Measurement of Helium and Xenon Knudsen permeability in graphite IG-11

Here, understanding the flow and diffusion (transport) of gases through nuclear graphite is of interest in both the prismatic and pebble bed high-temperature gas reactors (HTGRs), for normal operation and under accident conditions, for example, as related to graphite oxidation. Both the laminar and turbulent gaseous transport are of interest. It has also been noted that nuclear graphite can have pore sizes that can possibly lead to non-continuum transport, as the pore size can be comparable to the gaseous mean free path. We report measurements and analyzes of experiments performed with IG-11 graphite in the pressure range of 10 Pa to 14,700 Pa, 293 K, using Helium, and research grade xenon (99.999%), respectively. These values are in fair agreement with those reported for different graphites and gases by other investigators, but are also higher by six orders of magnitude than those reported for Kr permeability in a developmental very low permeability graphite-HXT-90. Our measured ratio of the Helium and Xenon permeabilities is about 4, different from $\sqrt{\frac{m_{Xe}}{m_{He}}}$ ≈ 5.72 that corresponds to diffuse reflection at the graphite surface for both gases. Simple analysis indicates that the two gases have slightly different accommodation coefficients (about 25%) with the graphite surface. However, there could also be other reasons, such as experimental uncertainties or the need for a more detailed analysis.

36 MATERIALS SCIENCE↗

Evolution of Microstructure and Surface Characteristics of FeCrAl alloys when Subjected to Flow Boiling Testing

FeCrAl alloys are candidate materials for manufacturing accident-tolerant fuel (ATF) cladding intended for light water reactors to increase fuel reliability and safety during design-basis and beyond-design-basis accident scenarios. The evolution of the materials' surface characteristics, microstructure, and mechanical properties when exposed to the Critical Heat Flux (CHF) in flow boiling testing is crucial for safety analysis while providing insights into their thermal-hydraulic performance in nuclear reactors. After CHF, the surface chemistry of two FeCrAl alloys, APMT and C26M, was studied to understand their evolution at the early stage of high-temperature excursions in short time periods. The results indicated a thin layer composed of oxides and hydroxides of Al, Cr, and Fe with varying proportions at different depths in the layer, as indicated by X-ray photoelectron spectroscopy (XPS) and depth profiling. The cross-sections prepared by focused ion beam (FIB) revealed the growth of an oxide layer, in the range of 90-180 nm thick, on the alloys' surfaces. The evolution of the materials' surface chemistry also led to a noticeable post CHF excursion increase in their wettability, with a slight increase in roughness. Further, the investigation of the materials' mechanical properties indicated a modest increase in hardness by 10-15% as well as an increase in their yield strength, as evidenced by the microindentation and ring compression tests conducted before and after CHF testing. Scanning electron Microscopy (SEM) and X-ray diffraction (XRD) were used to investigate microstructural features of the materials and their changes after CHF treatment.

36 MATERIALS SCIENCE↗

Mechanistic transition of stainless steel 304L corrosion in MgCl 2 phase change material under thermal cycling

Magnesium chloride (MgCl 2 )-based molten salt phase change materials (PCMs) are promising candidates for thermal energy storage (TES) owing to their advantageous thermophysical properties, however, their high corrosivity in the molten state limits material compatibility. In this study, the corrosion behavior of 304?L stainless steel (SS304L) exposed to MgCl2 PCM was investigated as a function of thermal cycling (up to 9000 cycles) relevant to PCM-based TES systems. Microstructural changes and elemental redistribution at the alloy-salt interface under thermal cycling conditions were characterized using synchrotron-based X-ray fluorescence (XRF) and scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM-EDS). Results show that corrosion is governed by selective Cr-dissolution and elemental diffusion near the interface and grain boundaries. A clear transition in the dominant corrosion mechanism is observed with increasing thermal cycles. Surface corrosion is the dominant mechanism up to 1000 cycles, whereas intergranular corrosion becomes the primary degradation mode beyond 2000 cycles. These mechanistic changes are interpreted in terms of evolving interfacial chemistry, microstructure and the diffusion-driven redistribution of alloying elements.

36 MATERIALS SCIENCE↗

Volume I. Introduction to DUNE

The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. This TDR is intended to justify the technical choices for the far detector that flow down from the high-level physics goals through requirements at all levels of the Project. Volume I contains an executive summary that introduces the DUNE science program, the far detector and the strategy for its modular designs, and the organization and management of the Project. The remainder of Volume I provides more detail on the science program that drives the choice of detector technologies and on the technologies themselves. It also introduces the designs for the DUNE near detector and the DUNE computing model, for which DUNE is planning design reports. Volume II of this TDR describes DUNE's physics program in detail. Volume III describes the technical coordination required for the far detector design, construction, installation, and integration, and its organizational structure. Volume IV describes the single-phase far detector technology. A planned Volume V will describe the dual-phase technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraints on lepton number violation with the 2 tonne · year CUORE dataset

Matter-antimatter asymmetry underlines the incompleteness of the current understanding of particle physics. Neutrinoless double-beta decay (0νββ) may help explain this asymmetry while unveiling the Majorana nature of the neutrino. The CUORE (Cryogenic Underground Observatory for Rare Events) experiment searches for 0νββ of 130 Te using a tonne-scale cryogenic calorimeter operated at milli-kelvin temperatures. We report no evidence of 0νββ and place a lower limit on the half-life of T 1/2 > 3.5 × 10 25 years (90% credibility interval) with over 2 tonne·years of TeO 2 exposure. Finally, the tools and techniques developed for this result and the 5-year stable operation of nearly 1000 detectors demonstrate crucial infrastructure for future-generation experiments capable of searching for 0νββ across multiple isotopes.

Adams, D. Q. [Department of Physics and Astronomy,↗

Volume III. DUNE far detector technical coordination

The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume III of this TDR describes how the activities required to design, construct, fabricate, install, and commission the DUNE far detector modules are organized and managed. This volume details the organizational structures that will carry out and/or oversee the planned far detector activities safely, successfully, on time, and on budget. It presents overviews of the facilities, supporting infrastructure, and detectors for context, and it outlines the project-related functions and methodologies used by the DUNE technical coordination organization, focusing on the areas of integration engineering, technical reviews, quality assurance and control, and safety oversight. Because of its more advanced stage of development, functional examples presented in this volume focus primarily on the single-phase (SP) detector module.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Volume IV. The DUNE far detector single-phase technology

The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. Central to achieving DUNE's physics program is a far detector that combines the many tens-of-kiloton fiducial mass necessary for rare event searches with sub-centimeter spatial resolution in its ability to image those events, allowing identification of the physics signatures among the numerous backgrounds. In the single-phase liquid argon time-projection chamber (LArTPC) technology, ionization charges drift horizontally in the liquid argon under the influence of an electric field towards a vertical anode, where they are read out with fine granularity. A photon detection system supplements the TPC, directly enhancing physics capabilities for all three DUNE physics drivers and opening up prospects for further physics explorations. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume IV presents an overview of the basic operating principles of a single-phase LArTPC, followed by a description of the DUNE implementation. Each of the subsystems is described in detail, connecting the high-level design requirements and decisions to the overriding physics goals of DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of a surrogate for plutonium electrorefining

Conducting research experiments on plutonium electrorefining is difficult due to the significant hazards and regulations associated with nuclear materials. Finding a surrogate for plutonium electrorefining studies would enable more fundamental research to be conducted. Potential surrogates were first identified by determining the physical properties required to conduct electrorefining at the same conditions commonly used in plutonium electrorefining, a molten metal and molten CaCl 2 at 1123 K. Ce-CeCl 3 , In-InCl 3 , and Pb-PbCl 2 were the only potential surrogates identified using these constraints. Sn-SnCl 2 was also tested at these same conditions. More potential surrogates were identified by changing the matrix salt and operating temperature. This expanded the potential surrogate list to also include Zn-ZnCl 2 , Sn-SnCl 2 , and Bi-BiCl 3 . Zn-ZnCl 2 was used with the LiCl-CaCl 2 (65:35 mol%) eutectic at 773 K. Sn-SnCl2 and Bi-BiCl 3 were used with the LiCl-KCl-CaCl 2 (50.5:44.2:5.3 mol%) eutectic at 673–773 K. Ce electrorefining in molten CaCl 2 resulted in a difficult to separate colloid mixture of Ce, Ca and Cl. Electrorefining rates for In in molten CaCl 2 were too slow due to InCl 3 volatilizing out of the molten salt. Only trace amounts of SnCl 2 was retained in the CaCl 2 at 1123 K resulting in impractical electrorefining rates. Zn metal product was successfully collected in the LiCl-CaCl 2 eutectic molten salt, but the metal obtained did not coalesce into one piece. Sn and Bi were successfully electrorefined in the LiCl-KCl-CaCl 2 eutectic molten salt and coalesced into product rings with high yields and coulombic efficiencies. Finally, while a surrogate could not be identified using the same conditions as plutonium electrorefining, two possible surrogates, Sn-SnCl 2 and Bi-BiCl 3 , were found that could imitate the physical configuration (i.e., molten salt on top of molten metal) of plutonium electrorefining at a reduced temperature using the eutectic LiCl-KCl-CaCl 2 salt at 673–773 K in place of CaCl 2 at 1123 K.

36 MATERIALS SCIENCE↗

Radioisotope dating of nuclear materials using cryogenic decay energy spectrometry

Cryogenic decay energy spectrometry provides high energy resolution and enables absolute decay counting, offering an alternative measurement technique for radiochronometry. A cryogenic decay energy spectrometry experiment was conducted using a magnetic microcalorimeter to determine the age of a plutonium sample. The energy resolution was measured at 0.05% from 5 to 6 MeV. The time since sample purification was determined using the measured concentration ratio of the 241 Am/ 241 Pu radiochronometer. Sample age estimates based on 241 Pu alpha-decay and beta-decay counts, along with 241 Am decay counts, align with the expected sample age within expanded uncertainty (k = 2), supporting the accuracy of cryogenic decay energy spectrometry as a radiochronometric method.

and nuclear chemistry↗

Design and synthesis of astatinated benzothiazole compounds for their potential use in Targeted Alpha Therapy (TAT) strategies to treat Alzheimer's disease-associated amyloid plaques

Alzheimer's disease (AD) is a terminal neurodegenerative disease characterized by the buildup of amyloid fibrils, amorphous aggregates and tauopathies. Several treatment modalities, which rely on various biological processes to reduce disease burden, have been largely ineffective at treating Alzheimer's disease. Targeted alpha therapy (TAT) has demonstrated positive results in the treatment of cancer. Benzothiazole derivatives have been successfully shown to target these plaques and are used in several imaging applications. One such derivative, Flutemetamol (Vizamyl TM ) is an FDA approved diagnostic tool for PET imaging of AD-associated plaques. We report the radiolabeling of benzothiazole derivatives with 211 At, a 7.2 h alpha emitting radionuclide, using a copper catalyzed reaction with a boronic acid precursor molecule. In conclusion, our final compound [ 211 At]3'-At-PIB-OMe had a radiochemical yield of 55% and was found to be stable for at least 3 h in phosphate buffered saline.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Discrimination of phosgene from cyanogen chloride in recovered chemical munitions using tagged neutron interrogation with high-resolution gamma-ray spectroscopy

The Associated Particle technique has recently been utilized with a germanium-based high-resolution $\gamma$-ray spectrometer and assessed for its capability to improve field identification of recovered chemical warfare (CW) materiel through prompt gamma-ray neutron activation analysis (PGNAA) measurements. An accurate chemical identification is necessary for the safe handling, destruction, and disposal of such hazardous items. A particularly challenging pair of CW agents commonly found in recovered munitions are phosgene (CG) and cyanogen chloride (CK), which have two of three elements in common, i.e. chlorine and carbon, but differ in the third being either oxygen or nitrogen. The detection of both latter elements is complicated by high oxygen concentration in the field environment which interferes with the small signal produced from the chemical agents. The matter is further complicated by the precautionary field practice of overpacking recovered munitions with vermiculite in larger steel multiple round containers (MRCs), which places additional oxygen-rich material around the munition while further attenuating an already weak signal emitted from the munition center. Here, this work reports quantitative results from realistic field measurements of CG and CK simulants in mock 4.2-inch mortar rounds overpacked with vermiculite in a large MRC. Results obtained with the AP technique are compared to those obtained with the traditional PGNAA approach for both overpacked- and bare-munition measurements. The AP technique is shown to provide a much more confident discrimination between the two chemicals, particularly for the more challenging field-relevant overpacked measurements, where a significant gain in sensitivity to all the key elements chlorine, carbon, nitrogen and oxygen is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the competition between Tl + and Ce 3+ scintillation in Tl2LiYCl6:Ce, an elpasolite scintillator

Li-containing elpasolite scintillators are currently investigated for their ability to detect both thermal neutrons and gamma photons with a single inorganic crystal. The scintillation is typically triggered by using an activator such as Ce. However, when Tl, also a luminescent ion, is present in the matrix, competition between the two centers Tl and Ce can occur. In this study, we are using Ce doped Tl 2 LiYCl 6 to investigate this competition. To this end, the Ce (which substitutes Y) concentration is varied from 0 to 1 in the Tl 2 LiY 1-x CexCl 6 composition. In the low concentration range in which Ce remains a dopant, the photo- and radioluminescence spectra show that the scintillation of Tl 2 LiYCl 6 :Ce is mostly dominated by recombination on intrinsic luminescent centers. For cerium concentrations higher than x = 0.02, very different emissions can be easily distinguished from the photo- and radioluminescence of undoped and low Ce doped Tl 2 LiYCl 6 crystals. These emissions are attributed to the formation of a second phase Tl 2 CeCl 5 , identified by X-ray diffraction. We conclude that the intrinsic luminescence related to Tl dominates the scintillation in the range of concentration for which Ce does substitute on the Y-site.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 forward electromagnetic calorimeter

The CLAS12 Forward Detector includes six independent lead-scintillator electromagnetic sampling calorimeters to provide the primary electron trigger and extend the CLAS12 detection capability to photons and neutrons. Each calorimeter package consists of two modules, the legacy Electromagnetic Calorimeter (EC) previously used in the CLAS detector, and a new pre-shower calorimeter (PCAL) located in front of the EC to extend the total detector radiation length, in order to fully absorb the electromagnetic showers induced by electrons with energies up to 12 GeV. Both calorimeters use a novel triangular hodoscope geometry with stereo readout. The PCAL uses an upgraded design to provide the high spatial resolution necessary for reconstructing π 0 and η decays, and neutrons with high efficiency. Here, this paper treats the design, construction, and calibration of the PCAL and the preliminary combined performance of both detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 Forward Tagger

This document presents the technical layout and the performance of the CLAS12 Forward Tagger (FT). The FT, composed of an electromagnetic calorimeter based on PbWO$_4$ crystals (FT-Cal), a scintillation hodoscope (FT-Hodo), and several layers of Micromegas trackers (FT-Trk), has been designed to detect electrons and photons scattered at polar angles from 2$^\circ$ to 5$^\circ$ and to meet the physics goals of the hadron spectroscopy program and other experiments running with the CLAS12 spectrometer in Hall B.