Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Noise characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Large format SEC orthicon integrating television sensor for LST

The Large Space Telescope will employ a 70 mm format SEC type television camera tube as the data sensor for one or more scientific instruments. The characteristics of this tube are described. The current performance is characterized by an MTF of 50% at 20 line pairs per mm and a signal-to-noise ratio that is about one-half the theoretical based on the square root of the number of photoelectrons. The paper presents some astronomical results and the status of the environmental testing of the tube. Other topics such as radiation sensitivity and thermal design are also discussed.

Lowrance, J. L.↗

Transonic rotor noise: Theoretical and experimental comparisons

Two complementary methods of describing the high speed rotor noise problem are discussed. The first method uses the second order transonic potential equation to define and characterize the nature of the aerodynamic and acoustic fields and to explain the appearance of radiating shock waves. The second employs the Ffowcs Williams and Hawkings equation to successfully calculate the acoustic far field. Good agreement between theoretical and experimental waveforms is shown for transonic hover tip Mach numbers from 0.8 to 0.9.

Schmitz, F. H.↗

InGaAsSb Detectors' Characterization for 2-Micron CO2 Lidar/DIAL Applications

Recent interest in monitoring atmospheric CO2 focuses attention on infrared remote sensing using the 2-micron lidar/differential absorption lidar (DIAL) technique. Quantum detectors are critical components in this technique, and many research efforts concentrate on developing such devices for the 2-micron wavelength. Characterization results of InGaAsSb quantum detectors for the 2-micron wavelength range are presented, including experimental setup and procedure. Detectors are prototype devices manufactured by using separate absorption and multiplication (SAM) structures. Characterization experiments include V-I measurements, spectral response and its variation with bias voltage and temperature, noise measurements, noise-equivalent-power (NEP) and detectivity calculations, and signal-to-noise ratio (SNR) estimation. A slight increase in the output signal occurred with increased bias voltage and was associated with a noise level increase. Cooling down the detectors reduces noise and shifts the cutoff wavelength to shorter values. Further improvement in the design and manufacturing process, by increasing the device gain and lowering its noise level, is necessary to meet the required CO2 lidar/DIAL specifications.

Refaat, Tamer F.↗

InGaAsSb Detectors Characterization for 2-Micron CO2 Lidar/DIAL Applications

Recent interest in monitoring atmospheric CO2 focuses attention on infrared remote sensing using the 2-micron lidar/differential absorption lidar (DIAL) technique. Quantum detectors are critical components in this technique, and many research efforts concentrate on developing such devices for the 2-micron wavelength. Characterization results of InGaAsSb quantum detectors for the 2-micron wavelength range are presented, including experimental setup and procedure. Detectors are prototype devices manufactured by using separate absorption and multiplication (SAM) structures. Characterization experiments include V-I measurements, spectral response and its variation with bias voltage and temperature, noise measurements, noise-equivalent-power (NEP) and detectivity calculations, and signal-to-noise ratio (SNR) estimation. A slight increase in the output signal occurred with increased bias voltage and was associated with a noise level increase. Cooling down the detectors reduces noise and shifts the cutoff wavelength to shorter values. Further improvement in the design and manufacturing process, by increasing the device gain and lowering its noise level, is necessary to meet the required CO2 lidar/DIAL specifications.

Refaat, Tamer F.↗

MODIS On-Orbit Thermal Emissive Bands Lifetime Performance

MODerate resolution Imaging Spectroradiometer (MODIS), a leading heritage sensor in the fleet of Earth Observing System for the National Aeronautics and Space Administration (NASA) is in space orbit on two spacecrafts. They are the Terra (T) and Aqua (A) platforms. Both instruments have successfully continued to operate beyond the 6 year design life time, with the T-MODIS currently functional beyond 15 years and the A-MODIS operating beyond 13 years respectively. The MODIS sensor characteristics include a spectral coverage from 0.41 micron 14.4 micron, of which wavelengths ranging from 3.7 micron 14. 4 micron cover the thermal infrared region also referred to as the Thermal Emissive Bands (TEBs). The TEBs is calibrated using a v-grooved BlackBody (BB) whose temperature measurements are traceable to the National Institute of Standards and Technology temperature scales. The TEBs calibration based on the onboard BB is extremely important for its high radiometric fidelity. In this paper, we provide a complete characterization of the lifetime instrument performance of both MODIS instruments in terms of the sensor gain, the Noise Equivalent difference Temperature, key instrument telemetry such as the BB lifetime trends, the instrument temperature trends, the Cold Focal Plane telemetry and finally, the total assessed calibration uncertainty of the TEBs.

Madhavan, Sriharsha↗

Parallel Plate Capacitor Aluminum KIDs for Future Far-Infrared Space-Based Observatories

Future space-based far-infrared astrophysical observatories will require exquisitely sensitive detectors consistent with the low optical backgrounds. The PRobe far-Infrared Mission for Astrophysics (PRIMA) will deploy arrays of thousands of superconducting kinetic inductance detectors (KIDs) sensitive to radiation between 25 and 265 μm. Here, we present laboratory characterization of prototype, 25 – 80 μm wavelength, low-volume, aluminum KIDs designed for the low-background environment expected with PRIMA. A compact parallel plate capacitor is used to minimize the detector footprint and suppress TLS noise. A novel resonant absorber is designed to enhance response in the band of interest. We present noise and optical efficiency measurements of these detectors taken with a low background cryostat and a cryogenic blackbody. A microlens-hybridized KID array is found to be photon noise limited down to about 50 aW with a limiting detector NEP of about 6.5×10 −19 W/Hz 1/2 . A fit to an NEP model shows that our optical system is well characterized and understood down to 50 aW. We discuss future plans for low-volume aluminum KID array development as well as the testbeds used for these measurements.

Far-Infrared↗

A Laboratory Demonstration of the Capability to Image an Earth-like Extrasolar Planet

The detection and characterization of an Earth-like planet orbiting a nearby star requires a telescope with an extraordinarily large contrast at small angular separations. At visible wavelengths, an Earth-like planet would be 1 times 10-10 times fainter than the star at angular separations of typically 0.1 arcsecond or less. There are several proposed space telescope systems that could, in principle, achieve this. Here we report a laboratory experiment that reaches these limits. We have suppressed the diffracted and scattered light near a star-like source to a level of 6 times 10-10 times the peak intensity in individual coronagraph images. In a series of such images, together with simple image processing, we have effectively reduced this to a residual noise level of about 0.1 times 10-10. This demonstrates that a coronagraphic telescope in space could detect and spectroscopically characterize nearby exoplanetary systems, with the sensitivity to image an 'Earth-twin' orbiting a nearby star.

coronagraphic telescopes↗

The role of coherent structures in the generation of noise for subsonic jets

Acoustic measurements were made in the 'near' (r/D 60, x/D 60) field for high Reynolds number (184,000 to 262,000) axisymmetric cold air jets exhausting at atmospheric pressure. These measurements were in conjunction with an investigation which characterized the large scale coherent structure in the flow field of Mach number 0.6 to 0.8 jets. Natural jets as well as artificially excited jets were studied. Directivity plots were made for both natural jets and jets excited at various frequencies. Overall noise radiated by the jets reached a maximum value around 30 deg from the jet axis. However, individual frequencies emitted maximum sound pressure level at different angles from the jet axis. As the angle from the jet axis increased, the spectra of the noise shifted to higher frequencies.

Morrison, G. L.↗

Signal-Induced Noise Effects in a Photon Counting System for Stratospheric Ozone Measurement

Signal-induced noise (SIN) is a common effect resulting when a photomultiplier tube (PMT) is saturated, for a brief moment, with a high intensity light pulse. After the laser pulse is sent into the atmosphere a very large light return, from either the near-field or a cloud, causes the PMT to momentarily saturate. The PMT is gated off at this time so no signal is seen at the anode. When the PMT gate is turned on, the far-field light return from the atmosphere is observed. This signal is distorted, however because of the addition of SIN to the received light signal causing a slower than expected decay of the atmospheric signal return. We have characterized SIN responses to varying parameters of the incident light on the PMT. These varied parameters included incident wavelength, PMT voltage, incident intensity, and tube type. We found that only the amplitude of the SIN was effected by varying PMT voltages and light intensities. The amplitude increased linearly as input light intensity increased. Different incident wavelengths at the same intensity did not effect the amplitude or the temporal behavior of the SIN response. Finally, different PMT tubes with similar physical structures exhibited similar SIN responses although with different amplitudes. The different amplitudes can be attributed to the different gains and operating voltages of each tube. These results suggest that SIN is caused by photocathode electron dynamics such as charge accumulation on internal PMT surfaces. These surfaces then emit the electrons slowly resulting in a long decay noise signal. With the SIN responses characterized we can now try to develop a method to reduce or eliminate SIN in DIAL systems.

Harper, David B.↗

The structure of jet turbulence producing jet noise

The structure of the turbulence in the mixing region for the first few diameters downstream from the outlet of a circular subsonic jet is characterized at three Mach numbers, 0.3, 0.5, and 0.7, with most of the measurements taken at M = 0.3. Profiles of turbulence intensity showed that downstream of the lip intensity is independent of axial distance, while in the core intensity varies by a factor of eight between the jet outlet and the end of the core. A digital data reduction program was used to calculate the auto- and cross-correlations of axial velocity fluctuations and the power spectral densities. Convection velocities were measured using broadband, hot wire signals and signals that were digitally filtered for band-passes about center frequencies of 0.8, 1.3, 1.6, and 3.2 kHz. The center frequency of 1.3 kHz corresponded to the peak energy in the core spectrum. The results support the hypothesis that the coherent pressure field is driven by the intermittent fluctuations at the core boundary, which in turn are related to the large (low frequency) eddies.

Wooldridge, C. E.↗

The NANOGrav 12.5 yr Data Set: The Frequency Dependence of Pulse Jitter in Precision Millisecond Pulsars

Low-frequency gravitational-wave experiments require the highest timing precision from an array of the moststable millisecond pulsars. Several known sources of noise on short timescales in single radio pulsar observationsare well described by a simple model of three components: template fitting from a finite signal-to-noise ratio, pulsephase/amplitude jitter from single-pulse stochasticity, and scintillation errors from short-timescale interstellarscattering variations. Currently template-fitting errors dominate, but as radio telescopes push toward higher signalto-noise ratios, jitter becomes the next dominant term for most millisecond pulsars. Understanding the statistics ofjitter becomes crucial for properly characterizing arrival time uncertainties. We characterize the radio frequencydependence of jitter using data on 48 pulsars in the North American Nanohertz Observatory for GravitationalWaves timing program. We detect significant jitter in 43 of the pulsars and test several functional forms for itsfrequency dependence; we find significant frequency dependence for 30 pulsars. We find moderate correlations ofrms jitter with pulse width (R = 0.62) and number of profile components (R = 0.40); the single-pulse rms jitter istypically 1% of pulse phase. The average frequency dependence for all pulsars using a power-law model hasindex 0.42. We investigate the jitter variations for the interpulse of PSR B1937+21 and find no significantdeviations from the main pulse rms jitter. We also test the time variation of jitter in two pulsars and find thatsystematics likely bias the results for high-precision pulsars. Pulsar timing array analyses must properly modeljitter as a significant component of the noise within the detector.

Lam, M. T.↗

Reduction of turbomachinery noise

In the invention, propagating broad band and tonal acoustic components of noise characteristic of interaction of a turbomachine blade wake, produced by a turbomachine blade as the blade rotates, with a turbomachine component downstream of the rotating blade, are reduced. This is accomplished by injection of fluid into the blade wake through a port in the rotor blade. The mass flow rate of the fluid injected into the blade wake is selected to reduce the momentum deficit of the wake to correspondingly increase the time-mean velocity of the wake and decrease the turbulent velocity fluctuations of the wake. With this fluid injection, reduction of both propagating broad band and tonal acoustic components of noise produced by interaction of the blade wake with a turbomachine component downstream of the rotating blade is achieved. In a further noise reduction technique, boundary layer fluid is suctioned into the turbomachine blade through a suction port on the side of the blade that is characterized as the relatively low-pressure blade side. As with the fluid injection technique, the mass flow rate of the fluid suctioned into the blade is here selected to reduce the momentum deficit of the wake to correspondingly increase the time-mean velocity of the wake and decrease the turbulent velocity fluctuations of the wake; reduction of both propagating broad band and tonal acoustic components of noise produced by interaction of the blade wake with a turbomachine component downstream of the rotating blade is achieved with this suction technique. Blowing and suction techniques are also provided in the invention for reducing noise associated with the wake produced by fluid flow around a stationary blade upstream of a rotating turbomachine.

Waitz, Ian A.↗

‘Trapped Wave’ Resonance Tones Radiated in the Forward Arc of High-Speed Jets

An experimental study is conducted investigating the characteristics of ‘trapped wave’ resonance tones in the forward arc of jet noise radiation fields. While these spectral peaks disappear in the far acoustic field in the aft and sideline directions, which is why they went unnoticed in decades of jet noise measurements, the present study clearly shows that they radiate in the forward arc (shallow upstream polar locations in the approximate range of θ < 45°). Far-field jet noise spectra in the forward arc, data on which had been lacking in the literature, are not smooth but are characterized by these peaks. This is found for high subsonic to supersonic jets up to the highest jet Mach number covered in the experiment (MJ ≈ 1.9), for round, rectangular as well as convergent-divergent nozzles. With heated jets these spectral peaks are weakened especially around transonic conditions, however, they persist in supersonic conditions. Note that digital files containing all spectral data shown in the following are in a supplemental file to this NASA Technical Memorandum (TM-20240009873-SUPPL). These files can be obtained from the NASA Technical Report Server (NTRS) as a separate download from this report.

jets↗

AC Read-Out Circuits for Single Pixel Characterization of TES Microcalorimeters and Bolometers

SRON is developing Frequency Domain Multiplexing (FDM) for the read-out of transition edge sensor (TES) soft x-ray microcalorimeters for the XMS instrument of the International X-ray Observatory and far-infrared bolometers for the SAFARI instrument on the Japanese mission SPICA. In FDM the TESs are AC voltage biased at frequencies from 0.5 to 6 MHz in a superconducting LC resonant circuit and the signal is read-out by low noise and high dynamic range SQUIDs amplifiers. The TES works as an amplitude modulator. We report on several AC bias experiments performed on different detectors. In particular, we discuss the results on the characterization of Goddard Space Flight Center x-ray pixels and SRON bolometers. The paper focuses on the analysis of different read-out configurations developed to optimize the noise and the impedance matching between the detectors and the SQUID amplifier. A novel feedback network electronics has been developed to keep the SQUID in flux locked loop, when coupled to superconducting high Q circuits, and to optimally tune the resonant bias circuit. The achieved detector performances are discussed in view of the instrument requirement for the two space missions.

Gottardi, L.↗

An Early Assessment of JPSS-1/NOAA-20 VIIRS Day-Night Band On-Orbit Calibration and Performance

The JPSS-1 (now named NOAA-20) VIIRS instrument has been successfully operating on orbit since November 28th, 2017. The Day-Night Band (DNB) is a panchromatic channel covering wavelengths from 0.5 to 0.9 m that is capable of observing the Earth scene in visible/near-Infrared spectral range at spatial resolution of 750 m. The DNB operates at low, mid, or high radiometric gain stages, and it uses an onboard solar diffuser (SD) panel for low gain stage calibration. The SD observations also provide a mean to compute gain ratios between low-to-mid and mid-to-high gain stages. With their large dynamic range and high sensitivity, the DNB detectors can make observations during both daytime and nighttime. This paper provides an early assessment of the DNB on-orbit performance and behavior in the first 90-day post launch test (PLT) period and beyond. The calibration methodology used by the VIIRS Characterization Support Team (VCST) in support of the NASA earth science community will be presented. The trending of OBC dark-offsets, SD gains and gain ratios, and signal-to-noise ratio (SNR) at minimum radiance have been analyzed, especially during key events such as the Nadir and Cryo-cooler doors opening. Furthermore, we performed inter-comparison studies between SNPP and JPSS-1 instruments and evaluated DNB radiometric calibration and characterization, including the SD degradation, detector gains and gain ratios, as well as the calibration comparison between the IDPS LUTs and our VCST delivery results.

Chen, H.↗

Development of Low-Noise High Value Chromium Silicide Resistors for Cryogenic Detector Applications

Extremely high sensitivity detectors, such as silicon bolometers are required in many NASA missions for detection of photons from the x-ray to the far infrared regions. Typically, these detectors are cooled to well below the liquid helium (LHe) temperature (4.2 K) to achieve the maximum detection performance. As photoconductors, they are generally operated with a load resistor and a pre-set bias voltage, which is then coupled to the input gate of a source-follower Field Effect Transistor (FET) circuit. It is imperative that the detector system signal to noise performance be limited by the noise of the detector and not by the noise of the external components. The load resistor value is selected to optimize the detector performance. These two criteria tend to be contradictory in that these detectors require load resistors in the hundreds of megaohms, which leads to a higher Johnson noise. Additionally, the physical size of the resistor must be small for device integration as required by such missions as the NASA High Resolution Airborne Wide-Band Camera (HAWC) instrument and the Submillimeter High Angular Resolution Camera (SHARC) for the Caltech Submillimeter Observatory (CSO). We have designed, fabricated and characterized thin film resistors using a CrSi/TiW/Al metal system on optical quality quartz substrates. The resistor values range from 100 megaohms to over 650 megaohms and are Johnson noise limited at LHe temperatures. The resistor film is sputtered with a sheet resistance ranging from 300 ohms to 1600 ohms and the processing sequence developed for these devices allows for chemically fine tuning the sheet resistance in-situ. The wafer fabrication process was of sufficiently high yield (>80%) providing clusters of good resistors for integrated multiple detector channels, a very important feature in the assembly of these two instruments.

Jhabvala, Murzy↗

Profiling the Quito basin (Ecuador) using seismic ambient noise

SUMMARY Quito, the capital of Ecuador, with more than 2.5 M inhabitants, is exposed to a high seismic hazard due to its proximity to the Pacific subduction zone and active crustal faults, both capable of generating significant earthquakes. Furthermore, the city is located in an intermontane piggy-back basin prone to seismic wave amplification. To understand the basin’s seismic response and characterize its geological structure, 20 broad and medium frequency band seismic stations were deployed in Quito’s urban area between May 2016 and July 2018 that continuously recorded ambient seismic noise. We first compute horizontal-to-vertical spectral ratios to determine the resonant frequency distribution in the entire basin. Secondly, we cross-correlate seismic stations operating simultaneously to retrieve interstations surface-wave Green’s functions in the frequency range of 0.1–2 Hz. We find that Love waves travelling in the basin’s longitudinal direction (NNE–SSW) show much clearer correlograms than those from Rayleigh waves. We then compute Love wave phase-velocity dispersion curves and invert them in conjunction with the HVSR curves to obtain shear-wave velocity profiles throughout the city. The inversions highlight a clear difference in the basin’s structure between its northern and southern parts. In the centre and northern areas, the estimated basin depth and mean shear-wave velocity are about 200 m and 1800 ms−1, respectively, showing resonance frequency values between 0.6 and 0.7 Hz. On the contrary, the basement’s depth and shear-wave velocity in the southern part are about 900 m and 2500 ms−1, having a low resonance frequency value of around 0.3 Hz. This difference in structure between the centre-north and the south of the basin explains the spatial distribution of low-frequency seismic amplifications observed during the Mw 7.8 Pedernales earthquake in April 2016 in Quito.

Pacheco, D. (ORCID:0000000282355096)↗