Operando x-ray photoelectron emission microscopy for studying forward and reverse biased silicon p-n junctions

Significant progress in the understanding of surfaces and interfaces of materials for new technologies requires operando studies, i.e., measurement of chemical, electronic, and magnetic properties under external stimulus (such as mechanical strain, optical illumination, or electric fields) applied in situ in order to approach real operating conditions. Electron microscopy attracts much interest, thanks to its ability to determine semiconductor doping at various scales in devices. Spectroscopic photoelectron emission microscopy (PEEM) is particularly powerful since it combines high spatial and energy resolution, allowing a comprehensive analysis of local work function, chemistry, and electronic structure using secondary, core level, and valence band electrons, respectively. Here we present the first operando spectroscopic PEEM study of a planar Si p-n junction under forward and reverse bias. The method can be used to characterize a vast range of materials at near device scales such as resistive oxides, conducting bridge memories and domain wall arrays in ferroelectrics photovoltaic devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional atomic force microscopy mapping at the solid-liquid interface with fast and flexible data acquisition

We present the implementation of a three-dimensional mapping routine for probing solid-liquid interfaces using frequency modulation atomic force microscopy. Our implementation enables fast and flexible data acquisition of up to 20 channels simultaneously. The acquired data can be directly synchronized with commercial atomic force microscope controllers, making our routine easily extendable for related techniques that require additional data channels, e.g., Kelvin probe force microscopy. Moreover, the closest approach of the tip to the sample is limited by a user-defined threshold, providing the possibility to prevent potential damage to the tip. The performance of our setup is demonstrated by visualizing the hydration structure above the calcite (10.4) surface in water.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Decoupling indirect topographic cross-talk in band excitation piezoresponse force microscopy imaging and spectroscopy

Here, all scanning probe microscopies are subjected to topographic cross-talk, meaning the topography-related contrast in functional images. Here, we investigate the signatures of indirect topographic cross-talk in piezoresponse force microscopy (PFM) imaging and spectroscopy and its decoupling using band excitation (BE) method in ferroelectric BaTiO 3 deposited on the Si substrates with free standing nanopillars of diameter 50 nm. Comparison between the single-frequency PFM and BE-PFM results shows that the measured signal can be significantly distorted by topography-induced shifts in the contact resonance frequency and cantilever transfer function. However, with proper correction, such shifts do not affect PFM imaging and hysteresis loop measurements. This suggests the necessity of an advanced approach, such as BE-PFM, for detection of intrinsic sample piezoresponse on the topographically non-uniform surfaces.

36 MATERIALS SCIENCE↗

Optimizing single-nanoparticle two-photon microscopy by in situ adaptive control of femtosecond pulses

Single-nanoparticle two-photon microscopy shows great application potential in super-resolution cell imaging. Here, we report in situ adaptive optimization of single-nanoparticle two-photon luminescence signals by phase and polarization modulations of broadband laser pulses. For polarization-independent quantum dots, phase-only optimization was carried out to compensate the phase dispersion at the focus of the objective. Enhancement of the two-photon excitation fluorescence intensity under dispersion-compensated femtosecond pulses was achieved. For polarization-dependent single gold nanorod, in situ polarization optimization resulted in further enhancement of two-photon photoluminescence intensity than phase-only optimization. The application of in situ adaptive control of femtosecond pulse provides a way for object-oriented optimization of single-nanoparticle two-photon microscopy for its future applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrochemomechanics with flexoelectricity and modelling of electrochemical strain microscopy in mixed ionic-electronic conductors

Recently, a new scanning probe microscopy approach, referred to as electrochemical strain microscopy (ESM), for probing local ionic flows and electrochemical reactions in solids based on the bias-strain coupling was proposed by Morozovska et al. Then, a series of theoretical papers for analyzing the image formation and spectroscopic mechanism of ESM were published within the framework of Fermi-Dirac statistics, the Vegard law, the direct flexoelectric coupling effect, the electrostriction effect, and so on. However, most of the models in these papers are limited to the partial coupling or particular process, and numerically solved by using decoupling approximation. In this paper, to model the ESM measurement with the coupling electrical-chemical-mechanical process, the chemical Gibbs function variational principle for the thermal electrical chemical mechanical fully coupling problem is proposed. The fully coupling governing equations are derived from the variational principle. When the tip concentrates the electric field within a small volume of the material, the inhomogeneous electric field is induced. So, both direct and inverse flexoelectric effects should be taken into account. Here, the bulk defect electrochemical reactions are also taken into account, which are usually omitted in the existing works. This theory can be used to deal with coupling problems in solids, including conductors, semiconductors, and piezoelectric and non-piezoelectric dielectrics. As an application of this work, a developed initial-boundary value problem is solved numerically in a mixed ion-electronic conductor. Numerical results show that it is meaningful and necessary to consider the bulk defect chemical reaction. Besides, the chemical reaction and the flexoelectric effect have an interactive influence on each other. This work can provide theoretical basis for the ESM as well as investigating the bulk chemical reaction process in solids.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Active voltage contrast imaging of cross-sectional surface of multilayer ceramic capacitor using helium ion microscopy

We studied active voltage contrast (AVC) imaging using helium ion microscopy (HIM). We observed secondary electron (SE) images of the cross-sectional surface of multilayer ceramic capacitors (MLCCs) with and without a voltage applied to the internal electrodes. When no voltage was applied, we obtained an image reflecting the material contrast between the Ni internal electrode region and the BaTiO{sub 3} dielectric region of the cross-sectional surface of the MLCC. When a voltage was applied, the electrical potential difference between the grounded and the positively biased internal electrodes affected the contrast (voltage contrast). Moreover, attenuation of the SE intensity from the grounded to the positively biased internal electrodes was observed in the dielectric region. Kelvin probe force microscopy (KPFM) measurements of the contact potential difference (CPD) were performed on the same sample. By using the AVC image from the HIM observation and the CPD image from the KPFM measurement, we could quantitatively evaluate the electrical potential. We think that the results of this study will lead to an expansion in the number of applications of HIM.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Active control of bright electron beams with RF optics for femtosecond microscopy

A frontier challenge in implementing femtosecond electron microscopy is to gain precise optical control of intense beams to mitigate collective space charge effects for significantly improving the throughput. Here, we explore the flexible uses of an RF cavity as a longitudinal lens in a high-intensity beam column for condensing the electron beams both temporally and spectrally, relevant to the design of ultrafast electron microscopy. Through the introduction of a novel atomic grating approach for characterization of electron bunch phase space and control optics, we elucidate the principles for predicting and controlling the phase space dynamics to reach optimal compressions at various electron densities and generating conditions. We provide strategies to identify high-brightness modes, achieving ∼100 fs and ∼1 eV resolutions with 106 electrons per bunch, and establish the scaling of performance for different bunch charges. These results benchmark the sensitivity and resolution from the fundamental beam brightness perspective and also validate the adaptive optics concept to enable delicate control of the density-dependent phase space structures to optimize the performance, including delivering ultrashort, monochromatic, high-dose, or coherent electron bunches.

43 PARTICLE ACCELERATORS↗

Separating grain-boundary and bulk recombination with time-resolved photoluminescence microscopy

Two-photon excitation (2PE) microscopy allows contactless and non-destructive cross-sectional analysis of grain-boundary (GB) and grain-interior (GI) properties in polycrystalline solar cells, with measurements of doping uniformity, space-charge field distribution, and carrier dynamics in different regions of the device. Using 2PE time-resolved microscopy, we analyzed charge-carrier lifetimes near the GBs and in the GI of polycrystalline thin-film CdTe solar cells doped with As. When the grain radius is larger than the minority-carrier diffusion length, GI lifetimes are interpreted as the bulk lifetimes ..tau..B, and GB recombination velocity SGB is extracted by comparing recombination rates in the GI and near GBs. In As-doped CdTe solar cells, we find ..tau..B = 1.0-2.4 ns and S GB = (1-4) x 10 5 cm/s. The results imply the potential to improve solar cell voltage via GB passivation and reduced recombination center concentration in the GI.

14 SOLAR ENERGY↗

Beyond single crystals: Imaging rubrene polymorphism across crystalline batches through lattice phonon Raman microscopy

Polymorphism is an issue troubling numerous scientific fields. A phenomenon where molecules can arrange in different orientations in a crystal lattice, polymorphism in the field of organic photovoltaic materials can dramatically change electronic properties of these materials. Rubrene is a benchmark photovoltaic material showing high carrier mobility in only one of its three polymorphs. To use rubrene in devices, it is important to quantify the polymorph distribution arising from a particular crystal growth method. However, current methods for characterizing polymorphism are either destructive or inefficient for batch scale characterization. Lattice phonon Raman spectroscopy has the ability to distinguish between polymorphs based on low frequency intermolecular vibrations. Here, we present here the addition of microscopy to lattice phonon Raman spectroscopy, which allows us to not only characterize polymorphs efficiently and nondestructively through Raman spectroscopy but also concurrently gain information on the size and morphology of the polymorphs. We provide examples for how this technique can be used to perform large, batch scale polymorph characterization for crystals grown from solution and physical vapor transport.We end with a case study showing how Raman microscopy can be used to efficiently optimize a green crystal growth method, selecting for large orthorhombic crystals desired for rubrene electronic device applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Element-specific first order reversal curves measured by magnetic transmission x-ray microscopy

The first-order reversal curve (FORC) method is a macroscopic measurement technique that can be used to extract quantitative and microscopic properties of hysteretic systems. Using magnetic transmission x-ray microscopy (MTXM), local element-specific FORC measurements are performed on a 20 nm thick film of CoTb. The FORCs measured with microscopy reveal a step-by-step domain evolution under the magnetic field cycling protocol and provide a direct visualization of the mechanistic interpretation of FORC diagrams. They are compared with magnetometry FORCs and show good quantitative agreement. Furthermore, the high spatial resolution and element-specific sensitivity of MTXM provide new capabilities to measure FORCs in small regions or specific phases within multicomponent systems, including buried layers in heterostructures. The ability to perform FORCs on very small features is demonstrated with the MTXM-FORC measurement of a rectangular microstructure with vortex-like Landau structures. This work demonstrates the confluence of two uniquely powerful techniques to achieve quantitative insight into nanoscale magnetic behavior.

36 MATERIALS SCIENCE↗

Multi-microscopy characterization of threading dislocations in CVD-grown diamond films

We present site-coincident imaging of a high dislocation density boron-doped chemical vapor deposition-grown homoepitaxial (001) diamond film using electron channeling contrast imaging (ECCI), cathodoluminescence, transmission electron microscopy (TEM), and scanning secondary ion mass spectroscopy (SIMS). With growing interest in large area heteroepitaxial substrates, we show that ECCI is a promising technique to accurately evaluate dislocations in diamond films. We find the electron backscatter yield is sufficient to distinguish individual threading dislocations in ECCI despite the low atomic number of carbon, and we have generally good agreement between dislocations observed in ECCI and TEM of the same region. Importantly, relying on luminescence in the 430 nm dislocation-related A-band alone results in an underestimation of the defect density as we find only 20%–40% of the threading dislocations luminesce. Here, we further show that dislocations do not perturb the spatial uniformity of boron doping measured by SIMS, even when the dislocations are clustered with high density, and we can tentatively rule out strong segregation effects at the dislocations. Our results establish the complementary use of microscopy and microanalysis methods to rapidly characterize and understand the impact of dislocations in diamond thin films.

36 MATERIALS SCIENCE↗

Near-field imaging of optical resonances in silicon metasurfaces using photoelectron microscopy

Precise control of light–matter interactions at the nanoscale lies at the heart of nanophotonics. However, experimental examination at this length scale is challenging since the corresponding electromagnetic near-field is often confined within volumes below the resolution of conventional optical microscopy. In semiconductor nanophotonics, electromagnetic fields are further restricted within the confines of individual subwavelength resonators, limiting access to critical light–matter interactions in these structures. In this work, we demonstrate that photoelectron emission microscopy (PEEM) can be used for polarization-resolved near-field spectroscopy and imaging of electromagnetic resonances supported by broken-symmetry silicon metasurfaces. We find that the photoemission results, enabled through an in situ potassium surface layer, are consistent with full-wave simulations and far-field reflectance measurements across visible and near-infrared wavelengths. In addition, we uncover a polarization-dependent evolution of collective resonances near the metasurface array edge taking advantage of the far-field excitation and full-field imaging of PEEM. Here, we deduce that coupling between eight resonators or more establishes the collective excitations of this metasurface. All told, we demonstrate that the high-spatial resolution hyperspectral imaging and far-field illumination of PEEM can be leveraged for the metrology of collective, non-local, optical resonances in semiconductor nanophotonic structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-photon fluorescence microscopy signal formation in highly scattering media: theoretical and numerical simulation

Using the radiative transfer theory and Monte Carlo simulations, we analyse the effect of scattering in a medium and of the size of the detector pinhole on the formation of the fluorescent signal in standard two-photon fluorescence microscopy (TPFM) systems. The theoretical analysis is based on a small-angle diffusion approximation of the radiative transfer equation, adapted to calculate the propagation of focused infrared radiation in media similar to the biological tissues in their optical properties. The accuracy of the model is evaluated by comparing the calculated excitation intensity in a highly scattering medium with the results of Monte Carlo simulations. To simulate a tightly focused Gaussian beam by the Monte Carlo method, the so called 'ray-optics' approach that correctly takes into account the finite size and shape of the beam waist is applied. It is shown that in the combined confocal and two-photon scanning microscopy systems not equipped with an external 'nondescanned' detector, the scattering significantly affects both the nonlinear excitation efficiency in the medium and the fluorescence collection efficiency of the system. In such systems, the rate of the useful TPFM signal in-depth decay is 1.5 - 2 times higher than in systems equipped with a 'nondescanned' detector. (application of lasers and laser-optical methods in life sciences)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Longitudinal correlation properties of an optical field with broad angular and frequency spectra and their manifestation in interference microscopy

The results of theoretical and experimental studies of the longitudinal correlation properties of an optical field with broad angular and frequency spectra and manifestations of these properties in interference microscopy are presented. The joint and competitive influence of the angular and frequency spectra of the object-probing field on the longitudinal resolution and on the amplitude of the interference microscope signals from the interfaces between the media inside a multilayer object is demonstrated. The method of compensating the so-called defocusing effect that arises in the interference microscopy using objectives with a large numerical aperture is experimentally demonstrated, which consists in using as a light source in the interference microscope an illuminating interferometer with a frequency-broadband light source. This method of compensation may be used as the basis of simultaneous determination of geometric thickness and refractive index of media forming a multilayer object. (optical fields)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of in vivo and ex vivo laser scanning microscopy and multiphoton tomography application for human and porcine skin imaging

Two state-of-the-art microscopic optical methods, namely, confocal laser scanning microscopy in the fluorescence and reflectance regimes and multiphoton tomography in the autofluorescence and second harmonic generation regimes, are compared for porcine skin ex vivo and healthy human skin in vivo. All skin layers such as stratum corneum (SC), stratum spinosum (SS), stratum basale (SB), papillary dermis (PD) and reticular dermis (RD) as well as transition zones between these skin layers are measured noninvasively at a high resolution, using the above mentioned microscopic methods. In the case of confocal laser scanning microscopy (CLSM), measurements in the fluorescence regime were performed by using a fluorescent dye whose topical application on the surface is well suited for the investigation of superficial SC and characterisation of the skin barrier function. For investigations of deeply located skin layers, such as SS, SB and PD, the fluorescent dye must be injected into the skin, which markedly limits fluorescence measurements using CLSM. In the case of reflection CLSM measurements, the obtained results can be compared to the results of multiphoton tomography (MPT) for all skin layers excluding RD. CLSM cannot distinguish between dermal collagen and elastin measuring their superposition in the RD. By using MPT, it is possible to analyse the collagen and elastin structures separately, which is important for the investigation of anti-aging processes. The resolution of MPT is superior to CLSM. The advantages and limitations of both methods are discussed and the differences and similarities between human and porcine skin are highlighted. (laser biophotonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superresolved multiphoton microscopy with spatial frequency-modulated imaging

Superresolved far-field microscopy has emerged as a powerful tool for investigating the structure of objects with resolution well below the diffraction limit of light. Nearly all superresolution imaging techniques reported to date rely on real energy states of fluorescent molecules to circumvent the diffraction limit, preventing superresolved imaging with contrast mechanisms that occur via virtual energy states, including harmonic generation (HG). Here, we report a superresolution technique based on spatial frequency-modulated imaging (SPIFI) that permits superresolved nonlinear microscopy with any contrast mechanism and with single-pixel detection. We show multimodal superresolved images with two-photon excited fluorescence (TPEF) and second-harmonic generation (SHG) from biological and inorganic media. Multiphoton SPIFI (MP-SPIFI) provides spatial resolution up to 2η below the diffraction limit, where η is the highest power of the nonlinear intensity response. MP-SPIFI can be used to provide enhanced resolution in optically thin media and may provide a solution for superresolved imaging deep in scattering media.

36 MATERIALS SCIENCE↗

Morphological Characterization of Uranyl Fluoride Particles via Atomic Force Microscopy

Uranium hexafluoride (UF 6 ) undergoes a rapid hydrolysis reaction when exposed to atmospheric water. In addition to producing hazardous HF gas, the hydrolysis reaction produces uranyl fluoride (UO 2 F 2 ), a radioactive solid phase particulate material. Because of the technological utility of UF 6 in the nuclear fuel cycle, understanding the transport properties of UO 2 F 2 aerosol produced via UF 6 hydrolysis is important for accident scenarios. Moreover, the fundamental chemical and physical properties of the UF 6 hydrolysis reaction are not completely understood. Recently, several experiments on the aerosol phase properties of UO 2 F 2 produced in this way have shown that under most relevant conditions, the particle size distribution (PSD) of UO 2 F 2 can be extremely small, approximately 3 to 5 nm, which is well below the threshold that can be routinely observed via scanning electron microscopy (SEM). Although readily observable in the aerosol phase, observation of nanometer-sized particles in the condensed phase (i.e. deposited on surfaces) remains a challenge. Here, in this study, we have used atomic force microscopy (AFM) to study the PSD and morphological characteristics of UO 2 F 2 deposited at low and high concentrations under different humidity conditions, a primary variable in the hydrolysis reaction. Here, we find strong agreement between PSD measured in the aerosol phase via scanning mobility particle sizing and PSD measured via AFM, with particle sizes peaked below 4 nm for low-humidity conditions. At higher humidity, the distribution is centered around 5 to 10 nm but extends up to 20 nm. These results are in stark contrast to previous measurements using SEM that show PSD on the order of 300- to 1000-nm particle sizes; moreover, these are the first direct measurements of individual particles of UO 2 F 2 having been produced via UF 6 hydrolysis deposited on surfaces. These measurements, therefore, open a new avenue for collecting and detecting UO 2 F 2 in the condensed phase and further refine the PSD, which is critical for environmental transport determinations.

Uranium hexafluoride↗

High-resolution Hard-x-ray Microscopy using Second-order Zone-plate Diffraction

Odd-order diffraction of zone plates (ZPs) is already used for x-ray microscopy but the potential offered by even-order diffraction must still be fully exploited. Width differences between lines and interline spaces transfer intensity from odd-order to even-order diffractions. Here we show that the resulting intense second-order diffraction provides a reasonable tradeoff between spatial resolution and intensity - and constitutes a viable strategy for x-ray microscopy to reach sub-20 nm resolution, in spite of the imperfections of high-aspect-ratio ZPs and of other difficulties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗