Interaction between step fuel injectors on opposite walls in a supersonic combustor model
Results are presented from an experimental investigation of perpendicular, hydrogen fuel injection and combustion from opposing walls in a scramjet combustor model using a longitudinally staged laterally inline step-injection configuration. The model represents a portion of the flow in the Langley integrated modular scramjet engine combustor operating at a flight Mach number of 7. When operating at a ratio of jet pressure to free-stream dynamic pressure of 3, the injectors produce a bulk equivalence ratio of unity. This investigation represents part of a continuing study of the modular engine fuel injectors and is specifically designed to eliminate the adverse lateral pressure gradient observed at the injector location in a previous test. Flow survey contours at three axial locations, ranging from one-third of the engine combustor length to the total engine combustor length, are used to determine mixing efficiency and fuel distribution. Wall static pressures are analyzed by using one-dimensional theory to determine the combustion efficiency. Results show a significant improvement over previous injector designs tested in this duct geometry.