Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IONIZATION CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Comprehensive Analysis of Streaming and Shutdown Dose Rate Experiments at JET with ORNL Fusion Neutronics Workflows

Current experimental fusion systems and conceptual designs of fusion pilot plants (FPPs) are growing in complexity and size. Several radiation metrics are crucial to the safe operation of fusion machines, including neutron flux streaming through openings and the shutdown dose rate (SDDR). Most current designs of advanced experimental fusion systems—and the most probable candidates for FPPs—are based on the tokamak concept, which is prone to neutron streaming through the myriad openings needed for diagnostic and support systems. SDDR is caused by decay gamma rays from radionuclides that become activated by neutrons during the operation of a fusion system that use deuterium-deuterium (DD), tritium-tritium, or deuterium-tritium plasma. Because computational tools have become essential for determining these radiation metrics, they must be validated against reliable and applicable experimental data. Experiments at the Joint European Torus (JET) provide a unique source of experimental data for validating computational tools and nuclear data used to determine SDDR and neutron fluxes in streaming-dominated geometries. Here, this paper presents the comprehensive analysis of the high-performance DD JET SDDR, and streaming experiments performed using Oak Ridge National Laboratory (ORNL) fusion workflows. The computational results were compared with experimental results that consist of online SDDR measurements with ionization chambers and neutron fluence streaming measurements using thermoluminescent detectors. The ratio of calculated-to-experimental SDDR values ranges from 0.6 to 2.5, and the streaming results range from 0.5 to 8.0. Future work will include analyzing the JET 2021 DTE2 campaign alongside the integration of the Shift Monte Carlo transport code into all ORNL fusion neutronics workflows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron-induced fission cross section measurement of 233 U, 241 Am and 243 Am in the energy range 0.5 MeV En 20 MeV at n TOF at CERN

Neutron-induced fission cross section measurements of 233U, 243Am and 241Am relative to 235U have been carried out at the neutron time-of-flight facility n TOF at CERN. A fast ionization chamber has been employed. All samples were located in the same detector; therefore the studied elements and the reference 235U target are subject to the same neutron beam.

Belloni, F.↗

Beam characterization at NSRL for radiobiological experiments—phase 1

An experimental campaign was carried out at the NASA Space Radiation Laboratory to perform an additional, independent dosimetric characterization of the beams of protons, helium and carbon ions for radiobiological experiments. The campaign was undertaken by the request and with the support from the National Cancer Institute, U.S. In this initial phase, the goals were to obtain a first assessment of the dosimetric reproducibility of the beam control system, including analysis of spatial homogeneity and evaluation of ion beam contamination. They should facilitate the design of further experimental campaigns for beam characterization for radiobiological experiments. Measurements included reference dosimetry with comparison of in-house and external ionization chambers and electrometers, lateral-dose profile measurements in air, depth-dose profile in a water tank, evaluation of water equivalent thickness of a HDPE binary range shifter and estimation of impurities of the investigated helium-ion beam. The experiments and results are presented.

43 PARTICLE ACCELERATORS↗

Upgrades to the TRIUMF Fast Ion Counter, TRIFIC

TRIFIC, the TRIUMF Fast Ion Counter, is a downstream ionization chamber which provides beam composition monitoring and recoil tagging for in-beam reaction experiments. TRIFIC has been commissioned and deployed for use with radioactive isotope beams at the TRIUMF-ISAC facility. Recently, the detector has been upgraded to include an improved gas window that can accommodate higher beam rates and position-sensitive electrode grids for better position reconstruction.

Gaseous detectors↗

Single-particle and dipole excitations in Co 62

An extensive study of the level structure of 62 Co has been performed following a complex multinucleon transfer reaction, 26 Mg( 48 Ca, 2α3npγ) 62 Co, at beam energies of 275, 290, and 320 MeV. The combination of the Gammasphere array, the fragment mass analyzer, and a focal-plane ionization chamber was used to identify and delineate excited levels in 62 Co. A considerable extension to the 62 Co level scheme is proposed with firm spin-parity values assigned on the basis of angular distribution and correlation analyses. Here, various level sequences built upon states of single-particle character have been observed, and an interpretation of these structures in the framework of the spherical shell model is presented. At moderate spins, two dipole bands have been observed and, based on their phenomenological study, a possible magnetic rotation character is suggested. However, theoretical calculations performed using the particle rotor model support magnetic rotation for only one of these dipole bands.

59 ≤ A ≤ 89↗

Measurement of the Mo 100 ( α , x n ) cross section at weak r -process energies

Here, the weak r process in neutrino-driven winds following a core-collapse supernova is thought to contribute to the cosmic abundances of the first r-process peak elements between Se and Ag. Sensitivity studies have found that the early nucleosynthesis in the weak r process is primarily driven by (α, xn) reactions due to the high temperatures, and that current nuclear physics uncertainties in the (α, xn) rates result in significant uncertainties of the calculated abundances. The weak r-process path proceeds several nuclei away from stability where (α, xn) reaction cross sections have not yet been measured. In this paper we report the 100 Mo (α, xn) cross section (between 8.9 and 13.2 MeV in the center of mass, corresponding to 3.5–6.8 GK) in inverse kinematics using the Multi-Sampling Ionization Chamber (MUSIC) detector at the Argonne Tandem Linac Accelerator System (ATLAS) facility. With this first measurement of the 100 Mo (α, xn) cross section, we have demonstrated the ability of MUSIC to measure (α, xn) cross sections for A up to 100, therefore paving the way for further measurements with radioactive beams at ATLAS or the Facility for Rare Isotope Beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First direct measurement of the 13 $\mathrm{N(α, ρ)}$ 16 $\mathrm{O}$ reaction relevant for core-collapse supernovae nucleosynthesis

We report that understanding the explosion mechanism of a core-collapse supernova (CCSN) is important to accurately model CCSN scenarios for different progenitor stars using model-observation comparisons. The uncertainties of various nuclear reaction rates relevant for CCSN scenarios strongly affect the accuracy of these stellar models. Out of these reactions, the 13 N(α, p) 16 O reaction has been found to affect various stages of a CCSN at varying temperatures. This work presents the first direct measurement of the 13 N(α, p) 16 O reaction performed using a 34.6 MeV beam of radioactive 13 N ions and the active-target detector MUSIC (MUlti-Sampling Ionization Chamber) at Argonne National Laboratory. The resulting total 13 N(α, p) 16 O reaction cross sections from this measurement in the center-of-mass energy range of 3.26 - 6.02 MeV are presented and compared with calculations using the Hauser-Feshbach formalism. Uncertainties in the reaction rate have been dramatically reduced at CCSN temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy dependence of fission product yields in the second-chance fission region

An extensive dataset of cumulative fission product yields has been generated under a joint collaboration between Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and the Triangle Universities Nuclear Laboratory (TUNL). The energy dependence of the cumulative yield for a select number of high-yield fission products has been measured using quasimonoenergetic neutrons with energies between 5.5 and 11.0 MeV. This is in addition to previously published data covering 0.5–4.5 and 14.8 MeV. The absolute number of fissions was determined during the irradiation period using dual-fission ionization chambers, and the fission products were measured postactivation by whole target γ-ray spectroscopy. Here this paper presents the absolute cumulative fission product yields as a function of incident neutron energy from the neutron-induced fission of 235 U, 238 U, and 239 Pu isotopes at four incident energies in the second-chance fission region and compares them with existing literature values. Corrections relevant to this collaboration's previously published data are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Direct cross-section measurement of the weak r -process Sr 88 ( α , n ) Zr 91 reaction in ν -driven winds of core-collapse supernovae

About half of the heavy elements beyond iron are known to be produced by the rapid neutron capture process, known as the r process. However, the astrophysical site producing the r process is still uncertain. Chemical abundances observed in several cosmic sites indicate that different mechanisms should be at play. For instance, the abundances around silver measured in a subset of metal-poor stars indicate the presence of a weak r process. This process may be active in neutrino-driven winds of core collapse supernovae where (α,n) reactions dominate the synthesis of Ζ ≈ 40 elements in the expelled materials. Scarcely measured, the rates of (α,n) reactions are determined from statistical Hauser-Feshbach calculations with α-optical-model potentials, which are still poorly constrained. Further, the uncertainties of the (α,n) reaction rates therefore make a significant contribution to the uncertainties of the abundances determined from stellar modeling. In this work, the 88 Sr (α,n)⁢ 91 Zr reaction which impacts the weak r-process abundances has been probed at astrophysics energy for the first time; directly measuring the total cross sections at astrophysical energies of 8.37–13.09 MeV in the center of mass (3.8–7.5 GK). Two measurements were performed at ATLAS with the electrically segmented ionization chamber MUSIC, in inverse kinematics, while following the active target technique. The cross sections of this α-induced reaction on 88 Sr, located at the shell closure N = 50, have been found to be lower than expected, by a factor of 3, despite recent statistical calculations validated by measurements on neighboring nuclei. This result encourages more experimental investigations of (α,n) reactions, at Ν = 50 and towards the neutron-rich side, to further test the predictive power and reliability of such calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron-induced fission cross section of Np 237 in the keV to MeV range at the CERN n_TOF facility

We experimentally determined the neutron-induced fission cross section of Np-237 at the high-resolution and high-intensity facility n_TOF, at CERN, in the energy range 100 keV to 9 MeV, using the U-235(n, f) and U-238(n, f) cross section standards below and above 2 MeV, respectively. Moreover, a fast ionization chamber was used in order to detect the fission fragments from the reactions and the targets were characterized as far as their mass and homogeneity are concerned by means of a spectroscopy and Rutherford backscattering spectroscopy respectively. Finally, theoretical calculations within the Hauser-Feshbach formalism have been performed, employing the EMPIRE code, and the model parameters were tuned in order to successfully reproduce the experimental fission cross-sectional data and simultaneously all the competing reaction channels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of the 22 Mg Waiting Point Relevant for X-Ray Burst Nucleosynthesis via the 22 Mg(α,p) 25 Al Reaction

The 22 Mg(α, p) 25 Al reaction rate has been identified as a major source of uncertainty for understanding the nucleosynthesis flow in Type-I x-ray bursts. Here, we report a direct measurement of the energy-and angle-integrated cross sections of this reaction in a 3.3-6.9 MeV center-of-mass energy range using the MUlti-Sampling Ionization Chamber (MUSIC). The new 22 Mg(α, p) 25 Al reaction rate is a factor of ~4 higher than the previous direct measurement of this reaction within temperatures relevant for x-ray bursts, resulting in the 22 Mg waiting point of x-ray burst nucleosynthesis flow to be significantly bypassed via the (α, p) reaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pulse-resolved intensity measurements at a hard X-ray FEL using semi-transparent diamond detectors

Solid-state ionization chambers are presented based on thin diamond crystals that allow pulse-resolved intensity measurements at a hard X-ray free-electron laser (FEL), up to the 4.5 MHz repetition rate that will become available at the European XFEL. Due to the small X-ray absorption of diamond the thin detectors are semi-transparent which eases their use as non-invasive monitoring devices in the beam. FELs are characterized by strong pulse-to-pulse intensity fluctuations due to the self-amplified spontaneous emission (SASE) process and in many experiments it is mandatory to monitor the intensity of each individual pulse. Two diamond detectors with different electrode materials, beryllium and graphite, were tested as intensity monitors at the XCS endstation of the Linac Coherent Light Source (LCLS) using the pink SASE beam at 9 keV. The performance is compared with LCLS standard monitors that detect X-rays backscattered from thin SiN foils placed in the beam. In conclusion, the graphite detector can also be used as a beam position monitor although with rather coarse resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delayed Gamma Measurements in Different Nuclear Research Reactors Bringing Out the Importance of the Delayed Contribution in Gamma Flux Calculations

Neutron and gamma flux levels are key parameters in nuclear research reactors. In Material Testing Reactors, such as the future Jules Horowitz Reactor, under construction at the French Alternative Energies and Atomic Energy Commission (CEA Cadarache, France), the expected gamma flux levels are very high (nuclear heating is of the order of 20 W/g at 100 MWth). As gamma rays deposit their energy in the reactor structures and structural materials it is important to take them into account when designing irradiation devices. There are only a few sensors which allow measurements of the nuclear heating ; a recent development at the CEA Cadarache allows measurements of the gamma flux using a miniature ionization chamber (MIC). The measured MIC response is often compared with calculation using modern Monte Carlo (MC) neutron and photon transport codes, such as TRIPOLI-4 and MCNP6. In these calculations only the production of prompt gamma rays in the reactor is usually modelled thus neglecting the delayed gamma rays. Hence calculations and measurements are usually in better accordance for the neutron flux than for the gamma flux. In this paper we study the contribution of delayed gamma rays to the total MIC signal in order to estimate the systematic error in gamma flux MC calculations. In order to experimentally determine the delayed gamma flux contributions to the MIC response, we performed gamma flux measurements with CEA developed MIC at three different research reactors: the OSIRIS reactor (MTR - 70 MWth at CEA Saclay, France), the TRIGA MARK II reactor (TRIGA - 250 kWth at the Jozef Stefan Institute, Slovenia) and the MARIA reactor (MTR - 30 MWth at the National Center for Nuclear Research, Poland). In order to experimentally assess the delayed gamma flux contribution to the total gamma flux, several reactor shut down (scram) experiments were performed specifically for the purpose of the measurements. Results show that on average about 30 % of the MIC signal is due to the delayed gamma rays. In this paper we describe experiments in each of the three reactors and how we estimate delayed gamma rays with MIC measurements. The results and perspectives are discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife{sup Registered-Sign} and linear accelerators equipped with microMLC and circular cones

Purpose: The use of small photon fields is now an established practice in stereotactic radiosurgery and radiotherapy. However, due to a lack of lateral electron equilibrium and high dose gradients, it is difficult to accurately measure the dosimetric quantities required for the commissioning of such systems. Moreover, there is still no metrological dosimetric reference for this kind of beam today. In this context, the first objective of this work was to determine and to compare small fields output factors (OF) measured with different types of active detectors and passive dosimeters for three types of facilities: a CyberKnife{sup Registered-Sign} system, a dedicated medical linear accelerator (Novalis) equipped with m3 microMLC and circular cones, and an adaptive medical linear accelerator (Clinac 2100) equipped with an additional m3 microMLC. The second one was to determine the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors introduced in a recently proposed small field dosimetry formalism for different active detectors.Methods: Small field sizes were defined either by microMLC down to 6 Multiplication-Sign 6 mm{sup 2} or by circular cones down to 4 mm in diameter. OF measurements were performed with several commercially available active detectors dedicated to measurements in small fields (high resolution diodes: IBA SFD, Sun Nuclear EDGE, PTW 60016, PTW 60017; ionizing chambers: PTW 31014 PinPoint chamber, PTW 31018 microLion liquid chamber, and PTW 60003 natural diamond). Two types of passive dosimeters were used: LiF microcubes and EBT2 radiochromic films.Results: Significant differences between the results obtained by several dosimetric systems were observed, particularly for the smallest field size for which the difference in the measured OF reaches more than 20%. For passive dosimeters, an excellent agreement was observed (better than 2%) between EBT2 and LiF microcubes for all OF measurements. Moreover, it has been shown that these passive dosimeters do not require correction factors and can then be used as reference dosimeters. Correction factors for the active detectors have then been determined from the mean experimental OF measured by the passive dosimeters.Conclusions: Four sets of correction factors needed to apply the new small field dosimetry formalism are provided for several active detectors. A protocol for small photon beams OF determination based on passive dosimeters measurements has been recently proposed to French radiotherapy treatment centers.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-C-18C-04: Evaluation of Effective Dose During Ureteroscopy for Obese and Non-Obese Patients

Purpose: Ureteroscopy involves fluoroscopy which potentially results in considerable amount of radiation dose to the patient. Purpose of this study was two-fold: (a) to develop the effective dose computational model for obese and non-obese patients undergoing left and right ureteroscopy, and (b) to evaluate the utility of a commercial Monte Carlo software for dose assessment in ureteroscopy. Methods: Organ dose measurements were performed on an adult male anthropomorphic phantom, representing the non-obese patients, with 20 high-sensitivity MOSFET detectors and two 0.18cc ionization chambers placed in selected organs. Fat-equivalent paddings were placed around the abdominal region to simulate for obese patients. Effective dose (ED) was calculated using ICRP 103 tissue weighting factors and normalized to the effective dose rate in miliSivert per second (mSv/s). In addition, a commercial Monte Carlo (MC) dose estimation program was used to estimate ED for the non-obese model, with table attenuation correction applied to simulate clinical procedure. Results: For the equipment and protocols involved in this study, the MOSFETderived ED rates for the obese patient model (‘Left’: 0.0092±0.0004 mSv/s; ‘Right’: 0.0086±0.0004 mSv/s) was found to be more than twice as much as that to the non-obese patient model (‘Left’: 0.0041±0.0003 mSv/s; ‘Right’: 0.0036±0.0007 mSv/s). The MC-derived ED rates for the non-obese patient model (‘Left’: 0.0041 mSv/s; ‘Right’: 0.0036 mSv/s; with statistical uncertainty of 1%) showed a good agreement with the MOSFET method. Conclusion: The significant difference in ED rate between the obese and non-obese patient models shows the limitation of directly applying commercial softwares for obese patients and leading to considerable underestimation of ED. Although commercial softwares offer a convenient means of dose estimation, but the utility may be limited to standard-man geometry as the software does not account for table attenuation, obese patient geometry, and differences between the anthropomorphic phantom and MC mathematical phantom.

60 APPLIED LIFE SCIENCES↗

SU-E-I-22: Dependence On Calibration Phantom and Field Area of the Conversion Factor Used to Calculate Skin Dose During Neuro-Interventional Fluoroscopic Procedures

Purpose: To determine the appropriate calibration factor to use when calculating skin dose with our real-time dose-tracking system (DTS) during neuro-interventional fluoroscopic procedures by evaluating the difference in backscatter from different phantoms and as a function of entrance-skin field area. Methods: We developed a dose-tracking system to calculate and graphically display the cumulative skin-dose distribution in real time. To calibrate the DTS for neuro-interventional procedures, a phantom is needed that closely approximates the scattering properties of the head. We compared the x-ray backscatter from eight phantoms: 20-cm-thick solid water, 16-cm diameter water-filled container, 16-cm CTDI phantom, modified-ANSI head phantom, 20-cm-thick PMMA, Kyoto-Kagaku PBU- 50 head, Phantom-Labs SK-150 head, and RSD RS-240T head. The phantoms were placed on the patient table with the entrance surface at 15 cm tube-side from the isocenter of a Toshiba Infinix C-arm, and the entrance-skin exposure was measured with a calibrated 6-cc PTW ionization chamber. The measurement included primary radiation, backscatter from the phantom and forward scatter from the table and pad. The variation in entrance-skin exposure was also measured as a function of the skin-entrance area for a 30x30 cm by 20-cm-thick PMMA phantom and the SK-150 head phantom using four different added beam filters. Results: The entranceskin exposure values measured for eight different phantoms differed by up to 12%, while the ratio of entrance exposure of all phantoms relative to solid water showed less than 3% variation with kVp. The change in entrance-skin exposure with entrance-skin area was found to differ for the SK-150 head compared to the 20-cm PMMA phantom and the variation with field area was dependent on the added beam filtration. Conclusion: To accurately calculate skin dose for neuro-interventional procedures with the DTS, the phantom for calibration should be carefully chosen since different phantoms can contribute different backscatter for identical exposure parameters. Research supported in part by Toshiba Medical Systems and NIH Grants R43FD0158401, R44FD0158402 and R01EB002873.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-210: Independent MU Dose Calculation Software for S and S IMRT Using Modified Clarkson Integration Sector

Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for S and S IMRT based in the algorithm proposed by Kung et.al. Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS and S and S IMRT modality. A 6MV photon beam produced by a Primus linear accelerator equipped with an Optifocus MLC was used. TPS dose calculation algorithms were pencil beam and Monte Carlo. 230 IMRT treatments plans were selected for the study. The software was written under MALTLAB environment. Treatment plans were imported by the software using RTP format. Field fluences were reconstructed adding all segments.The algorithm implemented in the software calculates the dose at a reference point as the sum of primary and scatter dose. The primary dose is obtained by masking the fluence map with a circle of radius 1cm. The scatter dose is obtained through a shaped ring mask around the previous circle with a thickness of 0.5cm; the rings are increased one after another with constant thickness until cover the entire map of influence. The dosimetric parameters Sc, Sp and TPR vary depending on radio, the transmission effect of the MLC, inverse square law and dose profile are used for the calculation. Results: The average difference between measured and independent calculated dose was 0.4% ± 2.2% [−6.8%, 6.4%]. For 91% of the studied plans the difference was less than 3%. The difference between the measured and TPS dose with pencilbeam algorithm was 2.6% ± 1.41% [−2.0%, 5.6%] and Monte Carlo algorithm was 0.4% ± 1.5% [−4.9%, 3.7%]. The differences obtained are comparable to that obtained with the ionization chamber and TPS. Conclusion: The developed software is suitable for use in S and S IMRT dose calculation. This application is open and can be downloading under request.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-211: Induced Release of Nanocarrier Encapsulated Chemotherapeutic Drugs Using Proton Radiotherapy Beams

Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for S and S IMRT based in the algorithm proposed by Kung et.al. Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS and S and S IMRT modality. A 6MV photon beam produced by a Primus linear accelerator equipped with an Optifocus MLC was used. TPS dose calculation algorithms were pencil beam and Monte Carlo. 230 IMRT treatments plans were selected for the study. The software was written under MALTLAB environment. Treatment plans were imported by the software using RTP format. Field fluences were reconstructed adding all segments.The algorithm implemented in the software calculates the dose at a reference point as the sum of primary and scatter dose. The primary dose is obtained by masking the fluence map with a circle of radius 1cm. The scatter dose is obtained through a shaped ring mask around the previous circle with a thickness of 0.5cm; the rings are increased one after another with constant thickness until cover the entire map of influence. The dosimetric parameters Sc, Sp and TPR vary depending on radio, the transmission effect of the MLC, inverse square law and dose profile are used for the calculation. Results: The average difference between measured and independent calculated dose was 0.4% ± 2.2% [−6.8%, 6.4%]. For 91% of the studied plans the difference was less than 3%. The difference between the measured and TPS dose with pencilbeam algorithm was 2.6% ± 1.41% [−2.0%, 5.6%] and Monte Carlo algorithm was 0.4% ± 1.5% [−4.9%, 3.7%]. The differences obtained are comparable to that obtained with the ionization chamber and TPS. Conclusion: The developed software is suitable for use in S and S IMRT dose calculation. This application is open and can be downloading under request.

60 APPLIED LIFE SCIENCES↗