Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupancy distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Nuclear Safety [Vol. 32, No. 4, October-December 1991]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 477 Report on the International Symposium on the Use of Probabilistic Safety Assessment for Operational Safety—PSA '91, S. Chakraborty and M. Khatib-Rahbar; 488 Good Relationships Are Pivotal in Nuclear Data Bases, A. S. Heger and B. V. Koen; 494 Technical Note: The Interagency Nuclear Safety Review Panel's Evaluation of the Ulysses Space Mission, J. A. Sholtis, Jr., D. A. Huff, L. B. Gray, N. P. Klug, and R. O. Winchester; ACCIDENT ANALYSIS: 502 The Severe Accident Analysis Program for the Savannah River Nuclear Production Reactors, M. L. Hyder; CONTROL AND INSTRUMENTATION: 511 A Framework for Selecting Suitable Control Technologies for Nuclear Power Plant Systems, R. A. Kisner; DESIGN FEATURES: 521 Containments for Gas-Cooled Power Reactors History and Status, P.W. Williams; ENVIRONMENTAL EFFECTS: 537 Indoor Radon: A Natural Risk, N. H. Harley and J.H. Harley; On the Importance of the Atmospheric Parameters in the Fission Products Distribution of a Severe Reactor Accident, M. C. Barla and A. R. Bayulken; Book Review: Health Effects of Exposure to Low Levels of Ionizing Radiation BEIR V, C. R. Richmond; WASTE AND SPENT FUEL MANAGEMENT: 555 Activities Related to Waste and Spent Fuel Management, M. D. Muhlheim and E. G. Silver OPERATING EXPERIENCES: 567 Effects of Component Aging on the Westhinghouse Control Rod Drive System, K. Sullivan and W. Gunther; 577 Reactor Shutdown Experience, Compiled by J. W. Cletcher, 580 Selected Safety-Related Events, Compiled by G. A. Murphy; 582 Operating U 8 Power Reactors, Compiled by M. D. Muhlheim and E. G. Silver, RECENT DEVELOPMENTS: 596 General Administrative Activities, Compiled by M. D. Muhlheim and E. G. Silver; 610 Reports, Standards, and Safety Guides, D. S. Queener; 614 Proposed Rule Changes as of June 30, 1991; ANNOUNCEMENTS: 520 Workshop on PC PRAISE: A Probabilistic Fracture Mechanics Personal Computer Code for Nuclear Power Plant Piping Reliability Assessment; 536 Fifth Workshop on Nuclear Power Plant Containment Integrity; 624 New OECD "International Information System on Occupational Exposure (ISOE)"; 625 Harvard School of Public Health Announces Short Courses; 625 Eighth Power Plant Dynamics, Control and Testing Symposium; 626 Second Training Course on Off-Site Emergency Planning and Response for Nuclear Accidents; 618 The Authors; 622 Reviewers of Nuclear Safety, Vol 32.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Developing Smart Building Technology Modules to Enhance Workforce Preparedness: A Case for AI-Driven Academic and Professional Education

Smart building technologies are resources that improve building energy efficiency and resilience, reduce carbon emissions, and provide load flexibility to the grid. However, in both academic curricula and building professionals’ continuing education, there is a lack of systematic instruction on methods to integrate multiple energy systems including distributed energy resources (DER), smart building technologies, AI (Artificial Intelligence) tools and key concepts, components, and controls, including “Internet of Things” (IoT) devices. In today’s dynamic workforce, this major gap in smart building technology education prevents stakeholders from being able to attract talent with an understanding and preparation to adopt smart building technologies in building design and operations. A federally funded project included a partnership between Slipstream and Texas A&M University (TAMU) to develop a semester-long smart building curriculum for engineering college students with the ability to adapt the contents for workforce development of professionals in building services. The final product consists of 16 training videos adapted for building professionals and the public. The educational content and training materials cover the benefits of building energy systems, the latest sensor technologies and IoT devices, all with a focus on smart building technologies. The key drivers are on topics related to smart building controls (i.e., energy management information systems), smart building control platforms, cybersecurity, grid-interactive-efficient buildings (GEBs), smart building control methods, and occupant-centric control. Although not explicitly included the technologies nod to the need for AI driven technologies to prepare engineers and industry professionals to be future ready. This paper describes the project approach, provides outlines of the training materials, and identifies lessons learned in creating the content for this course. The authors suggest ways to scale the instruction of smart building concepts to empower the workforce to accelerate the adoption of smart building technologies and AI-based teaching and learning in higher education and building sector.

99 GENERAL AND MISCELLANEOUS↗

Multiscale Solar Water Heating (MSWH) v1.0

The main purpose of the software is to model energy use for individual and community scale solar water heating projects in California. Usage The user provides a climate zone for a project, an occupancy for each household and whether any of the occupants stay at home during the day. The software can then load a set of example California specific hourly domestic hot water end-use load profiles from a database, size and locate the systems. The user can now simulate the hourly system performance over a period of one representative year, visualize and explore the simulation results using time-series plots for temperature profiles, heat and power rates, or look at annual summaries. Similarly the user can model individual household solar water heating projects and base case conventional gas tank water heater systems, such that the results can be compared between the individual, community and base case systems. This functionality is readily available through a Jupyter notebook and a Django web framework, depending on what level of detail the user would like to access. Features - Python module to calculate solar irradiation on a tilted surface - Python module with simplified component models for Converter (solar collectors, electric resistance heater, gas burner, photovoltaic panels, heat pump), Storage (solar thermal tank, heat pump thermal tank, conventional gas tank water heater), and Distribution (distribution and solar pump, piping losses) components - Python module with preconfigured system simulation models for: base case gas tank water heaters, solar thermal water heaters (solar collector feeding a storage tank, with a tankeless gas water heater backup in a new installation cases and a base case gas tank water heater in a retrofit case) and solar electric water heaters (heat pump storage tank with an electric resistance backup) - Database with component performance parameters, California specific weather data and domestic hot water end-use load profiles - Django web framework to configure project, parametrize components and run simulation from a web browser The package contains functional and unit tests and it is structured so that it can be extended with further technologies, applications and locations.

Grahovac, Milica↗

Building America Best Practices Series - Volume 12: Builders Challenge Guide to 40% Whole-House Energy Savings in the Cold and Very Cold Climates

This best practices guide is the twelfth in a series of guides for builders produced by PNNL for the U.S. Department of Energy’s Building America program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the cold and very cold climates can build homes that have whole-house energy savings of 40% over the Building America benchmark with no added overall costs for consumers. The best practices described in this document are based on the results of research and demonstration projects conducted by Building America’s research teams. Building America brings together the nation’s leading building scientists with over 300 production builders to develop, test, and apply innovative, energy-efficient construction practices. Building America builders have found they can build homes that meet these aggressive energy-efficiency goals at no net increased costs to the homeowners. Currently, Building America homes achieve energy savings of 40% greater than the Building America benchmark home (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code). The recommendations in this document meet or exceed the requirements of the 2009 IECC and 2009 IRC and thos erequirements are highlighted in the text. This document will be distributed via the DOE Building America website: www.buildingamerica.gov.

Builders Challenge↗

The Octahedral Sheet of Metamorphic 2M 1-Phengites: a Combined EMPA And AXANES Study

Two types of metamorphic phengites are known: one is linked to high pressure and is 3T; the other is 2M{sub 1}, and its composition is linked to rock-compositional constraints. This work investigates the octahedral sheet crystal-chemical differences between the two phengite types. Seven dioctahedral micas were studied: (1) one 3T phengite from an ultrahigh-pressure metagranitoid in the Dora Maira massif, Italy (P {approx} 4.3 GPa, T {approx} 730 C); (2) five 2M{sub 1} phengites from medium-P orthogneisses in the Eastern Alps metamorphic basement, Italy (P {le} 0.7 GPa, T {approx} 500-600 C); and (3) one 2M{sub 1} ferroan muscovite from pegmatite in Antarctica (P {le} 0.2 GPa, T {approx}500 C). All micas display significant extents of celadonite substitution. In particular, the 2M{sub 1}-phengite formulae (calculated on the basis of 11 O) have 0.68 < {sup IV}Al < 0.82 atoms per formula unit (apfu); octahedral atoms are dominated by Al (1.6-1.8 apfu), with minor and variable Fe (0.20-0.35 apfu) and Mg (0.05-0.17 apfu), and very minor Ti, Mn, and Cr. Total octahedral occupancies are slightly above 2.00 apfu, i.e., there seems to be partial occupancy of the third M site. For all micas, we recorded XAFS spectra on mosaics of carefully separated flakes oriented flat on a plastic support that could be rotated so as to account for the polarization of the synchrotron radiation beam, and we processed them on the basis of the AXANES theory. Spectra show angle-dependent absorption variations for Al and Fe, which can be deconvoluted and fitted by dichroic effects. Pre-edges consistently show most Fe to be Fe{sup 3+} and little angle-dependent intensity variations. The 2M{sub 1}-ferroan muscovite from Antarctica displays the same AXANES behavior as 2M{sub 1}-phengites. By contrast, the ultrahigh-pressure 3T-phengite from Dora Maira (having {sup IV}Al = 0.42 apfu, and Al and Mg as the dominant octahedral constituents) has XAFS spectra that differ significantly. Not only is the {sup IV}Al feature strongly reduced, in agreement with the increased Si content, but also Fe XAFS spectra show one broad feature only, indicating that all Fe is Fe{sup 2+} in a fully disordered distribution with no angle-dependent variations. We conclude that this 3T-phengite is actually contaminated by exsolved Fe-bearing pyrope platelets, which cannot be resolved under SEM examination; by contrast, the 2M{sub 1}-phengites, unrelated to high-pressure, suggest Al/Fe{sup 3+} order over the M1 and (M2, M3) sites, as also does the 2M{sub 1} pegmatitic muscovite.

43 PARTICLE ACCELERATORS↗

Home energy management under realistic and uncertain conditions: A comparison of heuristic, deterministic, and stochastic control methods

We report home energy management systems (HEMS) have been shown to reduce energy bills and to provide grid services including peak demand reduction and demand flexibility. However, uncertainty in residential energy systems is a significant issue and can reduce the benefits of a HEMS to the homeowner or grid operator. Sources of uncertainty include weather forecasts, predictions of energy-related occupant activities (e.g., hot water draws), and parameter estimation for the building envelope and energy-consuming equipment. This paper tackles the problem of uncertainty by developing a framework that simulates HEMS in uncertain conditions and evaluates the performance of multiple control strategies. A linear, reduced-order residential building model for model predictive control applications is derived and compared to a full-order model. Stochastic model predictive control is shown to perform better than deterministic and heuristic methods when considering realistic forecasts with uncertainty. The framework can evaluate the performance of HEMS in real-world applications, which can help de-risk HEMS deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FRIB Fragment Pre-separator Radiation Environment Studies - Paper 133

The Facility for Rare Isotope Beams (FRIB), a project supported by the US DOE Office of Science, is under construction at Michigan State University. The project will use projectile fragmentation and induced in-flight fission of heavy ion beams at energies of 200 MeV/u and higher, and at a beam power of 400 kW, to produce rare isotope beams for nuclear physics experiments. The production of rare isotope beams during FRIB operations creates a high radiation environment in the fragment pre-separator area where the production target is located. Adequate shielding must be placed around the beam line components to ensure personnel protection during and after the operations. Detailed radiation transport studies in the fragment pre-separator area are necessary and have been performed for proper shielding choices. We calculate neutron and photon fluxes and their energy distributions, and evaluate prompt and residual dose equivalent rates in the hot cell and prompt dose equivalent rates in the MSM gallery outside of the cell where people might be present during normal operations. We also calculate dose equivalent rates in the MSM gallery when the activated components are placed in front of the MSM lead glass window on the hot cell side. We show that the resulting dose equivalent rates are conservative even for the most neutron-rich energetic beams. These calculations guide local shielding design and support operations. (authors)

43 PARTICLE ACCELERATORS↗

Informative Path Planning for Mapping Radiation

This project involves making measurements of contaminated areas using portable radiation detectors and small robots. Tasks involve operating detectors and small robots, combining data acquisition for the two systems, and automating the systems. The end result is a radiation map of contamination areas. Localization of radioactive sources and mapping of contamination distribution is essential when responding to emergencies, or when dealing with cleanup efforts. Radiation maps are used for situational awareness and for establishing a safe perimeter. However, it may be hazardous or impossible for humans to safely enter the site and survey the area. Informative Path Planning (IPP) is used to design a path for a robotic sensor platform to gather the most information about the radiation distribution while operating under the set of constraints given by the dynamics of the robot and other requirements such as minimizing the overall mission time. The key challenge for IPP is the tight coupling in multiple layers of decisions: Selection of locations to visit; Allocation of sensors to those locations; Processing of information gathered. Given a robot equipped with a basic gamma detector and Lidar sensor, how can we efficiently explore an unknown environment in such a way that we can satisfy the robot's constraints while simultaneously maximizing the accuracy of the map and minimizing the total runtime? This work presents a systematic procedure for IPP and environmental mapping that: Selects the best locations at which to sample; Finds the best path for robots; Estimates the measurement value at unknown locations using a Gaussian Process regression framework. Given a set of points where radiation measurements were taken, we are utilizing a Gaussian Process Regression with a Matern kernel to reconstruct the shape of the underlying ground truth. Mapping is done via the Robot Operating System's OpenSlam Gmapping package, which creates a 2D occupancy grid map. Simulated trials were run with a radiation source placed at random locations, and allowing the robot to select and move towards 20 samples at separate locations, as well as sampling along the path while moving. The simulated sensor model assumed an efficiency of 0.3, collection time of 1 second. Various weighting schemes were tested and compared. Quantitative evaluations often favored exploitation-heavy weighting schemes where μ was emphasized, with the Root Mean Squared Error (RMSE) quickly tending towards 2, whereas qualitative comparisons would favor exploration-biased schemes with greater weight on σ. The difference comes from operators often favoring knowing the general location of a source, rather than the exact properties of a source. Weighting of the path-length π often reduced the quality of the regression as less exploration occurred, however this may be deemed a worthwhile trade-off under certain circumstances, such as with sensitive robots. Successfully developed a methodology for informative path-planning for a robot to efficiently gather information and create a map of radiation. In the future, we would like to focus on: Hardware trials with integration of the robot platform and the IPP software; More refined sensor and environmental modeling; Multiple robot platforms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Biokinetic models for radiocesium and its progeny

Over the next few years the International Commission on Radiological Protection (ICRP) will publish a series of reports containing updated biokinetic and dosimetric models and dose coefficients for occupational intake of radionuclides. The biokinetic modeling scheme continues a trend in modern ICRP reports toward physiologically realistic descriptions of the time-dependent behavior of absorbed radionuclides and ingrowing chain members. This paper proposes systemic biokinetic models for cesium isotopes and their chain members for use in these ICRP reports and examines dosimetric implications of the proposed models. Comparisons of A = tissue dose per unit input to blood based on current ICRP models for workers (ICRP Publication 68, 1994) with B = corresponding values based on the proposed biokinetic models (but using dosimetry models of Publication 68) yields the following ranges of ratios B:A for tissues addressed in current ICRP documents: 0.5-25 for 130Cs (T1/2 = 29.2 min), 0.6-9.5 for 134mCs (2.9 h), 0.8-2.2 for 129Cs (32.1 h), 0.7-1.7 for 131Cs (9.69 d), 0.8-1.3 for 136Cs (13.2 d), 0.7-1.1 for 134Cs (2.06 y), 0.5-1.9 for 137Cs (30.2 y), and 0.2-3.7 for 135Cs (2.3x106 y). The large differences in estimated tissue dose for some tissues and cesium isotopes, particularly short-lived isotopes, result mainly from differences in model predictions of the time-dependent distributions of cesium in the body. For example, the proposed and current ICRP models for cesium predict peak kidney contents of ~22% and ~0.4%, respectively, following intravenous injection of stable cesium. Based on the proposed models for cesium and its progeny, the only dosimetrically significant chain members of cesium isotopes are 137mBa, which represents 32-85% of the estimated tissue doses from injected 137Cs, and 134Cs, which represents 4-53% of the estimated tissue doses from injected 134mCs.

cesium biokinetics progeny dosimetry radiation pro↗

Correction of confidence intervals in excess relative risk models using Monte Carlo dosimetry systems with shared errors

Introduction: Measurement errors are ubiquitous in epidemiological studies, especially for doses arising from environmental and occupational exposures, which are difficult to assess. Correction methods for independent measurement errors, have been comprehensively described elsewhere, including regression calibration, simulation extrapolation (SIMEX), etc. However, when exposure estimates are constructed using complicated physical and biological models, uncertainties in the dosimetry system can become very complex. In such systems, uncertainties in some parameters may affect a large group of study participants simultaneously, and hence are “shared” as opposed to independent dosimetric uncertainties. Representing the structure of the uncertainty in the dosimetry by providing multiple realizations of possible dose has been described for several studies. The goal of this paper is to implement, and explore the properties of, a generalized estimating equation-based approach to shared uncertainties based on principles described in an earlier paper. Methods: The effects of shared and unshared dosimetry error on parameter estimates and confidence intervals in a generalized excess relative risk model are examined. A post-hoc correction method is implemented that constructs corrected confidence intervals based on an underlying variance structure described in an earlier paper. In this correction method it is assumed that the estimated slope parameter in a linear excess relative risk model is distributed as a mixture of normal and lognormal components. A simulation study of the behavior of this correction was developed based on multiple realizations provided by the Monte Carlo dosimetry system used for the plutonium exposures in the Mayak Worker Cohort and a risk model with close similarity to that used in analyses of lung cancer data in that cohort. Results: In the simulation study we found that shared dose errors severely degraded the coverage probabilities of confidence limits for the slope parameter in the linear excess relative risk model relating uncertain exposure to lung cancer risk. Using our correction method to adjust the confidence intervals provided much improved coverage probabilities for this parameter. A smaller amount of degradation in confidence interval coverage for other parameters (e.g. those in the baseline and dose modification terms) was noted, and the proposed correction method also improved coverage for these parameters as well. Discussion: Compared to other recently described methods our proposed correction method relies on relatively familiar software to fit dose response models. The basic modeling philosophy described here first uses existing Poisson regression methods to estimate parameters in the excess relative risk model; in this first stage mean dose (computed from the multiple realizations) is used as the independent variable in the regression. Once the model is fit we then correct (widen) the standard errors for all parameters using the proposed correction method. The simulation studies indicate that the methods described here are an important contribution to the available tools for dealing with shared measurement errors in complex risk analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

Building America Best Practices Series - Volume 15: 40% Whole-House Energy Savings in the Hot-Humid Climate

This best practices guide is the 15th in a series of guides for builders produced by PNNL for the U.S. Department of Energy’s Building America program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the hot-humid climate can build homes that have whole-house energy savings of 40% over the Building America benchmark with no added overall costs for consumers. The best practices described in this document are based on the results of research and demonstration projects conducted by Building America’s research teams. Building America brings together the nation’s leading building scientists with over 300 production builders to develop, test, and apply innovative, energy-efficient construction practices. Building America builders have found they can build homes that meet these aggressive energy-efficiency goals at no net increased costs to the homeowners. Currently, Building America homes achieve energy savings of 40% greater than the Building America benchmark home (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code). The recommendations in this document meet or exceed the requirements of the 2009 IECC and 2009 IRC and those requirements are highlighted in the text. Requirements of the 2012 IECC and 2012 IRC are also noted in text and tables throughout the guide. This document will be distributed via the DOE Building America website: www.buildingamerica.gov.

Building America↗

Building America Best Practices Series - Volume 16: 40% Whole-House Energy Savings in the Mixed-Humid Climate

This best practices guide is the 16th in a series of guides for builders produced by PNNL for the U.S. Department of Energy’s Building America program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the mixed-humid climate can build homes that have whole-house energy savings of 40% over the Building America benchmark with no added overall costs for consumers. The best practices described in this document are based on the results of research and demonstration projects conducted by Building America’s research teams. Building America brings together the nation’s leading building scientists with over 300 production builders to develop, test, and apply innovative, energy-efficient construction practices. Building America builders have found they can build homes that meet these aggressive energy-efficiency goals at no net increased costs to the homeowners. Currently, Building America homes achieve energy savings of 40% greater than the Building America benchmark home (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code). The recommendations in this document meet or exceed the requirements of the 2009 IECC and 2009 IRC and those requirements are highlighted in the text. Requirements of the 2012 IECC and 2012 IRC are also noted in text and tables throughout the guide. This document will be distributed via the DOE Building America website: www.buildingamerica.gov.

Building America↗

Mechanisms of Low Dose Radiation-induced T helper Cell Function

Exposure to radiation above levels normally encountered on Earth can occur during wartime, accidents such as those at Three Mile Island and Chernobyl, and detonation of “dirty bombs” by terrorists. Relatively high levels of radiation exposure can also occur in certain occupations (low-level waste sites, nuclear power plants, nuclear medicine facilities, airline industry, and space agencies). Depression or dysfunction of the highly radiosensitive cells of the immune system can lead to serious consequences, including increased risk for infections, cancer, hypersensitivity reactions, poor wound healing, and other pathologies. The focus of this research was on the T helper (Th) subset of lymphocytes that secrete cytokines (proteins), and thus control many actions and interactions of other cell types that make up what is collectively known as the immune system. The Department of Energy (DOE) Low Dose Radiation Program is concerned with mechanisms altered by exposure to high energy photons (x- and gamma-rays), protons and electrons. This study compared, for the first time, the low-dose effects of two of these radiation forms, photons and protons, on the response of Th cells, as well as other cell types with which they communicate. The research provided insights regarding gene expression patterns and capacity to secrete potent immunostimulatory and immunosuppressive cytokines, some of which are implicated in pathophysiological processes. Furthermore, the photon versus proton comparison was important not only to healthy individuals who may be exposed, but also to patients undergoing radiotherapy, since many medical centers in the United States, as well as worldwide, are now building proton accelerators. The overall hypothesis of this study was that whole-body exposure to low-dose photons (gamma-rays) will alter CD4+ Th cell function. We further proposed that exposure to low-dose proton radiation will induce a different pattern of gene and functional changes compared to photons. Over the course of this research, tissues other than spleens were archived and with funding obtained from other sources, including the Department of Radiation Medicine at the Loma Linda University Medical Center, some additional assays were performed. Furthermore, groups of additional mice were included that were pre-exposed to low-dose photons before irradiating with acute photons, protons, and simulated solar particle event (SPE) protons. Hence, the original support together with the additional funding for our research led to generation of much valuable information that was originally not anticipated. Some of the data has already resulted in published articles, manuscripts in review, and a number of presentations at scientific conferences and workshops. Difficulties in reliable and reproducible quantification of secreted cytokines using multi-plex technology delayed completion of this study for a period of time. However, final analyses of the remaining data are currently being performed and should result in additional publications and presentations in the near future. Some of the most notable conclusions, thus far, are briefly summarized below: - Distribution of leukocytes were dependent upon cell type, radiation quality, body compartment analyzed, and time after exposure. Low-dose protons tended to have less effect on numbers of major leukocyte populations and T cell subsets compared to low-dose photons. - The patterns of gene and cytokine expression in CD4+ T cells after protracted low-dose irradiation were significantly modified and highly dependent upon the total dose and time after exposure. - Patterns of gene and cytokine expression differed substantially among groups exposed to low-dose photons versus low-dose protons; differences were also noted among groups exposed to much higher doses of photons, protons, and simulated SPE protons. - Some measurements indicated that exposure to low-dose photon radiation, especially 0.01 Gy, significantly “normalized” at least some adverse effects of simulated SPE protons, thereby suggesting that this low level of radiation may induce protective mechanisms against a relatively large radiation event. - Analysis of signal transduction pathways in CD4+ T cells showed that whole-body priming with 0.01 Gy photons before exposure to simulated SPE protons significantly increased expression of p38MAPK and NF-kappaB, while JNK expression was decreased. Overall, it appears that the p38MAPK signaling pathway may be most important in inducing a radioprotective response.

43 PARTICLE ACCELERATORS↗

Passive Room-to-Room Air Transfer, Fresno, California (Fact Sheet)

Field testing was performed in a retrofit unoccupied test house in Fresno, California. Three air-based heating, ventilation, and air conditioning (HVAC) distribution systems - a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms - were evaluated during heating, cooling, and midseason conditions. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics (CFD) modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low dose radiation risks for women surviving the a-bombs in Japan: generalized additive model

Background: Analyses of cancer mortality and incidence in Japanese A-bomb survivors have been used to estimate radiation risks, which are generally higher for women. Relative Risk (RR) is usually modelled as a linear function of dose. Extrapolation from data including high doses predicts small risks at low doses. Generalized Additive Models (GAMs) are flexible methods for modelling non-linear behaviour. Methods: GAMs are applied to cancer incidence in female low dose subcohorts, using anonymous public data for the 1958 – 1998 Life Span Study, to test for linearity, explore interactions, adjust for the skewed dose distribution, examine significance below 100 mGy, and estimate risks at 10 mGy. Results: For all solid cancer incidence, RR estimated from 0 – 100 mGy and 0 – 20 mGy subcohorts is significantly raised. The response tapers above 150 mGy. At low doses, RR increases with age-at-exposure and decreases with time-since-exposure, the preferred covariate. Using the empirical cumulative distribution of dose improves model fit, and capacity to detect non-linear responses. RR is elevated over wide ranges of covariate values. Results are stable under simulation, or when removing exceptional data cells, or adjusting neutron RBE. Estimates of Excess RR at 10 mGy using the cumulative dose distribution are 10 – 45 times higher than extrapolations from a linear model fitted to the full cohort. Below 100 mGy, quasipoisson models find significant effects for all solid, squamous, uterus, corpus, and thyroid cancers, and for respiratory cancers when age-at-exposure > 35 yrs. Results for the thyroid are compatible with studies of children treated for tinea capitis, and Chernobyl survivors. Results for the uterus are compatible with studies of UK nuclear workers and the Techa River cohort. Conclusion: Non-linear models find large, significant cancer risks for Japanese women exposed to low dose radiation from the atomic bombings. The risks should be reflected in protection standards.

60 APPLIED LIFE SCIENCES↗

A Stochastic Multi-Criteria Decision-Making Algorithm for Dynamic Load Prioritization in Grid-Interactive Efficient Buildings

Increasing deployment of advanced sensing, controls, and communication infrastructure enables buildings to provide services to the power grid, leading to the concept of grid-interactive efficient buildings. Since occupant activities and preferences primarily drive the availability and operational flexibility of building devices, there is a critical need to develop occupant-centric approaches that prioritize devices for providing grid services, while maintaining the desired end-use quality of service. In this paper, we present a decision-making framework that facilitates a building owner/operator to effectively prioritize loads for curtailment service under uncertainties, while minimizing any adverse impact on the occupants. The proposed framework uses a stochastic (Markov) model to represent the probabilistic behavior of device usage from power consumption data, and a load prioritization algorithm that dynamically ranks building loads using a stochastic multi-criteria decision-making algorithm. The proposed load prioritization framework is illustrated via numerical simulations in a residential building use-case, including plug-loads, air-conditioners, and plug-in electric vehicle chargers, in the context of load curtailment as a grid service. Suitable metrics are proposed to evaluate the closed-loop performance of the proposed prioritization algorithm under various scenarios and design choices. Scalability of the proposed algorithm is established via computational analysis, while time-series plots are used for intuitive explanation of the ranking choices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Model-Free Transactive Control of Building Loads to Support Grid Services

Residential buildings consume 4.4 quads of electricity annually, approximately 37% of the total electricity consumption in the United States. This represents a vast resource that can be used for demand management and other ancillary services. This project aims to develop a robust, scalable hierarchical transactional control mechanism incorporating elements of model-free control (MFC) and game theory to harness buildings to provide ancillary services to the grid. This approach is being taken to address the challenges of incorporating traditional transactional control schemes into existing buildings. The challenges include small individual building sizes requiring aggregation of many buildings, unpredictable energy usage that makes model identification difficult, and satisfying the sensitive occupant comfort constraints. In the proposed approach, by separating the control mechanism into two layers above and below the load aggregator, MFC can be used below the aggregator to modulate flexible building loads in response to pricing signals with guaranteed performance. This allows the burden of identifying an accurate model of the system to be shifted to the above-aggregator layer, where fluctuations in individual building usage have less impact on predicted building system behavior. Game theory concepts can then be used to determine pricing curves and control signals among regional aggregators. Managing this control in a game-theoretic approach will allow us to build in financial incentives that increase customer engagement. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable on small, embedded devices. In a broader sense, developing a strategy capable of effectively incorporating residential and small commercial buildings will allow greater throughput of existing and emerging grid services in addition to future transactive energy grid management methods. Using MFC within a hierarchical control architecture will allow the shifting of existing forecasting challenges to an aggregate level, where dynamics are slower and more predictable. This will enable a smooth interface between the grid services requests of utilities and the reliable control required by participating buildings. MFC, which supports distributed control architecture, permits a scalable solution that can be deployed to neighborhood-size systems as well as individual buildings. This project focuses on three objectives: (1) developing the mathematical framework, algorithm toolkit, and software toolset of the two-layer transactive control testbed; (2) developing a scalable solution for application over many residential and small-size commercial buildings with sparse distributed communication; and (3) field testing and implementation on hardware of the control strategies developed in the previous two objectives. The research and development activities are focused and designed to be impactful within the relevant 2025 targets timeframe. An open-source control framework for exploiting variability and dispatchability of building loads will be delivered as the outcome of the project. This capability enables greater participation of loads in electricity markets and ancillary services that are both useful for the utility and financially beneficial for building owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗