Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

ANNIE: the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a Gadolinium-loaded water Cherenkov detector placed in the Booster Neutrino Beam (BNB) at the Fermi National Accelerator Laboratory, USA. The primary physics goal of ANNIE is to perform neutrino cross-section measurements that will constrain systematic uncertainties in the next generation of long-baseline neutrino experiments. The first measurement will be the multiplicity of final-state neutrons from neutrino-nucleus interactions in water. Alongside these measurements, ANNIE has achieved the first ever deployments of two novel detector technologies in a neutrino beam: Large Area Picosecond Photodetectors (LAPPDs) and Water-based Liquid Scintillator (WbLS). LAPPDs are micro-channel-plate-based devices that provide timing resolution of ~100 picoseconds and sub-centimeter spatial resolution. WbLS combines the low attenuation and Cherenkov production of pure water with the high light-yield and low detection threshold of liquid scintillator. This talk will discuss the status of ANNIE's physics and R&D measurements.

43 PARTICLE ACCELERATORS↗

Cadmium Magnesium Telluride for Next-Generation X-Ray Free Electron Laser, Synchrotron, and Many Other Applications

We developed a picosecond photodetector based on our Bridgman-grown and specially engineered cadmium magnesium telluride (Cd 1–x MgxTe) single crystal that is sensitive to both optical and X-ray pulses for coarse timing in free-electron laser applications. Cd 1–x MgxTe is a widebandgap semiconductor with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma-ray radiation, thermal neutrons, and medical imaging. For femtosecond optical and X-ray crosscorrelation, the material must have a very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have a very low bulk leakage current, in the 10–90 nA range for voltages to even 1000 V. Hence, the ability to tailor or engineer the material is very crucial. Picosecond response and the crystal growth of this specially engineered Cd 1–x MgxTe material are presented. Furthermore, other characterization and transient measurements are discussed along with room-temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

High-fidelity photoneutron detection via neutron activation analysis

To interdict illicit radioactive sources and prevent nuclear terror, governments have deployed portal monitor systems at ports of entry. Such portal monitors rely upon the detection of spontaneously-emitted radiation signatures, however, detection scenarios become more challenging for highly enriched uranium, which emits relatively few spontaneous radiation signatures. Photon active interrogation techniques can augment current cargo inspection scenarios and improve detection capabilities for illicit nuclear material. A high-energy photon interrogation source can induce photofission in nuclear material, producing strong radiation signatures for detection. Prompt fission signals are of specific interest because prompt neutrons are greater than 99% of the fission signal. When using detectors capable of spectroscopy, e.g., pulse shape discrimination-capable organic scintillators, the intense interrogating source often will cause pulse pile-up, degrading particle classification. In this work, we demonstrate photoneutron detection via neutron activation of aluminum and iron. The experiments rely upon nuclear reactions that can only be induced by neutrons, and are robust against pile-up, thereby providing high-confidence neutron rates. In this work, we apply neutron activation analysis for the detection of high-energy neutrons produced by high-energy photon irradiation; the depleted uranium sample was irradiated with a 9-MeV bremsstrahlung beam. We find that the irradiated depleted uranium produced an aluminum activation flux of 1.77 × 10 5 n cm –2 s –1 and an iron-56 activation flux of 1.05 × 10 5 n cm –2 s –1 . Furthermore, the ability to detect radioactivity induced by neutrons created in (, n) and photofission reactions demonstrates a new approach for photon active interrogation to identify nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of an Energy Tuning Assembly for High Explosives Detection

The Portable Isotopic Neutron Spectroscopy (PINS) system, employs neutron-induced gamma-ray spectroscopy and provides a nondestructive method for high explosives detection. In standard operation it uses Californium-252 as a neutron source. Operating PINS with a deuterium-tritium (DT) neutron generator has some advantages over Cf-252, including lifetime and ability to produce high-energy inelastic scattering gamma rays. However, current systems using DT neutron generators suffer from a high environmental background and reduced ability to induce neutron capture, reducing spectral quality and limiting nitrogen sensitivity. Here, this study presents the development of an energy-tuning assembly (ETA) designed to optimize the DT neutron energy spectrum to increase nitrogen reaction rates in a target, thereby improving high explosive detection capabilities. A metaheuristic optimization framework, MultiGNOWEE, coupled with MCNP, was employed to generate two ETA configurations: a single-objective ETA, which maximizes nitrogen capture reactions, and a multi-objective ETA, which balances neutron capture and inelastic scattering. Simulations demonstrated the optimized configurations achieved up to a 10-fold improvement in nitrogen capture rates compared to the bare configuration. Experimental validation was conducted using a DT neutron generator and a high-purity germanium (HPGe) detector. Two prototype ETAs were constructed and assessed on a melamine simulant. Measurements demonstrated improved nitrogen detection for both prototype ETA configurations when compared to the standard system.

97 MATHEMATICS AND COMPUTING↗

Simultaneous analysis of collinear neutron time-of-flight (nToF) traces applied to pulsed fusion experiment

On pulsed fusion experiments, the neutron time of flight (nToF) diagnostic provides critical information on the fusion neutron energy spectrum. This work presents an analysis technique that uses two collinear nToF detectors, potentially to measure nuclear bang time and directional flow velocities. Two collinear detectors may be sufficient to disambiguate the contributions of nuclear bang time and directional flow velocities to the first moment of the neutron energy spectrum, providing an independent measurement of nuclear bang time. In conclusion, preliminary results from measured nToF traces on the National Ignition Facility and additional applications of this technique are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advancements of the nSpec system

For this study, a new characterization of the detector response for the EJ301 liquid scintillator based nSpec system has been conducted at the Los Alamos Neutron Science Center. The new characterization was accomplished in two orders of magnitude less time and with better statistics than the previous characterization. The new and old characterization methods were compared by conducting both types of characterization on two detectors (one EJ301 and one EJ301D). The two methods show consistent results and compare well to results previously published in the literature; however, the results from the characterization of the original nSpec detector show discrepancies that have been identified as being caused by oxygen being absorbed into the detector due to a leak. The new characterized detector response shows improved spectrum unfolding performance than the previous characterization. The cross talk of the detector system was also characterized as a function of incident neutron energy and found to have a negligible impact on spectrum unfolding results. Alternative materials (EJ301D and stilbene) were also characterized in a first step towards an upgraded system. The different materials show little difference in unfolding performance, but the comparison is ongoing. A SiPM based stilbene detector was used to evaluate the use of SiPMs in a future system upgrade. The SiPM provides adequate performance, but the custom SiPM readout results in a much longer pulse width than PMT based systems. The measured light output of the SiPM based stilbene compares well with the results in literature. Future work will look at additional materials (deuterated stilbene and organic glass) and optimizing the SiPM readout to decrease the pulse width.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron source reconstruction using a generalized expectation–maximization algorithm on one-dimensional neutron images from the Z facility

Magnetized Liner Inertial Fusion experiments have been performed at the Z facility at Sandia National Laboratories. These experiments use deuterium fuel, which produces 2.45 MeV neutrons on reaching thermonuclear conditions. To study the spatial structure of neutron production, the one-dimensional imager of neutrons diagnostic was fielded to record axial resolved neutron images. In this diagnostic, neutrons passing through a rolled edge aperture form an image on a CR-39-based solid state nuclear track detector. In this report we present a modified generalized expectation–maximization algorithm to reconstruct an axial neutron emission profile of the stagnated fusion plasma. We validate the approach by comparing the reconstructed neutron emission profile to an x-ray emission profile provided by a time-integrated pinhole camera.

47 OTHER INSTRUMENTATION↗

Phased plan for the implementation of the time-resolving magnetic recoil spectrometer on the National Ignition Facility (NIF)

The time-resolving magnetic recoil spectrometer (MRSt) is a transformative diagnostic that will be used to measure the time-resolved neutron spectrum from an inertial confinement fusion implosion at the National Ignition Facility (NIF). It uses a CD foil on the outside of the hohlraum to convert fusion neutrons to recoil deuterons. An ion-optical system positioned outside the NIF target chamber energy-disperses and focuses forward-scattered deuterons. A pulse-dilation drift tube (PDDT) subsequently dilates, un-skews, and detects the signal. While the foil and ion-optical system have been designed, the PDDT requires more development before it can be implemented. Therefore, a phased plan is presented that first uses the foil and ion-optical systems with detectors that can be implemented immediately—namely CR-39 and hDISC streak cameras. These detectors will allow the MRSt to be commissioned in an intermediate stage and begin collecting data on a reduced timescale, while the PDDT is developed in parallel. A CR-39 detector will be used in phase 1 for the measurement of the time-integrated neutron spectra with excellent energy-resolution, necessary for the energy calibration of the system. Streak cameras will be used in phase 2 for measurement of the time-resolved spectrum with limited spectral coverage, which is sufficient to diagnose the time-resolved ion temperature. Simulations are presented that predict the performance of the streak camera detector, indicating that it will achieve excellent burn history measurements at current yields, and good time-resolved ion-temperature measurements at yields above 3 × 10 17 . The PDDT will be used for optimal efficiency and resolution in phase 3.

47 OTHER INSTRUMENTATION↗

AFRRI TRIGA Reactor Neutron and Gamma Dose Characterization Preliminary Results

Integral Experiment Request (IER) 484 is part of a series of dose characterization and nuclear accident dosimeter (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). The Armed Forces Radiobilogy Research Institute (AFRRI) 1.1 MW Training, Research, Isotopes, General Atomics (TRIGA) Mark-F reactor is the third facility to undergo a dose study to establish reference dose values. A preliminary measurement was performed earlier this year, where a variety of foils were irradiated and activation gamma rays were measured using a high-purity germanium (HPGe) detector. The data was taken and analyzed to calculate the neutron spectrum in the irradiation facility. This paper will present preliminary results of the neutron dose measured. The characterization of the AFRRI dose field is planned in August.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity

Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the light and charge responses of liquid xenon (LXe) to sub-keV nuclear recoils. Using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator, an in situ calibration was conducted on the LUX detector. We demonstrate direct measurements of light and charge yields down to 0.45 keV and 0.27 keV, respectively, both approaching single quanta production, the physical limit of LXe detectors. Furthermore, these results hold significant implications for the future of dual-phase xenon TPCs in detecting low-mass dark matter via nuclear recoils.

Dark matter detectors↗

Application of recoil-imaging time projection chambers to directional neutron background measurements in the SuperKEKB accelerator tunnel

Gaseous time projection chambers (TPCs) with high readout segmentation are capable of reconstructing detailed 3D ionization distributions of nuclear recoils resulting from elastic neutron scattering. Here, using a system of six compact TPCs with pixel ASIC readout, filled with a 70:30 mixture of He:CO 2 gas, we analyze the first directional measurements of beam-induced neutron backgrounds in the tunnel regions surrounding the Belle II detector at the SuperKEKB e + e – collider. With the use of 3D recoil tracking, we show that these TPCs are capable of maintaining nearly 100% nuclear recoil purity to reconstructed ionization energies (E reco ) as low as 5 keV ee . Using a large sample of Monte-Carlo (MC)-simulated 4 He, 12 C, and 16 O recoil tracks, we find consistency between predicted and measured recoil energy spectra in five of the six TPCs, providing useful validation of the neutron production mechanisms modeled in simulation. Restricting this sample to 4 He recoil tracks with E reco > 40 keV ee , we further demonstrate axial angular resolutions within 8° and we introduce a procedure that under suitable conditions, correctly assigns the vector direction to 91% of these simulated 4 He recoils. Applying this procedure to assign vector directions to measured 4 He recoil tracks, we observe consistency between the angular distributions of observed and simulated recoils, providing first experimental evidence of localized neutron “hotspots” in the accelerator tunnel. Observed rates of nuclear recoils in these TPCs suggest that simulation overestimates the neutron flux from these hotspots. Despite this, we estimate these hotspots to produce the majority of neutron backgrounds in the accelerator tunnel at SuperKEKB’s target luminosity of 6.3 x 10 35 cm –2 s –1 , making them important regions to continue to monitor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview [Slides]

This presentation discusses the Health Physics Research Reactor (HPRR) or Fast Burst Reactor (FBR) and how available data from Health Physics Research Reactor (HPRR) operation to can be used to create a benchmark report for inclusion in the ICSBEP, as a Criticality Accident Alarm System (CAAS) shielding benchmark. The evaluation of experimental data is also presented, specifically four experimental candidates are considered of potential value for the benchmark: 1. Neutron source estimation from a HPRR pulse (energy spectrum, fission yield), 2. Threshold Detector Unit (TDU) measurements at different distances from a HPRR pulse, shielded and unshielded, 3. Sulfur pellet activation at different distances from a HPRR pulse, shielded and unshielded, and 4. Total neutron fluence from a HPRR pulse measured by Bonner Sphere Spectrometry, shielded and unshielded. Additionally, a benchmark model overview is discussed as are sample calculation results.

61 RADIATION PROTECTION AND DOSIMETRY↗

The CLAS12 forward electromagnetic calorimeter

The CLAS12 Forward Detector includes six independent lead-scintillator electromagnetic sampling calorimeters to provide the primary electron trigger and extend the CLAS12 detection capability to photons and neutrons. Each calorimeter package consists of two modules, the legacy Electromagnetic Calorimeter (EC) previously used in the CLAS detector, and a new pre-shower calorimeter (PCAL) located in front of the EC to extend the total detector radiation length, in order to fully absorb the electromagnetic showers induced by electrons with energies up to 12 GeV. Both calorimeters use a novel triangular hodoscope geometry with stereo readout. The PCAL uses an upgraded design to provide the high spatial resolution necessary for reconstructing π 0 and η decays, and neutrons with high efficiency. Here, this paper treats the design, construction, and calibration of the PCAL and the preliminary combined performance of both detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and validation of a gamma-ray detection response model for neutron-diagnosed subcritical experiments

In a neutron-diagnosed subcritical experiment, a highly sensitive and fast detector is required to accurately determine the true fission γ-ray emission rate from an object composed of special nuclear material under interrogation, in addition to a proper detector response model for use in forward modeling. We present the development of a detector response model that is based in GEANT4 and uses post-processing techniques to include photomultiplier tube time and pulse height response effects. We also define a set of detector performance evaluation metrics that emphasized our experimental objectives. A suite of time and pulse height response measurements for several diverse detector assemblies are described. These assemblies were simulated with this response model and benchmarked against the laboratory measurements. This response model reproduces the pulse height curve shapes and performance hierarchy of the measured detectors well. Additionally, the simulated time response curves exhibit reasonable agreement with counterpart measurements. These measurements and simulation results together suggest that a large volume EJ-299-49 plastic scintillator that is mated to an ultraviolet transmitting plastic light guide and relies on total internal reflection for light transport to the photocathode will provide significantly faster timing, increase pulse height by a factor of 3, and require 25% less γ rays to meet experimental needs, compared to the candidate detector design developed prior to the availability of this response model. Application of this response model and associated performance metrics in the context of large-scale design sensitivity studies is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-fast single-crystal CVD diamonds in the particle time-of-flight (PTOF) detector for low yield burn-history measurements on the NIF (invited)

The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond-based detector and is the only diagnostic for measuring nuclear bang times of low yield (<1013) shots on the National Ignition Facility. Recently, a comprehensive study of detector impulse responses revealed certain detectors with very fast and consistent impulse responses with a rise time of <50 ps, enabling low yield burn history measurements. At the current standoff of 50 cm, this measurement is possible with fast 14 MeV neutrons from deuterium–tritium (DT) fusion plasmas. PTOF-inferred DT burn width numbers compare well with widths inferred from the gamma reaction history diagnostic on mid-yield (1013–1015) shots, where both systems are capable of making this measurement. These new capabilities could be extended to 2.5 MeV deuterium–deuterium neutrons from D plasmas and to even lower yield by reducing the detector standoff distance to 10 cm; a design for this is also presented.

42 ENGINEERING↗

Measurement of the cross section of the Q=4.4398 MeV 12 C (n, n'γ) reaction from threshold to 16.5 MeV using γ and correlated n–γ detection

The Q=4.4398 MeV 12 C (n, n'γ) cross section was measured using a white incident neutron source through the detection of γ rays only and n–γ coincidences using a segmented liquid scintillator detector array. While the n–γ technique utilized here is more generally applicable to a wide variety of neutron scattering measurements, the γ-only technique was successfully applied to this reaction to exploit the precise time resolution and high efficiency of this detection system to yield results with unprecedented statistical precision and total uncertainties < 2 % from reaction threshold up to 16 MeV incident neutron energy, clearly resolving many features in this reaction that were previously not well known. The γ-only and n–γ results are consistent with each other for the majority of the incident energy range covered in this paper, thereby lending validation to the n–γ technique for future measurements, though significant disagreements are observed between both results and with the ENDF/B-VIII.0 nuclear data evaluation. These differences are particularly noticeable in the recently evaluated energy range below 6.5 MeV, and also near 14 MeV where a “sawtooth”-like feature is observed similar to that in other 12 C+n reaction channels. Finally, both γ-only and n–γ results are presented here with thorough covariance derivations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cadmium Magnesium Telluride for Next Generation X-Ray Free Electron Laser, Synchrotron and Many Other Applications

We developed a picosecond photodetector based on our Bridgman grown and specially engineered Cadmium Magnesium Telluride (Cd 1-x Mg x Te) single crystal that is sensitive to both optical and x-ray pulses for coarse timing in Free Electron Laser applications. Cd 1-x Mg x Te is a wide bandgap semiconductor material with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma ray radiation, thermal neutrons, and medical imaging. However, for femtosecond optical and x-ray cross correlation, the material has to have very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have very low bulk leakage current, in the 0.10 pA range. Hence the ability to tailor or engineer the material is very crucial. In this paper, picosecond response and the crystal growth of this specially engineered cadmium magnesium telluride material will be presented. Other material characterization and transient measurements will also be discussed along with room temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗