Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE ATTENUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute

The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5 m × 2.5 m × 3 m, disturbances of the magnetic field are attenuated by factors of 5–50 at a bandwidth from 10{sup −3} Hz up to 0.5 Hz, which corresponds to integration times longer than several hundreds of seconds and represent the important timescale for the neutron electric dipole moment measurement. These shielding factors apply to random environmental noise from arbitrary sources. This is achieved via a proportional-integral feedback stabilization system that includes a regularized pseudoinverse matrix of proportionality factors which correlates magnetic field changes at all sensor positions to current changes in the SFC coils.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of a computer-controlled integrated optical gas-concentration sensor

A computer-controlled integrated optical waveguide sensor based on an optical waveguide of the diffusion type with the low attenuation coefficient is developed and studied. It is shown that the response time of the sensor is {approx}0.15 s. According to tests and computer simulations, the sensor can detect gaseous ammonia in air with the limiting theoretical concentration of {approx}0.1 ppm for the signal-to-noise ratio no less than 20. (laser applications and other topics in quantum electronics)

42 ENGINEERING↗

NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system

Purpose: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. Methods: The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. Results: The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. Conclusions: Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.

60 APPLIED LIFE SCIENCES↗

Jet transport noise - A comparison of predicted and measured noise for ILS and two-segment approaches

Centerline noise measured during standard ILS and two-segment approaches in DC-8-61 aircraft were compared with noise predicted for these procedures using an existing noise prediction technique. Measured data is considered to be in good agreement with predicted data. Ninety EPNdB sideline locations were calculated from flight data obtained during two-segment approaches and were compared with predicted 90 EPNdB contours that were computed using three different models for excess ground attenuation and a contour with no correction for ground attenuation. The contour not corrected for ground attenuation was in better agreement with the measured data.

White, K. C.↗

Uniform Foam Crush Testing for Multi-Mission Earth Entry Vehicle Impact Attenuation

Multi-Mission Earth Entry Vehicles (MMEEVs) are blunt-body vehicles designed with the purpose of transporting payloads from outer space to the surface of the Earth. To achieve high-reliability and minimum weight, MMEEVs avoid use of limited-reliability systems, such as parachutes and retro-rockets, instead using built-in impact attenuators to absorb energy remaining at impact to meet landing loads requirements. The Multi-Mission Systems Analysis for Planetary Entry (M-SAPE) parametric design tool is used to facilitate the design of MMEEVs and develop the trade space. Testing was conducted to characterize the material properties of several candidate impact foam attenuators to enhance M-SAPE analysis. In the current effort, four different Rohacell foams are tested at three different, uniform, strain rates (approximately 0.17, approximately 100, approximately 13,600%/s). The primary data analysis method uses a global data smoothing technique in the frequency domain to remove noise and system natural frequencies. The results from the data indicate that the filter and smoothing technique are successful in identifying the foam crush event and removing aberrations. The effect of strain rate increases with increasing foam density. The 71-WF-HT foam may support Mars Sample Return requirements. Several recommendations to improve the drop tower test technique are identified.

Patterson, Byron W.↗

Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging

Purpose: To investigate and compare the scatter rejection properties and low-contrast performance of the scan equalization digital radiography (SEDR) technique to the slot-scan and conventional full-field digital radiography techniques for chest imaging. Methods: A prototype SEDR system was designed and constructed with an a-Se flat-panel (FP) detector to improve image quality in heavily attenuating regions of an anthropomorphic chest phantom. Slot-scanning geometry was used to reject scattered radiation without attenuating primary x rays. The readout scheme of the FP was modified to erase accumulated scatter signals prior to image readout. A 24-segment beam width modulator was developed to regulate x-ray exposures regionally and compensate for the low x-ray flux in heavily attenuating regions. To measure the scatter-to-primary ratios (SPRs), a 2 mm thick lead plate with a 2-D array of aperture holes was used to measure the primary signals, which were then subtracted from those obtained without the lead plate to determine scatter components. A 2-D array of aluminum beads (3 mm in diameter) was used as the low-contrast objects to measure the contrast ratios (CRs) and contrast-to-noise ratios (CNRs) for evaluating the low-contrast performance in chest phantom images. A set of two images acquired with the same techniques were subtracted from each other to measure the noise levels. SPRs, CRs, and CNRs of the SEDR images were measured in four anatomical regions of chest phantom images and compared to those of slot-scan images and full-field images acquired with and without antiscatter grid. Results: The percentage reduction of SPR (percentage of SPRs reduced with scatter removal/rejection methods relative to that for nongrid full-field imaging) averaged over four anatomical regions was measured to be 80%, 83%, and 71% for SEDR, slot-scan, and full-field with grid, respectively. The average CR over four regions was found to improve over that for nongrid full-field imaging by 259%, 279%, and 145% for SEDR, slot-scan, and full-field with grid, respectively. The average CNR over four regions was found to improve over that for nongrid full-field imaging by 201% for SEDR as compared to 133% for the slot-scan technique and 14% for the antiscatter grid method. Conclusions: Both SEDR and slot-scan techniques outperformed the antiscatter grid method used in standard full-field radiography. For imaging with the same effective exposure, the SEDR technique offers no advantage over the slot-scan method in terms of SPRs and CRs. However, it improves CNRs significantly, especially in heavily attenuating regions. The improvement of low-contrast performance may help improve the detection of the lung nodules or other abnormalities and may offer SEDR the potential for dose reduction in chest radiography.

60 APPLIED LIFE SCIENCES↗

Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial results

Purpose: The purpose of this work is to present a performance study of the digital beam attenuator (DBA) for implementing fluence field modulated CT (FFMCT) using a simulation framework developed to model the incorporation of the DBA into an existing CT system. Additionally, initial results will be presented using a prototype DBA and the realization of the prototype will be described. To our knowledge, this study represents the first experimental use of a device capable of modulating x-ray fluence as a function of fan angle using a CT geometry. Methods: To realize FFMCT, the authors propose to use a wedge design in which one wedge is held stationary and another wedge is moved over the stationary wedge. Due to the wedge shape, the composite thickness of the two wedges changes as a function of the amount of overlap between the wedges. This design allows for the wedges to modulate the photon fluence incident onto a patient. Using a simulation environment, the effect of changing the number of wedges has on dose, scatter, detector dynamic range, and noise uniformity is explored. Experimental results are presented using a prototype DBA having ten Fe wedges and a c-arm CT system geometry. The experimental DBA results are compared to non-DBA scans using scatter and detector dynamic range as metrics. Both flat field and bowtie filtered CT acquisitions were simulated for comparison with the DBA. Results: Numerical results suggest that substantial gains in noise uniformity and scatter-to-primary ratio (SPR) can be obtained using only seven wedges. After seven wedges, the decrease in noise ununiformity and SPR falls off at a lower rate. Simulations comparing CT acquisitions between flat field, bowtie enabled, and DBA CT acquisitions suggest DBA-FFMCT can reduce dose relative to flat field CT by Almost-Equal-To 3 times. A bowtie filter under the same imaging conditions was shown to only allow a dose reduction of 1.65 times. Experimentally, a 10 wedge DBA prototype result showed a SPR reduction of Almost-Equal-To 4 times relative to flat field CT. The dynamic range for the DBA prototype was 3.7 compared to 84.2 for the flat field scan. Conclusions: Based on the results presented in this paper and the companion paper [T. Szczykutowicz and C. Mistretta, 'Design of a digital beam attenuation system for computed tomography. Part I. System design and simulation framework,' Med. Phys. 40, 021905 (2013)], FFMCT implemented via the DBA device seems feasible and should result in both a dose reduction and an improvement in image quality as judged by noise uniformity and scatter reduction. In addition, the dynamic range reduction achievable using the DBA may allow photon counting imaging to become a clinical reality. This study may allow for yet another step to be taken in the field of patient specific dose modulation.

60 APPLIED LIFE SCIENCES↗

Recent advances in multispectral sensing of ocean surface temperature from space

Visual and infrared measurements from the five channel AVHRR on the NOAA-7 satellite are used operationally to derive sea surface temperatures. The multichannel data perform daytime and nighttime cloud detection tests, and the several atmospheric window channels in the thermal infrared correct for atmospheric attenuation. Monitoring of the sea surface temperature product with buoy data indicates stability in mean bias and rms difference with little variation by season or geographic area. Global mapping enables the derivation of monthly mean isotherms, monthly and annual changes, and anomaly patterns relative to climatology. Problems are associated with noise in the 3.7 micro m window channel, and with the injection of substantial volcanic aerosol into the stratosphere by the El Chichon eruption. Multichannel sea surface temperature charts are used to study phenomena such as equatorial long waves and the recent El Nino episode.

Mcclain, E. P.↗

Effects of ray profile modeling on resolution recovery in clinical CT

Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. However, among vendors and researchers, there is no consensus of how to best achieve these goals. The authors are focusing on the aspect of geometric ray profile modeling, which is realized by some algorithms, while others model the ray as a straight line. The authors incorporate ray-modeling (RM) in nonregularized iterative reconstruction. That means, instead of using one simple single needle beam to represent the x-ray, the authors evaluate the double integral of attenuation path length over the finite source distribution and the finite detector element size in the numerical forward projection. Our investigations aim at analyzing the resolution recovery (RR) effects of RM. Resolution recovery means that frequencies can be recovered beyond the resolution limit of the imaging system. In order to evaluate, whether clinical CT images can benefit from modeling the geometrical properties of each x-ray, the authors performed a 2D simulation study of a clinical CT fan-beam geometry that includes the precise modeling of these geometrical properties. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and a Forbild thorax phantom with circular resolution patterns representing calcifications in the heart region are simulated. An FBP reconstruction with a Ram–Lak kernel is used as a reference reconstruction. The FBP is compared to iterative reconstruction techniques with and without RM: An ordered subsets convex (OSC) algorithm without any RM (OSC), an OSC where the forward projection is modeled concerning the finite focal spot and detector size (OSC-RM) and an OSC with RM and with a matched forward and backprojection pair (OSC-T-RM, T for transpose). In all cases, noise was matched to be able to focus on comparing spatial resolution. The authors use two different simulation settings. Both are based on the geometry of a typical clinical CT system (0.7 mm detector element size at isocenter, 1024 projections per rotation). Setting one has an exaggerated source width of 5.0 mm. Setting two has a realistically small source width of 0.5 mm. The authors also investigate the transition from setting one to two. To quantify image quality, the authors analyze line profiles through the resolution patterns to define a contrast factor (CF) for contrast-resolution plots, and the authors compare the normalized cross-correlation (NCC) with respect to the ground truth of the circular resolution patterns. To independently analyze whether RM is of advantage, the authors implemented several iterative reconstruction algorithms: The statistical iterative reconstruction algorithm OSC, the ordered subsets simultaneous algebraic reconstruction technique (OSSART) and another statistical iterative reconstruction algorithm, denoted with ordered subsets maximum likelihood (OSML) algorithm. All algorithms were implemented both without RM (denoted as OSC, OSSART, and OSML) and with RM (denoted as OSC-RM, OSSART-RM, and OSML-RM). Results: For the unrealistic case of a 5.0 mm focal spot the CF can be improved by a factor of two due to RM: the 4.2 LP/cm bar pattern, which is the first bar pattern that cannot be resolved without RM, can be easily resolved with RM. For the realistic case of a 0.5 mm focus, all results show approximately the same CF. The NCC shows no significant dependency on RM when the source width is smaller than 2.0 mm (as in clinical CT). From 2.0 mm to 5.0 mm focal spot size increasing improvements can be observed with RM. Conclusions: Geometric RM in iterative reconstruction helps improving spatial resolution, if the ray cross-section is significantly larger than the ray sampling distance. In clinical CT, however, the ray is not much thicker than the distance between neighboring ray centers, as the focal spot size is small and detector crosstalk is negligible, due to reflective coatings between detector elements. Therefore,RM appears not to be necessary in clinical CT to achieve resolution recovery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modulation of the neutron field in the multiplying condensed matter and coolant

The spatial damping of acoustic, neutron and thermal branches of oscillations are found in neutron multiplying medium with coolant. All three branches give additive contribution to the neutron density oscillations. However, their wave numbers and coefficients of spatial damping (at the same frequency) differ greatly from the sound with its high phase velocity and small attenuation to the neutron wave with the damping length, which is comparable with its wavelength. A spatial growth of neutron density oscillations is found in the case of large frequency of neutron capture and weak coupling of neutron density and temperature branches of oscillations. This fact is of importance for the noise diagnostics of the multiplying medium with coolant. The results can be applied to the development of the methods of noise diagnostics of the in core reactor equipment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An upper limit on ultraviolet shot noise from Cygnus X-1

Rapid photometry of Cygnus X-1 through an ultraviolet filter centered on 0.35 micron has been obtained at 100-ms sampling intervals. The autocorrelation function of these data has been examined for shot noise analogous to the behavior of the X-ray light curve. The ultraviolet data are entirely consistent with white noise. Considering randomly occurring ultraviolet shots with the same duration (0.5 s) and average rate (1 per sec) as the X-ray shots, a 3-sigma upper limit on the ratio of optical to X-ray energies per shot is estimated to be 0.13, before the ultraviolet light is attenuated by interstellar dust. This limit is then generalized for shots of arbitrary duration and rate.

Duthie, J. G.↗

SU-E-I-64: X-Ray Coherent Scatter Mammography Simulation

Purpose: Conventional mammography has poor contrast between healthy and cancerous tissues due to the small difference in attenuation properties. Coherent scatter potentially provides more information because interference of coherently scattered radiation depends on the average intermolecular spacing, and can be used to characterize tissue types. However, typical coherent scatter analysis techniques are not compatible with rapid low dose screening modalities. Coherent scatter slot scan imaging is a novel imaging technique which provides new information with higher contrast. In this work a simulation was performed of coherent scatter slot scan imaging to assess its performance and provide system optimization. Methods: In coherent scatter imaging, the coherent scatter is exploited using a conventional slot scan mammography system with anti-scatter grids tilted at the characteristic angle of cancerous tissues. A Monte Carlo simulation was used to simulate the coherent scatter imaging. System optimization was performed across several parameters, including source voltage and filtration, tilt angle, source and grid distances, grid ratio, and shielding geometry. Results: The contrast was high and increased as the grid tilt angle was increased beyond the characteristic angle for the modeled carcinoma, and as the source voltage increased. Source filtration did not have a significant effect on contrast. Increasing grid ratio improved contrast at the expense of decreasing the signal to noise ratio (SNR). As the tumor size is decreased, additional shields to block the fat signal are necessary in order to detect the cancer signal. Conclusion: Coherent scatter analysis using a wide slot setup is promising as an enhancement for screening mammography. This work was supported by National Institutes of Health, # 7 R01EB009715.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Objective characterization of GE Discovery CT750 HD scanner: Gemstone spectral imaging mode

Purpose: To objectively characterize the performance of the gemstone spectral imaging (GSI) mode of GE CT750 HD scanner from a user's perspective. Methods: A regular scan protocol that approximates the adult abdomen scan protocol frequently used in the authors' institute was selected as the baseline, and a GSI protocol (preset 11) that is similar to the regular protocol and has a moderate dose level (CTDI{sub vol}=26.27 mGy) was compared to the baseline protocol. The resolving power of both protocols was characterized in terms of modulation transfer functions and high contrast resolution bar readings. Their noise characteristics were studied through noise power spectra, and their low contrast detectability was compared via contrast-to-noise ratio. Material decomposition capability of GSI was evaluated by scanning iodine solutions of 9-24 mg/ml iodine concentration in a Gammex CT phantom and by examining the estimated iodine concentration. In addition, a formula describing the dependency of HU in iodine enhanced area on GSI monochromatic energies and iodine concentrations was provided and the theoretical values were compared with the measured results. Results: The resolutions levels of 50%, 10%, and 5% MTF of GSI monochromatic images at 65 keV agree with those of the regular protocol within 0.1 lp/cm. GSI monochromatic images at 65 keV demonstrated the lowest noise level among GSI images of different monochromatic energies and showed very similar noise magnitude and noise power distribution as compared to the regular protocol images. The CNR of 60 and 65 keV GSI monoimages are approximately 100% of those of the regular protocol images. Estimated iodine concentration levels agreed with the actual values within 2% when the iodine solutions were placed at 3, 9, 12 o'clock positions of the phantom; when iodine solutions were placed at the phantom center and at 6 o'clock position, higher discrepancies of 2%-10% were observed. The observed dependency of HU on keV and iodine concentration levels agreed with the expectation from x-ray attenuations. Conclusions: Equivalent performances were observed in the comparison between GSI 65 keV monochromatic images and images from a regular abdomen scan protocol. This suggests the possibility of GSI to be employed in routine abdominal scans, which would potentially offer more information through its capabilities of material decomposition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modulation of seismic noise near the San Jacinto fault in southern California: origin and observations of the cyclical time dependence and associated crustal properties

SUMMARY We examine the cyclic amplitude variation of seismic noise recorded by continuous three-component broad-band seismic data with durations spanning 91–713 d (2008–2011) from three different networks: Anza seismic network, IDA network and the transportable seismic array. These stations surround the San Jacinto Fault Zone (SJFZ) in southern California. We find the seismic noise amplitudes exhibit a cyclical variation between 0.3 and 7.2 Hz. The high-frequency (≥0.9 Hz) noise variations can be linked to human activity and are not a concern. Our primary interest is signals in the low frequencies (0.3–0.9 Hz), where the seismic noise is modulated by semi-diurnal tidal mode M2. These long-period (low-frequency) variations of seismic noise can be attributed to a temporal change of the ocean waves breaking at the shoreline, driven by ocean tidal loading. We focus on the M2 variation of seismic noise at f = 0.6 Hz, travelling distances of ∼92 km through the crust from offshore California to the inland Anza, California, region. Relative to the shoreline station, data from the inland stations show a phase lag of ∼ –12°, which we attribute to the cyclic change in M2 that can alter crustal seismic attenuation. We also find that for mode M2 at 0.6 Hz, the amplitude variations of the seismic quality factor (Q) depend on azimuth and varies from 0.22 per cent (southeast to northwest) to 1.28 per cent (northeast to southwest) with Q = 25 for Rayleigh waves. We propose the direction dependence of the Q variation at 0.6 Hz reflects the preferred orientation of subfaults parallel to the main faulting defined by the primarily N45°W strike of the SJFZ.

Geochemistry & Geophysics↗

Contrast-enhanced spectral mammography with a photon-counting detector

Purpose: Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. The authors have investigated a photon-counting spectral imaging system with two energy bins for contrast-enhanced mammography. System optimization and the potential benefit compared to conventional non-energy-resolved absorption imaging was studied. Methods: A framework for system characterization was set up that included quantum and anatomical noise and a theoretical model of the system was benchmarked to phantom measurements. Results: Optimal combination of the energy-resolved images corresponded approximately to minimization of the anatomical noise, which is commonly referred to as energy subtraction. In that case, an ideal-observer detectability index could be improved close to 50% compared to absorption imaging in the phantom study. Optimization with respect to the signal-to-quantum-noise ratio, commonly referred to as energy weighting, yielded only a minute improvement. In a simulation of a clinically more realistic case, spectral imaging was predicted to perform approximately 30% better than absorption imaging for an average glandularity breast with an average level of anatomical noise. For dense breast tissue and a high level of anatomical noise, however, a rise in detectability by a factor of 6 was predicted. Another {approx}70%-90% improvement was found to be within reach for an optimized system. Conclusions: Contrast-enhanced spectral mammography is feasible and beneficial with the current system, and there is room for additional improvements. Inclusion of anatomical noise is essential for optimizing spectral imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-BRE-04: Microbeam-Radiation-Therapy (MRT): Characterizing a Novel MRT Device Using High Resolution 3D Dosimetry

Purpose: The feasibility of MRT has recently been demonstrated utilizing a new technology of Carbon-Nano-Tube(CNT) field emission x-ray sources.This approach can deliver very high dose(10's of Gy) in narrow stripes(sub-mm) of radiation which enables the study of novel radiation treatment approaches. Here we investigate the application of highresolution (50um isotropic) PRESAGE/Optical-CT 3D dosimetry techniques to characterize the radiation delivered in this extremely dosimetrically challenging scenario. Methods: The CNT field emission x-ray source irradiator comprises of a linear cathode array and a novel collimator alignment system. This allows a precise delivery of high-energy small beams up to 160 kVp. A cylindrical dosimeter (∼2.2cm in height ∼2.5cm in diameter) was irradiated by CNT MRT delivering 3 strips of radiation with a nominal entrance dose of 32 Gy.A second dosimeter was irradiated with similar entrance dose, with a regular x-ray irradiator collimated to microscopical strip-beams. 50um (isotropic) 3D dosimetry was performed using an in-house optical-CT system designed and optimized for high resolution imaging (including a stray light deconvolution correction).The percentage depth dose (PDD), peak-to-valley ratio (PVR) and beam width (FWHM) data were obtained and analyzed in both cases. Results: High resolution 3D images were successfully achieved with the prototype system, enabling extraction of PDD and dose profiles. The PDDs for the CNT irradiation showed pronounced attenuation, but less build-up effect than that from the multibeam irradiation. The beam spacing between the three strips has an average value of 0.9mm while that for the 13 strips is 1.5 mm at a depth of 16.5 mm. The stray light corrected image shows line profiles with reduced noise and consistent PVR values. Conclusion: MRT dosimetry is extremely challenging due to the ultra small fields involved.This preliminary application of a novel, ultra-high resolution, optical-CT 3D dosimetry system shows promise, but further work is required to validate and investigate accuracy and artifacts. This work was supported by NIH R01CA100835.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of two inflow control devices for flight simulation of fan noise using a JT15D engine

The program was developed to accurately simulate flight fan noise on ground static test stands. The results generally indicated that both the induct and external ICD's were effective in reducing the inflow turbulence and the fan blade passing frequency tone generated by the turbulence. The external ICD was essentially transparent to the propagating fan tone but the induct ICD caused attenuation under most conditions.

Jones, W. L.↗

A broad-band microseismometer for planetary operations

There has recently been renewed interest in the development of instrumentation for making measurements on the surface of Mars. This is due to the Mars Environmental Survey (MESUR) Mission, for which approximately 16 small, long-lived (2-10 years), relatively inexpensive surface stations will be deployed in a planet-wide network. This will allow the investigation of processes (such as seismology and meteorology) which require the simultaneous measurement of phenomena at many widely spaced locations on the surface over a considerable length of time. Due to the large number of vehicles involved, the mass, power, and cost of the payload will be severely constrained. A seismometer has been identified as one of the highest priority instruments in the MESUR straw-man payload. The requirements for an effective seismic experiment on Mars place a number of constraints on any viable sensor design. First, a large number of sensors must be deployed in a long-lived global network in order to be able to locate many events reliably, provide good spatial sampling of the interior, and increase the probability of seismic detection in the event of localized seismicity and/or high attenuation. From a practical standpoint, this means that individual surface stations will necessarily be constrained in terms of cost, mass, and power. Landing and thermal control systems will probably be simple, in order to minimize cost, resulting in large impact accelerations and wide daily and seasonal thermal swings. The level of seismic noise will determine the maximum usable sensitivity for seismometer. Unfortunately, the ambient seismic noise level for Mars is not well known. However lunar seismic noise levels are several orders of magnitude below that of the Earth. Sensitivities on the order of 10(exp -11)g over a bandwidth of .04 to 20 Hz are thought to be necessary to fulfill the science objectives for a seimometer placed on the Martian surface. Silicon micromachined sensor technology offers techniques for the fabrication of monolithic, robust, compact, lower power and mass accelerometers. Conventional micro-machined accelerometers have been developed and are commercially available for high frequency and large acceleration measurements. The new seismometer we are developing incorporates certain principles of conventional silicon micromachined accelerometer technology. However, currently available silicon micromachined sensors offer inadequate sensitivity and bandwidth for the Mars seismometer application. Our implementation of an advanced silicon micromachined seismometer is based on principles recently developed at JPL for high-sensitivity position sensor technology.

Banerdt, W. B.↗