Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MHZ RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Ultrasonic evaluation of mechanical properties of thick, multilayered, filament wound composites

A preliminary investigation is conducted to define capabilities and limitations of ultrasonic and acousto-ultrasonic measurements related to mechanical properties of filament wound graphite/epoxy composite structures. The structures studied are segments of filament wound cylinders formed of multiple layers of hoop and helical windings. The segments consist of 24 to 35 layers and range from 3.02 to 3.34 cm in wall thickness. The resultant structures are anisotropic, heterogeneous, porous, and highly attenuating to ultrasonic frequencies greater than 1 MHz. The segments represent structures to be used for space shuttle booster cases. Ultrasonic velocity and acousto-ultrasonic stress wave factor measurement approaches are discussed. Correlations among velocity, density, and porosity, and between the acousto-ultrasonic stress wave factor and interlaminar shear strength are presented.

Kautz, H. E.↗

The 50-MHz meteor radar observation at Syowa Station, Antarctica

The 50-MHz Doppler radar installed at Syowa Station (69 deg 00'S, 39 deg 35'E), Antarctica, in 1982 can detect continuously a meteor echo if an operator assigns the meteor mode operation to the radar. The radar has two narrow antenna beams (4 deg in the horizontal plane), one toward geomagnetic south and the other toward approximately geographic south, with a crossing angle of about 33 deg. The minicomputer annexed to the radar controls the transmission and reception of a 50-MHz wave. If the receiver detects a meteor echo, the flag signal is sent to the computer. Then the computer begins to determine the echo range with a time resolution of 1 micro s and to sample every 200 microns/s for 1 s the Doppler signal and echo intensity at the particular range (R). The line-of-sight velocity (V sub D) of the echo trail is calculated from the output from the Doppler signal detection circuit having an offset frequency by using the so-called zero-crossing method. The echo amplitude decay time calculated by a least-mean square method is used to obtain the ambipolar diffusion coefficient (D) and then to calculate the echo height (H). About 120 day observations were made during 1982-1983. Some early results are presented. magnetic tapes together with V sub D, D, H and R for later analysis in Japan. About 120 day observation were made during 1982-1983. Some early results are presented.

Tanaka, T.↗

Ultrasonic evaluation of mechanical properties of thick, multilayered, filament-wound composites

A preliminary investigation is conducted to define capabilities and limitations of ultrasonic and acousto-ultrasonic measurements related to mechanical properties of filament wound graphite/epoxy composite structures. The structures studied are segments of filament wound cylinders formed of multiple layers of hoop and helical windings. The segments consist of 24 to 35 layers and range from 3.02 to 3.34 cm in wall thickness. The resultant structures are anisotropic, heterogeneous, porous, and highly attenuating to ultrasonic frequencies greater than 1 MHz. The segments represent structures to be used for Space Shuttle booster cases.Ultrasonic velocity and acousto-ultrasonic stress wave factor measurement approaches are discussed. Correlations among velocity, density, and porosity, and between the acousto-ultrasonic stress wave factor and interlaminar shear strength are presented.

Kautz, H. E.↗

Millimeter-wave detection using resonant tunnelling diodes

A lattice-matched InGaAs/InAlAs resonant tunnelling diode is studied as a video detector in the millimeter-wave range. Tangential signal sensitivity and video resistance measurements are made as a function of bias and frequency. A tangential signal sensitivity of -37 dBm (1 MHz amplifier bandwidth) with a corresponding video resistance of 350 ohms at 40 GHz has been measured. These results appear to be the first millimeter-wave tangential signal sensitivity and video resistance results for a resonant tunnelling diode.

Mehdi, I.↗

AlGaAs/GaAs quasi-bulk effect mixers: Analysis and experiments

The lowest noise temperature for any receiver in the 0.5 to 1 THz range has been achieved with the bulk InSb hot electron mixer, which unfortunately suffers from the problem of having a very narrow bandwidth (1-2 MHz). We have demonstrated a three order of magnitude improvement in the bandwidth of hot electron mixers, by using the two-dimensional electron gas (2DEG) medium at the hetero-interface between AlGaAs and GaAs. We have tested both inhouse MOCVD-grown material, and MBE materials, with similar results. The conversion loss (L(sub c)) at 94 GHz is presently 18 dB for a mixer operating at 20 K, and calculations indicate that L(sub c) can be decreased to about 10 dB in future devices. Calculated and measured curves of L(sub c), versus PLO and IDC, respectively, agree well. We argue that there are several different configurations of hot electron mixers, which will also show wide bandwidth, and that these devices are likely to become important as low-noise THz receivers in the future.

Yngvesson, K. S.↗

Recent Outbursts from the Transient X-Ray Pulsar Cepheus X-4 (GS 2138 + 56)

We report on X-ray observations of the 66 s period transient X-ray pulsar Cep X-4 (GS 2138+56) with the Burst and Transient Source Experiment (BATSE) on the Compton Gamma Ray Observatory and with the Rossi X-Ray Timing Explorer (RXTE). Two outbursts from Cep X-4 were observed with BATSE in 1993 June-July and in 1997 July. Pulse frequencies of v = 15.0941 + or - 0.0002 mHz on 1993 June 25 (MJD 49,163) and v = 15.0882 + or - 0.0002 mHz on 1997 July 12 (MJD 50,641) were each measured from 2-day spans of BATSE data near each outburst's peak. Cep X-4 showed an average spin down rate of dot-v = (-4.14 + or - 0.08) x 10(exp -14) Hz s(exp -1) between the 1993 and 1997 outbursts. After BATSE could no longer detect Cep X-4, public observations were performed on 1997 July 18 and July 25 with the Proportional Counter Array (PCA) on RXTE. A pulse frequency of v = 15.088 + or - 0.004 mHz was measured from observations on 1997 July 18 (MJD 50,647). Significant aperiodic noise, with an rms variance of about 18% in the frequency range 0.01 - 1.0 Hz, was observed on both days. Energy- and intensity-dependent pulse shape variations were also seen in these data. Recently published optical observations associate Cep X-4 with a Be companion star. If all four outbursts observed from Cep X-4 are assumed to occur at the same orbital phase, we find that the orbital period is between 23 and 147.3 days.

Wilson, Colleen A.↗

Magnetic triggering — time-resolved characterisation of silicon strip modules in the presence of switching DC-DC converters

Modules for the ATLAS Inner Tracker (ITk) strip tracker include a DC-DC converter circuit glued directly to the silicon sensor which converts the 11 V supplied to the module to the 1.5 V required for the operation of the readout chips. The DC-DC converter unit, consisting of a copper solenoid and custom ASIC, is located directly above the silicon strip sensor and therefore needs to be shielded to protect the sensor from EMI noise created during the operation of the circuit. Despite dedicated shielding, consisting of an aluminium shield box with continuous solder seams encompassing the surface components and a copper layer in the PCB beneath it, module channels connected to sensor strips located beneath the converter circuit were found to show a noise increase. While the DC-DC converter unit causing the underlying EMI noise operates at a frequency of 2 MHz, module characterisation measurements for ITk strip tracker modules are typically performed asynchronously to the DC-DC switching and are therefore averaged over the full range of time bins with respect to the converter frequency. In order to investigate the time dependence of the noise injection relative to the DC-DC switching frequency, a dedicated setup to understand the time-resolved performance change in modules was developed. By using a magnetic field probe to measure the field leaking through the shield box and triggering on its rising edge, data taking could be synchronised with the DC-DC switching. This paper illustrates the concept and setup of such time-resolved performance measurements using magnetic triggering and presents results for the observed effects on signal and noise for ATLAS ITk strip modules from both laboratory and beam tests.

47 OTHER INSTRUMENTATION↗

Longwave infrared (6.6–11.4 µm) dual-comb spectroscopy with 240,000 comb-mode-resolved data points at video rate

Using sub-3-cycle pulses from mode-locked Cr:ZnS lasers at λ ≈ 2.4 µm as a driving source, we performed high-resolution dual-frequency-comb spectroscopy in the longwave infrared (LWIR) range. A duo of highly coherent broadband (6.6–11.4 µm) frequency combs were produced via intrapulse difference frequency generation in zinc germanium phosphide (ZGP) crystals. Fast (up to 0.1 s per spectrum) acquisition of 240,000 comb-mode-resolved data points, spaced by 80 MHz and referenced to a Rb clock, was demonstrated, resulting in metrology grade molecular spectra of N 2 O (nitrous oxide) and CH 3 OH (methane). The key to high-speed massive spectral data acquisition was low intensity and phase noise of the LWIR combs and high (7.5%) downconversion efficiency, resulting in a LWIR power of 300 mW for each comb.

Vasilyev, Sergey (ORCID:0000000225203547)↗

Spacecraft-spacecraft very long baseline interferometry for planetary approach navigation

The study presents an error budget for Delta differential one-way range (Delta-DOR) measurements between two spacecraft. Such observations, made between a planetary orbiter (or lander) and another spacecraft approaching that planet, would provide a powerful target-relative angular tracking data type for approach navigation. Accuracies of about 5 nrad should be possible for a pair of X-band spacecraft incorporating 40-MHz DOR tone spacings, while accuracies approaching 1 nrad will be possible if the spacecraft incorporate Ka-band downlinks with DOR tone spacings of order 250 MHz. Operational advantages of this data type are discussed, and ground system requirements needed to enable S/C-S/C Delta-DOR observations are outlined. A covariance analysis is presented to examine the potential navigation improvement for this scenario. The results show factors of 2-3 improvement in spacecraft targeting over conventional Doppler, range, and quasar-relative VLBI, along with reduced sensitivity to ephemeris uncertainty and other systematic errors.

Edwards, Charles D., Jr.↗

Cryogenic Behavior of the High Temperature Crystal Oscillator PX-570

Microprocessors, data-acquisition systems, and electronic controllers usually require timing signals for proper and accurate operation. These signals are, in most cases, provided by circuits that utilize crystal oscillators due to availability, cost, ease of operation, and accuracy. Stability of these oscillators, i.e. crystal characteristics, is usually governed, amongst other things, by the ambient temperature. Operation of these devices under extreme temperatures requires, therefore, the implementation of some temperature-compensation mechanism either through the manufacturing process of the oscillator part or in the design of the circuit to maintain stability as well as accuracy. NASA future missions into deep space and planetary exploration necessitate operation of electronic instruments and systems in environments where extreme temperatures along with wide-range thermal swings are countered. Most of the commercial devices are very limited in terms of their specified operational temperature while very few custom-made and military-grade parts have the ability to operate in a slightly wider range of temperature. Thus, it is becomes mandatory to design and develop circuits that are capable of operation efficiently and reliably under the space harsh conditions. This report presents the results obtained on the evaluation of a new (COTS) commercial-off-the-shelf crystal oscillator under extreme temperatures. The device selected for evaluation comprised of a 10 MHz, PX-570-series crystal oscillator. This type of device was recently introduced by Vectron International and is designed as high temperature oscillator [1]. These parts are fabricated using proprietary manufacturing processes designed specifically for high temperature and harsh environment applications [1]. The oscillators have a wide continuous operating temperature range; making them ideal for use in military and aerospace industry, industrial process control, geophysical fields, avionics, and engine control. They exhibit low jitter and phase noise, consume little power, and are suited for high shock and vibration applications. The unique package design of these crystal oscillators offers a small ceramic package footprint, as well as providing both through-hole mounting and surface mount options.

Patterson, Richard↗

The Clark Lake array.

A fully steerable array of 720 conical log spiral antennas nearing completion in southern California is described. It is capable of operation at any frequency between 15 and 130 MHz an instantaneous bandwidth of 3 MHz. The array is a pencil-beam instrument with a beam width proportional to the wavelength; it varies from 3 to 27 feet across the frequency range. It will soon be available for both solar and sidereal studies.

Erickson, W. C.↗

Characteristics of magnetospheric radio noise spectra

Magnetospheric radio noise spectra (30 kHz to 10 MHz) taken by IMP-6 and RAE-2 exhibit time-varying characteristics which are related to spacecraft position and magnetospheric processes. In the mid-frequency range (100-1,000 kHz) intense noise peaks rise by a factor of 100 or more above background; 80% of the peak frequencies are within the band 125 kHz to 600 kHz, and the peak occurs most often (18% of the time) at 280 kHz. This intense mid-frequency noise has been detected at radial distances from 1.3 Re to 60 Re on all sides of the Earth during magnetically quiet as well as disturbed periods. Maximum occurrence of the mid-frequency noise is in the evening to midnight hours where splash-type energetic particle precipitation takes place. ""Magnetospheric lightning'' can be invoked to explain the spectral shape of the observed spectra.

Herman, J. R.↗

Improved Dielectric Properties of Heterostructured Ba2.5Sr0.5TiO3 Thin Film Composites for Microwave Dielectric Devices

In the present work we have deposited MgO and Ba(sub 0.5)Sr(sub 0.5)TiO(sub 3)(BST50) thin layers in different sequences to make MgO:BST50 hetero-structured thin films. These films were characterized by X-ray diffraction and Rutherford backscattering technique and found to be highly (100) textured. The figure of merit {(C(sub0)-C(sub v)/(C(sub0-tandelta)} of the hetero-structured films was found to be higher as compared to pure BST50 films measured at 1 MHz frequency with electric field of 25.3 kV/cm. These films were used to make eight element coupled micro-strip phase shifter and characterized in a frequency range of 13-15 GHz. The high frequency figure of merit (kappa factor, defined as the ratio of degree of phase shift per dB loss) measured at around 14 GHz with electric field of 333 kV/cm has been markedly improved (around 64.28 deg/dB for hetero-structured film as compared to 24.65 deg /dB for pure film). Improvement in dielectric properties in a wide frequency range in the MgO:BST are believed to be due to the higher densification of the hetero-structured films.

Jain, M.↗

Ultrasonic Studies of Composites Undergoing Thermal and Fatigue Loading

New composite materials possess attractive properties for use in advanced aircraft. A necessary requirement for their introduction into aeronautic use is an accurate understanding of their long term aging processes so that proper design criteria can be established. In order to understand those properties, these composites must be exposed to thermal and load cycles that are characteristic of flight conditions. Additionally, airline companies will require nondestructive evaluation (NDE) methods that can be used in the field to assess the condition of these new materials as they age. As part of an effort to obtain the required information about new composites for aviation use, we are performing ultrasonic measurements both in the NDE laboratory and in the materials testing laboratory at NASA. The materials testing laboratory is equipped with environmental chambers mounted on load frames so that composite samples can be exposed to thermal and loading cycles representative of flight protocols. Applying both temperature and load simultaneously will help to highlight temperature and load interactions during the aging of these composite materials. This study reports on our initial ultrasonic attenuation results from thermoset and thermoplastic composite samples. Ultrasonic attenuation measurements have been used reliably to assess the effects of material degradation. For example, recently, researchers have shown that by using frequencies of ultrasound on the order of 24 MHz, they could obtain adequate contrast in the evaluation of thermal degradation in these composites. This paper will present data that shows results at a lower frequency range. In addition, we report results on the frequency dependence of attenuation as the slope of attenuation with respect to frequency, beta = delta alpha (f) / delta f. The slope of attenuation is an attractive parameter since it is quantitative, yet does not require interface corrections like conventional quantitative attenuation measurements. This is a consequence of the assumption that interface correction terms are frequently independent. Uncertainty in those corrections terms compromises the value of conventional quantitative attenuation data.

Madaras, Eric I.↗

Investigation of coronal holes in the radio and far-ultraviolet ranges

Results of coronal-hole observations carried out in the far-UV with a spectro-heliometer aboard Skylab are compared with corresponding results of ground-based radioheliograph measurements performed at frequencies of 80 and 160 MHz. It is found that the electron density derived from the far-UV observations for the transition region and lower corona is nearly three times greater than the value computed on the basis of the radio data. Unsuccessful attempts are made to eliminate this discrepancy by recalibrating the radio data and by recalculating the ionization equilibrium. A substantial local enhancement of the heavy-element abundance in certain parts of the transition region and inner chromosphere is considered as a possible cause of the discrepancy.

Sheridan, K. V.↗

Optimizing ensemble NV − spin properties of fluorescent diamond microparticles by systematic low pressure high temperature annealing

Low pressure high temperature annealing is a means for driving nitrogen and defect diffusion in diamond to reduce internal lattice damage without the need for technically complicated high-pressure cells. Herein, we perform a systematic time (5, 15, and 30 min) and temperature (1200 °C–1800 °C) study of effects of low-pressure high temperature annealing on photoluminescence, spin concentrations, and spin relaxation properties of NV centers in ca. 3 μm synthetic type 1b diamond particles. Annealing in the temperature range of ca. 1400 °C–1700 °C for even 5 min leads to a higher optically detected magnetic resonance contrast as compared to standard annealing at 900 °C for 2 h. Particles annealed at 1700 °C for 5 min exhibit a contrast close to about 13% as compared to about 9% for those annealed at 900 °C for 2 h. A reduction in the zero-field splitting strain parameter from E ≈ 4.5 MHz to ≈ 2.5 MHz and spectral linewidth from Δν ≈ 7 MHz to ≈ 4 MHz are observed even after 5 min annealing at 1700 °C. Improvements in these spectral parameters resulted in a roughly 2-fold reduction in the noise level of temperature monitoring experiment utilizing an ensemble of NV centers in the particles. Annealing in the temperature range of 1600 °C for 15 or 30 min or 1700 °C for 5 min resulted in NV T 1 relaxation times approaching ca. 5 ms typically observed for bulk diamond. Quantitative electron paramagnetic resonance (EPR) allowed for estimations of thermal activation energies of paramagnetic center annihilation. Monitoring the primary defect concentration (P1 and other defects with half integer spins) and utilizing second order kinetic modeling, an activation energy of 3.63 ± 0.28 eV was estimated. Alternatively, using the NV half field EPR signal and first order kinetic modeling, a similar activation energy 3.89 ± 0.29 eV was estimated.

NV centers↗

Decimetric gyrosynchrotron emission during a solar flare

A decimetric, microwave, and hard X-ray burst was observed during a solar flare in which the radio spectrum below peak flux fits an f+2 power law over more than a decade in frequency. The spectrum is interpreted to mean that the radio emission originated in a homogeneous, thermal, gyrosynchrotron source. This is the first time that gyrosynchrotron radiation has been identified at such low decimetric frequencies (900-998) MHz). The radio emission was cotemporal with the largest single hard X-ray spike burst ever reported. The spectrum of the hard X-ray burst can be well represented by a thermal bremsstrahlung function over the energy range from 30 to 463 keV at the time of maximum flux. The temporal coincidence and thermal form of both the X-ray and radio spectra suggest a common source electron distribution. The unusual low-frequency extent of the single-temperature thermal radio spectrum and its association with the hard X-ray burst imply that the source had an area approx. 10(18) sq cm a temperature approx 5x10(8) K, an electron density approx. 7.10(9) cu cm and a magnetic field of approx. 120 G. H(alpha) and 400-800 MHz evidence suggest that a loop structure of length 10,000 km existed in the flare active region which could have been the common, thermal source of the observed impulsive emissions.

Batchelor, D. A.↗

A Field-Enhanced Conduction-Cooled Superconducting Cavity for High-Repetition-Rate Ultrafast Electron Bunch Generation

High-repetition-rate sources of bright electron bunches have a wide range of applications. They can directly be employed as probes in electron-scattering setups, or serve as a backbone for the generation of radiation over a broad range of the electromagnetic spectrum. This paper describes the development of a compact sub-Mega-electronvolt (sub-MeV) electron-source setup capable of operating at MHz repetition rates and forming sub-picosecond electron bunches with transverse emittance below 20 nm. The setup relies on a conduction-cooled superconducting single-cell resonator with its geometry altered to enhance the field at the surface of the emitter. The system is designed to accommodate cooling using a 2 W pulse-tube cryogen-free cryocooler operated at 4.2 K. Although we focus on the case of a photoemitted electron bunch, the scheme could be adapted to other emission mechanisms.

43 PARTICLE ACCELERATORS↗