Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION CURRENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Characterisation of divertor detachment onset in JET-ILW hydrogen, deuterium, tritium and deuterium–tritium low-confinement mode plasmas

Measurements of the ion currents to and plasma conditions at the low-field side (LFS) divertor target plate in low-confinement mode plasmas in the JET ITER-like wall materials configuration show that the core plasma density required to detach the LFS divertor plasma is independent of the hydrogenic species protium, deuterium and tritium, and a 40 %/60 % deuterium–tritium mixture. This observation applies to a divertor plasma configuration with the LFS strike line connected to the horizontal part of the LFS divertor chosen because of its superior diagnostic coverage. The finding is independent of the operational status of the JET cryogenic pump. The electron temperature (T e ) at the LFS strike line was markedly reduced from 25 eV to 5 eV over a narrow range of increasing core plasma density, and observed to be between 2 eV and 3 eV at the onset of detachment. The electron density (n e ) peaks across the LFS plasma when T e at the target plate is 1 eV, and spatially moves to the X-point for higher core densities. The density limit was found approximately 20 % higher in protium than in tritium and deuterium–tritium plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effects of shared peptides on protein quantitation in label-free proteomics by LC/MS/MS

Assessment of differential protein abundance from the observed properties of detected peptides is an essential part of protein profiling based on shotgun proteomics. However, the abundance observed for degenerate peptides may be due to contributions from multiple proteins that are affected differently by a given treatment. Excluding degenerate peptides eliminates this ambiguity but may significantly decrease the number of proteins for which abundance estimates can be obtained. Peptide degeneracy within a family of biologically related proteins does not cause ambiguity if family members have a common response to treatment. Based on this concept, we have developed an approach for including degenerate peptides in the analysis of differential protein abundance in protein profiling. Data from a recent proteomics study of lung tissue from mice exposed to lipopolysaccharide, cigarette smoke, and a combination of these agents is used to illustrate our method. Starting from data where about half of the protein identifications involved degenerate peptides, 82% of the affected proteins were grouped into families, based on FASTA annotation, with closure on peptide degeneracy. In many cases, a common abundance relative to control was sufficient to explain ion-current peak areas for peptides, both unique and degenerate, that identified biologically-related proteins in a peptide-degeneracy closure group. Based on these results, we propose that peptide-degeneracy closure groups provide a way to include abundance data for degenerate-peptides in quantitative protein profiling by high throughput mass spectrometry.

59 BASIC BIOLOGICAL SCIENCES↗

‘Soft’ amplifier circuits based on field-effect ionic transistors

Soft materials can be used as the building blocks for electronic devices with extraordinary properties. We introduce a theoretical model for a field-effect transistor in which ions are the gated species instead of electrons. Our model incorporates readily-available soft materials, such as conductive porous membranes and polymer-electrolytes to represent a device that regulates ion currents and can be integrated as a component in larger circuits. By means of Nernst–Planck numerical simulations as well as an analytical description of the steady-state current we find that the responses of the system to various input voltages can be categorized into ohmic, sub-threshold, and active modes. This is fully analogous to what is known for the electronic field-effect transistor (FET). Pivotal FET properties such as the threshold voltage and the transconductance crucially depend on the half-cell redox potentials of the source and drain electrodes as well as on the polyelectrolyte charge density and the gate material work function. We confirm the analogy with the electronic FETs through numerical simulations of elementary amplifier circuits in which we successfully substitute the electronic transistor by an ionic transistor.

42 ENGINEERING↗

Direct measurement of topography-dependent charging of patterned oxide/semiconductor structures

Electron shading, or topography-dependent charging, occurs during plasma exposure of wafers with high-aspect-ratio features due to an imbalance between the electron and ion currents that reach the feature bottoms. High-aspect-ratio pit structures were exposed to an electron cyclotron resonance plasma. The surface potential of the structures after plasma exposure was measured with scanning surface-potential microscopy (SSPM). The results show that SSPM can be used to measure the differential charging in a high-aspect-ratio pit. In situ depletion of the plasma-induced charge with ultraviolet radiation was time resolved using SSPM. A circuit model is used to explain the experimental results.

36 MATERIALS SCIENCE↗

A simple model of the positive ion sheath in front of a plane probe in weakly ionized electropositive plasmas

This paper describes the positive ion sheath in front of a plane probe in weakly ionized electropositive plasmas. The results obtained are the potential profile in front of the probe and the probe positive ion current to voltage characteristic curves that have been analytically fitted as a function of the probe potential and the plasma ionization rate. Finally, the floating potential for an argon plasma has been calculated by considering a parametrization of the model obtained from the fitted characteristics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optima HD Imax: Molecular Implant

Molecular implantation offers semiconductor device manufacturers multiple advantages over traditional high current ion implanters. The dose multiplication due to implanting more than one atom per molecule and the transport of beams at higher energies relative to the effective particle energies result in significant throughput enhancements without risk of energy contamination. The Optima HD Imax is introduced with molecular implant capability and the ability to reach up to 4.2 keV effective {sup 11}B from octadecaborane (B{sub 18}H{sub 22}). The ion source and beamline are optimized for molecular species ionization and transport. The beamline is coupled to the Optima HD mechanically scanned endstation. The use of spot beam technology with ionized molecules maximizes the throughput potential and produces uniform implants with fast setup time and with superior angle control. The implanter architecture is designed to run multiple molecular species; for example, in addition to B{sub 18}H{sub 22} the system is capable of implanting carbon molecules for strain engineering and shallow junction engineering. Source lifetime data and typical operating conditions are described both for high dose, memory applications such as dual poly gate as well as lower energy implants for source drain extension and contact implants. Throughputs have been achieved in excess of 50 wafers per hour at doses up to 1x10{sup 16} ions/cm{sup 2} and for energies as low as 1 keV.

36 MATERIALS SCIENCE↗

Origin of electrical signals for plasma etching endpoint detection

Electrical signals are used for endpoint detection in plasma etching, but the origin of the electrical changes observed at endpoint is not known. They may be caused by changes in the gas-phase densities of etch products and reactants or by changes in substrate surface properties such as photoemitted or ion-induced electron yield. To investigate these effects, experiments were performed in an inductively coupled, rf-biased reactor, during CF{sub 4}/Ar etches of SiO{sub 2} films on Si wafers. The rf bias impedance was measured vs. time during etching, simultaneous with Langmuir probe measurements. At endpoint, a decrease in impedance coincided with increases in ion current and electron energy. The data, analyzed by a numerical model of the discharge, indicate that changes in electron emission yield were relatively insignificant or entirely absent. Thus the impedance change is not a surface effect but is, instead, predominantly or entirely a gas-phase phenomenon.

36 MATERIALS SCIENCE↗

Development of high current Bi and Au beams for the synchrotron operation at the GSI accelerator facility

In this work, the latest results of developing high current ion beams of Au and Bi at GSI facility are described. The difficulties in the production of required charge state in vacuum arc discharge ion sources using the pure materials in the cathodes are discussed. As a possible solution, admix of a small amount of more refractory metal to the cathode material is considered. As a significant result, a dramatic improvement in the production of high charge state Bi ions using the mixed Bi-Cu cathodes (with 8%-15% of Cu admixed) compared to pure Bi cathodes is presented. The preliminary results of investigation of the material structure of Bi-Cu cathodes are discussed. As a next step, it is planned to test the composition of Au with Pd, Zr, and Fe as cathode materials.

43 PARTICLE ACCELERATORS↗

Spacer-less, decoupled granular L1{sub 0} FePt magnetic media using Ar-He sputtering gas

Spacer materials are often used to fabricate granular L1{sub 0} FePt media and reduce the grain size, however, at the expense of reduced out-of-plane coercivity. Here, we demonstrate a spacer-less method in which adding 1% helium to argon sputtering gas leads to a substantial improvement in the chemical ordering, as well as the magnetic and microstructural properties of FePt. This change is attributed to the modification in the ion current density of the plasma caused by the excited metastable helium species. Helium plays a pivotal role in providing the Fe and Pt atoms optimal adatom mobility, thereby, producing well-ordered L1{sub 0} FePt media. This leads to an enhancement of the out-of-plane coercivity from 15 to 22 kOe. Furthermore, exchange decoupled grains with a twofold reduction in their diameter to {approx}24 nm are also achieved. These properties are crucial for magnetic media of the future for data storage recording densities beyond 1 Tb/in{sup 2}.

36 MATERIALS SCIENCE↗

Experimental evidence of the increased transport due to the wall bounded magnetic drift in low temperature plasma

This paper presents experimental results on plasma transport across the magnetic field (B) in magnetized low-temperature plasma sources. Due to the presence of chamber walls, this transport can be complex even in a non-turbulent regime. In particular, in configurations without cylindrical symmetry, the magnetic drifts tend to be bounded by the chamber walls, thereby inducing plasma asymmetry and reducing magnetic confinement. In this work, we measure electron and ion current densities at metal chamber walls bounding a rectangular magnetic filter and demonstrate that these current densities are asymmetrically nonuniform. We also provide an experimental confirmation of model predictions of increased cross-field electron transport in such filter configuration, scaling as 1/B rather than the classical 1/B{sup 2} scaling.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ambipolar and non-ambipolar diffusion in an rf plasma source containing a magnetic filter

By placing a magnetic filter across a rectangular plasma source (closed at one end with a ceramic plate and an rf antenna, and terminated at the opposite end by a grounded grid), we experimentally investigate the effect of conducting and insulating source walls on the nature of the plasma diffusion phenomena. The use of a magnetic filter creates a unique plasma, characterized by a high upstream electron temperature (T{sub e{sub u}}∼5 eV) near the rf antenna and a low downstream electron temperature (T{sub e{sub d}}∼1 eV) near the grid, which more clearly demonstrates the role of the source wall materials. For conducting walls a net ion current to ground is measured on the grid, and the plasma potential is determined by a mean electron temperature within the source. For insulating walls the plasma potential is determined by the downstream electron temperature (i.e., V{sub p}∼5.2T{sub e{sub d}} in argon), and the net current to the grid is exactly zero. Furthermore, by inserting a small additional upstream conductor (that can be made floating or grounded through an external circuit switch), we demonstrate that the plasma potential can be controlled and set to a low (V{sub p}∼5.2T{sub e{sub d}}), or high (V{sub p}∼5.2T{sub e{sub u}}) value.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical matching of the sheath and presheath solutions for a spherical probe in radial-motion theory

The theory of positive-ion collection by a probe immersed in a low-pressure plasma was reviewed and extended by Allen, Boyd, and Reynolds [Proc. Phys. Soc. 70, 297 (1957)]. For a given value of the ion current, the boundary values of the matched “nonneutral” or “sheath” solution V{sup ~}{sub nn}{sup (m)}(r; r{sub m}) were obtained from the “quasineutral” or “presheath” solution V{sup ~}{sub qn}(r) by choosing the small potential and electric-field values corresponding to some large “matching radius” r{sub m}. Here, a straightforward but efficient numerical method is presented for systematically determining an optimal value of the matching radius at which the presheath and sheath solutions are joined to yield the “matched” potential profile. Some suitable initial matching radius r{sub m1} is chosen and the related potential and electric-field values of the quasineutral solution are calculated. Using these as boundary conditions, Poisson's equation is integrated to yield the matched nonneutral solution including the corresponding potential at the probe surface. This procedure is repeated for increasing values r{sub m2}, r{sub m3},…. until the resulting potential at the probe surface becomes practically constant. The corresponding value of r{sub m} is taken as the “optimal” matching radius r{sub mo} at which the presheath and sheath solutions are ultimately joined to yield the “optimal” matched potential profile in the entire plasma-probe transition region. It is also shown that the Bohm criterion is inapplicable in the present problem.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle model of full-size ITER-relevant negative ion source

This work represents the first attempt to model the full-size ITER-relevant negative ion source including the expansion, extraction, and part of the acceleration regions keeping the mesh size fine enough to resolve every single aperture. The model consists of a 2.5D particle-in-cell Monte Carlo collision representation of the plane perpendicular to the filter field lines. Magnetic filter and electron deflection field have been included and a negative ion current density of j{sub H{sup −}} = 660 A/m{sup 2} from the plasma grid (PG) is used as parameter for the neutral conversion. The driver is not yet included and a fixed ambipolar flux is emitted from the driver exit plane. Results show the strong asymmetry along the PG driven by the electron Hall (E × B and diamagnetic) drift perpendicular to the filter field. Such asymmetry creates an important dis-homogeneity in the electron current extracted from the different apertures. A steady state is not yet reached after 15 μs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a portable optical emission tomography system for microwave induced compact plasma for visible to near-infrared emission lines

A new non-invasive diagnostic system is developed for Microwave Induced Plasma (MIP) to reconstruct tomographic images of a 2D emission profile. A compact MIP system has wide application in industry as well as research application such as thrusters for space propulsion, high current ion beams, and creation of negative ions for heating of fusion plasma. Emission profile depends on two crucial parameters, namely, the electron temperature and density (over the entire spatial extent) of the plasma system. Emission tomography provides basic understanding of plasmas and it is very useful to monitor internal structure of plasma phenomena without disturbing its actual processes. This paper presents development of a compact, modular, and versatile Optical Emission Tomography (OET) tool for a cylindrical, magnetically confined MIP system. It has eight slit-hole cameras and each consisting of a complementary metal–oxide–semiconductor linear image sensor for light detection. The optical noise is reduced by using aspheric lens and interference band-pass filters in each camera. The entire cylindrical plasma can be scanned with automated sliding ring mechanism arranged in fan-beam data collection geometry. The design of the camera includes a unique possibility to incorporate different filters to get the particular wavelength light from the plasma. This OET system includes selected band-pass filters for particular argon emission 750 nm, 772 nm, and 811 nm lines and hydrogen emission H{sub α} (656 nm) and H{sub β} (486 nm) lines. Convolution back projection algorithm is used to obtain the tomographic images of plasma emission line. The paper mainly focuses on (a) design of OET system in detail and (b) study of emission profile for 750 nm argon emission lines to validate the system design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass separation of deuterium and helium with conventional quadrupole mass spectrometer by using varied ionization energy

Deuterium pressure in deuterium-helium mixture gas is successfully measured by a common quadrupole mass spectrometer (model: RGA200) with a resolution of ∼0.5 atomic mass unit (AMU), by using varied ionization energy together with new developed software and dedicated calibration for RGA200. The new software is developed by using MATLAB with the new functions: electron energy (EE) scanning, deuterium partial pressure measurement, and automatic data saving. RGA200 with new software is calibrated in pure deuterium and pure helium 1.0 × 10{sup −6}–5.0 × 10{sup −2} Pa, and the relation between pressure and ion current of AMU4 under EE = 25 eV and EE = 70 eV is obtained. From the calibration result and RGA200 scanning with varied ionization energy in deuterium and helium mixture gas, both deuterium partial pressures (P{sub D{sub 2}}) and helium partial pressure (P{sub He}) could be obtained. The result shows that deuterium partial pressure could be measured if P{sub D{sub 2}} > 10{sup −6} Pa (limited by ultimate pressure of calibration vessel), and helium pressure could be measured only if P{sub He}/P{sub D{sub 2}} > 0.45, and the measurement error is evaluated as 15%. This method is successfully employed in EAST 2015 summer campaign to monitor deuterium outgassing/desorption during helium discharge cleaning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interpretation of Lyman opacity measurements in JET with the ITER-like wall using a particle balance approach

Recent measurements of the Ly β /D α ratio in the JET ITER-like wall (ILW) divertor show comparatively more pronounced Ly β reabsorption relative to previous results in JET with the carbon wall (JET-C). At the outer horizontal target ion current rollover point a Ly β reabsorption rate of 60% is measured, increasing to 80% in more pronounced detachment, implying a Ly α reabsorption rate of 90%–98%. The radially resolved Ly β /D α measurements are used to constrain Lyman opacity corrections to atomic rate coefficients using the population escape factor technique in order to capture the local changes to the excited state population structure in the high Lyman opacity regions at and outboard of the outer strike point. To check the self-consistency of the Lyman opacity measurements, a detailed spectroscopic interpretation of the outer divertor particle balance is presented, in which the impact of opacity corrections to the Ly α inverse photon efficiency coefficients is assessed. A five-fold deficit in the estimated D + source rate obtained with optically thin plasma assumptions is reconciled once the opacity corrections are factored into the Ly α photon rate to ionization rate conversion. The experiment results are reproduced in EDGE2D-EIRENE density scan simulations in which an imposed ad hoc Lyman reabsorption rate is recovered spectroscopically using synthetic measurements, and a similar shortfall in the D + source rate estimates is reconciled using Lyman opacity corrected atomic data. The model limitations prevent a more detailed self-consistent analysis of the Lyman opacity impact on divertor parameters and detachment evolution, and hence motivate renewed efforts to re-establish routine exploitation of the photon transport modelling capabilities in the EIRENE code package. Lyman opacity corrections to atomic data coefficients are necessary for spectroscopic interpretation of the JET-ILW divertor plasma, with significant influence on the divertor plasma also a likely consequence of the presence of strong Ly α reabsorption. Finally, a scan of auxiliary heating powers spanning L-mode and H-mode conditions reveals a strong correlation of the measured Ly β opacity with the outer target temperature, suggesting new possibilities for using Lyman opacity measurements in establishing detachment scalings.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characteristics of surface glow discharge in a low-pressure supersonic gas flow

Kinetic particle-in-cell simulations are performed to examine the characteristics of the surface glow discharge in a supersonic nitrogen flow. The gas pressure is varied between 100 and 500 mTorr; the applied voltage, between -500 and -1000 V. The analysis focuses on the effect of boundary conditions at the dielectric barrier surrounding the electrodes on the electron energy distribution function. The potential on the dielectric is found by using a local balance condition for the electron and ion currents to the surface. The results of self-consistent simulations show that a negative potential on the dielectric substantially reduces the rate of high-energy electron loss from the bulk plasma and thus significantly changes the ionization rate, as well as plasma parameters and configuration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗