Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Impact loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

A High Temperature Gas Reactor Integrated Energy System Using Energy Storage as a Buffer for Hydrogen Production

Analysis of an integrated energy system producing hydrogen in a high temperature steam electrolysis system via steam provided by a sensible heat thermal energy storage system charged by a high temperature gas reactor. Preliminary results over a continuous discharge cycle and single charging cycle shows minimal reactor impact despite 25% electrical power load change. Hydrogen production is held constant with steam provided by the thermal energy storage system.

08 HYDROGEN↗

Machine-inudced backgrounds: their origin and loads on ATLAS/CMS

A detailed analysis of machine-induced backgrounds (MIB) in the LHC collider detectors is performed with focus on origin and rates for three sources: tertiary beam halo, beam-gas interactions and kicker prefire. Particle fluxes originating from these operational and accidental beam losses are carefully calculated with the MARS15 code and presented at the entrance to the ATLAS and CMS experimental halls. It is shown that background rates in detector subsystems strongly depend on the origin of MIB, particle energy and type. Using this source term, instantaneous and integrated loads on the detectors and impact on the detector performance can be derived.

43 PARTICLE ACCELERATORS↗

Enhancing Advanced Candu Proliferation Resistance Fuel with Minor Actinides

The advanced nuclear system will significantly advance the science and technology of nuclear energy systems and to enhance the spent fuel proliferation resistance. Minor actinides (MA) are viewed more as a resource to be recycled, and transmuted to less hazardous and possibly more useful forms, rather than simply disposed of as a waste stream in an expensive repository facility. MAs can play a much larger part in the design of advanced systems and fuel cycles, not only as additional sources of useful energy, but also as direct contributors to the reactivity control of the systems into which they are incorporated. In this work, an Advanced CANDU Reactor (ACR) fuel unit lattice cell model with 43 UO 2 fuel rods will be used to investigate the effectiveness of a Minor Actinide Reduction Approach (MARA) for enhancing proliferation resistance and improving the fuel cycle performance. The main MARA objective is to increase the 238 Pu / Pu isotope ratio by using the transuranic nuclides ( 237 Np and 241 Am) in the high burnup fuel and thereby increase the proliferation resistance even for a very low fuel burnup. As a result, MARA is a very effective approach to enhance the proliferation resistance for the on power refueling ACR system nuclear fuel. The MA transmutation characteristics at different MA loadings were compared and their impact on neutronics criticality assessed. The concept of MARA, significantly increases the 238Pu/Pu ratio for proliferation resistance, as well as serves as a burnable absorber to hold-down the initial excess reactivity. It is believed that MARA can play an important role in atoms for peace and the intermediate term of nuclear energy reconnaissance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A simulation study of atmospheric mercury and its deposition in the Great Lakes

The Great Lakes eco-region is one of the largest sources of fresh water in North America; however it is chronically exposed to heavy metal loadings such as mercury. In this study a comprehensive model evaluation was conducted to determine mercury loadings to the Great Lakes. The study also evaluated the relative impact of anthropogenic mercury emissions from China, regional and global sources on deposition to the Great Lakes. For the 2005 study period, CMAQ 4.7.1 model estimated a total of 6.4 ± 0.5 metric tons of mercury deposited in the Great Lakes. The total deposition breakdown showed a net loading for Lake Superior of 1906 ± 246 kg/year which is the highest of all the lakes. Lake Michigan followed with 1645 ± 203 kg/year and 1511 ± 107 kg/year in Lake Huron. The lowest total deposition was seen in Lakes Erie and Ontario amassing annual totals of 837 ± 107 kg and 506 ± 63 kg, respectively. Wet and dry deposition of mercury were both significant pathways and exhibited strong seasonal variability with higher deposition occurring in the warmer months (June–November) and the lowest in winter. Wet deposition of RGM significantly influenced the deposition proportions accounting for roughly 90% of all mercury deposited. Of the three emission sources (global background, integrated planning management (IPM) and Chinese), global background concentrations represented the maximum impact to deposition loading in the Great Lakes, except for Lake Erie and parts of Lake Michigan. There was minimal seasonality for the global background, but differences in percentage contribution between dry (28–97%) and wet deposition (43–98%) was predicted. The contributions were seen mainly in the northern sections of the Great Lakes further away from IPM point sources. These findings suggest strong localized impact of IPM sources on the southernmost lakes. Deposition as a result of emissions from China exhibited seasonality in both wet and dry deposition and showed significant contributions ranging from 0.2 to 9%.

Chinese emissions↗

Skull Flexure from Blast Waves: A Mechanism for Brain Injury with Implications for Helmet Design

Traumatic brain injury [TBI] has become a signature injury of current military conflicts, with debilitating, costly, and long-lasting effects. Although mechanisms by which head impacts cause TBI have been well-researched, the mechanisms by which blasts cause TBI are not understood. From numerical hydrodynamic simulations, we have discovered that non-lethal blasts can induce sufficient skull flexure to generate potentially damaging loads in the brain, even without a head impact. The possibility that this mechanism may contribute to TBI has implications for injury diagnosis and armor design.

42 ENGINEERING↗

Autonomous Grid Support Functionality in Variable-Speed Drive-Based End-Use Loads

High penetration of inverter-based resources into power systems causes lower inertia, and it becomes more challenging to maintain grid stability during contingency events. While conventional demand response and shedding at the load side suffer from slow response, impact by unavailability, and issues from communication, variable-speed drives (VSDs) are becoming strong candidates for fast frequency response (FFR) thanks to their fast response and reduced user impact from variable power adjustment capability. In this letter, we propose an autonomous frequency support control method for a residential refrigerator with a VSD, a promising target small end-use load for FFR. We analyze the effect of the proposed controller on grid stability, and we verify the performance through laboratory experiments with a commercially available refrigerator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Porous Transport Layer Morphology on the Performance of Proton Exchange Membrane Water Electrolyzers with Ultra-Low Iridium Loadings

Reducing Ir loadings in proton exchange membrane water electrolyzer anodes is critical for lowering capital expenses. Loading reduction could be achieved by improving the Ir activity via doping/alloying and/or the development of advanced microstructures. However, the anode porous transport layer (PTL) is a comparatively simple component whose properties also impact Ir utilization. Therefore, well-designed PTLs may also enable reduced Ir loadings. In this work, we survey eight PTLs from various manufacturers to observe their impact on cell performance at low (0.4 mg Ir cm -2 ) and ultralow (0.1 mg Ir cm -2 ) Ir loadings. The PTLs were characterized by their microstructural properties, including porosity, particle size distribution, and pore size distribution. Electrochemical cell performance was correlated to PTL morphology, and it was found that PTLs with lower porosities and smaller particle and pore radii enabled good performance even at ultralow Ir loadings. 1000-h durability testing indicated that using lower porosity PTLs can significantly improve durability behavior. A runaway voltage phenomenon was observed during durability testing of cells with ultralow Ir loadings, which was caused by increases in both anode and cathode overpotentials. Furthermore, we observed that the beginning of test performance of 0.1 mg Ir cm -2 cells correlates to the 1000-h degradation rates of 0.4 mg Ir cm -2 cells, suggesting that for the Ir catalyst used in this work, short-term testing at ultralow loadings can be used as an indicator of long-term degradation at higher loadings.

08 HYDROGEN↗

Procedures for Calculating Residential Dehumidification Loads

Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity. The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.

47 OTHER INSTRUMENTATION↗

Shock-reshock of zirconium to explore the effect of microstructure on the alpha-omega phase transformation

Phase transformations play an important role in the mechanical behavior of materials subjected to extreme loading conditions. A series of shock-reshock experiments were fielded to determine whether the phase transitions in materials are significantly enhanced or inhibited by preexisting microstructural features. Polycrystalline zirconium samples were shock loaded using gas-gun plate impact and soft recovered to examine microstructure using electron backscatter diffraction (EBSD). Drive conditions were varied to study the (hcp) alpha to (hexagonal) omega solidsolid phase transformation. Recovered samples were then subjected to a second shock loading event to determine the change in material behavior as a function of pre-shock microstructure. Crystallography of phase fragments in the final microstructure showed that prior twinning (formed during the shock to a peak stress below the transition threshold) appeared to suppress omega formation/retention after reshock. Conversely, when a material was initially shocked into the omega phase field, retained-omega was not found to have a large impact on subsequent omega formation during reshock. This suggests that nucleation and growth of omega phase are important processes, and the relative activity of nucleation vs. growth processes is modified by a pre-existing substructure. Additionally, orientation relationships reveal a reverse transformation pathway (omega to alpha) dominates the final microstructure, suggesting significant grain growth in the omega phase field is possible even for dynamic timescales.

36 MATERIALS SCIENCE↗

Impacts of Lock-off Time on Virtual Battery Model from Thermostatically Controlled Loads

We test through simulation the influence of lock-off time on the aggregated flexibility of thermostatically controllable loads (TCLs), which is modeled by virtual battery (VB) models. The VB model provides a simple but effective way to quantify the aggregated flexibility of TCLs, but its efficacy is not clear when there is lock-off time for TCLs. TCLs cannot be turned on during the lock-off period, and so lock-off time imposes inevitable restrictions on not only the flexibility of individual TCLs but also the aggregated flexibility of a group of TCLs. We first test the influence of lock-off time on the efficacy of VB models with two artificial signals. One of the signal is of low frequency while the other is of high frequency. We then use real-world data to test the influence. One set of data is from a duck curve from CAISO while the other set of data is from AGC signals from PJM. The duck curve changes slowly while the AGC signals change rapidly over time. From both the artificial signals and real-word data, we find that lock-off time has a more significant impact on rapid signals than on slow signals.

Wang, Peng↗

Computational Hydrocode Study of Target Damage due to Fragment-Blast Impact

A target's terminal ballistic effects involving explosively generated fragments, along with the original blast, are of critical importance for many different security and safety related applications. Personnel safety and protective building design are but a few of the practical disciplines that can gain from improved understanding combined loading effects. Traditionally, any engineering level analysis or design effort involving explosions would divide the target damage analysis into two correspondingly critical areas: blast wave and fragment related impact effects. The hypothesis of this paper lies in the supposition that a linear combination of a blast-fragment loading, coupled with an accurate target response description, can lead to a non-linear target damage effect. This non-linear target response could then stand as the basis of defining what a synergistic or combined frag-blast loading might actually look like. The table below, taken from Walters, et. al. categorizes some of the critical parameters driving any combined target damage effect and drives the evaluation of results. Based on table 1 it becomes clear that any combined frag-blast analysis would need to account for the target response matching similar ranges for the mechanics described above. Of interest are the critical times upon which a blast event or fragment impact loading occurs relative to the target's modal response. A blast, for the purposes of this paper is defined as the sudden release of chemical energy from a given material (henceforth referred to as an energetic material) onto its surrounding medium. During the coupling mechanism a discrete or discontinuous shockwave is generated. This shockwave travels outward from the source transferring energy and momentum to any surrounding objects including personnel and engineering structures. From an engineering perspective blast effects are typically characterized by way of physical characteristics such as Peak Pressure (PP), Time of Arrival (TOA), Pressure-Impulse (PI) and Time of Duration (TD). Other peculiarities include the radial decrease in pressure from the source, any fireball size measurement, and subsequent increase in temperature from the passing of the shockwave through the surrounding medium. In light of all of these metrics, the loading any object receives from a blast event becomes intricately connected to the distance between itself and the source. Because of this, a clear distinction is made between close-in effects and those from a source far away from the object of interest. Explosively generated fragments on the other hand are characterized by means of their localized damage potential. Metrics such as whether the fragment penetrates or perforates a given object is quantified as well as other variables including fragment's residual velocity, % kinetic energy decrease, residual fragment mass and other exit criteria. A fragment launched under such violent conditions could easily be traveling at speeds in excess of 2500 ft/s. Given these speeds it is conceivable to imagine how any given fragment could deliver a concentrated load to a target and penetrates through walls, vehicles or even the protection systems of nearby personnel. This study will focus on the individual fragment-target impact event with the hopes of expanding it to eventually include statistical procedures. Since this is a modeling excursion into the combined frag-blast target damage effects the numerical methods used to frame this problem become important in-so-far as the simulations are done in a consistent manner. For this study a Finite-Element based Hydrocode solution called ALE3D (ALE=Arbitrary Lagrangian-Eulerian) was utilized. ALE3D is developed by Lawrence Livermore National Laboratory (Livermore, CA), and as this paper will show, successfully implemented a converged ALE formulation including as many of the different aspects needed to query the synergistic damage on a given target. Further information on the modeling setup is included.

42 ENGINEERING↗

Nonsteady Load Responses to Daytime Atmospheric Turbulence Eddies on the DOE 1.5 MW Wind Turbine at NREL

Field data collected from the NREL/GE 1.5MW wind turbine (WT) and met tower (MetT) at the NREL Wind Technology Center near Boulder, CO June-October 2018 were analyzed to quantify the impacts of turbulence eddies on the load responses measured from sensors on the main shaft, blade and tower. The passage of individual mountain-generated eddies from the met tower to the WT were critically determined by correlating the optimal time shifts in signal between MetT and nacelle anemometers with mean advection time. Loading responses from mountain eddy passage were compared with atmospheric eddies from the north/south, unimpeded by the mountains, and found to be similar. Whereas time variations in torque were highly correlated with time changes in horizontal eddy velocity, the out-of-plane bending moments on the main shaft (directly forcing the main bearing) were uncorrelated with horizontal eddy velocity. This result is consistent with a previous LES study indicating that the main bearing is forced by asymmetrical interactions between the WT rotor and turbulence eddies, while power fluctuations respond primarily to advective eddy velocity. Surprisingly, the nacelle anemometer produced statistics very similar to the MetT.

ENGINEERING,WIND ENERGY↗

Resolution requirements for high-speed droplet impact along a rigid wall

The mechanical and thermal loads that are produced on high-speed projectiles from a droplet are key in the projectile development.To accurately predict the pressure produced along the wall surface during impact, it is important to correctly model the air/water interface of the droplet. Novel modeling approaches such as the Phase-Field enable control of the (numerical) interface thickness. However, the interplay between the grid resolution (including potential adaptive mesh refinement) and the interface thickness is unclear. In this work, the resolution requirements for numerical simulations of a two-dimensional cylindrical water droplet impacting a rigid wall at Mach four are computationally investigated. Numerical simulations are performed using a second-order accurate scheme with adaptive mesh refinement and a Phase-Field interface model. The choice of numerical interface thickness and resolution parameters affects the maximum pressure and location of the maximum pressure along the wall. The overall maximum pressure does not converge even at high resolutions. The number of levels and thickness (number of cells across the interface) play a role in obtaining a well behaved solution.

Burrell, E.↗

Nonsteady Load Responses to Mountain-Generated Turbulence Eddies on the DOE 1.5 MW Wind Turbine at the National Wind Technology Center

Field data collected from the NREL/GE 1.5MW wind turbine and met tower at the NREL Wind Technology Center near Boulder, Colorado from June-October 2018 were analyzed to quantify the impacts of turbulence eddies on the load responses measured from sensors on the main shaft, blade and tower. The passage of individual mountain-generated eddies from the met tower to the wind turbine were critically determined by correlating the optimal time shifts in signal between met tower and nacelle anemometers with mean advection time. Loading responses from mountain eddy passage were compared with atmospheric eddies from the north/south, unimpeded by the mountains, and found to be similar. Whereas time variations in torque were highly correlated with time changes in horizontal eddy velocity, the out-of-plane bending moments on the main shaft (directly forcing the main bearing) were uncorrelated with horizontal eddy velocity. This result is consistent with a previous LES study indicating that the main bearing is forced by asymmetrical interactions between the rotor and turbulence eddies, while power fluctuations respond primarily to advective eddy velocity. Surprisingly, the nacelle anemometer produced statistics very similar to the met tower.

ENGINEERING,WIND ENERGY↗

Fabrication, thermal analysis, and heavy ion irradiation resistance of epoxy matrix nanocomposites loaded with silane-functionalized ceria nanoparticles

This paper describes a detailed understanding of how nanofillers function as radiation barriers within the polymer matrix, and how their effectiveness is impacted by factors such as composition, size, loading, surface chemistry, and dispersion. Here, we designed a comprehensive investigation of heavy ion irradiation resistance in epoxy matrix composites loaded with surface-modified ceria nanofillers, utilizing tandem computational and experimental methods to elucidate radiolytic damage processes and relate them to chemical and structural changes observed through thermal analysis, vibrational spectroscopy, and electron microscopy. A detailed mechanistic examination supported by FTIR spectroscopy data identified the bisphenol A moiety as a primary target for degradation reactions. Results of computational modeling by the Stopping Range of Ions in Matter (SRIM) Monte Carlo simulation were in good agreement with damage analysis from surface and cross-sectional SEM imaging. All metrics indicated that ceria nanofillers reduce the damage area in polymer nanocomposites, and that nanofiller loading and homogeneity of dispersion are key to effective damage prevention. The results of this study represent a significant pathway for engineered irradiation tolerance in a diverse array of polymer nanocomposite materials. Numerous areas of materials science can benefit from utilizing this facile and effective method to extend the reliability of polymer materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distributed Energy Resource-Cognizant Upgrade Paths to the Traditional Restoration Strategy of Utilities for Improved Load Restoration: Preprint

Climate change has resulted in increasingly impactful and more frequent occurrences of extreme weather events. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks under fault scenarios; however, currently, utilities deploying the automated fault location, isolation and restoration (FLISR) function in their advanced distribution management system (ADMS) do not take into account the available generation and load-modification capabilities of distributed energy resources present in the disconnected network due to an upstream isolated fault. This results in the network reconfiguration and restoration to result in sub-optimal load restoration. Therefore, this paper presents two approaches that can upgrade the existing FLISR capabilities of distribution utilities to significantly increase the restoration of critical loads. The performance of the proposed approaches is evaluated on a numerical model of a real distribution feeder in Georgia, USA.

DER↗

A Proposed Path Forward for Standardization - 17131

Incorporation of a standardized canister system into the commercial waste management system represents an opportunity to develop an integrated approach to storage, transportation, and disposal issues. However, regardless of timing and method, deployment of such a system would have the potential to cause significant system-wide impacts. The current inventory of commercial spent nuclear fuel dry storage systems is diverse and increasing. In addition, the currently loaded systems are large-capacity systems (up to 37 pressurized water reactor assemblies or 89 boiling water reactor assemblies) that are now able to accommodate large (greater than 45 kilowatts) amounts of heat during storage, with the potential to accommodate fairly high heat loads (∼32 kilowatts) for transportation as well. A standardized canister system designed with disposition in mind would likely be significantly smaller than the current systems and have dramatically lower heat limit maximums. Over the past few years, the Department of Energy (DOE) Office of Nuclear Energy Fuel Cycle Technologies Nuclear Fuels Storage and Transportation Planning Project (NFST) has performed a number of system analyses using logistic simulations to evaluate the impacts of incorporating these smaller canisters into the commercial waste management system. These simulations predict the amount of resources (e.g., staff, canisters/casks, rail-cars, facilities), the size of facilities, and the timing of operations, as well as provide rough order-of-magnitude cost estimates. In addition to system analyses, DOE funded efforts by EnergySolutions to develop a generic design of a small-capacity standardized canister system and investigate innovative operational approaches to minimize the at-reactor operational impacts of loading such smaller canisters. A result of EnergySolutions' work was the development of a 'canister-in-carrier' concept that would allow for loading, storing, transporting, and potentially disposing of groups of small canisters at the same time. With the inclusion of this new concept, the most recent system analyses show that incorporating standardized canister systems into the commercial waste management system has the potential for some system-wide cost reductions in addition to the flexibility that smaller canisters would provide to the system. Based on these analyses, the authors of this paper recommend that DOE fund (1) a demonstration of the ability to weld up to four small canisters at the same time to confirm the feasibility and practicality of the canister-in-carrier concept and (2) the development of a more detailed conceptual design for future applications for Certificates of Compliance, if standardized canisters were incorporated into the commercial waste management system. This paper documents both the results of the latest assessment of standardized canister concepts including the canister-in-carrier concept and the authors' recommendations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗