Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MUSCLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Low Mass Muscle Actuators (LoMMAs) Using Electroactive Polymers

NASA is using actuation devices for many space applications and there is an increasing need to cut their cost as well as reduce their size, mass, and power consumption. Existing transducing actuators, such as piezoceramics, are inducing limited displacement levels. Potentially, electroactive polymers (so called EAP) can be formed as inexpensive, low-mass, low-power, miniature muscle actuators that are superior to the widely used actuators.

actuators electroactive polymers active materials↗

Biologically inspired toys using artificial muscles

Recent developments in electroactive polymers, so-called artificial muscles, could one day be used to make bionics possible. Meanwhile, as this technology evolves novel mechanisms are expected to emerge that are biologically inspired.

bionics↗

Supine Treadmill Exercise in Lower Body Negative Pressure Combined with Resistive Exercise Counteracts Bone Loss, Reduced Aerobic Upright Exercise Capacity and Reduced Muscle Strength

Long-term exposure to weightlessness leads to cardiovascular and musculoskeletal deconditioning. In this report, the effectiveness of combined supine treadmill exercise in a lower body negative pressure chamber (LBNPex) and flywheel resistive exercise (Rex) countermeasures was determined to prevent bone loss, reduced aerobic upright exercise capacity and reduced muscle strength. We hypothesized that exercise subjects would show less decrease in bone mineral density (BMD), peak oxygen consumption (VO2pk) and knee extensor strength (KES) than control subjects. Sixteen healthy female subjects participated in a 60-d 6(sup 0) head-down tilt bed rest (BR) study after providing written informed consent. Subjects were assigned to one of two groups: a non-exercising control group CON or an exercise group EX performing LBNPex 2-4 d/wk and Rex every 3rd-d. VO2pk was measured with a maximal, graded, upright treadmill test performed pre-BR and on 3-d after BR. BMD was assessed before and 3-d after BR. Isokinetic KES was measured before and 5-d after BR. Two-way repeated measures ANOVA were performed. Statistical significance was set at p less than 0.05. CON experienced a significant decrease in BMD in the trochanter (PRE: 0.670 plus or minus 0.045; POST: 0.646 plus or minus 0.352 g (raised dot) per square centimeter) and in the whole hip (PRE=0.894 plus or minus 0.059; POST: 0.858 plus or minus 0.057 g (raised dot) per square centimeter). BMD also decreased significantly in EX in the trochanter (PRE: 0.753 plus or minus 0.0617; POST: 0.741 plus or minus 0.061 g (raised dot) per square centimeter) and whole hip (PRE: 0.954 plus or minus 0.067; POST: 0.935 plus or minus 0.069 g (raised dot) per square centimeter). BMD losses were significantly less in EX than in CON subjects. VO2pk was significantly decreased in the CON after BR (PRE: 38.0 plus or minus 4.8; POST: 29.9 plus or minus 4.2 ml (raised dot) per kilogram per minute), but not in the EX (PRE: 39.0 plus or minus 2.0; POST: 37.8 plus or minus 1.9 ml (raised dot) per kilogram per minute). KES was significantly reduced by 30% in Con (PRE: 113 plus or minus 12; POST: 78 plus or minus 8 N-m), but was not different in EX (PRE: 126 plus or minus 25; POST: 115 plus or minus 25 N-m). The combination LBNPex and Rex during 60-d BR protects against cardiovascular and musculoskeletal deconditioning and may be efficacious countermeasure for prolonged space flight.

Meuche, Sabine↗

Automated quantitative muscle biopsy analysis system

An automated system to aid the diagnosis of neuromuscular diseases by producing fiber size histograms utilizing histochemically stained muscle biopsy tissue. Televised images of the microscopic fibers are processed electronically by a multi-microprocessor computer, which isolates, measures, and classifies the fibers and displays the fiber size distribution. The architecture of the multi-microprocessor computer, which is iterated to any required degree of complexity, features a series of individual microprocessors P.sub.n each receiving data from a shared memory M.sub.n-1 and outputing processed data to a separate shared memory M.sub.n+1 under control of a program stored in dedicated memory M.sub.n.

Castleman, Kenneth R.↗

Biosensors for EVA: Muscle Oxygen and pH During Walking, Running and Simulated Reduced Gravity

During lunar excursions in the EVA suit, real-time measurement of metabolic rate is required to manage consumables and guide activities to ensure safe return to the base. Metabolic rate, or oxygen consumption (VO2), is normally measured from pulmonary parameters but cannot be determined with standard techniques in the oxygen-rich environment of a spacesuit. Our group developed novel near infrared spectroscopic (NIRS) methods to calculate muscle oxygen saturation (SmO2), hematocrit, and pH, and we recently demonstrated that we can use our NIRS sensor to measure VO2 on the leg during cycling. Our NSBRI-funded project is looking to extend this methodology to examine activities which more appropriately represent EVA activities, such as walking and running and to better understand factors that determine the metabolic cost of exercise in both normal and lunar gravity. Our 4 year project specifically addresses risk: ExMC 4.18: Lack of adequate biomedical monitoring capability for Constellation EVA Suits and EPSP risk: Risk of compromised EVA performance and crew health due to inadequate EVA suit systems.

Lee, S. M. C.↗

A Ground-Based Comparison of the Muscle Atrophy Research and Exercise System (MARES) and a Standard Isokinetic Dynamometer

PURPOSE: 1) To compare the test-to-test reliability of Muscle Atrophy Research and Exercise System (MARES) with a standard laboratory isokinetic dynamometer (ISOK DYN) and; 2) to determine if measures of peak torque and total work differ between devices. METHODS: Ten subjects (6M, 4F) completed two trials on both MARES and an ISOK DYN in a counterbalanced order. Peak torque values at 60 deg & 180 deg / s were obtained from five maximal repetitions of knee extension (KE) and knee flexion (KF). Total work at 180 deg / s was determined from the area under the torque vs. displacement curve during twenty maximal repetitions of KE and KF. Reliability of measures within devices was interpreted from the intraclass correlation coefficient (ICC) and compared between devices using the ratio of the within-device standard deviations. Indicators of agreement for the two devices were evaluated from: 1) a calculation of concordance (rho) and; 2) the correlation between the mean of measures versus the delta difference between measures (m u vs delta). RESULTS: For all outcome measures ICCs were high for both the ISOK DYN (0.95-0.99) and MARES (0.90-0.99). However, ratios of the within-device standard deviation were 1.3 to 4.3 times higher on MARES. On average, a wide range (3.3 to 1054 Nm) of differences existed between the values obtained. Only KE peak torque measured at 60 deg & 180 deg / s showed similarities between devices (rho = 0.91 & 0.87; Pearson's r for m u vs delta = -0.22 & -0.37, respectively). CONCLUSION: Although MARES was designed for use in microgravity it was quite reliable during ground-based testing. However, MARES was consistently more variable than an ISOK DYN. Future longitudinal studies evaluating a change in isokinetic peak torque or total work should be limited within one device.

Hackney, K. J.↗

Prediction of Muscle Performance During Dynamic Repetitive Exercise

A method for predicting human muscle performance was developed. Eight test subjects performed a repetitive dynamic exercise to failure using a Lordex spinal machine. Electromyography (EMG) data was collected from the erector spinae. Evaluation of the EMG data using a 5th order Autoregressive (AR) model and statistical regression analysis revealed that an AR parameter, the mean average magnitude of AR poles, can predict performance to failure as early as the second repetition of the exercise. Potential applications to the space program include evaluating on-orbit countermeasure effectiveness, maximizing post-flight recovery, and future real-time monitoring capability during Extravehicular Activity.

Byerly, D. L.↗

A Simple GPU-Accelerated Two-Dimensional MUSCL-Hancock Solver for Ideal Magnetohydrodynamics

We describe our experience using NVIDIA's CUDA (Compute Unified Device Architecture) C programming environment to implement a two-dimensional second-order MUSCL-Hancock ideal magnetohydrodynamics (MHD) solver on a GTX 480 Graphics Processing Unit (GPU). Taking a simple approach in which the MHD variables are stored exclusively in the global memory of the GTX 480 and accessed in a cache-friendly manner (without further optimizing memory access by, for example, staging data in the GPU's faster shared memory), we achieved a maximum speed-up of approx. = 126 for a sq 1024 grid relative to the sequential C code running on a single Intel Nehalem (2.8 GHz) core. This speedup is consistent with simple estimates based on the known floating point performance, memory throughput and parallel processing capacity of the GTX 480.

graphics processing units↗

Load Bearing Equipment for Bone and Muscle Project

Axial skeletal loads coupled with muscle torque forces around joints maintain bone. Astronauts working in pairs to exercise can provide high eccentric loads for each other that are most effective. A prototype of load bearing equipment that will allow astronauts to perform exercises using each other for counter force generation in a controlled fashion and provide eccentric overload is proposed. A frame and attachments that can be rapidly assembled for use and easily stored will demonstrate feasibility of a design that can be adapted for ISS testing and Orion use.

Terrier, Douglas↗

Load Bearing Equipment for Bone and Muscle

Resistance exercise on ISS has proven effective in maintaining bone mineral density and muscle mass. Exploration missions require exercise with similar high loads using equipment with less mass and volume and greater safety and reliability than resistance exercise equipment used on ISS (iRED, ARED, FWED). Load Bearing Equipment (LBE) uses each exercising person to create and control the load to the partner.

Shackelford, Linda↗

NIAC Phase I Study Final Report on Large Ultra-Lightweight Photonic Muscle Space Structures

The research goal is to develop new tools support NASA's mission of understanding of the Cosmos by developing cost effective solutions that yield a leap in performance and science data. 'Maikalani' in Hawaiian translates to, "knowledge we gain from the cosmos." Missions like Hubble have fundamentally changed humanity's view of the cosmos. Last year's Nobel prize in physics was a result of astronomical discoveries. $9B class JWST size (6.5 meter diameter) space telescopes, when launched are anticipated to rewrite our knowledge of physics. Here we report on a neoteric meta-material telescope mirror technology designed to enable a factor of 100 or more reduction in areal density, a factor of 100 reduction in telescope production and launch costs as well as other advantages; a leap to enable missions to image the cosmos in unprecedented detail, with the associated gain in knowledge. Whether terahertz, visible or X-ray, reflectors used for high quality electromagnetic imaging require shape accuracy (surface figure) to far better than 1 wavelength (lambda) of the incident photons, more typically lambda/10 or better. Imaging visible light therefore requires mirror surfaces that approximate a desired curve (e.g. a sphere or paraboloid) with smooth shape deviation of th less than approximately 1/1000 the diameter of a human hair. This requires either thick high modulus material like glass or metal, or actuators to control mirror shape. During Phase I our team studied a novel solution to this systems level design mass/shape tradespace requirement both to advance the innovative space technology concept and also to help NASA and other agencies meet current operational and future mission requirements. Extreme and revolutionary NASA imaging missions such as Terrestrial Planet Imager (TPI) require lightweight mirrors with minimum diameters of 20 to 40 meters. For reference, NASA's great achievement; the Hubble space telescope, is only 2.4 meters in diameter. What is required is a way to make large inexpensive deployable mirrors where the cost is measured in millions, not billions like current efforts. For example we seek an interim goal within 10 years of a Hubble size (2.4m) primary mirror weighing 1 pound at a cost of 10K in materials. Described here is a technology using thin ultra lightweight materials where shape can be controlled simply with a beam of light, allowing imaging with incredibly low mass yet precisely shaped mirrors. These " Photonic Muscle" substrates will eventually make precision control of giant s p a c e apertures (mirrors) possible. OCCAM substrates make precision control of giant ultra light-weight mirror apertures possible. This technology is posed to create a revolution in remote sensing by making large ultra lightweight space telescopes a fiscal and material reality over the next decade.

Cosmos↗

Electroactive polymers as artificial muscles - reality and challenges

For many years, electroactive polymers (EAP) received reIatively little attention due to the small number of available materials and their limited actuation capability. The recent emergence of EAP materials with large displacement response changed the potential capability and paradigms of these materials. The main attractive characteristic of EAP is their operational similarity to biological muscles, particularly their resilience and ability to induce large actuation strains. Even though the actuation force of existing EAP materials and their robustness require further improvement, there has already been a series of reported successes. The successful applications that were demonstrated include catheter steering element, miniature manipulator, dust-wiper, miniature robotic arm, and grippers. Some of the currently considered applications may be difficult to accomplish and it is important to scope the requirements to the level that current materials can address. Using EAP to replace existing actuators may be a difficult challenge and therefore it is highly desirable to identify a niche application where it would not need to compete with existing capabilities. The application of these materials as actuators to drive various manipulation, mobility and robotic devices involves multidiscipline including materials, chemistry, electro-mechanics, computers, electronics, etc. This paper reviews the current efforts and the expectations for the future.

Bar-Cohen, Yoseph↗

Electroactive Polymers (EAP) low Mass Muscle Actuators

Actuation devices are used for many space applications with an increasing need to reduce their size, mass, and power consumption as well as cut their cost. Existing transducing actuators, such as piezoceramics, induce limited displacement levels. Potentially, electroactive polymers (EAP) have the potential for low-mass, low-power, inexpensive miniature muscle actuators that are superior to the widely used actuators.

Electroactive↗