Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Asteroids seen by JWST-MIRI: Radiometric size, distance, and orbit constraints

Infrared measurements of asteroids are crucial for the determination of physical and thermal properties of individual objects, and for understanding the small-body populations in the solar system as a whole. However, standard radiometric methods can only be applied if the orbit of an object is known, hence its position at the time of the observation. With JWST-MIRI observations the situation will change and many unknown, often very small, solar system objects will be detected. Later orbit determinations are difficult due to the faintness of the objects and the lack of dedicated follow-up concepts. We present MIRI observations of the outer-belt asteroid (10920) 1998 BC1 and an unknown object, detected in all nine MIRI bands in close apparent proximity to (10920). We developed a new method called STM-ORBIT to interpret the multi-band measurements without knowing the object’s true location. The power of the new technique is that it determines the most-likely heliocentric and observer-centric distance and phase angle ranges, allowing us to make a radiometric size estimate. The application to the MIRI fluxes of (10920) was used to validate the method. It leads to a confirmation of the known radiometric size-albedo solution, and puts constraints on the asteroid’s location and orbit in agreement with its true orbit. To back up the validation of the method, we obtained additional ground-based light curve observations of (10920), combined with Gaia data, which indicate a very elongated object (a/b ≥ 1.5), with a spin-pole at (λ, β) ecl = (178°, +81°), with an estimated error of about 20°, and a rotation period of 4.861191 ± 0.000015 h. A thermophysical study of all available JWST-MIRI and WISE measurements leads to a size of 14.5–16.5 km (diameter of an equal-volume sphere), a geometric albedo pV between 0.05 and 0.10, and a thermal inertia in the range 9–35 (best value 15) J m -2 s -0.5 K -1 . For the newly discovered MIRI object, the STM-ORBIT method revealed a size of 100–230 m. The new asteroid must be on a low-inclination orbit (0.7° < i < 2.0°) and it was located in the inner main-belt region during JWST observations. A beaming parameter η larger than 1.0 would push the size even below 100 meters, a main-belt regime that has escaped IR detections so far. This kind of MIRI observations can therefore contribute to formation and evolution studies via classical size-frequency studies, which are currently limited to objects larger than about one kilometer in size. We estimate that MIRI frames with pointings close to the ecliptic and short integration times of only a few seconds will always include a few asteroids; most of them will be unknown objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of Aerosol and Cloud on the Solar Energy Potential over the Central Gangetic Himalayan Region

We examine the impact of atmospheric aerosols and clouds on the surface solar radiation and solar energy at Nainital, a high-altitude remote location in the central Gangetic Himalayan region (CGHR). For this purpose, we exploited the synergy of remote-sensed data in terms of ground-based AERONET Sun Photometer and satellite observations from the MODerate Resolution Imaging Spectroradiometer (MODIS) and the Meteosat Second Generation (MSG), with radiative transfer model (RTM) simulations and 1 day forecasts from the Copernicus Atmosphere Monitoring Service (CAMS). Clouds and aerosols are one of the most common sources of solar irradiance attenuation and hence causing performance issues in the photovoltaic (PV) and concentrated solar power (CSP) plant installations. The outputs of RTM results presented with high accuracy under clear, cloudy sky and dust conditions for global horizontal (GHI) and beam horizontal irradiance (BHI). On an annual basis the total aerosol attenuation was found to be up to 105 kWh m –2 for the GHI and 266 kWh m –2 for BHI, respectively, while the cloud effect is much stronger with an attenuation of 245 and 271 kWh m –2 on GHI and BHI. The results of this study will support the Indian solar energy producers and electricity handling entities in order to quantify the energy and financial losses due to cloud and aerosol presence.

54 ENVIRONMENTAL SCIENCES↗

Module-OT: A Turnkey Solution for Securing Energy Systems

The Modular Security Apparatus for Managing Distributed Cryptography for Command-and-Control Messages on Operational Technology Networks (Module-OT) is a flexible and lightweight solution for grid-edge devices focusing on end-to-end security. It is a bump- in- the-wire solution acting as a secure conduit for data between devices or systems across a network. It improves the cybersecurity posture of DER systems by providing authentication, authorization, and data integrity to secure DER communications. Additionally, it performs key management, provides data security through whitelisting Internet Protocol addresses and ports, blocks unauthorized connections, controls user access, and allows serial or Ethernet connections for added flexibility. The core software is portable to various Linux-based operating systems and is developed to be customized by the developer and researcher communities. Module-OT has been validated in the lab, has been demonstrated at a 500-KW PV-plus-storage site, and has been proven ready to secure operational technology devices. Its core functionality meets current standards, including validation procedures of the NIST Cryptographic Algorithm Validation Program (CAVP) and the Federal Information Processing Standard (FIPS 140-2). Because of its capability to provide an accessible and affordable option for stepping up security across modern energy systems, Module-OT can serve as an effective technological option to standardize cybersecurity moving forward.

cryptography↗

Thermal model to quantify the impact of sub-bandgap reflectance on operating temperature of fielded PV modules

Minimizing module heating is an effective way to increase the lifetime energy output of photovoltaic systems. Maximizing the reflection of light that is unusable for energy conversion is one of the most promising ways to reduce the operating temperature of fielded modules. We derive a model based on a steady-state energy balance to quantify the temperature benefit of cell or module optical modifications aimed at improving reflection of light with photon energies below the photovoltaic cell bandgap energy. This more detailed model is then simplified so that, from outdoor measured data, temperature differences arising from reflectance can be isolated from those arising from irradiance, wind speed, and module standard-test-condition efficiency.

14 SOLAR ENERGY↗

Value Proposition of UV-Absorbers in PV Module Encapsulation

Various common crystalline silicon cell technologies were exposed to UVA radiation (1.24 Wm-2 nm-1 at 340 nm peak) on the front and back faces at 45 degrees Celsius for periods up to 3000 h, representing about 3 y of solar exposure in Phoenix, Arizona, USA. The resulting degradation of the open-circuit voltage and short-circuit current is presented. Of the various cell types examined, significant levels of degradation were seen in all cases. Less degradation was generally found after UV irradiation of cell fronts and older cell types, whereas a bifacial PERC type exposed on the rear showed about 25% degradation in short circuit current, attributable to lack of a diffused surface field. Selected cells were exposed to UV irradiation with the addition of long pass UV filters to replicate UV-absorbers in encapsulants. Modern cell designs are sensitive to UV-ID because of reduced or eliminated front and back surface field and increased dependence on high quality surface passivation. Single transformation of the independent variable (t, kW h/m^2) could be used to achieve a linear model of the data to extrapolate to 50 y. Solar Advisor Model (SAM) shows appropriate filtering of UV-irradiation can improve LCOE and net present value of plant. Some advanced cell types are seen to be UV-resistant (cell level solutions also exist). Solutions therefore exist on the cell, glass, and encapsulant level. Changes over time in each of these would also need to be considered (solarization, encapsulant browning...).

ENGINEERING,SOLAR ENERGY↗

A parametric finite element study for determining burst strength of thin and thick-walled pressure vessels

To accurately predict the burst strength of both thin and thick-walled pressure vessels (PVs), a parametric study of PV burst strength was performed for a wide range of vessel geometries and materials using elastic-plastic finite element analysis (FEA). A valid FEA model was established through a detailed study of 2D versus 3D FEA models, the critical stress failure criterion versus the limit load criteria, and the thick-wall effect on the FEA simulations. Here, the results show that the stresses and strains at the mean diameter, rather than outside diameter, determines a more accurate burst strength for both thin and thick-walled PVs. On this basis, a parametrized FEA script using the ABAQUS Python application programming interface (API) was used to create a large database of PV burst strengths for a variety of vessel geometries and materials, demonstrating that Python scripting is a powerful technique for performing parametric studies or generating large databases. From the FEA results, using the regression method, a new burst pressure model was developed as a function of the vessel geometry (D/t ratio) and material properties (UTS and n). As validated by a large number of full-scale burst test data, the proposed burst model can very accurately predict the burst strength for both thin and thick-walled PVs.

42 ENGINEERING↗

Tracking the PACE of household energy usage: Energy usage impacts of projects financed through Property Assessed Clean Energy programs in California

This report examines the household-level energy impacts of residential property assessed clean energy (R-PACE) projects using normalized metered energy consumption methods. Our analysis covers projects that occurred through an R-PACE program between 2009 and 2017 and includes more than 25,000 electricity meters and 15,000 gas meters. We employ a comparison group, drawn from other R-PACE households with similar locational and usage characteristics whose projects were implemented at different times, to control for some non-project and non-weather factors that may impact energy use. We find that projects consisting of energy efficiency technologies save, on average, about 3% of household electricity usage and 3.5% of household gas usage. R-PACE financing, however, can be used to install central heating or air conditioning equipment for the first time. These projects would be expected to increase energy consumption. Since our data do not directly indicate which projects are new installations, we develop a simple algorithm for identifying them. Removing these inferred installation projects yields average savings of about 5% for electricity and 6% for gas for those households that remain in the sample. Given the mild California climate and the results of another study of similar California projects using similar methods, these results are in line with expectations. Solar PV projects yield large reductions in grid electricity use, averaging 69% of household consumption. We estimate that, collectively, all R-PACE projects installed in California through 2019 would generate annual reductions in grid-tied electricity consumption of 506 GWh (mostly due to solar PV) and gas consumption reductions of 2 million therms in a normal weather year. These impacts are equivalent to the electricity consumption of about 74,000 California households (including both efficiency and PV generation) and the gas consumption of about 4700 California households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Helium-4 gravitational form factors: Exchange currents

We evaluate the leading exchange corrections to the helium-4 gravitational form factors (GFFs) to momenta of the order of the nucleon mass. We use both the K-harmonic method with simple pair nucleon potential, and a Jastrow trial function using the Argonne 𝑣 14 potential, to evaluate the helium-4 GFFs. The exchange current contributions include the pair interaction, plus the seagull and the pion exchange interactions, modulo the recoil corrections. To estimate the off-shellness of the pion nucleon coupling in this momenta range, we discuss the results using either the pseudoscalar (PS) or pseudovector (PV) pion-nucleon couplings. When the PV coupling is used, the pair diagram contribution is higher order in the nonrelativistic expansion. The results for the helium-4 A-GFF are comparable to those given by the impulse approximation, especially for the PS coupling using both the K-harmonic method and variational method. The exchange current contributions with the PS coupling for the charge form factor of helium-4, yield better agreement with the existing data over a broad range of momenta, especially when the Argonne 𝑣 14 potential including the D-wave admixture is used.

A ≤ 5↗

Model-Free Voltage Control of Active Distribution System with PVs Using Surrogate Model-Based Deep Reinforcement Learning

Accurate knowledge of the distribution system topology and parameters is required to achieve good voltage control performance, but this is difficult to obtain in practice. This paper proposes a physical-model-free voltage control method based on a surrogate-model-enabled deep reinforcement learning approach. Specifically, a surrogate model is trained in a supervised manner using the recorded limited number of historical data to learn the relationship between the power injections and voltage fluctuations of each node. Then, the deep reinforcement learning algorithm is applied to learn an optimal control strategy from the experiences obtained by continuous interactions with the surrogate model. The proposed method can achieve physical-model-free control of unbalanced distribution network and inform real-time decisions to deal with fast voltage fluctuations caused by the rapid variation of PV generation. Simulation results on an unbalance IEEE 123-bus system show that the proposed method can achieve similar performance as that of perfect physical-model-based approaches while being advantageous over other traditional methods.

active distribution network↗

Increased panel height enhances cooling for photovoltaic solar farms

We report solar photovoltaic (PV) systems suffer substantial efficiency loss due to environmental and internal heating. However, increasing the canopy height of these systems promotes surface heat transfer and boosts production. This work represents the first wind tunnel experiments to explore this concept in terms of array flow behavior and relative convective heat transfer, comparing model solar arrays of varied height arrangements - a nominal height, extended height, and a staggered height configuration. Analyses of surface thermocouple data show average Nusselt number (Nu) to increase with array elevation, where panel convection at double height improved up to 1.88 times that of the nominal case. This behavior is an effect of sub-array entrainment of high velocity flow and panel interactions as evidenced through flow statistics and mean kinetic energy budgets on particle image velocimetry (PIV) data. The staggered height arrangement encourages faster sub-panel flow than in the nominal array. Despite sub-array blockage due to the lower panel interaction, heat shedding at panel surfaces promotes improvements on over 1.3 times that of the nominal height case.

14 SOLAR ENERGY↗

First Ever Polymer Flood Field Pilot To Enhance The Recovery Of Heavy Oils On Alaska’s North Slope - Pushing Ahead One Year Later

In June 2018 the team embarked on an ambitious project to address the slow development pace of Alaska’s 20+ billion barrels heavy oil resource via the first ever polymer flood pilot. Following the successful commencement of the pilot in August 2018, the field demonstration, supporting laboratory experiments and numerical simulation have steadily progressed. A significant amount of valuable data and lessons learned have been collected, and are reported in this paper. The ongoing pilot and the research activities is making headway toward the primary objective of validating the use of polymer flooding for extracting heavy oil in Alaska’s challenging environment. The pilot is conducted in two pre-existing pairs of horizontal injectors and producers in an isolated fault block of the Schrader Bluff heavy oil reservoir at the Milne Point Field. A customized polymer blending and pumping unit injects HPAM polymer at a concentration of 1,750 ppm to achieve a target viscosity of 45 cP. Supporting coreflood laboratory experiments have focused on quantification of polymer retention in the rock, and effect of injection water salinity, polymer, and their combinations on oil recovery. The injection and production response of the pilot flood pattern is utilized to develop a history matched reservoir simulation model for forecasting oil recovery beyond the pilot. Finally, specially designed laboratory experiments address anticipated operating concerns regarding post-polymer breakthrough such as oil-water separation efficiency and polymer induced fouling of heater tubes. Polymer has been injected continuously since startup except for two short equipment modification shutdowns, and more recently a prolonged disruption due to polymer hydration issues at the J-pad field site. Cumulatively, over 600,000 lbs. of polymer has been injected, corresponding to ~7%PV. The two producers show significant decrease in the water cut, gradually increasing oil rate, and no polymer breakthrough. Two main observations from the coreflood are a significant uncertainty in polymer retention values, and positive oil recovery response to low salinity water (2,600 mg/liter TDS). The heterogeneity in the flood pattern presents some challenges in obtaining a robust history matched simulation model. Experimental results on produced fluids treatment indicate the formation of a dense polymer deposit, at certain conditions, on heating tubes that can negatively impact the heat transfer efficiency. The scientific knowledge, including the lessons learned during unanticipated shutdowns, quality control, logistics and field data that is being acquired from this effort has referential value for other planned EOR projects. Finally, by all indications, the polymer field pilot is steadily progressing toward achieving the ultimate goal of unlocking the massive heavy oil resources on Alaska North Slope (ANS).

Dandekar, Abhijit↗

OCHRE

OCHRE™ uses a variety of input data sources to run time-series simulations. Building models can be taken from the ResStock™ database or generated using the Building Energy Optimization Tool (BEopt™) or other OpenStudio-HPXML workflows. EV charging profiles can be taken from datasets used in NLR's 2030 National Charging Network project. Weather data can be taken from the National Solar Radiation Database or EnergyPlus® weather files. There are no public datasets with OCHRE outputs at this time. However, a recent project dataset on water heater and EV demand flexibility can be requested. OCHRE is a Python-based energy modeling tool designed to model flexible loads in residential buildings. OCHRE includes detailed models and controls for flexible devices including HVAC equipment, water heaters, EVs, solar PV, and batteries. It is designed to run in co-simulation with custom controllers, aggregators, and grid models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The National Climate Database (NCDB): An Unbiased 100-Year Dataset for PV Modeling

In this study, we develop a statistical technique to downscale the future projection of solar irradiance for photovoltaics (PV) energy-related applications. A set of Regional Climate Model (RCM)-based projections obtained from the North American Coordinated Regional Climate Downscaling Experiment (NA-CORDEX) are used as inputs to statistical methods to generate high-resolution global horizontal irradiance (GHI) over the contiguous United States (CONUS). The main steps of the statistical downscaling method include (1) regridding RCM output (0.22 degree and daily resolutions) to handle the modeled-observed data sets on a common grid, (2) correcting bias of RCM GHI using satellite-derived observation, and (3) implementing temporal and spatial downscaling to generate GHI at 8-km and hourly resolution. Basically, complex physical processes and interactions between solar radiation and various atmospheric constituents lead solar irradiance to be highly variable and uncertain. Underrepresentation of clouds from the RCM parameterizations is the main source of error and uncertainty in modeling solar irradiance. Thus, we adapt and use the high-quality satellite-derived data from the National Solar Radiation Database (NSRDB) to analyze the bias and error of RCM GHI as well as estimate the statistical parameters for spatial and temporal downscaling. This presentation will summarize the comprehensive analysis conducted to produce and assess the results under two climate scenarios (RCP4.5 and RCP8.5). We will also present a detailed validation demonstrating the strengths of the downscaling method, a summary of the 100-year dataset from 2001-2100, and future extension of this research.

bias correction↗

Pricing Strategy of Electric Vehicle Aggregators Based on Locational Marginal Price to Minimize Photovoltaic (PV) Curtailment

The global climate crisis demands urgent action to mitigate global warming. Using renewable energy sources, such as solar and wind power, for electricity generation is crucial. This shift from centralized to distributed power systems, however, brings challenges, including voltage fluctuations and renewable energy curtailment. The rapid growth of the electric vehicle (EV) industry adds complexity, increasing overall electricity demand and straining the power supply during peak charging times. This paper proposes a scheduling strategy for EV aggregators to reduce renewable energy curtailment and stabilize grid operation by strategically scheduling EV charging. Using Multi -Agent Transport Simulation (MATSim), a traffic simulation tool, EV driving data in Denver, Colorado, USA, were modeled. The EV aggregator adjusts charging fees based on locational marginal prices, encouraging EVs to charge at different stations according to pricing. Simulations on an IEEE 33-bus system with distributed energy resources and EV charging stations validate the proposed algorithm, demonstrating its effectiveness in reducing curtailment by 12.55% and stabilizing grid operation.

33 ADVANCED PROPULSION SYSTEMS↗

Cybersecurity Certification Recommendations for Interconnected Grid Edge Devices and Inverter Based Resources

Escalating deployment of PV and grid-edge devices on the distribution grid has increased the sustainability and efficiency of the electric grid. However, the increasing number of distributed energy resources (DERs) deployed creates a heightened cyber-physical interdependency on the distribution grid and thus creates more vectors for cyber-attacks to exploit through information and communication technology (ICT) systems and networks. For example, control signal packets can be modified, intercepted, or corrupted due to vulnerabilities in communication protocols used by microgrid controllers and grid edge devices for power control. Therefore, to mitigate and prevent cyber-attacks on grid edge devices and the inverter-based resources connected to the distribution grid, the U.S. Department of Solar Energy Technologies Office (SETO) awarded funding to the National Renewable Energy Laboratory and Sandia National Laboratory (SNL) to research, develop, and harmonize cybersecurity standards for Photovoltaic (PV) systems and for other kinds of DERs. To help develop a standard for DER cybersecurity, NREL established certification recommendations and test cases, in consensus with the solar industry and UL, for ensuring intrinsic design security for DERs. These recommendations were developed to bolster the cybersecure functionalities such as TLS, MAC, CRL, session resumption/renegotiation, and password, system, and service security management within the DER devices. The proposed test cases verify authentication, authorization, confidentiality, and data integrity for data and communications of DERs that use Transmission Control Protocol/Internet Protocol (TCP/IP). They were also developed to protect DER communications from eavesdropping, replay, man-in-the-middle, denial of service (DoS), spoofing through security certificates, least-privilege violation, and brute-force credentials. This report, which has been validated and reviewed by UL, expands upon those test cases to provide DER cybersecurity certification recommendations which increase DER resiliency and help to mitigate cyber-attacks. UL's collaboration with NREL and approval of this document will accelerate the adoption of a UL standard for DER cybersecurity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review of Value of Solar Studies In Theory and In Practice

This brief summarizes a collection of state- and utility-commissioned value-of-solar (VoS) studies and related literature, with a focus on who commissioned the study, which value and cost categories were discussed and/or quantified, and the methods used. Our objective is to compile information on prior VoS studies to inform state regulators and other stakeholders that may pursue related studies or integrate findings into rate design. The brief is organized into three parts: 1) an introduction to distributed solar photovoltaic (DPV) compensation; 2) a review of theoretical research on VoS; and 3) a review of VoS studies. The vast majority of VoS studies have served an informational role of quantifying the net benefits of PV. Three studies were commissioned in states or utility service territories that subsequently implemented VoS tariffs in California, New York, and Austin, Texas. When applied as a tariff, VoS aims to compensate PV output as efficiently as possible by doing so at rates that reflect the marginal benefits and costs of PV through value and cost categories that may vary temporally and/or geographically. This could lead to higher compensation in locations and times where more PV output is more valuable and consequently drive adoption in those locations to provide more societal benefits. Value and cost factors can be broadly grouped into five categories: generation, transmission, distribution, other utility, and other social categories. Those conducting VoS studies must weigh various tradeoffs when deciding which categories to include and quantify. Tradeoffs include prioritizing values based on their magnitude of value or cost impact, as well as taking into account the feasibility of data collection and accurate quantification. Values of higher magnitude and estimation feasibility are quantified in the majority of studies, including the earliest of studies conducted in the 2000s and 2010s. Additionally, some values of higher magnitude but low feasibility in the earliest of studies have become quantifiable in recent years. There are some values with low average system-wide levels but very high magnitude in specific locations or hours. The value magnitude in some cases can be tied to DPV penetration with low value in areas with little congestion and/or low penetration and vice versa. In these cases, values that are easier to quantify are often incorporated, while those that are more difficult are often addressed via a placeholder value. The placeholder value is paired with a discussion around data needs and methods to improve future estimates, as well as a conversation about when these value categories may increase in magnitude and necessitate more rigorous quantification. This brief summarizes findings from two meta-analyses of VoS studies that took place between 2005 and 2018, as well as findings from four additional studies published from 2018 to 2023. Table ES-1 summarizes the various value and cost categories included in each respective study and whether they were quantified, discussed, or omitted. Values such as avoided energy, capacity, transmission capacity, line losses, and avoided environmental costs are quantified in every study. Some categories were deemed harder to quantify and less impactful at the time of the study, so they were discussed but not quantified (e.g., ancillary services). Other categories, including many at the distribution level, were very locationally and/or temporally specific and dependent on high DPV penetration. These were sometimes quantified and at other times discussed. Notably, when it came to utility costs, integration costs were discussed in all cases, though they were deemed to have a small impact. Other utility costs were omitted for the most part; however, the utility-commissioned study (by NorthWestern Energy in Montana) included both lost utility revenue and programmatic/administrative cost categories. While there are some similarities across studies, each had fairly unique methods that are detailed in the body of this brief.

14 SOLAR ENERGY↗

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY↗

The Renewable Energy Potential (reV) Model: A Geospatial Platform for Technical Potential and Supply Curve Modeling

The Renewable Energy Potential (reV) model is a platform for detailed assessment of renewable energy (RE) resources and their geospatial intersection with grid infrastructure and land use characteristics. The reV model currently supports photovoltaic (PV), concentrating solar power (CSP) and land-based wind turbine technologies. Modules in the reV framework function at different spatial and temporal resolutions, allowing for assessment of resource potential, technical potential and supply curves at varying levels of detail. The platform runs on NREL's High Performance Computing system, providing scalable and efficient performance from a single location all the way up to continental scales, for a single year or decades of time series resource data. Coupled with NREL's System Advisor Model (SAM), reV supports resource assessment from 5-minute to hourly temporal resolution and provides for analysis of long-term (i.e., year-on-year) variability of RE generation (e.g., interannual variability and exceedance probabilities). Technical potential is measured as a function of resource potential and limitations put on developable land area defined by the user. For example, the user can limit development by land ownership, terrain, land use/cover, and urban areas, as well as custom inputs. Technology, grid interconnection and operation costs, based on the latest market data and future projections, are also embedded in the model. The supply curve module is a spatial sorting algorithm based on plant siting, grid interconnection cost, and regional competition, which provides a geographically discrete estimate of levelized cost of electricity (LCOE) and supply (i.e., capacity) for specific renewable technologies. The reV model currently provides broad coverage across North America, South and Central Asia, South America and South Africa to inform national- and international-scale analyses as well as regional infrastructure and deployment planning.

13 HYDRO ENERGY↗