Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRISMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Lutetium(III) aqua ion: On the dynamical structure of the heaviest lanthanoid hydration complex

The structure and dynamics of the lutetium(III) ion in aqueous solution have been investigated by means of a polarizable force field molecular dynamics (MD). An 8-fold square antiprism (SAP) geometry has been found to be the dominant configuration of the lutetium(III) aqua ion. Nevertheless, a low percentage of 9-fold complexes arranged in a tricapped trigonal prism (TTP) geometry has been also detected. Dynamic properties have been explored by carrying out six independent MD simulations for each of four different temperatures: 277 K, 298 K, 423 K, 632 K. The mean residence time of water molecules in the first hydration shell at room temperature has been found to increase as compared to the central elements of the lanthanoid series in agreement with previous experimental findings. Water exchange kinetic rate constants at each temperature and activation parameters of the process have been determined from the MD simulations. The obtained structural and dynamical results suggest that the water exchange process for the lutetium(III) aqua ion proceeds with an associative mechanism, in which the SAP hydration complex undergoes temporary structural changes passing through a 9-fold TTP intermediate. Such results are consistent with the water exchange mechanism proposed for heavy lanthanoid atoms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solvothermal synthesis of Fe{sub 7}C{sub 3} and Fe{sub 3}C nanostructures with phase and morphology control

A phase transition, from orthorhombic Fe{sub 3}C to hexagonal Fe{sub 7}C{sub 3}, was observed using a wet synthesis mediated by hexadecyltrimethylammonium chloride (CTAC). In this study, CTAC has been shown to control carbide phase, morphology, and size of the iron carbide nanostructures. Fe{sub 7}C{sub 3} hexagonal prisms were formed with an average diameter of 960 nm, the thickness of 150 nm, and Fe{sub 3}C nanostructures with an approximate size of 50 nm. Magnetic studies show ferromagnetic behavior with M{sub s} of 126 emu/g, and H{sub c} of 170 Oe with respect to Fe{sub 7}C{sub 3} and 95 emu/g and 590 Oe with respect to Fe{sub 3}C. The thermal studies using high temperature x-ray diffraction show stability of Fe{sub 7}C{sub 3} up to 500 °C. Upon slow cooling, the Fe{sub 7}C{sub 3} phase is recovered with an intermediate oxide phase occurring around 300 °C. This study has demonstrated a simple route in synthesizing iron carbides for an in depth magnetic study and crystal phase transition study of Fe{sub 7}C{sub 3} at elevated temperatures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wavefront modulation and controlling for Lamb waves using surface bonded slice lenses

We present that there is a growing interest in controlling the propagation of Lamb waves to achieve better performance for structural health monitoring and nondestructive evaluation. In this study, we present new methods of controlling Lamb waves using simple slice lenses through wavefront modulation. The lenses are made of metal slices with designed shapes. Once bonded on plates, the lenses modify the effective plate thickness, and therefore change the Lamb wave characteristics such as the wavenumber and phase velocity, providing convenient ways of modulating wavefront and controlling Lamb waves in plates. Numerically and experimentally, we demonstrated that a straight wavefront A 0 mode can be focused on the desired focal point using a plano-concave aspherical lens. We also demonstrated that the A 0 mode can be steered with different frequency components steered to different directions using a simple prism made of metal slices. The work shows that such simple slice lenses provide easy ways for controlling Lamb waves, and have a great potential for Lamb wave based applications.

42 ENGINEERING↗

Unabsorbed light beamlets for diagnosing cross-beam energy transfer

Here, a new diagnostic has been fielded on OMEGA to diagnose cross-beam energy transfer (CBET) during direct-drive implosions. Unabsorbed light from each OMEGA laser beam is imaged as a distinct “spot” onto a gated optical imager. Each spot is in essence the end point of a beamlet of light that originates from different regions of each beam profile and follows a path determined by refraction. The intensity of light in the beamlet varies along its path as a result of absorption and CBET with other beamlets. This diagnostic allows the investigation of the effects of CBET on laser energy from specific locations of the beam profile. The diagnostic records images in two 200-ps time windows and includes a Wollaston prism to split each beamlet into two orthogonal polarizations recorded on separate images, allowing the absolute polarization of each beamlet to be determined. This diagnostic has provided the first evidence of polarization rotation caused by CBET during direct-drive implosions.

47 OTHER INSTRUMENTATION↗

Implementation of a Wollaston interferometry diagnostic on OMEGA EP

Here, a Wollaston interferometer is presented for use in measuring the electron density of plasma plumes created in experiments on the OMEGA EP laser system. The diagnostic is installed as an additional arm on the 4ω probe system, a suite of diagnostics that share a 10 ps pulse of 263 nm laser light captured by an imaging system at f /4. The interferometer utilizes a Wollaston prism to create two angularly separated beams from a single input probe beam, split at any angle between 0° and 90°. This configuration is implemented uniquely such that fringe spacing may be altered independently of field of view, magnification, and imaging resolution, from a range of 17 to 76 μm/fringe. The region of overlap between the two beams forms a total field of view of approximately 1.2 × 1.6 mm at the target chamber center with an imaging resolution of 5 μm. Using this configuration, here it is shown that plasma density may be accurately characterized over a range of 3 × 10 18 –1 × 10 20 cm -3 .

47 OTHER INSTRUMENTATION↗

A tunable path-separated electron interferometer with an amplitude-dividing grating beamsplitter

We demonstrate a tunable path-separated electron interferometer using a single amplitude-dividing beamsplitter to prepare multiple spatially isolated, coherent electron probe beams. We place four electrostatic bi-prisms in the optical column of a scanning transmission electron microscope (STEM) to achieve path separations of up to 25 μ m, the largest demonstrated within amplitude-division electron interferometers while maintaining fringe visibility of the directly observed interference fringes at the detector. We characterize the fringe visibility of this setup over a range of path separations and perform STEM holography to reconstruct the full object wave of a fabricated Si ramp test phase object. We report a quantitative object-wave measurement in this configuration and confirm with an independent off-axis electron holography measurement. This experimental design can potentially be applied to high-resolution phase imaging and fundamental physics experiments, such as an exploration of the electron wave packet coherence length and the Aharonov-Bohm effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A large field-of-view high-resolution hard x-ray microscope using polymer optics

Here, we present an effective approach using a matched pair of polymer-based condenser-objective lenses to build a compact full-field X-ray microscope with a high spatial resolution. A unique condenser comprising arrays of high-aspect-ratio prisms with equilateral cross-section is used for uniformly illuminating samples over a large field of view (FoV) from all angles, which match the acceptance of an objective made of interdigitated orthogonal rows of one-dimensional lenses. State-of-the-art Talbot grating interferometry used to characterize these lenses for the first time revealed excellent focusing properties and minimal wave-front distortions. Using a specific lens-pair designed for 20 keV X-rays, short-exposure times, and image registration with a cross-correlation technique, we circumvent vibrational instabilities to obtain distortion-free images with a uniform resolution of 240 nm (smallest resolvable line pair) over a large FoV, 80 × 80 µm 2 in extent. The results were contrasted with those collected under illumination using commercial two-dimensional parabolic lenses with a smaller FoV. This approach implemented on a diffractometer would enable diffraction-contrast or dark-field microscopy for fast observations of ‘mesoscopic’ phenomena in real space complementing reciprocal-space studies using diffraction on the same instrument.

47 OTHER INSTRUMENTATION↗

Use of a non-collinear wave mixing technique to image internal microscale damage in concrete

This research demonstrates the feasibility of using a non-collinear wave mixing technique to image internal microscale damage throughout the interior volume of a relatively large (28 cm thick) concrete component. By exploiting the underlying mechanics of nonlinear wave mixing, it is possible to mix two incident waves with frequencies low enough to propagate without being scattered by the inherently heterogenous, concrete microstructure, while still being sensitive to damage features with length scales well below these incident wavelengths. For this study, scanning and imaging is accomplished by manually adjusting the locations of the two incident waves, while a knowledge of the wave speeds in concrete plus synchronization identifies the location of the mixing zone—the specific volume of concrete being imaged. The viability of the proposed technique is demonstrated by examining a concrete prism specimen with known, embedded internal microscale damage.

Kim, Jin-Yeon (ORCID:0000000255180032)↗

Investigating the origin of the far-field reflection interference fringe (RIF) of microdroplets

We show that the reflection interference fringe (RIF) is formed on a screen far away from the microdroplets placed on a prism-based substrate, which have low contact angles and thin droplet heights, caused by the dual convex–concave profile of the droplet, not a pure convex profile. The geometric formulation shows that the interference fringes are caused by the optical path difference when the reflected rays from the upper convex profile at the droplet–air interface interfere with reflection from the lower concave profile at oblique angles lower than the critical angle. Analytic solutions are obtained for the droplet height and the contact angle out of the fringe number and the fringe radius in RIF from the geometric formulation. Furthermore, the ray tracing simulation is conducted using the custom-designed code. The geometric formulation and the ray tracing show excellent agreement with the experimental observation in the relation between the droplet height and the fringe number and the relation between the contact angle and the fringe radius. This study is remarkable as the droplet's dual profile cannot be easily observed with the existing techniques. However, the RIF technique can effectively verify the existence of a dual profile of the microdroplets in a simple setup. In this work, the RIF technique is successfully developed as a new optical diagnostic technique to determine the microdroplet features, such as the dual profile, the height, the contact angle, the inflection point, and the precursor film thickness, by simply measuring the RIF patterns on the far-field screen.

42 ENGINEERING↗

Transmission interference fringe ( TIF ) technique for the dynamic visualization of evaporating droplet

Here, the transmission interference fringe (TIF) technique was developed to visualize the dynamics of evaporating droplets based on the Reflection Interference Fringe (RIF) technique for micro-sized droplets. The geometric formulation was conducted to determine the contact angle (CA) and height of macro-sized droplets without the need for the prism used in RIF. The TIF characteristics were analyzed through experiments and simulations to demonstrate a wider range of contact angles from 0 to 90°, in contrast to RIF's limited range of 0–30°. TIF was utilized to visualize the dynamic evaporation of droplets in the constant contact radius (CCR) mode, observing the droplet profile change from convex-only to convex-concave at the end of dry-out from the interference fringe formation. The TIF also observed the contact angle increase from the fringe radius increase. This observation is uniquely reported as the interference fringe (IF) technique can detect the formation of interference fringe between the reflection from the center convex profile and the reflection from the edge concave profile on the far-field screen. Unlike general microscopy techniques, TIF can detect far-field interference fringes as it focuses beyond the droplet-substrate interface. The formation of the convex-concave profile during CCR evaporation is believed to be influenced by the non-uniform evaporative flux along the droplet surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The mechanics of nucleation and growth and the surface tensions of active matter

Homogeneous nucleation, a textbook transition path for phase transitions, is typically understood on thermodynamic grounds through the prism of classical nucleation theory. However, recent studies have suggested the applicability of classical nucleation theory to systems far from equilibrium. Here, in this article, we formulate a purely mechanical perspective of homogeneous nucleation and growth, elucidating the criteria for the properties of a critical nucleus without appealing to equilibrium notions. Applying this theory to active fluids undergoing motility-induced phase separation, we find that nucleation proceeds in a qualitatively similar fashion to equilibrium systems, with concepts such as the Gibbs–Thomson effect and nucleation barriers remaining valid. We further demonstrate that the recovery of such concepts allows us to extend classical theories of nucleation rates and coarsening dynamics to active systems upon using the mechanically derived definitions of the nucleation barrier and surface tensions. Three distinct surface tensions—the mechanical, capillary, and Ostwald tensions—play a central role in our theory. While these three surface tensions are identical in equilibrium, our work highlights the distinctive role of each tension in the stability of active interfaces and the nucleation and growth of motility-induced phases.

Capillary waves↗

Interference fringe (IF) technique for droplet contact angle and thickness measurements: Ultralow contact angle and nanoscale thickness measurement

Recently, reflection interference fringe (RIF) and transmission fringe (TIF) techniques have been introduced to investigate the origin of far-field interference fringe (IF) formation and to determine a droplet's contact angle and thickness by measuring the fringe radius. In this study, characteristics of the IF technique are analyzed based on the RIF and TIF by varying the schematics, such as configuration (transmission/reflection), the droplet's side (left-hand side/right-hand side), and the substrate types (flat/prism). The analysis also investigates the refraction effect at the droplet edge and the maximum incidence and contact angles. The schematic variation shows that the widest contact angle range can be measured in a transmission configuration with droplet's right-hand side, and that the fringe radius decreases with incidence angles on a prism substrate, consistent with the recent observation. Refraction at the droplet edge causes the fringe radius to increase or decrease depending on the degree of refraction. Based on the characteristics study, it is revealed that the IF technique can determine nanometer-scale thicknesses below 100 nm on droplets, corresponding to ultra-small contact angles of less than 0.01°, with an extended working distance of 3000 mm and an optimized incidence angle, assuming a spherical profile. This finding is significant, as it demonstrates that the nanoscale thickness can be determined in situ under ambient conditions using a simple optical configuration, without requiring a sophisticated setup, such as a microscope. It is anticipated that the IF technique can be combined with other nanoscale thickness measurement techniques to enhance its measurement reliability.

36 MATERIALS SCIENCE↗

Pulsed Fe{sup 2+}:ZnS laser continuously tunable in the wavelength range of 3.49 - 4.65 {mu}m

A laser based on a Fe{sup 2+}:ZnS crystal is demonstrated for the first time. Lasing in this crystal is obtained at room temperature under pumping by 40-ns pulses of an Er:YAG laser at a wavelength of 2.94 nm. The slope efficiency of the Fe{sup 2+}:ZnS laser with respect to the absorbed pump energy was 32%, and the output energy reached 3.4 mJ. Continuous tuning of the laser wavelength within the range of 3.49 - 4.65 nm was achieved using an intracavity dispersion prism. (lasers)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Angular dependences of the luminescence and density of photon states in a chiral liquid crystal

Luminescence spectra of a laser dye-doped chiral liquid crystal have been studied in a wide range of angles (up to 60°) to the axis of its helical structure using a semicylindrical quartz prism, which made it possible to observe the shift and evolution of the photonic band gap in response to changes in angle. Using measured spectra and numerical simulation, we calculated the spectral distributions of the density of photon states in such a cholesteric crystal for polarised and unpolarised light, which characterise its structure as that of a chiral one-dimensional photonic crystal. (optics of liquid crystals)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determination of refractive index, extinction coefficient and thickness of thin films by the method of waveguide mode excitation

We propose a method for measuring simultaneously the refractive index n{sub f}, extinction coefficient m{sub f} and thickness H{sub f} of thin films. The method is based on the resonant excitation of waveguide modes in the film by a TE- or a TM-polarised laser beam in the geometry of frustrated total internal reflection. The values of n{sub f}, m{sub f} and H{sub f} are found by minimising the functional φ = [N{sup -1}Σ{sup N}{sub i=1}(R{sub exp}(θ{sub i}) – R{sub thr}(θ{sub i})){sup 2}]{sup 1/2}, where R{sub exp}(θ{sub i}) and R{sub thr}(θ{sub i}) are the experimental and theoretical coefficients of reflection of the light beam from the interface between the measuring prism and the film at an angle of incidence θ{sub i}. The errors in determining n{sub f}, m{sub f} and H{sub f} by this method are ±2 × 10{sup -4}, ±1 × 10{sup -3} and ±0.5%, respectively. (fiber and integrated optics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Antibody-free, targeted mass-spectrometric approach for quantification of proteins at low picogram per milliliter levels in human plasma/serum

The detection and quantification of proteins at sub-ng/mL concentrations in plasma/serum is of critical importance for candidate biomarker verification. Sensitive detection of serum proteins has typically been achieved by immunoassays; however, de novo development of antibodies is associated with high cost and long lead time. To address this challenge, we developed an antibody-free strategy, termed high-pressure high-resolution separations with intelligent selection and multiplexing (PRISM), for achieving accurate detection of proteins at ~50 pg/mL level in plasma/serum using selected reaction monitoring (SRM). This strategy is based on high resolution reversed phase liquid chromatographic separations for analyte enrichment along with intelligent selection of target fractions via on-line SRM monitoring of internal standards and fraction multiplexing prior to SRM quantification. Our work represents a major technological advance for achieving pg/mL level of serum protein quantification without specific affinity reagents and holds great promise for broad applications in biomarker verification and systems biology studies.

biomarker verification↗

From particle attachment to space-filling coral skeletons

Reef-building corals and their aragonite (CaCO 3 ) skeletons support entire reef ecosystems, yet their formation mechanism is poorly understood. Here we used synchrotron spectromicroscopy to observe the nanoscale mineralogy of fresh, forming skeletons from six species spanning all reef-forming coral morphologies: Branching, encrusting, massive, and table. In all species, hydrated and anhydrous amorphous calcium carbonate nanoparticles were precursors for skeletal growth, as previously observed in a single species. The amorphous precursors here were observed in tissue, between tissue and skeleton, and at growth fronts of the skeleton, within a low-density nano- or microporous layer varying in thickness from 7 to 20 µm. Brunauer-Emmett-Teller measurements, however, indicated that the mature skeletons at the microscale were space-filling, comparable to single crystals of geologic aragonite. Nanoparticles alone can never fill space completely, thus ion-by-ion filling must be invoked to fill interstitial pores. Such ion-by-ion diffusion and attachment may occur from the supersaturated calcifying fluid known to exist in corals, or from a dense liquid precursor, observed in synthetic systems but never in biogenic ones. Concomitant particle attachment and ion-by-ion filling was previously observed in synthetic calcite rhombohedra, but never in aragonite pseudohexagonal prisms, synthetic or biogenic, as observed here. Models for biomineral growth, isotope incorporation, and coral skeletons’ resilience to ocean warming and acidification must take into account the dual formation mechanism, including particle attachment and ion-by-ion space filling.

59 BASIC BIOLOGICAL SCIENCES↗