Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Polymer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Thermomechanical design optimization for low metal footprint in hybrid metal-polymer heat exchanger

Material and maintenance costs of metal-based heat exchangers surpass profits in waste heat recovery (WHR) from ultra-low temperature (<100C) sources [1]. A low-cost alternative like polymer pipes suffer from poor thermal conductivity (~0.2 W/mK), and a low overall heat transfer coefficient. Polymers’ thermal conductivity have previously been enhanced through systematic molecular alignment by stretching [2], chemical vapor deposition of extended polymers [3], surface grating [4], etc. However, these approaches suffer from scalability issues for WHR heat exchangers in terms of cost [3], and thermomechanical considerations [5]. In this work, we propose novel hybrid metal-polymer heat exchangers that are made from polymer-copper strips. Through finite element method (FEM) simulations, we first optimize the placement of copper around polymer strips to enhance the transverse thermal conductivity of the strips. The copper cladded polymer strips are wound helically in a roll-to-roll system to form the pipes for a heat exchanger. We then optimize the design of helically wound pipes to reduce thermomechanical strains to < 0.2 % at 100C and 40 psi working conditions. At 25 % volume fraction of copper in the pipe, we predict up to 20 % enhancement in overall heat transfer from a base polymer with a thermal conductivity of 0.2 W/mK. We also compare and contrast the thermomechanical performance of the optimized metal-polymer strips to random metal matrix composites. Finally, we experimentally verify the thermal conductivity of the optimized strips through bulk thermal conductivity and thermal interface resistance measurement setup. By systematically improving the design through FEM and experimental measurements, we provide an optimized design of hybrid metal-polymer pipes that provides a low metal footprint and cost-effective means for harvesting waste heat from ultra-low temperature sources. Thekdi, Arvind, and Sachin U. Nimbalkar. Oak Ridge National Lab, 2015 Shen, Sheng, et al. Nature nanotechnology 5.4 (2010): 251. Xu, Yanfei, et al. Science advances 4.3 (2018): 3031. Smith, M. K., Singh, V., Kalaitzidou, K., & Cola, B. A. (2015). ACS nano, 9(2), 1080-1088. Aymonier, C., Bortzmeyer, D., Thomann, R., & M&uuml;lhaupt, R. (2003). Chemistry of Materials, 15(25), 4874-4878.

C Rajagopal, Manjunath↗

Compatibility of polymers in super-critical carbon dioxide for power generation systems: High level findings for low temperatures and pressure conditions

Polymers such as PTFE (polytetrafluorethylene or Teflon), PEEK (polyetheretherketone), EPDM (ethylene propylene cliene monomer) rubber, Viton, EPR (ethylene propylene rubber), Nylon, Nitrile rubber, and perfluoroelastomers are commonly employed in super critical CO 2 (sCO2) energy conversion systems. O-rings and gaskets made from these polymers face stringent performance conditions such as elevated temperatures, high pressures, pollutants and corrosive humid environments. Critical knowledge gaps about polymer degradation from sCO2 exposure need to be addressed. To understand these effects, we have studied nine commonly used polymers subjected to elevated temperatures under isobaric conditions of sCO2 pressure. The polymers (PEEK, Nylon, PTFE, EPDM, Nitrile rubber, EPR, Neoprene, perfluoroelastomer FF 202 and Viton) were exposed for 1000 hours at 100°C to 25 MPa sCO2 pressure in an autoclave. In a second study, elastomers perfluoroelastomer (FF202) and EPDM were exposed to 25 MPa sCO2 for 1000 hours at 150°C. Samples were extracted for ex-situ characterization at t = 200 hours and then at the completion of the test at t=1000 hours. The polymer samples were examined for physical and chemical changes by Dynamic Mechanical and Thermal Analysis (DMTA), Fourier Transform Infrared (FTIR) spectroscopy, and compression set. Density and mass changes immediately after removal from test and 48 hours later, and optical microscopy techniques were also used. Microcomputer tomography (micro CI) data was generated on select specimens. Super-critical CO 2 effects have been identified as either physical or chemical effects. For each polymer, the dominance of one type of effect over the other was evaluated. Attempts were also made to qualitatively link sCO2 effects such as lowering or increase in glass transition temperatures, storage modulus changes, mass and compression set changes, chemical changes seen in FTIR analyses and blister and void formation seen post-exposure to polymer microstructure-related mechanisms such as plasticization of the polymer matrix, escape of volatiles from the polymer during depressurization, and filler and plasticizer effects on microstructure with rapid depressurization rates.

36 MATERIALS SCIENCE↗

New developments in thermally stable polymers

Advances in high-temperature polymers since 1985 are discussed with the emphasis on the chemistry. High-temperature polymers refer to materials that exhibit glass-transition temperatures greater than 200 C and have the chemical structure expected to provide high thermooxidative stability. Specific polymers or series of polymers were selected to show how the chemical structure influences certain properties. Poly(arylene ethers) and polyimides are the two principal families of polymers discussed. Recent work on poly(arylene ethers) has concentrated on incorporating heterocyclic units within the polymer backbone. Recent polyimide work has centered on the synthesis of new polymers from novel monomers, several containing the trifluoromethyl group strategically located on the molecule. Various members in each of these polymer families display a unique combination of properties, heretofore unattainable. Other families of polymers are also briefly discussed with a polymer from an AB maleimidobenzocyclobutene exhibiting an especially attractive combination of properties.

Hergenrother, Paul M.↗

Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications

In the low Earth orbit (LEO) space environment, spacecraft surfaces can be altered during atomic oxygen exposure through oxidation and erosion. There can be terrestrial benefits of such interactions, such as the modification of hydrophobic or hydrophilic properties of polymers due to chemical modification and texturing. Such modification of the surface may be useful for biomedical applications. For example, atomic oxygen texturing may increase the hydrophilicity of polymers, such as chlorotrifluoroethylene (Aclar), thus allowing increased adhesion and spreading of cells on textured Petri dishes. The purpose of this study was to determine the effect of atomic oxygen exposure on the hydrophilicity of nine different polymers. To determine whether hydrophilicity remains static after atomic oxygen exposure or changes with exposure, the contact angles between the polymer and a water droplet placed on the polymer s surface were measured. The polymers were exposed to atomic oxygen in a radio frequency (RF) plasma asher. Atomic oxygen plasma treatment was found to significantly alter the hydrophilicity of non-fluorinated polymers. Significant decreases in the water contact angle occurred with atomic oxygen exposure. Fluorinated polymers were found to be less sensitive to changes in hydrophilicity for equivalent atomic oxygen exposures, and two of the fluorinated polymers became more hydrophobic. The majority of change in water contact angle of the non-fluorinated polymers was found to occur with very low fluence exposures, indicating potential cell culturing benefit with short treatment time.

Beger, Lauren↗

Atomic Oxygen Erosion Yield Predictive Tool for Spacecraft Polymers in Low Earth Orbit

A predictive tool was developed to estimate the low Earth orbit (LEO) atomic oxygen erosion yield of polymers based on the results of the Polymer Erosion and Contamination Experiment (PEACE) Polymers experiment flown as part of the Materials International Space Station Experiment 2 (MISSE 2). The MISSE 2 PEACE experiment accurately measured the erosion yield of a wide variety of polymers and pyrolytic graphite. The 40 different materials tested were selected specifically to represent a variety of polymers used in space as well as a wide variety of polymer chemical structures. The resulting erosion yield data was used to develop a predictive tool which utilizes chemical structure and physical properties of polymers that can be measured in ground laboratory testing to predict the in-space atomic oxygen erosion yield of a polymer. The properties include chemical structure, bonding information, density and ash content. The resulting predictive tool has a correlation coefficient of 0.914 when compared with actual MISSE 2 space data for 38 polymers and pyrolytic graphite. The intent of the predictive tool is to be able to make estimates of atomic oxygen erosion yields for new polymers without requiring expensive and time consumptive in-space testing.

Bank, Bruce A.↗

Norbornene-Based Polymer Electrolytes for Lithium Cells

Norbornene-based polymers have shown promise as solid electrolytes for lithium-based rechargeable electrochemical cells. These polymers are characterized as single-ion conductors. Single-ion-conducting polymers that can be used in lithium cells have long been sought. Single-ion conductors are preferred to multiple-ion conductors as solid electrolytes because concentration gradients associated with multiple-ion conduction lead to concentration polarization. By minimizing concentration polarization, one can enhance charge and discharge rates. Norbornene sulfonic acid esters have been synthesized by a ring-opening metathesis polymerization technique, using ruthenium-based catalysts. The resulting polymer structures (see figure) include sulfonate ionomers attached to the backbones of the polymer molecules. These molecules are single-ion conductors in that they conduct mobile Li+ ions only; the SO3 anions in these polymers, being tethered to the backbones, do not contribute to ionic conduction. This molecular system is especially attractive in that it is highly amenable to modification through functionalization of the backbone or copolymerization with various monomers. Polymers of this type have been blended with poly(ethylene oxide) to lend mechanical integrity to free-standing films, and the films have been fabricated into solid polymer electrolytes. These electrolytes have been demonstrated to exhibit conductivity of 2 10(exp -5)S/cm (which is high, relative to the conductivities of other solid electrolytes) at ambient temperature, plus acceptably high stability. This type of norbornene-based polymeric solid electrolyte is in the early stages of development. Inasmuch as the method of synthesis of these polymers is inherently flexible and techniques for the fabrication of the polymers into solid electrolytes are amenable to optimization, there is reason to anticipate further improvements.

Cheung, Iris↗

A Preliminary Study on the Toxic Combustion Products Testing of Polymers Used in High-Pressure Oxygen Systems

One likely cause of polymer ignition in a high-pressure oxygen system is adiabatic-compression heating of polymers caused by pneumatic impact. Oxidative _ pyrolysis or combustion of polymers in a high-pressure oxygen system could generate toxic gases. This paper reports the preliminary results of toxic combustion product testing of selected polymers in a pneumatic-impact test system. Five polymers commonly used in high-pressure oxygen systems, Nylon 6/6, polychlorotrifluoroethylene (CTFE), polytetrafluoroethylene (PTFE), fluoroelastomer (Viton(TradeMark) A), and nitrile rubber (Buna N), were tested in a pneumatic-impact test system at 2500- or 3500-psia oxygen pressure. The polymers were ignited and burned, then combustion products were collected in a stainless-steel sample bottle and analyzed by GC/MS/IRD, GC/FID, and GC/Methanizer/FID. The results of adiabatic-compression tests show that combustion of hydrocarbon polymers, nitrogen-containing polymers, and halogenated polymers in high-pressure oxygen systems are relatively complete. Toxicity of the combustion product gas is presumably much lower than the combustion product gas generated from ambient-pressure oxygen (or air) environments. The NASA-Lewis equilibrium code was used to determine the composition of combustion product gas generated from a simulated, adiabatic-compression test of nine polymers. The results are presented and discussed.

Hshieh, Fu-Yu↗

High-Performance Polymers Having Low Melt Viscosities

High-performance polymers that have improved processing characteristics, and a method of making them, have been invented. One of the improved characteristics is low (relative to corresponding prior polymers) melt viscosities at given temperatures. This characteristic makes it possible to utilize such processes as resin-transfer molding and resin-film infusion and to perform autoclave processing at lower temperatures and/or pressures. Another improved characteristic is larger processing windows that is, longer times at low viscosities. Other improved characteristics include increased solubility of uncured polymer precursors that contain reactive groups, greater densities of cross-links in cured polymers, improved mechanical properties of the cured polymers, and greater resistance of the cured polymers to chemical attack. The invention is particularly applicable to poly(arylene ether)s [PAEs] and polyimides [PIs] that are useful as adhesives, matrices of composite materials, moldings, films, and coatings. PAEs and PIs synthesized according to the invention comprise mixtures of branched, linear, and star-shaped molecules. The monomers of these polymers can be capped with either reactive end groups to obtain thermosets or nonreactive end groups to obtain thermoplastics. The synthesis of a polymeric mixture according to the invention involves the use of a small amount of a trifunctional monomer. In the case of a PAE, the trifunctional monomer is a trihydroxy- containing compound for example, 1,3,5-trihydroxybenzene (THB). In the case of a PI, the trifunctional monomer is a triamine for example, triamino pyrimidine or melamine. In addition to the aforementioned trifunctional monomer, one uses the difunctional monomers of the conventional formulation of the polymer in question (see figure). In cases of nonreactive end caps, the polymeric mixtures of the invention have melt viscosities and melting temperatures lower than those of the corresponding linear polymers of equal molecular weights. The lower melting temperatures and melt viscosities provide larger processing windows. In cases of reactive end caps, the polymeric mixtures of the invention have lower melt viscosities before curing and the higher cross-link densities after curing (where branching in the uncured systems would become cross-links in the cured systems), relative to the corresponding linear polymers of equal molecular weights. The greater cross-link densities afford increased resistance to chemical attack and improved mechanical properties.

Jensen, Brian J.↗

Rehydration Data for the Materials International Space Station Experiment (MISSE) Polymer Films

Atomic oxygen erosion of polymers in low Earth orbit (LEO) poses a serious threat to spacecraft performance and durability. Forty thin film polymer and pyrolytic graphite samples, collectively called the PEACE (Polymer Erosion and Contamination Experiment) Polymers, were exposed to the LEO space environment on the exterior of the ISS for nearly four years as part of the Materials International Space Station Experiment 1 & 2 (MISSE 1 & 2) mission. The purpose of the MISSE 2 PEACE Polymers experiment was to determine the atomic oxygen (AO) erosion yield (E(sub y), volume loss per incident oxygen atom) of a wide variety of polymers exposed to the LEO space environment. The Ey values were determined based on mass loss measurements. Because many polymeric materials are hygroscopic, the pre-flight and post-flight mass measurements were obtained using dehydrated samples. To maximize the accuracy of the mass measurements, obtaining dehydration data for each of the polymers was desired to ensure that the samples were fully dehydrated before weighing. A comparison of dehydration and rehydration data showed that rehydration data mirrors dehydration data, and is easier and more reliable to obtain. Tests were also conducted to see if multiple samples could be dehydrated and weighed sequentially. Rehydration curves of 43 polymers and pyrolytic graphite were obtained. This information was used to determine the best pre-flight, and post-flight, mass measurement procedures for the MISSE 2 PEACE Polymers experiment, and for subsequent NASA Glenn Research Center MISSE polymer flight experiments.

de Groh, Kim K.↗

Shape memory polymers

New shape memory polymer compositions, methods for synthesizing new shape memory polymers, and apparatus comprising an actuator and a shape memory polymer wherein the shape memory polymer comprises at least a portion of the actuator. A shape memory polymer comprising a polymer composition which physically forms a network structure wherein the polymer composition has shape-memory behavior and can be formed into a permanent primary shape, re-formed into a stable secondary shape, and controllably actuated to recover the permanent primary shape. Polymers have optimal aliphatic network structures due to minimization of dangling chains by using monomers that are symmetrical and that have matching amine and hydroxyl groups providing polymers and polymer foams with clarity, tight (narrow temperature range) single transitions, and high shape recovery and recovery force that are especially useful for implanting in the human body.

36 MATERIALS SCIENCE↗

Shape memory polymers

New shape memory polymer compositions, methods for synthesizing new shape memory polymers, and apparatus comprising an actuator and a shape memory polymer wherein the shape memory polymer comprises at least a portion of the actuator. A shape memory polymer comprising a polymer composition which physically forms a network structure wherein the polymer composition has shape-memory behavior and can be formed into a permanent primary shape, re-formed into a stable secondary shape, and controllably actuated to recover the permanent primary shape. Polymers have optimal aliphatic network structures due to minimization of dangling chains by using monomers that are symmetrical and that have matching amine and hydroxl groups providing polymers and polymer foams with clarity, tight (narrow temperature range) single transitions, and high shape recovery and recovery force that are especially useful for implanting in the human body.

36 MATERIALS SCIENCE↗

NASICON-polymer electrolyte structure

A method is provided for forming a sodium-containing particle electrolyte structure. The method provides sodium-containing particles (e.g., NASICON), dispersed in a liquid phase polymer, to form a polymer film with sodium-containing particles distributed in the polymer film. The liquid phase polymer is a result of dissolving the polymer in a solvent or melting the polymer in an extrusion process. In one aspect, the method forms a plurality of polymer film layers, where each polymer film layer includes sodium-containing particles. For example, the plurality of polymer film layers may form a stack having a top layer and a bottom layer, where with percentage of sodium-containing particles in the polymer film layers increasing from the bottom layer to the top layer. In another aspect, the sodium-containing particles are coated with a dopant. A sodium-containing particle electrolyte structure and a battery made using the sodium-containing particle electrolyte structure are also presented.

Wang, Long↗

A Computational Fluid Dynamic Study on Polymer Heat Exchangers

Polymer heat exchangers have been developed for the applications involving weight restrictions or chemical compatibility and fouling issues owing to the low density, anticorrosive properties, and low thermal expansion of polymers. Recently development of additive manufacturing also brings new opportunities to make polymer heat exchangers with desired design that was hard to realize before. However, due to the lower thermal conductivity polymer composite, the overall heat transfer performance is still a challenge in the polymer heat exchanger technology. In present work, a computational fluid dynamic (CFD) model has been developed to study the overall heat transfer performance of additively manufactured polymer heat exchangers. The CFD results offer an insight of fluid flow and temperature distribution in the polymer heat exchangers. This study provides a guidance not only on the polymer material selection but also on the design of polymer heat exchangers. The conclusions will be helpful to design a polymer heat exchanger whose overall heat transfer performance is comparable to a metal heat exchanger.

Zhang, Mingkan↗

Shape memory polymers

New shape memory polymer compositions, methods for synthesizing new shape memory polymers, and apparatus comprising an actuator and a shape memory polymer wherein the shape memory polymer comprises at least a portion of the actuator. A shape memory polymer comprising a polymer composition which physically forms a network structure wherein the polymer composition has shape-memory behavior and can be formed into a permanent primary shape, re-formed into a stable secondary shape, and controllably actuated to recover the permanent primary shape. Polymers have optimal aliphatic network structures due to minimization of dangling chains by using monomers that are symmetrical and that have matching amine and hydroxl groups providing polymers and polymer foams with clarity, tight (narrow temperature range) single transitions, and high shape recovery and recovery force that are especially useful for implanting in the human body.

59 BASIC BIOLOGICAL SCIENCES↗

Shape memory polymers

New shape memory polymer compositions, methods for synthesizing new shape memory polymers, and apparatus comprising an actuator and a shape memory polymer wherein the shape memory polymer comprises at least a portion of the actuator. A shape memory polymer comprising a polymer composition which physically forms a network structure wherein the polymer composition has shape-memory behavior and can be formed into a permanent primary shape, re-formed into a stable secondary shape, and controllably actuated to recover the permanent primary shape. Polymers have optimal aliphatic network structures due to minimization of dangling chains by using monomers that are symmetrical and that have matching amine and hydroxl groups providing polymers and polymer foams with clarity, tight (narrow temperature range) single transitions, and high shape recovery and recovery force that are especially useful for implanting in the human body.

Wilson, Thomas S.↗

High optical transparency polymer aerogels using low refractive index monomers

A method of producing a polymer aerogel includes dissolving precursors into a solvent, wherein the precursors include monomers, crosslinkers, a controlling agent and an initiator to form a precursor solution, wherein at least one of the monomers or at least one of the crosslinkers has a refractive index of 1.5 or lower, polymerizing the precursor solution to form a gel polymer, and removing the solvent from the gel polymer to produce the polymer aerogel. A method of producing a polymer aerogel include dissolving precursors into a solvent, wherein the precursors include monomers, crosslinkers, a controlling agent and an initiator to form a precursor solution, polymerizing the precursor solution to form a gel polymer, removing the solvent from the gel polymer to produce the polymer aerogel, and reducing a refractive index of one of either the gel polymer or the polymer aerogel.

Bulger, Eli↗

Development of Polymer Waste Form for Spent Ion-Exchange Resins

A large amount of radioactive waste streams has been treated by ion-exchange resins at most of nuclear facilities for many years. These activities leave radionuclides as well as chemical contaminants on the spent resins, and the spent resins are considered as low- and intermediate-level radioactive waste. Spent ion-exchange resins require special immobilization treatment to meet the waste acceptance criteria for disposal. Immobilization of spent ion-exchange resins can be processed by mixing or incorporating them with suitable solidifying materials, such as cement, bitumen, organic polymers, and other materials or a combination of them. The selection of immobilization options for spent ion-exchange resins must consider their physical, chemical, and radiological characteristics. In this study, direct immobilization method was used to solidify the spent ion-exchange resins using organic polymer for improving the waste content. The objective of this study is to test the immobilization of spent ion-exchange resins using polymer waste form and enhance the solidified waste content. The specific objective of this study was to develop polymer waste form to solidify spent ion-exchange resins. Leaching (ANSI/ANS 16.1) and compressive strength tests were performed to meet the acceptance criteria of waste form for disposal. Ion-exchange resin has been solidified physically and chemically stable in the polymer waste form. The leaching test (ANSI/ANS16.1) for two polymer waste form specimens were conducted. The leachability indexes of sample A and B showed to meet the acceptance criteria for disposal. The compressive strength tested showed higher values in polymer waste form prepared with ion exchange resin compared to CoCl{sub 2} polymer form (sample B). Although spent resin was successively solidified in polymer matrix, the future experiment will develop a polymer waste form as a pre-treatment of spent resin for size reduction using a ball milling (500 RPM, 280 min)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Polymer grafted aramid nanofiber reinforces immiscible waste polypropylene/poly(ethylene terephthalate)

Polypropylene (PP) and poly(ethylene terephthalate) (PET) are plastics commonly used for packaging because of their excellent barrier and mechanical properties. The properties of these plastics are often diminished after mechanical recycling, inevitably causing down-cycling. Furthermore, this problem is exacerbated when different kinds of polymers mix. Aramid nanofibers have the potential to improve the mechanical properties of polymers due to their excellent mechanical properties but their poor dispersion in polymers is a challenge. Grafting polymers onto nanofibers can help address this challenge. In this work, different loading levels (1%, 2%, and 5%) of polymer grafted aramid nanofibers (ANFs) are blended with waste PP/PET (90/10), simulating a PP waste stream containing traces of PET contaminants. Scanning electronic microscopy, rheology, and differential scanning calorimetry results show the affinity of PP functionalized aramid nanofibers (PP_ANF) towards the PP matrix. At 1 wt% of the nanofiber, the size of the PET droplets in the PP matrix of the PP_ANF blend range from 0.2 to 2.0 μm while that of unmodified ANF and PET_ANF blends are in the range of 0.1–6.2 and 0.5–7.4 μm, respectively. In summary, polymer grafted ANFs have the tendency of improving properties of its like polymers due to similarity in the grafting polymer and the polymer matrix.

36 MATERIALS SCIENCE↗