Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC FIELD COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

US HL-LHC Accelerator Upgrade Project (MQXFA Final Design Report)

The MQXFA Quadrupole magnets will be installed in High Luminosity LHC to form the Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS). A pair of MQXFA units is assembled in a stainless steel helium vessel, including the end domes, to make the Q1 Cold Mass or the Q3 Cold Mass. The US HL LHC Accelerator Upgrade Project* is responsible for the design, manufacturing and test of the Q1/Q3 Cold Masses and the complete MQXFA magnets. CERN provides the cryostat components and is responsible for integration and installation in HL LHC. The MQXFA quadrupoles have 150 mm aperture, 4.2 m magnetic length, nominal gradient of 132.2 T/m, and coil peak field of 11.3 T. They use Nb_3Sn conductor and a support structure made of segmented aluminum shells pre-loaded by using bladders and keys. This report presents the final design of the MQXFA quadrupole magnets.

43 PARTICLE ACCELERATORS↗

Generalized theory of double-resonance optical pumping of {sup 4}He

We present extensions to the theory of double-resonance laser pumping of {sup 4}He in the context of magnetometer instrumentation. This extended theory allows for arbitrary optical polarization, magnetic resonance (H{sub 1}) coil orientation, and overall instrument orientation relative to the ambient magnetic field. Steady-state solutions are presented for portions of the extended parameter space. These calculations are used to analyze the shot-noise-limited sensitivities for helium magnetometers for selected parameter values, and we find that linearly polarized light can have a relatively simple orientational dependence for a particular choice of angle between the H{sub 1} coils and the light polarization vector. Calculations are also compared to experimentally measured magnetic resonance curves, and a shot-noise limit on sensitivity of 6 fT/{radical}(Hz) is determined for a particular magnetometer apparatus using a cell 2.4 cm in diameter and 7.5 cm in length. This extended theory can be utilized to select optimal operational parameter values and obtain ideal sensitivities for helium magnetometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flightweight Electro-Magnet Systems

NASA has a need for lightweight high performance magnets to be used in propulsion systems involving plasmas. We report the design, construction, and testing of a six inch diameter by twelve inch long solenoid using high purity aluminum wire operating at a temperature of 77 Kelvin (K) for the current carrying element. High purity aluminum is the material of choice because of three properties that make it optimal for magnetic construction. At 77 K high purity aluminum has one of the lowest resistivities at 77 K of any metal (p = 0.254 muOMEGA-cm), thus reducing the power requirements for creating magnetic fields. Aluminum is a low-density (2.6989 g/cc) material and the end product magnet will be of low total mass compared to similar designs involving copper or other elements. The magneto-resistance of aluminum saturates at low magnetic fields and does not increase indefinitely as is the case in copper. The magnet consists of four layers of closely wound wire and is approximately 150 mm in diameter by 300 mm long. A cylinder made from G - 10 was machined with a spiral groove to hold the high purity Al wire and the wire wound on it. Following the winding, each layer was potted in STYCAST high thermal conductivity epoxy to provide insulation between the turns of the coil and mechanical strength. The magneto-resistance of the coil has been measured at the National High Magnetic Field Laboratory (NHMFL), Tallahassee, FL in externally applied fields to 10 tesla. Following these tests it was energized to the full 2 tesla field it can produce using the facilities of the NHMFL at the Los Alamos National Laboratory. The results of all of these tests will be presented.

Goodrich, Roy G.↗

Development of fast cooling pulsed magnets at the Wuhan National High Magnetic Field Center

Pulsed magnets with fast cooling channels have been developed at the Wuhan National High Magnetic Field Center. Between the inner and outer sections of a coil wound with a continuous length of CuNb wire, G10 rods with cross section 4 mm × 5 mm were inserted as spacers around the entire circumference, parallel to the coil axis. The free space between adjacent rods is 6 mm. The liquid nitrogen flows freely in the channels between these rods, and in the direction perpendicular to the rods through grooves provided in the rods. For a typical 60 T pulsed magnetic field with pulse duration of 40 ms, the cooling time between subsequent pulses is reduced from 160 min to 35 min. Subsequently, the same technology was applied to a 50 T magnet with 300 ms pulse duration. The cooling time of this magnet was reduced from 480 min to 65 min.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanical Design of the Interaction Region Dipole B1pF for Electron Ion Collider

Here, the Electron-Ion Collider (EIC), planned for construction at Brookhaven National Laboratory, will consist of two intersecting beams of intense electrons and high-energy protons or heavier atomic nuclei. The collider will need many demanding components, including high field superconducting magnets for the Interaction Region (IR). It has been decided that a prototype of one such magnet, the B1pF dipole, shall be built, to validate design choices common to all Rutherford cable dipole and quadrupole IR magnets. B1pF is one of several high field magnets in the interaction region whose design is based on the 15.1 mm wide NbTi cable, a cable like the one used in the main dipole coil of the Large Hadron Collider (LHC) at CERN. The current design is based on a single layer coil with an inner diameter of 300 mm and magnetic length of ~3 m which generates a magnetic field at the center of the magnet of about 3.7 T at a current of ~11 kA at design. This paper presents the mechanical design of the B1pF dipole magnet, and the R&D effort associated with the development of the prototype, including tests for successfully winding and curing coils of the needed configuration into proper structural and magnetic elements, and including a multilayer magnetic return yoke which meets field requirements while providing an initial reduced structure suitable for operational testing in an existing test facility.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic Compensation for Second-Order Doppler Shift in LITS

The uncertainty in the frequency of a linear-ion-trap frequency standard (LITS) can be reduced substantially by use of a very small magnetic inhomogeneity tailored to compensate for the residual second-order Doppler shift. An effect associated with the relativistic time dilatation, one cause of the second-order Doppler shift, is ion motion that is attributable to the trapping radio-frequency (RF)electromagnetic field used to trap ions. The second-order Doppler shift is reduced by using a multi-pole trap; however it is still the largest source of systematic frequency shift in the latest generation of LITSs, which are among the most stable clocks in the world. The present compensation scheme reduces the frequency instability of the affected LITS to about a tenth of its previous value. The basic principles of prior generation LITSs were discussed in several prior NASA Tech Briefs articles. Below are recapitulated only those items of basic information necessary to place the present development in context. A LITS includes a microwave local oscillator, the frequency of which is stabilized by comparison with the frequency of the ground state hyperfine transition of 199Hg+ ions. The comparison involves a combination of optical and microwave excitation and interrogation of the ions in a linear ion trap in the presence of a nominally uniform magnetic field. In the current version of the LITS, there are two connected traps (see figure): (1) a quadrupole trap wherein the optical excitation and measurement take place and (2) a 12-pole trap (denoted the resonance trap), wherein the microwave interrogation takes place. The ions are initially loaded into the quadrupole trap and are thereafter shuttled between the two traps. Shuttling ions into the resonance trap allows sensitive microwave interrogation to take place well away from loading interference. The axial magnetic field for the resonance trap is generated by an electric current in a finely wound wire coil surrounded by magnetic shields. In the quadrupole and 12-pole traps, the potentials are produced by RF voltages applied to even numbers (4 and 12, respectively) of parallel rods equally spaced around a circle. The polarity of the voltage on each rod is opposite that of the voltage on the adjacent rod. As a result, the amplitude of the RF trapping field is zero along the centerline and increases, with radius, to a maximum value near the rods.

Burt, Eric↗

Sensitivity of the magnetic axis to variations in the magnetic field

Lagrangian variational principles are used to locate the magnetic axis and to determine its sensitivity to variations in the magnetic field. Only the change in the magnetic field on axis is required to determine, to lowest order, the location of the new magnetic axis. Using a simple example, namely, the magnetic field produced by a set of current-carrying filaments (a.k.a. coils), the variation in the coil geometry that induces the largest change in the magnetic axis is determined using singular value decomposition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication and test of model superconducting inflector for g-2 at FNAL

The new FNAL g-2 experiment is based on the muon storage ring previously used at BNL. The 1.45 T dipole magnetic field in the storage ring is required to have very high (1 ppm) homogeneity. The muon beam injected into the ring must be transported through the magnet yoke and the main superconducting coil cryostat with minimal distortions. The old inflector magnet shielded the main dipole fringe field inside the muon transport beam pipe, with an outer NbTi superconducting screen, and did not disturb the field in the area of circulating beam. Nevertheless, this magnet had coils with closed ends in which a large fraction of muon beam particles were lost. A new magnet is envisioned utilizing the same cross section as the original with open ends for improved beam transport. A model magnet has been wound utilizing 3d printed parts to verify the magnetic behavior of the magnet at room temperature and validate winding of the complicated geometry required for the magnet ends. Finally, room temperature magnetic measurements have been performed and confirm the magnetic design

43 PARTICLE ACCELERATORS↗

Performance of a MQXF Nb 3 Sn Quadrupole Magnet Under Different Stress Level

In a dipole or in a quadrupole accelerator magnet, the displacement of the coil turns induced by the electromagnetic forces can cause quenches limiting the magnet performance. For this reason, an azimuthal preload is applied to avoid azimuthal movements of the coil up to the required operational current. However, several tests showed that accelerator magnets can operate with a partial preload, i.e. that coil unloading during the ramp does not prevent reaching higher currents. This issue is particularly relevant for Nb 3 Sn magnets, where the loads applied to the Nb3Sn filaments can reach the degradation limits of critical current. In order to investigate the impact of coil preload on the quench performance, the MQXFS6 short model quadrupole for the High Luminosity Upgrade was tested under an azimuthal preload at 80% of the short sample current, reaching 93% of short sample current at 1.9 K. The preload was then released to 60%, still showing ability to operate in the range of 80-85% of short sample current as required by HL-LHC project. With this lower preload, the ability of going above 90% of short sample was lost, and a significant training appeared above 85%. When the preload was restored to the original 80% value, the magnet reached with few quenches 95% of short sample (13.4 T peak field). Magnetic measurements confirm the larger movement of the coil in the case with lower preload, and agree with finite element simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conceptual Design of a HTS Dipole Insert Based on Bi2212 Rutherford Cable

The U.S. Magnet Development Program (US-MDP) is aimed at developing high-field accelerator magnets with magnetic fields beyond the limits of Nb 3 Sn technology. Recent progress with composite wires and Rutherford cables based on the first generation high-temperature superconductor Bi 2 Sr 2 CaCu 2 O 8-x (Bi2212) allows considering them for this purpose. However, Bi2212 wires and cables are sensitive to transverse stresses and strains, which are large in high-field accelerator magnets. This requires magnet designs with stress management concepts to control azimuthal and radial strains in the coil windings and prevent the degradation of the current carrying capability of Bi2212 conductor or even its permanent damage. This paper describes a novel stress management approach, which was developed at Fermilab for high-field large-aperture Nb 3 Sn accelerator magnets, and is now being applied to high-field dipole inserts based on Bi2212 Rutherford cables. The insert conceptual design and main parameters, including the superconducting wire and cable, as well as the coil stress management structure, key technological steps and approaches, test configurations and their target parameters, are presented and discussed.

43 PARTICLE ACCELERATORS↗

A tetrahedral probe constellation approach for measuring canonical momentum in self-organized laboratory plasma

To examine momentum redistribution processes and study generalized helicities during plasma relaxation in Madison Symmetric Torus, MST, reversed field pinch plasma, a new probe is being tested to measure the full 3D plasma ion flow and magnetic field vectors at four spatial locations arranged in a tetrahedral shape reminiscent of a satellite measurement constellation. These measurements permit calculation of ∇ x $\vec{u}$ and canonical momentum, where $\vec{u}$ is the plasma ion flow vector. The probe consists of four probe heads arranged in a tetrahedral pattern, with an overall probe diameter of ∼31.75 mm. The probe head diameter is ∼1.0 cm, which is of the order of the ion Larmor radius. Each head has four molybdenum electrodes, also arranged in tetrahedral geometry, which are biased relative to a common return electrode, using four power supplies (one for each head), to measure the local ion flow. Additionally, each head has three orthogonal magnetic pickup coils within it to measure equilibrium and fluctuating magnetic fields.

Physics - Plasma physics↗

Goddard Space Flight Center Spacecraft Magnetic Test Facility Restoration Project

The Goddard Space Flight Center Spacecraft Magnetic Test Facility (SMTF) was constructed in the 1960's for the purpose of simulating geomagnetic and interplanetary magnetic field environments. The facility includes a three axis Braunbek coil system consisting of 12 loops, 4 loops on each of the three orthogonal axes; a remote earth field sensing magnetometer and servo control building; and a remote power control and instrumentation building. The inner coils are 42-foot in diameter and a 10-foot by 10-foot opening through the outer coils accommodates spacecraft access to the test volume. The physical size and precision of the facility are matched by only two other such facilities in the world. The facility was used extensively from the late 1960's until the early 1990's when the requirement for spacecraft level testing diminished. New NASA missions planned under the Living with a Star, Solar Terrestrial Probes, Explorer, and New Millennium Programs include precision, high-resolution magnetometers to obtain magnetic field data that is critical to fulfilling their scientific mission. It is highly likely that future Lunar and Martian exploration missions will also use precision magnetometers to conduct geophysical magnetic surveys. To ensure the success of these missions ground testing using a magnetic test facility such as the GSFC SMTF will be required. This paper describes the history of the facility, the future mission requirements that have renewed the need for spacecraft level magnetic testing, and the plans for restoring the facility to be capable of performing to its original design specifications.

Vernier, Robert↗

Runaway electron deconfinement in SPARC and DIII-D by a passive 3D coil

The operation of a 3D coil—passively driven by the current quench (CQ) loop voltage—for the deconfinement of runaway electrons (REs) is modeled for disruption scenarios in the SPARC and DIII-D tokamaks. Nonlinear magnetohydrodynamic (MHD) modeling is carried out with the NIMROD code including time-dependent magnetic field boundary conditions to simulate the effect of the coil. Further modeling in some cases uses the ASCOT5 code to calculate advection and diffusion coefficients for REs based on the NIMROD-calculated fields, and the DREAM code to compute the runaway evolution in the presence of these transport coefficients. Compared with similar modeling in Tinguely et al (2021 Nucl. Fusion 61 124003), considerably more conservative assumptions are made with the ASCOT5 results, zeroing low levels of transport, particularly in regions in which closed flux surfaces have reformed. Of three coil geometries considered in SPARC, only the n = 1 coil is found to have sufficient resonant components to suppress the runaway current growth. Without the new conservative transport assumptions, full suppression of the RE current is maintained when the thermal quench MHD is included in the simulation or when the RE current is limited to 250kA, but when transport in closed flux regions is fully suppressed, these scenarios allow RE beams on the order of 1–2 MA to appear. Additional modeling is performed to consider the effects of the close ideal wall. In DIII-D, the CQ is modeled for both limited and diverted equilibrium shapes. In the limited shape, the onset of stochasticity is found to be insensitive to the coil current amplitude and governed largely by the evolution of the safety-factor profile. In both devices, prediction of the q-profile evolution is seen to be critical to predicting the later time effects of the coil.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Goddard Space Flight Center Spacecraft Magnetic Test Facility Restoration Project

The Goddard Space Flight Center Spacecraft Magnetic Test Facility (SMTF) was constructed in the 1960's for the purpose of simulating geomagnetic and interplanetary magnetic field environments. The facility includes a three axis Braunbek coil system consisting of 12 loops, 4 loops on each of the three orthogonal axes; a remote Earth field sensing magnetometer and servo controller; and a remote power control and instrumentation building. The inner coils of the Braunbek system are 42-foot in diameter with a 10-foot by 10-foot opening through the outer coils to accommodate spacecraft access into the test volume. The physical size and precision of the facility are matched by only two other such facilities in the world. The facility was used extensively from the late 1960's until the early 1990's when the requirement for spacecraft level testing diminished. New NASA missions planned under the Living with a Star, Solar Terrestrial Probes, Explorer, and New Millennium Programs include precision, high-resolution magnetometers to obtain magnetic field data that is critical to fulfilling their scientific mission. It is highly likely that future Lunar and Martian exploration missions will also use precision magnetometers to conduct geophysical magnetic surveys. To ensure the success of these missions, ground-testing using a magnetic test facility such as the GSFC SMTF will be required. This paper describes the history of the facility, the future mission requirements that have renewed the need for spacecraft level magnetic testing, and the plans for restoring the facility to be capable of performing to its original design specifications.

Vernier, Robert↗

Goddard Space Flight Center Spacecraft Magnetic Test Facility Restoration Project

The Goddard Space Flight Center Spacecraft Magnetic Test Facility (SMTF) was constructed in the 1960's for the purpose of simulating geomagnetic and interplanetary magnetic field environments. The facility includes a three axis Braunbek coil system consisting of 12 loops, 4 loops on each of the three orthogonal axes; a remote Earth field sensing magnetometer and servo controller; and a remote power control and instrumentation building. The inner coils of the Braunbek system are 42-foot in diameter with a 10-foot by 10-foot opening through the outer coils to accommodate spacecraft access into the test volume. The physical size and precision of the facility are matched by only two other such facilities in the world. The facility was used extensively from the late 1960's until the early 1990's when the requirement for spacecraft level testing diminished. New NASA missions planned under the Living with a Star, Solar Terrestrial Probes, Explorer, and New Millennium Programs include precision, high-resolution magnetometers to obtain magnetic field data that is critical to fulfilling their scientific mission. It is highly likely that future Lunar and Martian exploration missions will also use precision magnetometers to conduct geophysical magnetic surveys. To ensure the success of these missions, ground testing using a magnetic test facility such as the GSFC SMTF will be required. This paper describes the history of the facility, the future mission requirements that have renewed the need for spacecraft level magnetic testing, and the plans for restoring the facility to be capable of performing to its original design specifications.

Vernier, Robert↗

A Superconducting transformer system for high current cable testing

This article describes the development of a direct-current (dc) superconducting transformer system for the high current test of superconducting cables. The transformer consists of a core-free 10 464 turn primary solenoid which is enclosed by a 6.5 turn secondary. The transformer is designed to deliver a 50 kA dc secondary current at a dc primary current of about 50 A. The secondary current is measured inductively using two toroidal-wound Rogowski coils. The Rogowski coil signal is digitally integrated, resulting in a voltage signal that is proportional to the secondary current. This voltage signal is used to control the secondary current using a feedback loop which automatically compensates for resistive losses in the splices to the superconducting cable samples that are connected to the secondary. The system has been commissioned up to 28 kA secondary current. The reproducibility in the secondary current measurement is better than 0.05% for the relevant current range up to 25 kA. The drift in the secondary current, which results from drift in the digital integrator, is estimated to be below 0.5 A/min. The system's performance is further demonstrated through a voltage-current measurement on a superconducting cable sample at 11 T background magnetic field. The superconducting transformer system enables fast, high resolution, economic, and safe tests of the critical current of superconducting cable samples.

43 PARTICLE ACCELERATORS↗

Advanced analysis of laser-driven pulsed magnetic diffusion based on quantum molecular dynamics simulation

Magnetic diffusion plays an important role in inertial confinement fusion with strong magnetic fields. In this paper, we improve a previous analysis of the generation and diffusion of the magnetic field [Morita et al., Phys. Plasmas 25, 094505 (2018)]. For the generation process, we calculate the temporal evolution of the coil current using a self-consistent circuit model. The results show that the peak of the calculated magnetic field is delayed by 1.2 ns compared with that of the incident laser pulse. For the diffusion process, we evaluate the electrical conductivity of warm dense gold over a wide temperature range (300 K–100 eV) by combining the Kubo–Greenwood formula based on a quantum molecular dynamics simulation with the modified Spitzer model. Our simulation shows that the maximum magnetic field (530 T) that penetrates the cone is delayed by 2.5 ns compared with the laser peak. This result is consistent with experiments [Sakata et al., Nat. Commun. 9, 3937 (2018)] that showed that applying a strong magnetic field improved the heating efficiency of fusion fuel.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monolithically integrated Helmholtz coils by 3-dimensional printing

3D printing technology is of great interest for the monolithic fabrication of integrated systems; however, it is a challenge to introduce metallic components into 3D printed molds to enable broader device functionality. Here, we develop a technique for constructing a multi-axial Helmholtz coil by injecting a eutectic liquid metal Gallium Indium alloy (EGaIn) into helically shaped orthogonal cavities constructed in a 3D printed block. The tri-axial solenoids each carry up to 3.6 A of electrical current and produce magnetic field up to 70 G. Within the central section of the coil, the field variation is less than 1% and is in agreement with theory. The flow rates and critical pressures required to fill the 3D cavities with liquid metal also agree with theoretical predictions and provide scaling trends for filling the 3D printed parts. These monolithically integrated solenoids may find future applications in electronic cell culture platforms, atomic traps, and miniaturized chemical analysis systems based on nuclear magnetic resonance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗