Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Passive Thermal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Working Fluid Trade Study for a Two-Phase Mechanically Pumped Loop Thermal Control System

NASA Jet Propulsion Laboratory is investigating a two-phase mechanically pumped fluid loop (MPFL) technology for spacecraft thermal control for future planetary space science mission concepts. The two-phase technology combines the potential of single-phase MPFL and the passive two-phase heat pipe systems. Previous two-phase MPFL studies4,5 at JPL have identified an evaporator system with a separated flow architecture as providing a robust light mass thermal control system with very high spatial and temporal thermal stability required by the science instruments on these missions. These studies have further identified the thermophysical properties of the working fluid to be key to the performance of a two-phase fluid loop. This paper describes the methodology used in the selection of the working fluids for optimizing the performance of the two-phase MPFL. A high level model was developed that includes the constraints and boundaries driven by the system components. The performance of fluids from the REFPROP database were investigated and rated for this system. The working fluid attributes such as cost, hazardous properties, and heritage were taken into account in this selection. A typical spacecraft dissipating 1000 W and a fluid loop consisting of an evaporator, accumulator, radiator, and associated tubing components was used as an example in this study.

Daimaru, Takuro↗

Assessment of Sodium Thermal Stratification Models Utilizing the TSTF Benchmark

As a result of certain transient scenarios, a thermally stratified layer of liquid sodium can develop in the bulk coolant volumes of a sodium-cooled fast reactor (SFR). In addition to the effects a stratification layer has on the temperature of the heat transport system, a stratification layer can also influence the transition to and establishment of natural circulation flow, which plays an important role in passive cooling and the inherent safety of a pool-type SFR. Therefore, the ability to accurately capture thermal stratification phenomena is important when demonstrating the safety basis of a pool-type SFR during transient sequences. The present work assesses various computational models with different fidelities in their ability to predict thermal stratification in the upper plenum of an SFR. Each computational model will be assessed using the data generated at the Thermal Stratification Test Facility (TSTF) located at the University of Wisconsin-Madison. Using measured flow rate and inlet temperature data, the measured temperature distributions of the tests are compared to the predictions of the lumped volume-based models in SAS4A/SASSYS-1, a 1D-based model in SAM, and a 3-D computational fluid dynamics (CFD) model using STAR-CCM+. The relative performance of the various computational methods is assessed with respect to key metrics such as bulk coolant temperature distribution and plenum exit temperature. A total of eight tests are analyzed, covering different combinations of flow rates (3 and 10 GPM) and upper internal structure (UIS) configurations (none, solid, porous, and open) The perfect mixing model of SAS4A/SASSYS-1 provides the highest accuracy when the flow rate is high and there is no UIS in the test vessel, as high flow rate injection promotes thermal mixing of the sodium in the test vessel. For most of the analyzed tests, the stratified volume model of SAS4A/SASSYS-1 is able to predict the delay in the outlet temperature drop and temperature distribution in the test vessel by a small number of layers to represent thermal stratification. However, the stratified volume model can only simulate a maximum of three temperature layers within a volume and when a layer approaches the elevation of the outlet, the predicted outlet temperature can demonstrate rapid, non-physical changes. The 1-D axial mixing model of SAM provides results that agree reasonably well with the measured data in the prediction of the temporal evolution of the outlet temperature with the exception of the case with a high flow rate and no UIS. The SAM 1-D model has a similar level of accuracy to CFD results when it comes to predicting the outlet temperature. CFD shows overall good agreement in predicting the temperature distribution in the test vessel and outlet temperature. As CFD can model the test vessel geometry in detail, it performs well in the cases of complex geometries such as tests that included a UIS and internal flow through the UIS resulting in active mixing of the coolant in the test vessel. Each of the models discussed in the present work has the potential to be useful during the various stages of reactor design, analysis, and licensing. The lumped-volume approach can be applied for fast turnaround safety calculations to obtain overall reactor behavior during transients. The 1-D models provide improved accuracy when stratification is expected for a relatively low increase in the computational cost. The CFD model can be utilized for confirmatory analysis of the 1-D model, when experimental measurements are not available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Overview of Materials International Space Station Experiment 7B

Materials International Space Station Experiment 7B (MISSE 7B) is the most recent in a series of experiments flown on the exterior of International Space Station for the purpose of determining the durability of materials and components in the space environment. A collaborative effort among the Department of Defense, the National Aeronautics and Space Administration, industry, and academia, MISSE 7B will be flying a number of NASA experiments designed to gain knowledge in the area of space environmental effects to mitigate risk for exploration missions. Consisting of trays called Passive Experiment Containers, the suitcase sized payload opens on hinges and allows active and passive experiments contained within to be exposed to the ram and wake or zenith and nadir directions in low Earth orbit, in essence, providing a test bed for atomic oxygen exposure, ultraviolet radiation exposure, charged particle radiation exposure, and thermal cycling. New for MISSE 7B is the ability to monitor experiments actively, with data sent back to Earth via International Space Station communications. NASA?s active and passive experiments cover a range of interest for the Agency. Materials relevant to the Constellation Program include: solar array materials, seal materials, and thermal protection system materials. Materials relevant to the Exploration Technology Development Program include: fabrics for spacesuits, materials for lunar dust mitigation, and new thermal control coatings. Sensors and components on MISSE 7B include: atomic oxygen fluence monitors, ultraviolet radiation sensors, and electro-optical components. In addition, fundamental space environmental durability science experiments are being flown to gather atomic oxygen erosion data and thin film polymer mechanical and optical property data relevant to lunar lander insulation and the James Web Space Telescope. This paper will present an overview of the NASA experiments to be flown on MISSE 7B, along with a summary of the thermal environment to be expected during the 1 yr mission scheduled for launch in 2009.

Jaworske, Donald A.↗

Ring Model Development and Validation for Prismatic HTGR Core Thermal-hydraulics and Safety Analysis

Because of the complex core geometry, prismatic high temperature gas-cooled reactors (prismatic HTGRs) often exhibit complex thermal fluid behaviors during both normal operating and transient conditions. Most HTGR designs rely on passive safety system for decay heat removal, such as the reactor cavity cooling system (RCCS). During postulated accidents like Pressurized Conduction Cooldown (PCC) event, the decay heat is first radially transferred from the core region to the reactor vessel outer surface, then to the RCCS cooling panels. The peak fuel temperature is controlled by heat transfer mechanisms with two distinctive characteristic length scales, i.e., the core-wise effective heat conduction and local heat conduction in the fuel pellet scale. As both length scales are essential to determine the fuel temperature, from the modeling perspective, computer codes must be able to capture heat transfer in both scales. This is challenging for both computational fluid dynamics (CFD) tools because of extremely large amount of computation resources required, and for system analysis codes because of the challenge to model the complex core geometry. Under the support of DOE-NE’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, efforts have been pursued to support HTGR technology development and its modeling and simulation needs. There is a particular need for advanced modeling and simulation tools to predict thermal-fluid behavior during safety-related transients. In our previous studies, the ring model was adopted in SAM and further developed to simulate the normal operating condition and a PCC event using the MHTGR-350 design of General Atomics as the reference design. This current work represents a continuation of these previous efforts, and the focus is to critically review and examine simplifications and assumptions made to develop the ring model, and to perform code validation using experimental data from an integral-effect test facility, the High Temperature Test Facility (HTTF) at the Oregon State University. In this study, the test PG-27 from the HTTF test suite was selected for code validation purpose. The test PG-27 is a transient test designed to simulate the PCC event of the MHTGR design. Very good agreements between SAM prediction and experimental measurements were found in both coolant and solid structure temperatures during the transient.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

Cooling performance of an active-passive hybrid composite phase change material (HcPCM) finned heat sink: Constant operating mode

Here, the present study explores a hybrid thermal management technology based on air cooling and hybrid composite phase change material (HcPCM) filled finned heat sink for cooling performance of lower to medium heat flux dissipating electronic devices. Two-dimensional numerical simulations are conducted to study the conjugate heat transfer effects of three types of finned heat sink: air-cooled finned heat sink, HcPCM-cooled finned heat sink, and hybrid (air-HcPCM) cooled finned heat sink. A heat sink with a constant volume faction of plate-fins is designed in all cases and simultaneous effects of hybrid nanoparticles and air are investigated to keep the heat sink temperature at safe operating conditions between 40–60°C. The effect of air is incorporated into the heat sink by applying the convective heat transfer coefficient of h c = 10–100W /m 2 .K which tends to create the natural convection and forced convection heat transfer characteristics. The heat flux is varied from 25–40kW /m 2 in the current study. The hybrid nanoparticles of carbon additives (GO and MWCNTs) are dispersed into the RT-35HC, used as a PCM, with a volume fraction of 0% to 6%. Transient simulations are carried out using COMSOL Multiphysics to solve the governing equations for PCM based conjugate heat transfer model. The results showed that forced convection heat transfer improved the cooling performance of the hybrid heat sink compared to natural convection heat transfer. The addition of nanoparticles further enhanced thermal enhancement and uniform melting distribution of PCM inside the finned heat sink. The h c between 30 to 50W/m 2 .K shows optimized values for forced convection heat transfer operating conditions. The volume fraction of 2% of GO+MWCNTs nanoparticles in recommended or optimum concentration for uniform melting of PCM inside the finned heat sink.

36 MATERIALS SCIENCE↗

A Structural Design Approach Tailored for the Rapid Preliminary Design of Microreactor Components

High-temperature microreactors can play a role in developing reliable, portable energy sources for off-grid remote locations, microgrid concepts, and industrial process heat. Portability and passive safety criteria tend to skew microreactor structural component designs toward complex geometries, high thermal stresses, and design bases with large numbers of startup/shutdown cycles. Current design rules, as typified by Section III of the American Society of Mechanical Engineers (ASME) Boiler & Pressure Vessel Code, are less than optimal for these conditions, particularly for preliminary component designs where developers need to rapidly consider a large number of potential component configurations. This paper presents a design method targeted toward rapid, efficient evaluation of preliminary component designs using modern finite element analysis. The new method retains key connections with the ASME Code rules and design data while streamlining the design approach. This paper presents the design method, several verification examples illustrating the similarities and differences between the new method and the current ASME rules, and the application of the new approach to the evaluation of a test article mimicking key features of a heat pipe–cooled microreactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MIZEX-WEST NASA CV-990 flight report

As part of the Bering Sea marginal ice zone winter experiment (MIZEX-WEST), the CV-990 airborne laboratory was flown to assess the potential of using an extended range of wavelengths for improving passive microwave sea ice observations from spacecraft and second to provide an overview of the MIZ for large-scale processes studies. The aircraft was equipped with both imaging and fixed-beam, dual-polarized passive microwave radiometers ranging from 1.5 millimeter to 3 centimeter wavelengths. Visual, photographic, and thermal (10.7 micron) infrared surface observations were also made from the aircraft to complement the microwave measurements. The flight operations and in-flight observations are discussed and each flight is summarized including flight objective and instrument status. Preliminary mosaic images obtained with the ESMR imager, Nimbus-7 orbits over the Bering Sea, ice observations obtained by an ice observer on board, and composite maps of the general ice conditions for the month of February are also presented.

Cavalieri, D. J.↗

Dust-dynamic feedbacks in the Martian atmosphere: Surface dust lifting

Numerical models have been developed to study surface dust lifting in the Martian atmosphere. The present model is comprised of interactively coupled 3-D dynamical and aerosol transport/microphysical models. The nature of possible feedbacks between surface dust lifting and the amplification/damping of near-surface wind and thermal fields and their implications for additional lifting is investigated. These studies have examined large scale Martian topography for its impact upon the ability of the atmospheric circulation to lift dust from the surface, and the particular component(s) responsible for the lifting (e.g. overturning circulation, thermal tides, baroclinic waves). Analogous experiments in which the lifted dust is radiatively inactive (passive tracer) have been conducted to act as a control against which feedbacks are defined.

Murphy, James R.↗

Thermal control materials on EOIM-3

Thermal control paints, anodized aluminum, and beta cloth samples were flown on STS-46 as part of the Evaluation of Oxygen Interaction with Materials Experiment (EOIM-3). The thermal control paints flown on EOIM-3 include ceramic and polyurethane-based paints. Passively exposed samples are compared to actively heated samples and controlled exposure samples. Optical property measurements of absorptivity, emissivity, and spectrofluorescence are presented for each paint. Several variations of anodized aluminum, including chromic acid anodize, sulfuric acid anodize, and boric/sulfuric acid anodize were flown on the actively heated trays and the passive exposure trays. The post-flight optical properties are within tolerances for these materials. Also flown were two samples of yellow anodized aluminum. The yellow anodized aluminum samples darkened noticeably. Samples of aluminized and unaluminized beta cloth, a fiberglass woven mat impregnated with TFE Teflon, were flown with passive exposure to the space environment. Data from this part of the experiment is correlated to observations from LDEF and erosion of the Teflon thin film samples also flown on EOIM-3 and LDEF.

Finckenor, Miria M.↗

Interannual Variations of Shallow Firn Temperature at Greenland Summit

Firn-temperature profiles are calculated in a thermal model using continuous surface temperatures derived from Automatic Weather Station (AWS) data and passive microwave data in the Greenland Summit region during the period 1987-1999. The results show that significant interannual variations of mean summer (June to August) and annual temperatures occur in the top 15 m, in addition to the normal seasonal cycle of firn temperature. At 5 m depth, the seasonal cycle is damped to 13% of the surface seasonal amplitude, but even at 15 m about 1% or 0.6 C of the seasonal cycle persists. Both summer and mean annual temperatures decrease from 1987 to 1992, followed by a general increasing trend. Interannual variability is 5 C at the surface, but only is only dampened to 3.2 C at 10 m depth and 0.7 C at 15 m depth. Dampening of the interannual variability with depth is slower than dampening of the seasonal cycle, because of the longer time constant of the interannual variation. The warmer spring and summer temperatures experienced in the top 5 m, due to both the seasonal cycle and interannual variations, affect the rate of firn densification, which is non-linearly dependent on temperature. During the 12 year period 1987-1999, the mean annual surface temperature is -29.2 C, and the mean annual 15 m temperature is -30. 1 C, which is more than 1 C warmer than a 15-m borehole temperature representing the period of about 1959 and warmer than the best-fit temperature history by Alley and Koci back to 1500 A.D..

Jun, Li↗

Thrust Stand for Vertically Oriented Electric Propulsion Performance Evaluation

A variation of a hanging pendulum thrust stand capable of measuring the performance of an electric thruster operating in the vertical orientation is presented. The vertical orientation of the thruster dictates that the thruster must be horizontally offset from the pendulum pivot arm, necessitating the use of a counterweight system to provide a neutrally-stable system. Motion of the pendulum arm is transferred through a balance mechanism to a secondary arm on which deflection is measured. A non-contact light-based transducer is used to measure displacement of the secondary beam. The members experience very little friction, rotating on twisting torsional pivots with oscillatory motion attenuated by a passive, eddy current damper. Displacement is calibrated using an in situ thrust calibration system. Thermal management and self-leveling systems are incorporated to mitigate thermal and mechanical drifts. Gravitational restoring force and torsional spring constants associated with flexure pivots provide restoring moments. An analysis of the design indicates that the thrust measurement range spans roughly four decades, with the stand capable of measuring thrust up to 12 N for a 200 kg thruster and up to approximately 800 mN for a 10 kg thruster. Data obtained from calibration tests performed using a 26.8 lbm simulated thruster indicated a resolution of 1 mN on 100 mN-level thrusts, while those tests conducted on 200 lbm thruster yielded a resolution of roughly 2.5 micro at thrust levels of 0.5 N and greater.

Moeller, Trevor↗

Zero Boil-Off System Testing

Cryogenic propellants such as liquid hydrogen (LH2) and liquid oxygen (LO2) are a part of NASA's future space exploration due to their high specific impulse for rocket motors of upper stages suitable for transporting 10s to 100s of metric tons of payload mass to destinations outside of low earth orbit and for their return. However, the low storage temperatures of LH2 and LO2 cause substantial boil-off losses for missions with durations greater than several months. These losses can be eliminated by incorporating high performance cryocooler technology to intercept heat load to the propellant tanks and modulating the cryocooler to control tank pressure. The active thermal control technology being developed by NASA is the reverse turbo-Brayton cycle cryocooler and its integration to the propellant tank through a distributed cooling tubing network coupled to the tank wall. This configuration was recently tested at NASA Glenn Research Center, in a vacuum chamber and cryoshroud that simulated the essential thermal aspects of low Earth orbit, its vacuum and temperature. Testing consisted of three passive tests with the active cryocooler system off, and 7 active tests, with the cryocooler powered up. The test matrix included zero boil-off tests performed at 90 full and 25 full, and several demonstrations at excess cooling capacity and reduced cooling capacity. From this, the tank pressure response with varied cryocooler power inputs was determined. This test series established that the active cooling system integrated with the propellant tank eliminated boil-off and robustly controlled tank pressure.

Plachta, David W.↗

Liquid Nitrogen Zero Boiloff Testing

Cryogenic propellants such as liquid hydrogen (LH2) and liquid oxygen (LO2) are a part of NASAs future space exploration due to their high specific impulse for rocket motors of upper stages suitable for transporting 10s to 100s of metric tons of payload mass to destinations outside of low earth orbit and for their return. However, the low storage temperatures of LH2 and LO2 cause substantial boil-off losses for missions with durations greater than several months. These losses can be eliminated by incorporating high performance cryocooler technology to intercept heat load to the propellant tanks and modulating the cryocooler to control tank pressure. The active thermal control technology being developed by NASA is the reverse turbo-Brayton cycle cryocooler and its integration to the propellant tank through a distributed cooling tubing network coupled to the tank wall. This configuration was recently tested at NASA Glenn Research Center, in a vacuum chamber and cryo-shroud that simulated the essential thermal aspects of low Earth orbit, its vacuum and temperature. Testing consisted of three passive tests with the active cryo-cooler system off, and 7 active tests, with the cryocooler powered up. The test matrix included zero boil-off tests performed at 90 full and 25 full, and several demonstrations at excess cooling capacity and reduced cooling capacity. From this, the tank pressure response with varied cryocooler power inputs was determined. This test series established that the active cooling system integrated with the propellant tank eliminated boil-off and robustly controlled tank pressure.

Cryogenic fluid management↗

The Peregrine Ion Trap Mass Spectrometer (PITMS) Investigation Development and Pre-Flight Planning

The Peregrine Ion Trap Mass Spectrometer (PITMS) is a mass spectrometer instrument that operated during the Astrobotic Peregrine Mission-1 as part of the NASA Commercial Lunar Payload Services (CLPS) initiative. This paper describes the instrument and investigation design, development, and planning conducted by the PITMS team consisting of a successful partnership between NASA Goddard Space Flight Center (GSFC), The Open University (OU), NASA, and ESA. PITMS was designed to measure the abundance and temporal variability of volatile species in the near-surface lunar exosphere from a landed platform on the lunar surface. The PITMS instrument consisted of an ESA-provided Exospheric Mass Spectrometer (EMS; including sensor, electronics, controller, power supply boards) and a GSFC wrapper that provided structural elements, thermal control, and a deployable dust cover. PITMS was designed to operate as a passive sampler, where ambient gases would enter PITMS through an aperture, diffuse around the mass analyzer cavity, become ionized by electron impact and trapped in a radiofrequency field, then sequentially released to a detector to build a mass spectrum. PITMS was capable of measuring species with a massto-charge ratio (m/z) from 10 to 150 Da, with a mass resolution of approximately 0.5 amu. The PITMS science investigation was planned to be operated by GSFC with an international team of scientists. Though the mission did not achieve its lunar landing, information about the PITMS instrument and planning is provided to be able to understand and effectively use data that will be forthcoming from the investigation.

Barbara Cohen↗

Introduction - Processes of continental rifting

It is thought likely that thermal thinning and/or diapirism can cause the extensional stress required for rifting. The rifting, however, will not occur unless the regional tectonic regime permits the sides of the rift to diverge. Whereas passive plate extension could cause rifting in isolation, the extension and rifting are likely to be localized where the lithosphere is weakest over an existing thermal anomaly. In those cases where asthenospheric diapirism occurs, which is essentially a response to thinning of the lithosphere by thermal thinning or plate extension, the effects of diapirism may completely mask the initiating mechanism. It is believed that anomalous heat transfer into the lithosphere, diapirism, and magmatism must all figure in rifting, along with a deviatoric stress field that will permit extension in a developing rift. Even though the models are useful in permitting idealized processes to be quantified and tested, better knowledge of lithosphere properties is considered necessary, in particular knowledge of mantle viscosity and its temperature dependence.

Morgan, P.↗

Analysis of Conduction Cooling Strategies for Wire Arc Additive Manufacturing

Metal additive manufacturing (AM) processing consists of numerous parameters which take time to optimize for various geometries. One aspect of the metal AM process that continues to be explored is the control of thermal energy accumulation during component manufacturing due to the melting and solidification of the feedstock. Excessive energy accumulation causes thermal failure of the component while minimal energy accumulation causes lack of fusion with the build plate or previous layer. The ability to simulate the thermal response of an AM component can increase research efficiency by reducing the time to optimize thermal energy accumulation. This paper presents an effective implementation of finite element analysis to determine the thermal response of a wire arc additive manufactured component with various build plate sizes and cooling methods including, integral build plate cooling, oversized build plates with passive cooling, and non-integral build plate cooling. The use of integral build plate cooling channels was shown to decrease the interpass temperature at the conclusion of the build process by 55% and build plate temperature by 96% compared to the conventionally deposited sample with 20 second dwell time. The use of a tall build plate with passive cooling was shown to reduce the interpass temperature by 32% as compared to the conventionally deposited sample with 20 second dwell time. Each cooling strategy evaluated decreased the interpass temperature within a range of 20–55% which enables higher deposition rates and decreased dwell times during depositions. The cooling strategies are designed to be implemented in a hybrid or retrofit AM platform to mitigate concerns of the thermal input from the additive process having detrimental effects on the precision of the machining process. This paper shows that accurate simulations of all strategies can be used to accurately predict the thermal response of the various strategies discussed. These cooling strategies will allow for increased deposition rates with comparable interpass temperature and decreased dwell time, increasing deposition efficiency. This model and these simulations are verified by experimental results. It is concluded that passive strategies, such as the over-sized tall build plate, can be used when liquid coolant in the AM environment could negatively affect the deposition process. Active cooling strategies, such as the integral build plate cooling could be used if low thermal conductivity materials are deposited or higher material deposition rates are desired. This paper discusses the use of active and passive cooling used during AM and shows how a simulation model can be used to make design choices for cooling strategies. The model also enables verification of select critical process parameters such as dwell times for a desired interpass temperature.

Heinrich, Lauren↗

Design and analysis of a cryogenic variable conductance axial grooved heat pipe

An investigation to adapt axial grooved designs to the gammit of heat pipe thermal control techniques, with particular emphasis on those suited for cryogenic applications was conducted. In addition to considering both active and passive gas control, diode designs utilizing liquid or gas blockage, or a liquid trap, are evaluated. The use of the liquid trap as a secondary heat pipe for forward mode operation during diode shutdown is also studied. This latter function is basically that of a thermal switch. Finally, a system capable of hybrid functions consisting of gas-controlled variable conductance and liquid trap diode shutdown or thermal switching is defined.

Source record↗