of the ring opacity and emission using a simple model and obtain resulting (unobscured) disk temperatures of T(149/S) = 137.3 +/- 3.2 K and T(219/S) = 137.3 +/- 4.7 K.

Atacama Cosmology Telescope (ACT)↗

Proton Scattering in NOvA Test Beam

The NuMI Off-axis $\nu_e$ Appearance (NOvA) experiment is a two-detector, long baseline, neutrino oscillation experiment, which aims to make a determination of the neutrino mass ordering, the octant of $\theta_{23}$, and measure possible charge-parity (CP) violation. Determining these parameters is a step towards answering some of the fundamental questions about neutrinos. Are neutrinos their own antiparticle? Could neutrinos be responsible for the matter-antimatter asymmetry of the universe? How do neutrinos get their mass? Answering these questions requires precise measurements of the parameters that govern how neutrinos behave, namely the mass squared splittings, mixing angles, and possible CP-violating phase factor in the PNMS matrix. Reaching high precision requires minimizing both statistical and systematic errors. As NOvA continues to accumulate data, the sizes of our statistical errors continue to shrink such that in a couple of years they will be comparable to our systematic errors. NOvA's current systematic errors are dominated by energy and calibration uncertainties. The Test Beam program was initiated to address these uncertainties by assessing the detector response in an environment where more parameters of the incoming particles are known. One of the main goals of the Test Beam program is to garner a better understanding of our systematic errors, particularly in energy measurement and detector response, so that the modeling of these parameters can be improved. I studied protons in the Test Beam Detector with momenta around \unit[1]{GeV/c}, the high end of the momentum range relevant to quasielastic neutrino interactions in NOvA. One question this sample can help to answer is if we correctly simulate the fraction of protons that have an inelastic scattering interaction versus ranging out. If protons inelastically scatter at different rates in our simulation and data, the correction applied to the hadronic system when reconstructing neutrino energy could be inaccurate, since events with inelastic scattering will have less visible energy in the detector. This is particularly important for quasielastic $\nu_\mu$ events, which have the lowest hadronic energy resolution, and therefore give us our best measurements of $\Delta m_{32}^2$ and $\theta_{23}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Atomic clocks for astrophysical measurements

It is noted that recently developed atomic hydrogen masers have achieved stability well into the 10 to the -16th domain for averaging time intervals beyond 1000 sec and that further improvements are in prospect. These devices are highly adaptable for space use in very high precision measurements of angle through Very Long Baseline Interferometry (VLBI) and of range and range-rate through Doppler techniques. Space missions that will use these clocks for measuring the sun's gravity field distribution and for testing gravitation and relativity (a project that will include a search for pulsed low-frequency gravitational waves) are discussed. Estimates are made of system performance capability, and the accuracy capability of relativistic measurements is evaluated in terms of the results from the 1976 NASA/SAO spaceborne clock test of the Einstein Equivalence Principle.

Vessot, R. F. C.↗