Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microgrids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Development of a Practical Secondary Control for Hardware Microgrids: Preprint

Practical vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids (MGs) with multiple grid-forming (GFM) inverter-based resources (IBRs) have not yet been developed. Therefore, this paper proposes a generic and vendor-agnostic secondary control architecture that works with all GFM IBRs and synchronous generators. This secondary control does not need to employ any additional measurement devices in the MG and uses the inherent communication systems of the GFM units, such as Modbus TCP/IP. The practical challenges of Modbus holding registers such as packet loss, quantization error, etc. and their deteriorating impacts on the secondary control action are investigated. The proposed three-stage modification of any secondary control architecture to eliminate these impacts includes 1) averaging the data read, 2) situational event-triggering of the controller, and 3) the finite iteration of the controlling action. The proposed method is validated using a laboratory hardware MG with commercial GFM units.

inverter based resources↗

RE+Microgrid Conference Presentation

Conference presentation about Idaho National Laboratory tools for damage prediction and resilience, along with an overview of microgrid capabilities.

Grid↗

New Safety Feedback Control Design to Guarantee Adequate Frequency Performance in Microgrids

Safety analysis of power systems is concerned with the system's ability to maintain critical variables within specified limits following a disturbance. Frequency control adequacy has become increasingly important as the system inertia decreases due to the increase in renewable energy penetration. Various controllers for inverters have been proposed to improve the system frequency response and few are capable to ensure the safety of the response. In this article, a diesel-wind energy system is considered and modeled as a switching system between normal, faulted, and post-fault modes. Further, a safety feedback controller is designed as a supplementary signal for a wind turbine generator such that the speed of the diesel generator stays within a permissible range in the presence of a finite energy disturbance. Numerical results on the modified 33-bus microgrid system obtained of the proposed novel approach indicate that the suggested control configuration can guarantee adequate frequency response without excessive conservativeness.

barrier function↗

Manufacturing of Ultra-Fine Particle Coal Fly Ash–A380 Aluminum Matrix Composites with Improved Mechanical Properties by Improved Ring Milling and Oscillating Microgrid Mixing

An experimental study is presented of ultra-fine coal fly ash (CFA) aluminum matrix composites produced by successive high-power ring milling of CFA, oscillating microgrid mixing of the CFA–aluminum melt, gravity casting and rapid cooling. Samples corresponding to different CFA concentrations and particle size distributions (1 μm average, or less) are produced and subjected to microstructural and mechanical characterization, including tensile, compressive, impact, hardness and wear testing. While the usual trade-off between increased strength and hardness and reduced ductility and toughness is observed, the obtained ultra-fine particle composites are confirmed to have overall improved mechanical properties compared to composites with larger size particles previously produced by ball milling.

36 MATERIALS SCIENCE↗

Microgrids 2025 editorial

We, the guest editors, thank everyone who has contributed to this virtual special issue (VSI), Microgrids 2025. This editorial includes a brief blurb for each accepted paper, collected in five loose areas. The topics represented do not settle neatly into categories, so we apologize in advance to any authors who find their work is not correctly represented. Within each section, the paper order reflects the sequence in which the manuscripts were submitted.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrids, virtual power plants and our distributed energy future

Opportunities for VPPs and microgrids will only increase dramatically with time, as the traditional system of building larger and larger centralized and polluting power plants by utilities charging a regulated rate of return fades. The key questions are: how soon will these new business models thrive - and who will be in the driver's seat? (author)

20 FOSSIL-FUELED POWER PLANTS↗

Resilient distribution system leveraging distributed generation and microgrids: a review

With the aging of electricity transmission and distribution infrastructures and increasing intensity of extreme weather events, the aggravated vulnerability of electric distribution systems to extreme weather events has motivated the study of resilient distribution systems. This study presents a review of the state-of-the-art research on distribution grid resilience. First, the definition and quantifying metrics of resilience in the electrical distribution system are summarised. Second, the long-term and short-term measures to enhance the distribution system resilience are discussed. In particular, the recent studies on distributed generation and microgrid-assisted resilience enhancements are reviewed. Finally, recommendations for future research are presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Robust Communication-Free Protection Scheme for Islanded Microgrids with Relay Logic and Hardware-in-the-Loop Validation

This paper presents the Imbalance Square Factor (ISF) detection algorithm, an effective, computationally lightweight method for detecting faults in inverter-based microgrids. ISF provides a high magnitude at the time of the fault, which allows for fast detection and coordination between primary and backup relays. The imbalance squared factor, calculated using local voltage and currents, is used for fault detection and coordination among three relays. ISF is validated in hardware-in-the-loop (HIL) implementation inside commercial-grade relay logic (SEL-751). The HIL validation shows that ISF can coordinate primary, secondary, and tertiary relays in the 13-bus system in islanded operation.

Ferrari Maglia, Max [ORNL]↗

Integration of Electrolysis Systems Into Isolated Microgrid Systems at Extreme Cold Climates

Isolated microgrid systems are generally used to power communities in remote locations where transmission line installations are cost prohibitive. These systems are usually powered by diesel generators, delivering expensive energy with high carbon emissions. However, most of these communities have special geographic access to renewable energy. These special conditions make it interesting to investigate the deployment of renewable energies and storage solutions. Within this scope, this paper analyses the integration of water electrolysis systems into off-grid communities, simulating the electrolyzer as well as the whole electrical grid in real time.

digital real-time simulation↗

Study of Seamless Microgrid Transition Operation Using Grid-Forming Inverters

This paper investigates operational techniques to achieve seamless (smooth) microgrid (MG) transitions by dispatching a grid-forming (GFM) inverter. In traditional approaches, the GFM inverter must switch between grid-following (GFL) and GFM control modes during MG transition operation. Today's inverter technology allows GFM inverters to always operate in GFM control mode, so it is worth exploring how to use them to achieve smooth MG transition operation. This paper proposes three operational techniques: a traditional scheme of switching between GFL and GFM control; a new scheme of consistent GFM control and shifting the droop intercept up before islanding operation; and a new scheme of consistent GFM control and shifting the droop intercept up before synchronization operation. A full hardware setup is established to compare the three techniques and showcase their implementations in real-world applications. The results show that the third technique outperforms the others and exhibits the best transition performance because the GFM inverter maintains the same operating points during the transition operation. Therefore, we conclude that ensuring smooth MG transition operation requires that the GFM inverter(s) maintain the same operating points (v, f, P, Q, and phase angle) during the transition operation in addition to minimizes the point of common coupling power flow.

grid-forming control↗

Performance Guaranteed Inertia Emulation for Diesel-Wind System Feed Microgrid via Model Reference Control

In this paper, a model reference control based inertia emulation strategy is proposed. Desired inertia can be precisely emulated through this control strategy so that guaranteed performance is ensured. A typical frequency response model with parametrical inertia is set to be the reference model. A measurement at a specific location delivers the information of disturbance acting on the diesel-wind system to the reference model. The objective is for the speed of the diesel-wind system to track the reference model. Since active power variation is dominantly governed by mechanical dynamics and modes, only mechanical dynamics and states, i.e., a swing-engine-governor system plus a reduced-order wind turbine generator, are involved in the feedback control design. The controller is implemented in a three-phase diesel-wind system feed microgrid. The results show exact synthetic inertia is emulated, leading to guaranteed performance and safety bounds.

Zhang, Yichen↗

Community Microgrid Planning Considering Building Thermal Dynamics

In this paper, the building thermal dynamic characteristics are introduced in the community microgrid (MG) planning model. The proposed planning model is formulated as a mixed integer linear programming (MILP) which seeks to determine the optimal deployment strategy for various distributed energy resources (DER). The objective is to minimize the annualized cost of community MG, including investment cost in DER, operation cost for dispatchable fuel-generators (DFG), energy storage system (ESS) degradation cost, energy purchasing and peak demand charge at PCC, customer discomfort cost due to the room temperature deviation and load curtailment cost. Given the slow thermal dynamic characteristics of buildings, the heating, ventilation and air-conditioning (HVAC) system in the proposed model is treated as a demand side management (DSM) component, whose dispatch commands are provided by the central MG controller. Numerical results based on a community MG comprising of 20 residential buildings demonstrate the effectiveness of the proposed planning model and the benefits of introducing the building thermal dynamic model.

Zhang, Xiaohu↗

Networked Microgrid Operations: Supporting a Resilient Electric Power Infrastructure

Modern electric power systems operate using large generating units managed with a centralized control structure. The current systems are the result of over a hundred years of technological development and consolidation to leverage economies of scale. While the existing systems have proven cost effective and reliable, modern systems are experiencing a wide range of operational challenges that are causing a reexamination of the centralized control structure. Despite the nearly universal adoption of centralized control, electric power systems are fractal in their operational requirements. Specifically, the fundamental operational requirements are the same, regardless of the system size. While past technologies have not allowed for exploitation of this fractal behavior, emerging technologies are making it possible; these technologies include grid-forming inverters, modern telecommunications systems, and distributed control architectures. Here we show emerging technologies that allow the fractal operational requirements of electric power systems to be exploited as networked microgrids to increase the resiliency of the world’s critical electrical infrastructure.

Schneider, Kevin P.↗

Synthesizing Distributed Energy Resources in Microgrids with Temporal Logic Specifications

Grid supportive modes integrated within distributed energy resources aim at improving the frequency response. However, hybrid behaviors induced by deadbands and other thresholds and their impact on system frequency remain unclear. This paper employs the parametric metric temporal logic specification for validating such behaviors to ensure adequate frequency response. It allows a richer description of system protections like under-frequency load shedding and can explore the temporal specification of frequency dynamics. The approach is applied on a diesel-wind fed microgrid and appropriate settings of deadband will be obtained, which can be regarded as a guideline for practitioners. The results are expected to be less conservative since the temporal properties are taken into accounts.

Zhang, Yichen↗

A Novel Grid-forming Voltage Control Strategy for Supplying Unbalanced Microgrid Loads Using Inverter-based Resources

This paper presents a novel grid-forming voltage control strategy for a battery energy storage system to maintain balanced three-phase output voltages when serving unbalanced loads. A stationary reference frame (αβ) based control scheme is proposed to regulate positive-sequence and negative-sequence voltages. Compared with the conventional rotating reference frame (dq) based control scheme, the proposed scheme shows better dynamic performance. Then, we analyze the system zero-sequence network and propose adding a grounding transformer to the Y/Yg connected output transformer to further reduce the voltage unbalance at the point of common coupling. The simulation results demonstrate the effective performance of the proposed voltage control scheme. Based on the results, the power-voltage unbalance curve is derived for different output transformer configurations to establish the relationship between the power unbalance limit and the voltage unbalance limit for microgrid power scheduling.

Xu, Bei↗

Improved microgrid resiliency through distributionally robust optimization under a policy-mode framework

Critical energy infrastructure are constantly under stress due to the ever increasing disruptions caused by wildfires, hurricanes, other weather related extreme events and cyber-attacks. Hence it becomes important to make critical infrastructure resilient to threats from such cyber-physical events. However, such events are hard to predict and numerous in nature and type and it becomes infeasible to make a system resilient to every possible such cyber-physical event. Such an approach can make the system operation overly conservative and impractical to operate. Furthermore, distributions of such events are hard to predict and historical data available on such events can be very sparse, making the problem even harder to solve. To deal with these issues, in this paper we present a policy-mode framework that enumerates and predicts the probability of various cyber-physical events and then a distributionally robust optimization (DRO) formulation that is robust to the sparsity of the available historical data. The proposed algorithm is illustrated on an islanded microgrid example: a modified IEEE 123-node feeder with distributed energy resources (DERs) and energy storage. Simulations are carried to validate the resiliency metrics under the sampled disruption events.

Nazir, Mohammad Nawaf↗