SEARCH · Engineering Papers
Results for “Modernization”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Extending Lean and Exhaust Gas Recirculation-Dilute Operating Limits of a Modern Gasoline Direct-Injection Engine Using a Low-Energy Transient Plasma Ignition System
The efficiency improvement and emissions reduction potential of lean and exhaust gas recirculation (EGR)-dilute operation of spark-ignition gasoline engines is well understood and documented. However, dilute operation is generally limited by deteriorating combustion stability with increasing inert gas levels. The combustion stability decreases due to reduced mixture flame speeds resulting in significantly increased combustion initiation periods and burn durations. A study was designed and executed to evaluate the potential to extend lean and EGR-dilute limits using a low-energy transient plasma ignition system. The low-energy transient plasma was generated by nanosecond pulses and its performance compared to a conventional transistorized coil ignition (TCI) system operated on an automotive, gasoline direct-injection (GDI) single-cylinder research engine. The experimental assessment was focused on steady-state experiments at the part load condition of 1500 rpm 5.6 bar indicated mean effective pressure (IMEP), where dilution tolerance is particularly critical to improving efficiency and emission performance. Experimental results suggest that the energy delivery process of the low-energy transient plasma ignition system significantly improves part load dilution tolerance by reducing the early flame development period. Statistical analysis of relevant combustion metrics was performed in order to further investigate the effects of the advanced ignition system on combustion stability. Results confirm that at select operating conditions EGR tolerance and lean limit could be improved by as much as 20% (from 22.7 to 27.1% EGR) and nearly 10% (from λ = 1.55 to 1.7) with the low-energy transient plasma ignition system.
EXTENDING LEAN AND EGR-DILUTE OPERATING LIMITS OF A MODERN GDI ENGINE USING A LOW-ENERGY TRANSIENT PLASMA IGNITION SYSTEM
The efficiency improvement and emissions reduction potential of lean and EGR dilute operation of spark-ignition gasoline engines is well understood and documented. However, dilute operation is generally limited by deteriorating combustion stability with increasing inert gas levels. The combustion stability decreases due to reduced mixture flame speeds resulting in significantly increased combustion initiation periods and burn durations. A study was designed and executed to evaluate the potential to extend lean and EGR-dilute limits using a low-energy transient plasma ignition system. The low-energy transient plasma was generated by nano-second pulses and its performance compared to a conventional transistorized coil ignition system operated on an automotive, gasoline direct injection (GDI) single-cylinder research engine. The experimental assessment was focused on steady-state experiments at the part load condition of 1500 rpm 5.6 bar IMEP, where dilution tolerance is particularly critical to improving efficiency and emissions performance. Experimental results suggest that the energy delivery process of the low-energy transient plasma ignition system significantly improves part load dilution tolerance by reducing the early flame development period. Statistical analysis of relevant combustion metrics was performed in order to further investigate the effects of the advanced ignition system on combustion stability. Results confirm that at select operating conditions EGR tolerance and lean limit could be improved by as much as 20% (from 22.7 to 27.1% EGR) and nearly 10% (from λ=1.55 to 1.7) with the low-energy transient plasma ignition system.
Modern Trends in Gamma Detection Systems for Emergency Response
Explore the source record for details and available documents.
The Modern Technology of Radiation Oncology, Volume 3: A Compendium for Medical Physicists and Radiation Oncologists
No abstract prepared.
MO-F-CAMPUS-J-01: A Novel and Efficient Daily QA Program for Both Modern Linear Accelerator and Optical Surface Motion Systems
Purpose: The camera-based optical surface monitoring system(OSMS) is a standard motion-tracking system for TrueBeam™ machine. Daily quality assurance(DQA) procedures for the TrueBeam and OSMS systems currently require multiple phantoms and test sequences. Machine Performance Check(MPC) uses the IsoCal™ phantom to test geometric and dosimetric aspects, and has been validated for routine TrueBeam DQA. This work examines the novel use of MPC to simultaneously conduct DQA of OSMS,utilizing one phantom and test sequence for QA of both the TrueBeam and OSMS systems. Methods: TrueBeam with 6 degree-of-freedom(6DOF) couch, MPC and OSMS were installed. The therapists routinely use MPC with the IsoCal phantom to verify geometric and dosimetric parameters with an automated sequence of varying gantry and collimator angles, MLC positions, and couch translations and rotations as the DQA for TrueBeam. A surface outline of the IsoCal phantom, generated from a CT dataset, was imported to OSMS and used to monitor the position of the phantom at isocenter and to track its movement up to 5cm/10°(yaw) and rotation in pitch and roll up to 3° in real time during the automated MPC sequence. Motion of the phantom throughout the MPC routine was compared to the couch position shown by the digital readout. Results: The coincidence of isocenter, as determined by OSMS, and TrueBeam radiation isocenter was within ±0.8mm/±0.8° in three axes. Between OSMS and TrueBeam 6DOF couch, the mean couch relative shifts/angles were within ±0.7mm/±0.8° for each axis. Reported pitch and roll values were within ±0.4mm/±0.4°. The total measurement time for each DQA session took approximately 5 minutes. Conclusion: Use of the IsoCal phantom and MPC for simultaneous DQA of TrueBeam and OSMS increases QA efficiency and reduces complexity. OSMS isocenter position and motion-tracking capability in 6DOF were verified in real-time and were found to be within 1mm of the expected value.
SU-F-T-426: Measurement of Dose Enhancement Due to Backscatter From Modern Dental Materials
Purpose: High-density materials used in dental restoration can cause significant localized dose enhancement due to electron backscatter in head-and-neck radiotherapy, increasing the risk of mucositis. The materials used in prosthetic dentistry have evolved in the last decades from metal alloys to ceramics. We aim to determine the dose enhancement caused by backscatter from currently-used dental materials. Methods: Measurements were performed for three different dental materials: lithium disilicate (Li{sub 2}Si{sub 2}O{sub 5}), zirconium dioxide (ZrO{sub 2}), and gold alloy. Small thin squares (2×2×0.15 cm{sup 3}) of the material were fabricated, and placed into a phantom composed of tissue-equivalent material. The phantom was irradiated with a single 6 MV photon field. A thin-window parallel-plate ion chamber was used to measure the dose at varying distances from the proximal interface between the material and the plastic. Results: The dose enhancement at the interface between the high-density and tissue-equivalent materials, relative to a homogeneous phantom, was 54% for the gold alloy, 31% for ZrO{sub 2}, and 9% for Li{sub 2}Si{sub 2}O{sub 5}. This enhancement decreased rapidly with distance from the interface, falling to 11%, 5%, and 0.5%, respectively, 2 mm from the interface. Comparisons with the modeling of this effect in treatment planning systems are performed. Conclusion: While dose enhancement due to dental restoration is smaller with ceramic materials than with metal alloys, it can still be significant. A spacer of about 2–3 mm would be effective in reducing this enhancement, even for metal alloys.
SU-G-IeP3-09: Investigating the Interplay of Antiscatter Grids with Modern Detectors and Image Processing in Digital Radiography
Purpose: To use phantom and simulation experiments to relate technique factors, patient size and antiscatter grid use to image quality in portable digital radiography (DR), in light of advancements in detector design and image processing. Methods: Image contrast-to-noise ratio (CNR) on a portable DR system (MobileDaRt Evolution, Shimadzu) was measured by imaging four aluminum inserts of varying thickness, superimposed on a Lucite slab phantom using a pediatric abdominal protocol. Three thicknesses of Lucite were used: 6.1cm, 12cm, and 18.2cm, with both 55 and 65 kVp beams. The mAs was set so that detector entrance exposure (DEE) was matched between kVp values. Each technique and phantom was used with and without an antiscatter grid (focused linear grid embedded in aluminum with an 8:1 ratio). The CNR-improvement-factor was then used to determine the thickness- and technique-dependent appropriateness of grid use. Finally, the same experiment was performed via Monte Carlo simulation, integrating incident energy fluence at each detector pixel, so that effects of detector design and image processing could be isolated from physical factors upstream of the detector. Results: The physical phantom experiment demonstrated a clear improvement for the lower tube voltage (55kVp), along with substantial CNR benefits with grid use for 12–18cm phantoms. Neither trend was evident with Monte Carlo, suggesting that suboptimal quantum-detection-efficiency and automated grid-removal could explain trends in kVp and grid use, respectively. Conclusion: Physical experiments demonstrate marked improvement in CNR when using a grid for phantoms of 12 and 18cm Lucite thickness (above ∼10cm soft-tissue equivalent). This benefit is likely due to image processing, as this result was not seen with Monte Carlo. The impact of image processing on image resolution should also be investigated, and the CNR benefit of low kVp and grid use should be weighed against the increased exposure time necessary to achieve adequate DEE.
Using ancient protein kinases to unravel a modern cancer drug’s mechanism
Evolution of dynamics affects function The drug Gleevac inhibits Abl kinases and is used to treat multiple cancers. The closely related Src kinases also play a role in cancer but are not inhibited effectively by Gleevac. Nevertheless, Gleevac-bound structures of Src and Abl are nearly identical. Based on this structural information and protein sequence data, Wilson et al. reconstructed the common ancestor of Src and Abl. Mutations that affected conformational dynamics caused Gleevac affinity to be gained on the evolutionary trajectory toward Abl and lost on the trajectory toward Src. Science , this issue p. 882
Microbial Diversity and Sulfur Cycling in an Early Earth Analogue: From Ancient Novelty to Modern Commonality
Life emerged and diversified in the absence of molecular oxygen. The prevailing anoxia and unique sulfur chemistry in the Paleo-, Meso-, and Neoarchean and early Proterozoic eras may have supported microbial communities that differ from those currently thriving on the earth’s surface. Zodletone spring in southwestern Oklahoma represents a unique habitat where spatial sampling could substitute for geological eras namely, from the anoxic, surficial light-exposed sediments simulating a preoxygenated earth to overlaid water column where air exposure simulates oxygen intrusion during the Neoproterozoic era. We document a remarkably diverse microbial community in the anoxic spring sediments, with 340/516 (65.89%) of genomes recovered in a metagenomic survey belonging to 200 bacterial and archaeal families that were either previously undescribed or that exhibit an extremely rare distribution on the current earth. Such diversity is underpinned by the widespread occurrence of sulfite, thiosulfate, tetrathionate, and sulfur reduction and the paucity of sulfate reduction machineries in these taxa.
Certification of Control Gas Mixtures Using Modern Spectroscopy: an Approach and Application
The possibility of using the available spectroscopic databases for high-precision measurements of spectral parameters of gases has been studied. A new approach to measuring concentrations of gaseous components (НCl, CO, NO, SO{sub 2}) in gas mixtures employing the HITRAN or GEISA spectroscopic databases has been proposed. A certification method of control gas mixtures using Fourier-transform IR spectroscopy has been developed to transfer the mole-fraction units to working standards in order to reduce the required number of reference standards and improve the accuracy of measurements.
Modern status of photonuclear data
The reliability of experimental cross sections obtained for (γ, 1n), (γ, 2n), and (γ, 3n) partial photoneutron reactions using beams of quasimonoenergetic annihilation photons and bremsstrahlung is analyzed by employing data for a large number of medium-heavy and heavy nuclei, including those of {sup 63,65}Cu, {sup 80}Se, {sup 90,91,94}Zr, {sup 115}In, {sup 112−124}Sn, {sup 133}Cs, {sup 138}Ba, {sup 159}Tb, {sup 181}Ta, {sup 186−192}Os, {sup 197}Au, {sup 208}Pb, and {sup 209}Bi. The ratios of the cross sections of definite partial reactions to the cross section of the neutron-yield reaction, F{sub i} = σ(γ, in)/σ(γ, xn), are used as criteria of experimental-data reliability. By definition, positive values of these ratios should not exceed the upper limits of 1.00, 0.50, 0.33,... for i = 1, 2, 3,..., respectively. For many nuclei, unreliable values of the above ratios were found to correlate clearly in various photon-energy regions F{sub i} with physically forbidden negative values of cross sections of partial reactions. On this basis, one can conclude that correspondent experimental data are unreliable. Significant systematic uncertainties of the methods used to determine photoneutron multiplicity are shown to be the main reason for this. New partial-reaction cross sections that satisfy the above data-reliability criteria were evaluated within an experimental–theoretical method [σ{sup eval}(γ, in) = F{sub i}{sup theor} (γ, in) × σ{sup expt}(γ, xn)] by employing the ratios F{sub i}{sup theor} (γ, in) calculated on the basis of a combined photonuclear-reaction model. It was obtained that cross sections evaluated in this way deviate substantially from the results of many experiments performed via neutron-multiplicity sorting, but, at the same time, agree with the results of alternative activation experiments. Prospects of employing methods that would provide, without recourse to photoneutron-multiplicity sorting, reliable data on cross sections of partial photoneutron reactions are discussed.
Study of Diffuse Supernova Neutrino Background with Modern and Future Detectors
Basic properties of the diffuse supernova neutrino background (DSNB) are reviewed. Current DSNB studies and the limits already set on the DSNB flow by the operating detectors Super-Kamiokande, SNO, and KamLAND are discussed. Prospects of DSNB studies with future high-mass neutrino detectors, such as JUNO and Hyper-Kamiokande, are considered.
Condensed matter research at the modernized IBR-2 reactor: from functional materials to nanobiotechnologies
An overview of the main scientific areas of condensed matter research, which are extended with the use of the IBR-2 high-flux research reactor, is presented. It is demonstrated that the spectrometer facility of the upgraded reactor has great potential for studying the structural, magnetic, and dynamical properties of novel functional materials and nanobiosystems, which ensures the leading position of the Joint Institute for Nuclear Research in neutron research of condensed matter for the long-term prospect.
Modern Purification Methods for Liquid Scintillators Intended for Recording Rare Events
— Chromato-mass-spectrometry and UV/VIS spectroscopy are used to study the composition and properties of linear alkyl benzene (LAB) produced in Russia as the basic solvent for production of low-background liquid scintillators. The efficiency of LAB purification by reducing intrinsic radioactivity (U, Th) via water extraction (with addition of a strong chelate, dimethylaminomethylendiphosphonic acid) and sorption on Al{sub 2}O{sub 3} in silica gel is studied. The purification method for removing potassium from scintillation fluors (PPO, BPO, p -terphenyl) is developed. It is shown that U and Th can be efficiently extracted from NdCl{sub 3} water solutions with 0.1 M TOPO solution in pseudocumene.
X-Ray Computer Methods for Studying the Structural Integrity of Seeds and Their Importance in Modern Seed Science
X-ray computer methods of research (projection microfocus radiography and microtomography), which are used to study the problem of hidden defects of seeds and investigate its impact on sowing quality, have been considered. The description and main characteristics of technical means that were used to obtain digital two-dimensional and three-dimensional (tomographic) X-ray images of seeds have been given and the possible ways of their quantitative computer processing and analysis have been discussed. Conclusions about the abilities of the methods of projection microfocus radiography and microtomography to study the features of the internal structures of a seed that are related to the violation of its integrity have been formulated.
A critical appraisal and evaluation of modern PDFs
Not Available
Memory Errors in Modern Systems: The Good, The Bad, and The Ugly
Several recent publications have shown that hardware faults in the memory subsystem are commonplace. These faults are predicted to become more frequent in future systems that contain orders of magnitude more DRAM and SRAM than found in current memory subsystems. These memory subsystems will need to provide resilience techniques to tolerate these faults when deployed in high-performance computing systems and data centers containing tens of thousands of nodes. Therefore, it is critical to understand the efficacy of current hardware resilience techniques to determine whether they will be suitable for future systems. In this paper, we present a study of DRAM and SRAM faults and errors from the field. We use data from two leadership-class high-performance computer systems to analyze the reliability impact of hardware resilience schemes that are deployed in current systems. Our study has several key findings about the efficacy of many currently deployed reliability techniques such as DRAM ECC, DDR address/command parity, and SRAM ECC and parity. We also perform a methodological study, and find that counting errors instead of faults, a common practice among researchers and data center operators, can lead to incorrect conclusions about system reliability. Lastly, we use our data to project the needs of future large-scale systems. We find that SRAM faults are unlikely to pose a significantly larger reliability threat in the future, while DRAM faults will be a major concern and stronger DRAM resilience schemes will be needed to maintain acceptable failure rates similar to those found on today's systems.