Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Likelihood”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Systems and methods for fast detection of elephant flows in network traffic

In a system for efficiently detecting large/elephant flows in a network, the rate at which the received packets are sampled is adjusted according to a top flow detection likelihood computed for a cache of flows identified in the arriving network traffic. After observing packets sampled from the network, Dirichlet-Categorical inference is employed to calculate a posterior distribution that captures uncertainty about the sizes of each flow, yielding a top flow detection likelihood. The posterior distribution is used to find the most likely subset of elephant flows. The technique rapidly converges to the optimal sampling rate at a speed O(1/n), where n is the number of packet samples received, and the only hyperparameter required is the targeted detection likelihood.

Gudibanda, Aditya↗

Tuning and Verification of an Internal Flooding Model for Dynamic PRA

In probabilistic risk assessment (PRA), the likelihoods and consequences of basic events are combined to determine possible system level outcomes and the likelihood of each outcome given an initial event. Both the consequences and likelihoods of basic events may be informed by the use of mathematical models or experimental data regarding the phenomena of interest. In either case, the impact of uncertainties on the results need to be evaluated. If a model is used to predict the evolution of an initiating event, uncertainty quantification can be computationally challenging for complex phenomena with many epistemic (e.g., model) uncertainties. In this work, a reduced order model is introduced for the flooding analysis of a multi-room building at a nuclear power plant under uncertainties which can require long run times using high fidelity computer models. The reduced order model focuses on macro-level transfer of water between rooms and tracks the water level within each room. In order to verify the model's fidelity, its results for the phenomena involved in a scenario of interest are compared to those of a computational fluid dynamics (CFD) code, which are taken to represent reality. This work does not focus on the overall fidelity of the flooding model, as the goal of the project for which it was developed is to develop a methodology rather than to analyze a particular case. The focus instead is on the tunability and verifiability of the reduced order model for relevant physical measures. In analyzing a particular case, the model may be required to incorporate more realistic description of phenomena; however, the procedure described in this work may be used to verify its performance as well. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Top Quark Mass Measurement in the Lepton plus Jets Channel Using a Modified Matrix Element Method

The authors report a measurement of the top quark mass, m{sub t}, obtained from p{bar p} collisions at {radical}s = 1.96 TeV at the Fermilab Tevatron using the CDF II detector. They analyze a sample corresponding to an integrated luminosity of 1.9 rfb{sup -1}. They select events with an electron or muon, large missing transverse energy, and exactly four high-energy jets in the central region of the detector, at least one of which is tagged as coming from a b quark. They calculate a signal likelihood using a matrix element integration method, where the matrix element is modified by using effective propagators to take into account assumptions on event kinematics. The event likelihood is a function of m{sub t} and a parameter JES that determines in situ the calibration of the jet energies. They use a neural network discriminant to distinguish signal from background events. They also apply a cut on the peak value of each event likelihood curve to reduce the contribution of background and badly reconstructed events. Using the 318 events that pass all selection criteria, they find m{sub t} = 172.7 {+-} 1.8 (stat. + JES) {+-} 1.2(syst.) GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A stochastic model for tumor geometry evolution during radiation therapy in cervical cancer

Purpose: To develop mathematical models to predict the evolution of tumor geometry in cervical cancer undergoing radiation therapy. Methods: The authors develop two mathematical models to estimate tumor geometry change: a Markov model and an isomorphic shrinkage model. The Markov model describes tumor evolution by investigating the change in state (either tumor or nontumor) of voxels on the tumor surface. It assumes that the evolution follows a Markov process. Transition probabilities are obtained using maximum likelihood estimation and depend on the states of neighboring voxels. The isomorphic shrinkage model describes tumor shrinkage or growth in terms of layers of voxels on the tumor surface, instead of modeling individual voxels. The two proposed models were applied to data from 29 cervical cancer patients treated at Princess Margaret Cancer Centre and then compared to a constant volume approach. Model performance was measured using sensitivity and specificity. Results: The Markov model outperformed both the isomorphic shrinkage and constant volume models in terms of the trade-off between sensitivity (target coverage) and specificity (normal tissue sparing). Generally, the Markov model achieved a few percentage points in improvement in either sensitivity or specificity compared to the other models. The isomorphic shrinkage model was comparable to the Markov approach under certain parameter settings. Convex tumor shapes were easier to predict. Conclusions: By modeling tumor geometry change at the voxel level using a probabilistic model, improvements in target coverage and normal tissue sparing are possible. Our Markov model is flexible and has tunable parameters to adjust model performance to meet a range of criteria. Such a model may support the development of an adaptive paradigm for radiation therapy of cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of ray profile modeling on resolution recovery in clinical CT

Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. However, among vendors and researchers, there is no consensus of how to best achieve these goals. The authors are focusing on the aspect of geometric ray profile modeling, which is realized by some algorithms, while others model the ray as a straight line. The authors incorporate ray-modeling (RM) in nonregularized iterative reconstruction. That means, instead of using one simple single needle beam to represent the x-ray, the authors evaluate the double integral of attenuation path length over the finite source distribution and the finite detector element size in the numerical forward projection. Our investigations aim at analyzing the resolution recovery (RR) effects of RM. Resolution recovery means that frequencies can be recovered beyond the resolution limit of the imaging system. In order to evaluate, whether clinical CT images can benefit from modeling the geometrical properties of each x-ray, the authors performed a 2D simulation study of a clinical CT fan-beam geometry that includes the precise modeling of these geometrical properties. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and a Forbild thorax phantom with circular resolution patterns representing calcifications in the heart region are simulated. An FBP reconstruction with a Ram–Lak kernel is used as a reference reconstruction. The FBP is compared to iterative reconstruction techniques with and without RM: An ordered subsets convex (OSC) algorithm without any RM (OSC), an OSC where the forward projection is modeled concerning the finite focal spot and detector size (OSC-RM) and an OSC with RM and with a matched forward and backprojection pair (OSC-T-RM, T for transpose). In all cases, noise was matched to be able to focus on comparing spatial resolution. The authors use two different simulation settings. Both are based on the geometry of a typical clinical CT system (0.7 mm detector element size at isocenter, 1024 projections per rotation). Setting one has an exaggerated source width of 5.0 mm. Setting two has a realistically small source width of 0.5 mm. The authors also investigate the transition from setting one to two. To quantify image quality, the authors analyze line profiles through the resolution patterns to define a contrast factor (CF) for contrast-resolution plots, and the authors compare the normalized cross-correlation (NCC) with respect to the ground truth of the circular resolution patterns. To independently analyze whether RM is of advantage, the authors implemented several iterative reconstruction algorithms: The statistical iterative reconstruction algorithm OSC, the ordered subsets simultaneous algebraic reconstruction technique (OSSART) and another statistical iterative reconstruction algorithm, denoted with ordered subsets maximum likelihood (OSML) algorithm. All algorithms were implemented both without RM (denoted as OSC, OSSART, and OSML) and with RM (denoted as OSC-RM, OSSART-RM, and OSML-RM). Results: For the unrealistic case of a 5.0 mm focal spot the CF can be improved by a factor of two due to RM: the 4.2 LP/cm bar pattern, which is the first bar pattern that cannot be resolved without RM, can be easily resolved with RM. For the realistic case of a 0.5 mm focus, all results show approximately the same CF. The NCC shows no significant dependency on RM when the source width is smaller than 2.0 mm (as in clinical CT). From 2.0 mm to 5.0 mm focal spot size increasing improvements can be observed with RM. Conclusions: Geometric RM in iterative reconstruction helps improving spatial resolution, if the ray cross-section is significantly larger than the ray sampling distance. In clinical CT, however, the ray is not much thicker than the distance between neighboring ray centers, as the focal spot size is small and detector crosstalk is negligible, due to reflective coatings between detector elements. Therefore,RM appears not to be necessary in clinical CT to achieve resolution recovery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of error covariance structure on estimation of model averaging weights and predictive performance

When conducting model averaging for assessing groundwater conceptual model uncertainty, the averaging weights are often evaluated using model selection criteria such as AIC, AICc, BIC, and KIC (Akaike Information Criterion, Corrected Akaike Information Criterion, Bayesian Information Criterion, and Kashyap Information Criterion, respectively). However, this method often leads to an unrealistic situation in which the best model receives overwhelmingly large averaging weight (close to 100%), which cannot be justified by available data and knowledge. It was found in this study that this problem was caused by using the covariance matrix, CE, of measurement errors for estimating the negative log likelihood function common to all the model selection criteria. This problem can be resolved by using the covariance matrix, Cek, of total errors (including model errors and measurement errors) to account for the correlation between the total errors. An iterative two-stage method was developed in the context of maximum likelihood inverse modeling to iteratively infer the unknown Cek from the residuals during model calibration. The inferred Cek was then used in the evaluation of model selection criteria and model averaging weights. While this method was limited to serial data using time series techniques in this study, it can be extended to spatial data using geostatistical techniques. The method was first evaluated in a synthetic study and then applied to an experimental study, in which alternative surface complexation models were developed to simulate column experiments of uranium reactive transport. It was found that the total errors of the alternative models were temporally correlated due to the model errors. The iterative two-stage method using Cek resolved the problem that the best model receives 100% model averaging weight, and the resulting model averaging weights were supported by the calibration results and physical understanding of the alternative models. Using Cek obtained from the iterative two-stage method also improved predictive performance of the individual models and model averaging in both synthetic and experimental studies.

error correlation↗

Conditions of Asymptotic Normality of One-Step M-Estimators

In the case of independent identically distributed observations, we study the asymptotic properties of one-step M-estimators served as explicit approximations of consistent M-estimators. We find rather general conditions for the asymptotic normality of one-step M-estimators. We consider Fisher’s approximations of consistent maximum likelihood estimators and find general conditions guaranteeing the asymptotic normality of the Fisher estimators even in the case where maximum likelihood estimators do not necessarily exist or are not necessarily consistent.

97 MATHEMATICS AND COMPUTING↗

Deriving Prostate Alpha-Beta Ratio Using Carefully Matched Groups, Long Follow-Up and the Phoenix Definition of Biochemical Failure

Purpose: Prior studies have derived low values of alpha-beta ratio (a/ss) for prostate cancer of approximately 1-2 Gy. These studies used poorly matched groups, differing definitions of biochemical failure, and insufficient follow-up. Methods and Materials: National Comprehensive Cancer Network low- or low-intermediate risk prostate cancer patients, treated with external beam radiotherapy or permanent prostate brachytherapy, were matched for prostate-specific antigen, Gleason score, T-stage, percentage of positive cores, androgen deprivation therapy, and era, yielding 118 patient pairs. The Phoenix definition of biochemical failure was used. The best-fitting value for a/ss was found for up to 90-month follow-up using maximum likelihood analysis, and the 95% confidence interval using the profile likelihood method. Linear quadratic formalism was applied with the radiobiological parameters of relative biological effectiveness = 1.0, potential doubling time = 45 days, and repair half-time = 1 hour. Bootstrap analysis was performed to estimate uncertainties in outcomes, and hence in a/ss. Sensitivity analysis was performed by varying the values of the radiobiological parameters to extreme values. Results: The value of a/ss best fitting the outcomes data was >30 Gy, with lower 95% confidence limit of 5.2 Gy. This was confirmed on bootstrap analysis. Varying parameters to extreme values still yielded best-fit a/ss of >30 Gy, although the lower 95% confidence interval limit was reduced to 0.6 Gy. Conclusions: Using carefully matched groups, long follow-up, the Phoenix definition of biochemical failure, and well-established statistical methods, the best estimate of a/ss for low and low-tier intermediate-risk prostate cancer is likely to be higher than that of normal tissues, although a low value cannot be excluded.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of the Top Quark Mass in the Lepton+Jets Channel Using the Lepton Transverse Momentum

This letter reports a measurement of the top quark mass, M{sub top}, in data from p{bar p} collisions at {radical}s = 1.96 TeV corresponding to 2.7 fb{sup -1} of integrated luminosity at the Fermilab Tevatron using the CDF II detector. Events with the lepton+jets topology are selected. An unbinned likelihood is constructed based on the dependence of the lepton transverse momentum, P{sub T}, on M{sub top}. A maximum likelihood fit to the data yields a measured mass M{sub top} = 176.9 {+-} 8.0{sub stat} {+-} 2.7{sub syst} GeV/c{sup 2}. In this measurement, the contribution by the jet energy scale uncertainty to the systematic error is negligible. The result provides an important consistency test for other M{sub top} measurements where explicit use of the jet energy is made for deriving the top quark mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multivariable degradation modeling and life prediction using multivariate fractional Brownian motion

In system prognostics and health management, multivariable degradation models have been widely developed to predict the life of complex systems using degradation data of multiple Performance Characteristics (PCs). Recent studies have detected a Long-Term Memory (LTM) effect among the degradation process of various PCs, implying a strong coupling phenomenon between the future degradation behavior and historical degradation trajectory. Although the LTM has been widely integrated into single-PC-based degradation modeling, it has not been considered in multi-PC-based scenarios. To capture LTM among multiple PCs, this article proposes a novel LTM-integrated Multivariate Degradation Model (MDM) for system life prediction based on multivariate fractional Brownian motion, which simultaneously incorporates the cross-correlation among different PCs. To estimate parameters of the LTM-integrated MDM, a maximum likelihood method is developed. Here, two likelihood-ratio hypothesis tests are developed to test the existence of the overall and individual LTM effect among multiple PCs. Both simulation studies and physical experiments on the performance degradation of solar energy conversion and storage devices are conducted to validate the proposed model. Results reveal that the proposed LTM-integrated MDM significantly outperforms existing MDMs in life prediction, while the lifetime uncertainty is heavily underestimated by those traditional approaches that neglect the LTM.

42 ENGINEERING↗

Statistically optimal analysis of state-discretized trajectory data from multiple thermodynamic states

We propose a discrete transition-based reweighting analysis method (dTRAM) for analyzing configuration-space-discretized simulation trajectories produced at different thermodynamic states (temperatures, Hamiltonians, etc.) dTRAM provides maximum-likelihood estimates of stationary quantities (probabilities, free energies, expectation values) at any thermodynamic state. In contrast to the weighted histogram analysis method (WHAM), dTRAM does not require data to be sampled from global equilibrium, and can thus produce superior estimates for enhanced sampling data such as parallel/simulated tempering, replica exchange, umbrella sampling, or metadynamics. In addition, dTRAM provides optimal estimates of Markov state models (MSMs) from the discretized state-space trajectories at all thermodynamic states. Under suitable conditions, these MSMs can be used to calculate kinetic quantities (e.g., rates, timescales). In the limit of a single thermodynamic state, dTRAM estimates a maximum likelihood reversible MSM, while in the limit of uncorrelated sampling data, dTRAM is identical to WHAM. dTRAM is thus a generalization to both estimators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improving z-tracking accuracy in the two-photon single-particle tracking microscope

Here, we present a method that can improve the z-tracking accuracy of the recently invented TSUNAMI (Tracking of Single particles Using Nonlinear And Multiplexed Illumination) microscope. This method utilizes a maximum likelihood estimator (MLE) to determine the particle's 3D position that maximizes the likelihood of the observed time-correlated photon count distribution. Our Monte Carlo simulations show that the MLE-based tracking scheme can improve the z-tracking accuracy of TSUNAMI microscope by 1.7 fold. In addition, MLE is also found to reduce the temporal correlation of the z-tracking error. Taking advantage of the smaller and less temporally correlated z-tracking error, we have precisely recovered the hybridization-melting kinetics of a DNA model system from thousands of short single-particle trajectories in silico. Our method can be generally applied to other 3D single-particle tracking techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ANALYSIS OF RADIAL VELOCITY DATA BY A NOVEL ADAPTIVE APPROACH

In this paper, we introduce an estimation technique for analyzing radial velocity data commonly encountered in extrasolar planet detection. We discuss the Keplerian model for radial velocity data measurements and introduce a technique named the iterative adaptive approach (IAA) to estimate the three-dimensional spectrum (power versus eccentricity, orbital period and periastron passage time) of the radial velocity data. We then discuss different ways to regularize the IAA algorithm in the presence of noise and measurement errors. We also discuss briefly the computational aspects of the method and introduce a computationally efficient version of IAA. Finally, we establish the significance of the spectral peaks by using a relaxation maximum likelihood algorithm and a generalized likelihood ratio test. Numerical experiments are carried out on both simulated and real life data sets to evaluate the performance of our method. The real life data sets discussed are radial velocity measurements of the stars HD 63454, HD 208487, and GJ 876.

79 ASTRONOMY AND ASTROPHYSICS↗

FIVE-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE (WMAP) OBSERVATIONS: BAYESIAN ESTIMATION OF COSMIC MICROWAVE BACKGROUND POLARIZATION MAPS

We describe a sampling method to estimate the polarized cosmic microwave background (CMB) signal from observed maps of the sky. We use a Metropolis-within-Gibbs algorithm to estimate the polarized CMB map, containing Q and U Stokes parameters at each pixel, and its covariance matrix. These can be used as inputs for cosmological analyses. The polarized sky signal is parameterized as the sum of three components: CMB, synchrotron emission, and thermal dust emission. The polarized Galactic components are modeled with spatially varying power-law spectral indices for the synchrotron, and a fixed power law for the dust, and their component maps are estimated as by-products. We apply the method to simulated low-resolution maps with pixels of side 7.2 deg, using diagonal and full noise realizations drawn from the WMAP noise matrices. The CMB maps are recovered with goodness of fit consistent with errors. Computing the likelihood of the E-mode power in the maps as a function of optical depth to reionization, {tau}, for fixed temperature anisotropy power, we recover {tau} = 0.091 {+-} 0.019 for a simulation with input {tau} = 0.1, and mean {tau} = 0.098 averaged over 10 simulations. A 'null' simulation with no polarized CMB signal has maximum likelihood consistent with {tau} = 0. The method is applied to the five-year WMAP data, using the K, Ka, Q, and V channels. We find {tau} = 0.090 {+-} 0.019, compared to {tau} = 0.086 {+-} 0.016 from the template-cleaned maps used in the primary WMAP analysis. The synchrotron spectral index, {beta}, averaged over high signal-to-noise pixels with standard deviation {sigma}({beta}) < 0.25, but excluding {approx}6% of the sky masked in the Galactic plane, is -3.03 {+-} 0.04. This estimate does not vary significantly with Galactic latitude, although includes an informative prior.

79 ASTRONOMY AND ASTROPHYSICS↗

MICROLENSING-BASED ESTIMATE OF THE MASS FRACTION IN COMPACT OBJECTS IN LENS GALAXIES

We estimate the fraction of mass that is composed of compact objects in gravitational lens galaxies. This study is based on microlensing measurements (obtained from the literature) of a sample of 29 quasar image pairs seen through 20 lens galaxies. We determine the baseline for no microlensing magnification between two images from the ratios of emission line fluxes. Relative to this baseline, the ratio between the continua of the two images gives the difference in microlensing magnification. The histogram of observed microlensing events peaks close to no magnification and is concentrated below 0.6 mag, although two events of high magnification, DELTAm approx 1.5, are also present. We study the likelihood of the microlensing measurements using frequency distributions obtained from simulated microlensing magnification maps for different values of the fraction of mass in compact objects, alpha. The concentration of microlensing measurements close to DELTAm approx 0 can be explained only by simulations corresponding to very low values of alpha (10% or less). A maximum likelihood test yields alpha = 0.05{sup +0.09}{sub -0.03} (90% confidence interval) for a quasar continuum source of intrinsic size r{sub s{sub 0}}approx2.6x10{sup 15} cm. This estimate is valid in the 0.1-10 M {sub sun} range of microlens masses. We study the dependence of the estimate of alpha with r{sub s{sub 0}}, and find that alpha approx< 0.1 for r{sub s{sub 0}}approx<1.3x10{sup 16} cm. High values of alpha are possible only for source sizes much larger than commonly expected (r{sub s{sub 0}}>>2.6x10{sup 16} cm). Regarding the current controversy about Milky Way/LMC and M31 microlensing studies, our work supports the hypothesis of a very low content in MACHOS (Massive Compact Halo Objects). In fact, according to our study, quasar microlensing probably arises from the normal star populations of lens galaxies and there is no statistical evidence for MACHOS in the dark halos.

79 ASTRONOMY AND ASTROPHYSICS↗

DARK MATTER DISTRIBUTION IN GALAXY GROUPS FROM COMBINED STRONG LENSING AND DYNAMICS ANALYSIS

Using a combined analysis of strong lensing and galaxy dynamics, we characterize the mass distributions and the mass-to-light (M/L) ratios of galaxy groups, virialized structures in the mass range of few x 10{sup 14} M{sub sun}, which form an important transition regime in the hierarchical assembly of mass in {Lambda}CDM cosmology. Our goals are to not only map the mass distributions, but to also test whether the underlying density distribution at this mass scale is dark matter dominated, Navarro-Frenk-White (NFW) like as hypothesized by the standard cosmogony, or isothermal as observed in baryon-rich massive field galaxies. We present details of our lensing + galaxy dynamics formalism built around three representative density profiles, the dark matter dominant NFW and Hernquist distributions, compared with the softened isothermal sphere which matches baryon-rich galaxy scale objects. By testing the effects on the characteristics of these distributions due to variations in their parameters, we show that mass measurements in the core of the group (r/r{sub vir} {approx} 0.2), determined jointly from a lens model and from differential velocity dispersion estimates, may effectively distinguish between these density distributions. We apply our method to multi-object spectroscopy observations of two groups, SL2SJ143000+554648 and SL2SJ143139+553323, drawn from our catalog of galaxy group scale lenses discovered in CFHTLS-Wide imaging. With the lensing and dynamical mass estimates from our observations along with a maximum likelihood estimator built around our model, we estimate the concentration index characterizing each density distribution and the corresponding virial mass of each group. Our likelihood estimation indicates that both groups are dark matter dominant and rejects the isothermal distribution at >>3{sigma} level. For both groups, the estimated i-band M/L ratios of {approx}260 M{sub sun} L{sub sun} {sup -1} are similar to other published values for groups. The Gaussian distribution of the velocities of their member galaxies supports a high degree of virialization. The differences in their virial masses, 2.8 and 1.6 x 10{sup 14} M{sub sun}, and velocity dispersions, 720 and 560 km s{sup -1}, may indicate however that each group is at a different stage of transition to a cluster. We aim to populate this important transition regime with additional results from ongoing observations of the remaining lensing groups in our catalog.

79 ASTRONOMY AND ASTROPHYSICS↗

THE AGE, STELLAR CONTENT, AND STAR FORMATION TIMESCALE OF THE B59 DENSE CORE

We have investigated the stellar content of Barnard 59 (B59), the most active star-forming core in the Pipe Nebula. Using the SpeX spectrograph on the NASA Infrared Telescope Facility, we obtained moderate resolution, near-infrared (NIR) spectra for 20 candidate young stellar objects (YSOs) in B59 and a representative sample of NIR and mid-IR bright sources distributed throughout the Pipe. Measuring luminosity and temperature sensitive features in these spectra, we identified likely background giant stars and measured each star's spectral type, extinction, and NIR continuum excess. To measure B59's age, we place its candidate YSOs in the Hertzsprung-Russell diagram and compare their location to YSOs in several well-studied star-forming regions, as well as predictions of pre-main-sequence (PMS) evolutionary models. We find that B59 is composed of late-type (K4-M6) low-mass (0.9-0.1 M{sub sun}) YSOs whose median stellar age is comparable to, if not slightly older than, that of YSOs within the {rho} Oph, Taurus, and Chameleon star-forming regions. Deriving absolute age estimates from PMS models computed by D'Antona et al., and accounting only for statistical uncertainties, we measure B59's median stellar age to be 2.6 {+-} 0.8 Myr. Including potential systematic effects increases the error budget for B59's median (DM98) stellar age to 2.6{sup +4.1}{sub -2.6} Myr. We also find that the relative age orderings implied by PMS evolutionary tracks depend on the range of stellar masses sampled, as model isochrones possess significantly different mass dependences. The maximum likelihood median stellar age we measure for B59, and the region's observed gas properties, suggests that the B59 dense core has been stable against global collapse for roughly six dynamical timescales and is actively forming stars with a star formation efficiency per dynamical time of {approx}6%. While the {approx}150% uncertainties associated with our age measurement propagate directly into these derived star formation timescales, the maximum likelihood values nonetheless agree well with recent star formation simulations that incorporate various forms of support against collapse, such as subcritical magnetic fields, outflows, and radiative feedback from protostellar heating.

79 ASTRONOMY AND ASTROPHYSICS↗

A ROBUST DETERMINATION OF THE SIZE OF QUASAR ACCRETION DISKS USING GRAVITATIONAL MICROLENSING

Using microlensing measurements for a sample of 27 image pairs of 19 lensed quasars we determine a maximum likelihood estimate for the accretion disk size of an average quasar of r{sub s} = 4.0{sup +2.4}{sub -3.1} lt-day at rest frame ({lambda}) = 1736 Angstrom-Sign for microlenses with a mean mass of (M) = 0.3 M{sub Sun }. This value, in good agreement with previous results from smaller samples, is roughly a factor of five greater than the predictions of the standard thin disk model. The individual size estimates for the 19 quasars in our sample are also in excellent agreement with the results of the joint maximum likelihood analysis.

79 ASTRONOMY AND ASTROPHYSICS↗