Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Open”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Accessing trigluon correlations in the nucleon via the single spin asymmetry in open charm production

We calculate the single transverse-spin asymmetry for open charm production in pp collisions within the QCD collinear factorization approach. We include contributions from both twist-three quark-gluon and trigluon correlation functions. We find that the quark-gluon correlation functions alone generate only a very small asymmetry for open charm production in the kinematic region of current interest at RHIC, so that the observation of any significant single-spin asymmetry would be a clear indication of the presence of trigluon correlations inside a polarized proton. We furthermore demonstrate that the trigluon contribution could be very different for the production of D and D mesons. These features make the single-spin asymmetry in open charm production in polarized pp collisions at RHIC an excellent probe of trigluon correlation functions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Jet substructure studies with CMS open data

We utilize public data from the CMS experiment to study the two-prong substructure of jets. The CMS open data are based on 31.8 pb -1 of 7 TeV proton-proton collisions recorded at the Large Hadron Collider in 2010, yielding a sample of 768,687 events containing a high-quality central jet with transverse momentum larger than 85 GeV. Using CMS’s particle flow reconstruction algorithm to obtain jet constituents, we extract the two-prong substructure of the leading jet using soft-drop declustering. We find good agreement between results obtained from the CMS open data and those obtained from parton shower generators, and we also compare to analytic jet substructure calculations performed to modified leading-logarithmic accuracy. Even though the 2010 CMS open data do not include simulated data to help estimate systematic uncertainties, we use track-only observables to validate these substructure studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Escape of quantum particles from an open cavity

A negative ion irradiated by a laser provides a coherent source of electrons propagating out from the location of the negative ion. The total escape rates of the electrons when the negative ion is placed inside an open cavity in the shape of a wedge are studied. It is shown that the wedge induces significant oscillations in the total escape rates because of quantum interference effects. In particular, it is shown that, for a wedge with an opening angle of {pi}/N, where N is an arbitrary positive integer, there are (2N-1) induced oscillations in the rates. As a demonstration, the case for a wedge with an opening angle {pi}/5 is calculated and analyzed in detail.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum Simulation of Open Quantum Systems Using a Unitary Decomposition of Operators

Electron transport in realistic physical and chemical systems often involves the nontrivial exchange of energy with a large environment, requiring the definition and treatment of open quantum systems. Because the time evolution of an open quantum system employs a nonunitary operator, the simulation of open quantum systems presents a challenge for universal quantum computers constructed from only unitary operators or gates. Here, we present a general algorithm for implementing the action of any nonunitary operator on an arbitrary state on a quantum device. We show that any quantum operator can be exactly decomposed as a linear combination of at most four unitary operators. We demonstrate this method on a two-level system in both zero and finite temperature amplitude damping channels. Furthermore, the results are in agreement with classical calculations, showing promise in simulating nonunitary operations on intermediate-term and future quantum devices.

74 ATOMIC AND MOLECULAR PHYSICS↗

Simulation of open quantum systems via low-depth convex unitary evolutions

Simulating physical systems on quantum devices is one of the most promising applications of quantum technology. Current quantum approaches to simulating open quantum systems are still practically challenging on NISQ-era devices, because they typically require ancilla qubits and extensive controlled sequences. In this work, we propose a hybrid quantum-classical approach for simulating a class of open system dynamics called random-unitary channels. These channels naturally decompose into a series of convex unitary evolutions, which can then be efficiently sampled and run as independent circuits. The method does not require deep ancilla frameworks and thus can be implemented with lower noise costs. We implement simulations of open quantum systems up to dozens of qubits and with large channel ranks. Published by the American Physical Society 2024

Peetz, Joseph (ORCID:0000000274458028)↗

Spontaneous Gap Opening and Potential Excitonic States in an Ideal Dirac Semimetal Ta 2 Pd 3 Te 5

The opening of an energy gap in the electronic structure generally indicates the presence of interactions. In materials with low carrier density and short screening length, long-range Coulomb interaction favors the spontaneous formation of electron-hole pairs, so called excitons, opening an excitonic gap at the Fermi level. Excitonic materials host unique phenomena associated with pair excitations. However, there is still no generally recognized single-crystal material with excitonic order, which is, therefore, awaited in condensed matter physics. Here, we show that excitonic states may exist in the quasi-one-dimensional material Ta 2 Pd 3 Te 5 , which has an almost ideal Dirac-like band structure, with the Dirac point located exactly at the Fermi level. We find that an energy gap appears at 350 K, and it grows with decreasing temperature. The spontaneous gap opening is absent in a similar material Ta 2 Ni 3 Te 5 . Intriguingly, the gap is destroyed by the potassium deposition on the crystal, likely due to extra-doped carriers. Furthermore, we observe a pair of in-gap flat bands, which is an analog of the impurity states in a superconducting gap. All these observations can be properly explained by an excitonic order, providing Ta 2 Pd 3 Te 5 as a new and promising candidate realizing excitonic states. Published by the American Physical Society 2024

Zhang, Peng (ORCID:0000000225634670)↗

Open-source electrochemical cell for in situ X-ray absorption spectroscopy in transmission and fluorescence modes

X-ray spectroscopy is a valuable technique for the study of many materials systems. Characterizing reactions in situ and operando can reveal complex reaction kinetics, which is crucial to understanding active site composition and reaction mechanisms. In this project, the design, fabrication and testing of an open-source and easy-to-fabricate electrochemical cell for in situ electrochemistry compatible with X-ray absorption spectroscopy in both transmission and fluorescence modes are accomplished via windows with large opening angles on both the upstream and downstream sides of the cell. Using a hobbyist computer numerical control machine and free 3D CAD software, anyone can make a reliable electrochemical cell using this design. Onion-like carbon nanoparticles, with a 1:3 iron-to-cobalt ratio, were drop-coated onto carbon paper for testing in situ X-ray absorption spectroscopy. Cyclic voltammetry of the carbon paper showed the expected behavior, with no increased ohmic drop, even in sandwiched cells. Chronoamperometry was used to apply 0.4 V versus reversible hydrogen electrode, with and without 15 min of oxygen purging to ensure that the electrochemical cell does not provide any artefacts due to gas purging. The XANES and EXAFS spectra showed no differences with and without oxygen, as expected at 0.4 V, without any artefacts due to gas purging. The development of this open-source electrochemical cell design allows for improved collection of in situ X-ray absorption spectroscopy data and enables researchers to perform both transmission and fluorescence simultaneously. It additionally addresses key practical considerations including gas purging, reduced ionic resistance and leak prevention.

08 HYDROGEN↗

Evaluating Conservation Voltage Reduction: An Application of GridLAB-D: an Open Source Software Package

Voltage Reduction (CVR) is the reduction of energy consumption resulting from a reduction of the service voltage. While there have been numerous CVR deployments in North America, there has been little substantive analytic analysis of the effect; the majority of the published results are based on empirical field measurements. Due to the lack of analytic study, it is difficult to determine the impacts of CVR outside of sites that have conducted demonstration projects. This panel paper will examine a framework for the analysis of CVR using the open source software package GridLAB-D. An open source simulation environment is used to highlight the effectiveness of open source software programs and their ability to be used for evaluating multi-disciplinary smart grid technologies.

Schneider, Kevin P.↗

Accounting for spectroscopic effects in laser‐based open‐path eddy covariance flux measurements

Abstract A significant portion of the production and consumption of trace gases (e.g. CO 2 , CH 4 , N 2 O, NH 3 , etc.) by world ecosystems occurs in areas without sufficient infrastructure or easily available grid power to run traditional closed‐path flux stations. Open‐path analyzer design allows such measurements with power consumption 10–150 times below present closed‐path technologies, helping to considerably expand the global coverage and improve the estimates of gas emissions and budgets, informing the remote sensing and modeling communities and policy decisions, all the way to IPCC reports. Broad‐band nondispersive infrared devices have been used for open‐path CO 2 and H 2 O measurements since the late 1970s, but since recently, a growing number of new narrow‐band laser‐based instruments are being rapidly developed. The new design comes with its own challenges, specifically: (a) mirror contamination, and (b) uncontrolled air temperature, pressure and humidity, affecting both the gas density and the laser spectroscopy of the measurements. While the contamination can be addressed via automated cleaning, and density effects can be addressed via the Webb‐Pearman‐Leuning approach, the spectroscopic effects of the in situ temperature, pressure and humidity fluctuations on laser‐measured densities remain a standing methodological question. Here we propose a concept accounting for such effects in the same manner as Webb et al. proposed to account for respective density effects. Derivations are provided for a general case of flux of any gas, examined using a specific example of CH 4 fluxes from a commercially available analyzer, and then tested using “zero‐flux” experiment. The proposed approach helps reduce errors in open‐path, enclosed, and temperature‐ or pressure‐uncontrolled closed‐path laser‐based flux measurements due to the spectroscopic effects from few percents to multiple folds, leading to methodological advancement and geographical expansion of the use of such systems providing reliable and consistent results for process‐level studies, remote sensing and Earth modeling applications, and GHG policy decision‐making.

Burba, George↗

SU-D-BRA-02: Motion Assessment During Open Face Mask SRS Using CBCT and Surface Monitoring

Purpose: To assess the robustness of immobilization using open-face mask technology for linac-based stereotactic radiosurgery (SRS) with multiple non-coplanar arcs via repeated CBCT acquisition, with comparison to contemporaneous optical surface tracking data. Methods: 25 patients were treated in open faced masks with cranial SRS using 3–4 non-coplanar arcs. Repeated CBCT imaging was performed to verify the maintenance of proper patient positioning during treatment. Initial patient positioning was performed based on prescribed shifts and optical surface tracking. Positioning refinements employed rigid 3D-matching of the planning CT and CBCT images and were implemented via automated 6DOF couch control. CBCT imaging was repeated following the treatment of all non-transverse beams with associated couch kicks. Detected patient translations and rotations were recorded and automatically corrected. Optical surface tracking was applied throughout the treatments to monitor motion, and this contemporaneous patient positioning data was recorded to compare against CBCT data and 6DOF couch adjustments. Results: Initial patient positions were refined on average by translations of 3±1mm and rotations of ±0.9-degrees. Optical surface tracking corroborated couch corrections to within 1±1mm and ±0.4-degrees. Following treatment of the transverse and subsequent superior-oblique beam, average translations of 0.6±0.4mm and rotations of ±0.4-degrees were reported via CBCT, with optical surface tracking in agreement to within 1.1±0.6mm and ±0.6-degrees. Following treatment of the third beam, CBCT indicated additional translations of 0.4±0.2mm and rotations of ±0.3-degrees. Cumulative couch corrections resulted in 0.7 ± 0.4mm average magnitude translations and rotations of ±0.4-degrees. Conclusion: Based on CBCT measurements of patients during SRS, the open face mask maintained patient positioning to within 1.5mm and 1-degree with >95% confidence. Patient positioning determined by optical surface tracking agreed with CBCT assessment to within 1±1mm and ±0.6-degree rotations. These data support the use of 1–2mm PTV margins and repeated CBCT to maintain stereotactic positioning tolerances.

60 APPLIED LIFE SCIENCES↗

SU-F-J-18: Feasibility of Open Mask Immobilization with Optical Imaging Guidance (OIG) for H&N Radiotherapy

Purpose: Full face and neck thermoplastic masks provide standard-of-care immobilization for patients receiving H&N IMRT. However, these masks are uncomfortable and increase skin dose. The purpose of this pilot study was to investigate the feasibility and setup accuracy of open face and neck mask immobilization with OIG. Methods: Ten patients were consented and enrolled to this IRB-approved protocol. Patients were immobilized with open masks securing only forehead and chin. Standard IMRT to 60–70 Gy in 30 fractions were delivered in all cases. Patient simulation information, including isocenter location and CT skin contours, were imported to a commercial OIG system. On the first day of treatment, patients were initially set up to surface markings and then OIG referenced to face and neck skin regions of interest (ROI) localized on simulation CT images, followed by in-room CBCT. CBCTs were acquired at least weekly while planar OBI was acquired on the days without CBCT. Following 6D robotic couch correction with kV imaging, a new optical real-time surface image was acquired to track intrafraction motion and to serve as a reference surface for setup at the next treatment fraction. Therapists manually recorded total treatment time as well as couch shifts based on kV imaging. Intrafractional ROI motion tracking was automatically recorded. Results: Setup accuracy of OIG was compared with CBCT results. The setup error based on OIG was represented as a 6D shift (vertical/longitudinal/lateral/rotation/pitch/roll). Mean error values were −0.70±3.04mm, −0.69±2.77mm, 0.33±2.67 mm, −0.14±0.94 o, −0.15±1.10o and 0.12±0.82o, respectively for the cohort. Average treatment time was 24.1±9.2 minutes, comparable to standard immobilization. The amplitude of intrafractional ROI motion was 0.69±0.36 mm, driven primarily by respiratory neck motion. Conclusion: OGI can potentially provide accurate setup and treatment tracking for open face and neck immobilization. Study accrual and patient/provider satisfaction survey collection remain ongoing. This study is supported by VisionRT, Ltd.

60 APPLIED LIFE SCIENCES↗

SU-F-T-667: Development and Validation of Dose Calculation for An Open-Source KV Treatment Planning System for Small Animal Radiotherapy

Purpose: An open-source, convolution/superposition based kV-treatment planning system(TPS) was developed for small animal radiotherapy from previously existed in-house MV-TPS. It is flexible and applicable to both step and shoot and helical tomotherapy treatment delivery. For initial commissioning process, the dose calculation from kV-TPS was compared with measurements and Monte Carlo(MC) simulations. Methods: High resolution, low energy kernels were simulated using EGSnrc user code EDKnrc, which was used as an input in kV-TPS together with MC-simulated x-ray beam spectrum. The Blue Water™ homogeneous phantom (with film inserts) and heterogeneous phantom (with film and TLD inserts) were fabricated. Phantom was placed at 100cm SSD, and was irradiated with 250 kVp beam for 10mins with 1.1cm × 1.1cm open field (at 100cm) created by newly designed binary micro-MLC assembly positioned at 90cm SSD. Gafchromic™ EBT3 film was calibrated in-phantom following AAPM TG-61 guidelines, and were used for measurement at 5 different depths in phantom. Calibrated TLD-100s were obtained from ADCL. EGS and MNCP5 simulation were used to model experimental irradiation set up calculation of dose in phantom. Results: Using the homogeneous phantom, dose difference between film and kV-TPS was calculated: mean(x)=0.9%; maximum difference(MD)=3.1%; standard deviation(σ)=1.1%. Dose difference between MCNP5 and kV-TPS was: x=1.5%; MD=4.6%; σ=1.9%. Dose difference between EGS and kV-TPS was: x=0.8%; MD=1.9%; σ=0.8%. Using the heterogeneous phantom, dose difference between film and kV-TPS was: x=2.6%; MD=3%; σ=1.1%; and dose difference between TLD and kV-TPS was: x=2.9%; MD=6.4%; σ=2.5%. Conclusion: The inhouse, open-source kV-TPS dose calculation system was comparable within 5% of measurements and MC simulations in both homogeneous and heterogeneous phantoms. The dose calculation system of the kV-TPS is validated as a part of initial commissioning process for small animal radiotherapy. The kV-TPS has the potential for accurate dose calculation for any kV treatment or imaging modalities.

60 APPLIED LIFE SCIENCES↗

Dual structure of saturated absorption resonance at an open atomic transition

Experiments on open transitions of the D{sub 1} line of alkali metals (Cs and Rb isotopes) reveal the dual structure of saturated absorption resonance in the signal of a high-intensity optical wave in the presence of a low-intensity counterpropagating wave. Theoretical analysis shows that the observed shape of the resonance is associated with the openness of the atomic transition as well as with the Doppler effect for atoms in a gas. The results are of general physical significance for nonlinear spectroscopy and can also find application in metrology (frequency and time standards on open transitions).

74 ATOMIC AND MOLECULAR PHYSICS↗

Compton scattering of an X-ray photon by an open-shell atom

A nonrelativistic quantum theory for the nonresonant Compton scattering of an X-ray photon by a free many-electron atom with an open shell in the ground state has been constructed in the single-configuration Hartree-Fock approximation outside the impulse approximation widely used in the literature. The transition to an atom with closed shells reproduces the results obtained previously in [6, 7]. The results of a test calculation for atoms with open (Ti, Fe) and closed (Zn) 3d core shells are presented. The effects of the radial relaxation of one-electron states in the field of core vacancies have been taken into account. The results of the calculation agree well with the experimental results [15, 16]. It has been established that the results of the impulse approximation in the investigated X-ray photon energy ranges disagree with those of our theory not only quantitatively but also qualitatively. In particular, the impulse approximation near the elastic (Thomson and Rayleigh) scattering line leads to a gross overestimation of the contributions from the deep atomic shells involved in the inelastic photon scattering only virtually to the scattering probability. The presented theory is general in character and its applicability to a particular element of the Mendeleev table with an open core shell or to a many-electron atomic ion is limited only by the requirement that the nonrelativistic Hartree-Fock approximation be properly used in describing the scattering-state wave functions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Breakdown in helium in high-voltage open discharge with subnanosecond current front rise

Investigations of high-voltage open discharge in helium have shown a possibility of generation of current pulses with subnanosecond front rise, due to ultra-fast breakdown development. The open discharge is ignited between two planar cathodes with mesh anode in the middle between them. For gas pressure 6 Torr and 20 kV applied voltage, the rate of current rise reaches 500 A/(cm{sup 2} ns) for current density 200 A/cm{sup 2} and more. The time of breakdown development was measured for different helium pressures and a kinetic model of breakdown in open discharge is presented, based on elementary reactions for electrons, ions and fast atoms. The model also includes various cathode emission processes due to cathode bombardment by ions, fast atoms, electrons and photons of resonant radiation with Doppler shift of frequency. It is shown, that the dominating emission processes depend on the evolution of the discharge voltage during the breakdown. In the simulations, two cases of voltage behavior were considered: (i) the voltage is kept constant during the breakdown; (ii) the voltage is reduced with the growth of current. For the first case, the exponentially growing current is maintained due to photoemission by the resonant photons with Doppler-shifted frequency. For the second case, the dominating factor of current growth is the secondary electron emission. In both cases, the subnanosecond rise of discharge current was obtained. Also the effect of gas pressure on breakdown development was considered. It was found that for 20 Torr gas pressure the time of current rise decreases to 0.1 ns, which is in agreement with experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Azure Data Tools (FKA: OEDI (Open Energy Data Initiative) Data Access Tools) [SWR-23-92]

The Open Energy Data Initiative (OEDI) provides a number of tools to enable the use of the open data published through this initiative. The source is largely written in Python, including Jupyter notebooks. The Open Energy Data Initiative (OEDI) is a partnership between the National Renewable Energy Laboratory (NREL), the U.S. Department of Energy (DOE), Amazon, Microsoft, and Google to provide universal access to big data in the cloud. At the heart of OEDI is a centralized repository of high-value energy research datasets aggregated from DOE Program Offices, National Laboratories and other collaborators.

Jonathan, Weers↗

LiAISON (Life-cycle Assessment Integration into Scalable Open-source Numerical models) [SWR-24-01]

We introduce an open source prospective LCA framework, the Life-cycle Assessment Integration into Scalable Open-source Numerical models (LiAISON), to analyze the non-linear relationships between technology foreground and the future energy system background across a series of midpoint and resource use metrics The integration of LCA and IAM data is achieved using prospective environmental Impact assessment (PREMISE)7. We showcase it by assessing two Power-to-Hydrogen (PtH2) processes, namely Solid Oxide Electrolysis (SOE) and Polymer Electrolyte Membrane Electrolysis (PEME). We compare the technologies to a baseline of hydrogen production via natural gas-based Steam Methane Reforming (SMR) in a US context of multiple energy system and climate change mitigation futures. Besides providing an analysis that specifies the LCA results ranges with temporal and geospatial explicitness across the two technologies, metrics, and impact assessment methods, this research also aims to establish a base framework that can be expanded to use other IAM generated scenarios and US open-source life cycle inventory (LCI) databases. We find that the temporal environmental performance of either technology or their difference to SMR is directly influenced by the underlying background dynamics. Under baseline projections (i.e., no decarbonization goals), neither process reaches parity with the incumbent technology across several environmental metrics. Under the decarbonization scenarios, the underlying sectoral shifts result in declining impacts over time, compared to 2020 levels, except for metal depletion levels, which increase. The background shifts postulate a heavily decarbonized economy and energy system, which help technologies reach parity with SMR between 2040-2050 (RCP2.6) and 2030-2040 (RCP1.9) for global warming. Despite declines across several other metrics over time, neither PtH2 technology break even with SMR by 2100 besides for global warming. Scientific publication available here: https://pubs.acs.org/doi/full/10.1021/acs.est.2c04246

Ghosh, Tapajyoti↗

Closed headpiece of integrin [alpah]IIb[beta]3 and its complex with an [alpha]IIb[beta]3-specific antagonist that does not induce opening

The platelet integrin {alpha}{sub IIb}{beta}{sub 3} is essential for hemostasis and thrombosis through its binding of adhesive plasma proteins. We have determined crystal structures of the {alpha}{sub IIb}{beta}{sub 3} headpiece in the absence of ligand and after soaking in RUC-1, a novel small molecule antagonist. In the absence of ligand, the {alpha}{sub IIb}{beta}{sub 3} headpiece is in a closed conformation, distinct from the open conformation visualized in presence of Arg-Gly-Asp (RGD) antagonists. In contrast to RGD antagonists, RUC-1 binds only to the {alpha}{sub IIb} subunit. Molecular dynamics revealed nearly identical binding. Two species-specific residues, {alpha}{sub IIb} Y190 and {alpha}{sub aIIb} D232, in the RUC-1 binding site were confirmed as important by mutagenesis. In sharp contrast to RGD-based antagonists, RUC-1 did not induce {alpha}{sub IIb}{beta}{sub 3} to adopt an open conformation, as determined by gel filtration and dynamic light scattering. These studies provide insights into the factors that regulate integrin headpiece opening, and demonstrate the molecular basis for a novel mechanism of integrin antagonism.

59 BASIC BIOLOGICAL SCIENCES↗