Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

127 Xe quantification method development and intercomparison exercise

Monitoring of the atmosphere for fission products ( 131m Xe, 133m Xe, 133 Xe, and 135 Xe) is performed by various laboratories to detect nuclear explosions. Quantification of 127 Xe is not routinely performed by laboratories measuring atmospheric radioxenon because it is not a fission product. 127 Xe was recently detected by a ground-based beta-gamma air monitoring system. When measured using beta-gamma coincidence detector systems, such as those in use on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), 127 Xe can interfere with the quantification of fission product radioxenon due to overlap of the 127 Xe beta-gamma coincidence signatures with those of fission product radioxenon. Here, this work demonstrates quantification of 127 Xe at different laboratories with different measurement techniques. Production and purification of 127 Xe was performed by neutron activation of enriched 126 Xe. The purified 127 Xe was then split between laboratories, and detection and quantification methods were developed. At Idaho National Laboratory, a quantification method involving high purity germanium detectors was devised that included self-attenuation correction. At AWE, a beta-gamma coincidence counting method, as used in support of the IMS, was modified to enable the measurement and analysis of the 127 Xe samples. Corrections were made for self-attenuation, which showed a strong xenon volume dependency, for some coincidence signatures. The gas sample activity concentration was used as the comparison metric and it showed excellent agreement between the methods.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Imaging mass spectroscopy delineates the thinned and thickened walls of intracranial aneurysms

Highlights: • Heterogeneity of IA walls was examined with imaging mass spectroscopy. • Phosphatidylinositol (PI 18:0/20:4) was more abundant in the thickened wall of IAs. • SMCs in thick and thin wall were dedifferentiated and differentiated, respectively. • Dedifferentiated SMCs had higher levels of PI (18:0/20:4) than differentiated SMCs. • PI (18:0/20:4) could be associated with phenotypic switching of SMCs in rat IAs. The wall thickness of intracranial aneurysms (IAs) is heterogeneous. Although thinning of the IA wall is thought to contribute to IA rupture, the underlying mechanism remains poorly understood. Recently, imaging mass spectroscopy (IMS) has been used to reveal the distribution of phospholipids in vascular diseases. To investigate the feature of phospholipid composition of IA walls, we conducted IMS in a rat model of experimentally induced IA.

60 APPLIED LIFE SCIENCES↗

Mass spectrometry structural analysis of intrinsically disordered phosphoproteins

Phosphorylation is a ubiquitous protein modification that is known to play important roles in many biological phenomena including cell signaling, the opening and closing of membrane protein channels, and even triggering of amyloid protein aggregation. Despite the effects phosphorylation has on protein function, the impact phosphorylation has on the structure of proteins is not well understood. Here, to determine how phosphorylation affects the structure of proteins, top-down mass spectrometry (TD-MS) and ion mobility-mass spectrometry (IM-MS) were performed on various phosphorylated proteins and their dephosphorylated proteoforms. TD-MS with collision- and electron-based fragmentation techniques was utilized to locate phosphorylation sites on the intrinsically disordered amyloid proteins β-casein and α-synuclein. TD-MS also provided evidence that alkaline phosphatase dephosphorylates β-casein from the N-terminus to the C-terminus. Furthermore, IM-MS of common phosphorylated proteins such as β-casein, α-casein, ovalbumin, and phosvitin indicates that phosphorylation promotes compaction of protein structure in denaturing as well as native conditions. Increases in abundance of more compact conformers are also observed when the disease related amyloid protein α-synuclein is phosphorylated at serine 129. We interpret the increased abundance of more compact conformers when proteins are phosphorylated as evidence that salt bridges form between negatively charged phosphates and positively charged residues, which alters protein structure. Salt bridge formation due to phosphorylation could be a mechanism for regulating protein function and be responsible for many of the phenomena observed in nature.

Amyloid proteins↗

Maximum Reasonable Radioxenon Releases from Medical Isotope Production Facilities and Their Effect on Monitoring Nuclear Explosions

Fission gases such as 133Xe are used extensively for monitoring the world for signs of nuclear testing in systems such as the International Monitoring System (IMS). These gases are also produced by nuclear reactors and by fission production of 99Mo for medical use. Recently, medical isotope production facilities have been identified as the major contributor to the background of radioactive xenon isotopes (radioxenon) in the atmosphere (Saey, et al., 2009). These releases pose a potential future problem for monitoring nuclear explosions if not addressed. As a starting point, a maximum acceptable daily xenon emission rate was calculated, that is both scientifically defendable as not adversely affecting the IMS, but also consistent with what is possible to achieve in an operational environment. This study concludes that an emission of 5×109 Bq/day from a medical isotope production facility would be both an acceptable upper limit from the perspective of minimal impact to monitoring stations, but also appears to be an achievable limit for large isotope producers.

07 ISOTOPE AND RADIATION SOURCES↗

Possible impacts of molten salt reactors on the International Monitoring System

Molten salt reactors (MSRs) are gaining support as many countries look for ways to increase power generation and replace aging nuclear energy production facilities. MSRs have inherently safe designs, are scalable in size, can burn transuranic wastes from traditional solid fuel nuclear reactors, can store excess heat in thermal reservoirs for water desalination, and can be used to produce medical isotopes as part of the real-time liquid-fuel recycling process. The ability to remove 135 Xe in real time from the fuel improves the power production in an MSR because 135 Xe is the most significant neutron-absorbing isotope generated by nuclear fission. Xenon-135, and other radioactive gases, are removed by sparging the fuel with an inert gas while the liquid fuel is recirculated from the reactor inner core through the heat exchangers. Without effective abatement technologies, large amounts of radioactive gas could be released during the sparging process. This work examines the potential impact of radioxenon releases on samplers used by the International Monitoring System (IMS) to detect nuclear explosions. Here, atmospheric transport simulations from seven hypothetical MSRs on different continents were used to evaluate the holdup time needed before release of radioxenon so IMS samplers would register few detections. Abatement technologies that retain radioxenon isotopes for at least 120 d before their release will be needed to mitigate the impacts from a molten salt breeder reactor used to replace a nuclear power plant. A holdup time of about 150 d is needed to reduce emissions to the average level of current nuclear power plants.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Modeling of fission and activation products in molten salt reactors and their potential impact on the radionuclide monitoring stations of the International Monitoring System

Molten Salt Reactors (MSRs) are one of six Generation IV reactor designs currently under development around the world. Because of the unique operating conditions of MSRs, which include molten fuel and the continuous removal of gaseous fission products during operation, work was performed to analyze the potential impact of emissions on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Simulations were performed to predict the production of IMS-relevant radionuclides in four MSR designs operating under two scenarios: (1) a sealed reactor with releases only during operational shutdown, and (2) continuous reprocessing or sparging of the fuel salt. From these production estimates the radioxenon and radioiodine signatures were extracted and compared to three current reactor designs (Pressurized Water Reactor (PWR), BWR, RBMK). In cases where continuous reprocessing of the fuel salt occurred, both the radioxenon and radioiodine signatures were nearly indistinguishable from a nuclear explosion. Estimates were also made of the potential emission rate of radioxenon for three reactor designs and it was found that MSRs have the potential to emit radioxenon isotopes at a rate of 10^15-8×10^16 Bq/d for 133Xe if no abatement is used. An assessment was made of activation products using a candidate fuel salt (FLiBe) mixed with corrosion products for the Thorium Molten Salt Reactor (TMSR-LF1).

Johnson, Christine M.↗

Projected network performance for multiple isotopes using next-generation xenon monitoring systems

Since about 2000 (Bowyer et al., 1998), radioxenon monitoring systems have been under development and testing for the verification of the Comprehensive Nuclear Test-Ban Treaty (CTBT). Operation of the systems since then has resulted in development of a next-generation of systems that are nearly ready for operational deployment. By 2010, the need to screen out civilian sources was well known (Auer et al., 2010; Saey, 2009), and isotopic ratio approaches were soon considered (Kalinowski et al., 2014) to identify specific sources. New generation systems are expected to improve the ability to verify the absence of nuclear tests by using isotopic ratios when multiple isotopes are detected. In this work, thousands of releases were simulated to compute the global detection probability of 131m Xe, 133m Xe, 133 Xe, and 135 Xe at 39 noble gas systems in the International Monitoring System (IMS) for both current and next-generation systems. Three release scenarios are defined at 1 h, 1 d, and 10 d past a 1 kt TNT equivalent 235U explosion event. Multiple cases using from one part in a million to the complete release of the xenon isotopic activity are evaluated for each scenario. Coverage maps and global integrals comparing current and next-generation monitoring systems are presented showing that next-generation noble gas systems will create measurable improvements in the IMS. The global detection probability for 133 Xe is shown to be strong in all scenarios, but only modestly improved by next-generation equipment. However, the detection probability for 131m Xe and 133m Xe increased to about 50% in different scenarios, providing a second detectable isotope for many events. As anticipated from shorter sampling intervals, the expected number of detecting samples roughly doubled and the expected number of detecting stations rose by approximately 50% for all release scenarios. Thus, it might be anticipated that future events would consist of multiple 133 Xe detections and one or more second isotope detections. In conclusion, signals of this nature should increase detection confidence, tighten release location estimates, improve rejection of civilian signals, and lessen the impacts from individual systems being offline for maintenance or repair reasons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Third international challenge to model the medium- to long-range transport of radioxenon to four Comprehensive Nuclear-Test-Ban Treaty monitoring stations

In 2015 and 2016, atmospheric transport modeling challenges were conducted in the context of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) verification, however, with a more limited scope with respect to emission inventories, simulation period and number of relevant samples (i.e., those above the Minimum Detectable Concentration (MDC)) involved. Therefore, a more comprehensive atmospheric transport modeling challenge was organized in 2019. Stack release data of Xe-133 were provided by the Institut National des Radioéléments/IRE (Belgium) and the Canadian Nuclear Laboratories/CNL (Canada) and accounted for in the simulations over a three (mandatory) or six (optional) months period. Best estimate emissions of additional facilities (radiopharmaceutical production and nuclear research facilities, commercial reactors or relevant research reactors) of the Northern Hemisphere were included as well. Model results were compared with observed atmospheric activity concentrations at four International Monitoring System (IMS) stations located in Europe and North America with overall considerable influence of IRE and/or CNL emissions for evaluation of the participants’ runs. Participants were prompted to work with controlled and harmonized model set-ups to make runs more comparable, but also to increase diversity. It was found that using the stack emissions of IRE and CNL with daily resolution does not lead to better results than disaggregating annual emissions of these two facilities taken from the literature if an overall score for all stations covering all valid observed samples is considered. A moderate benefit of roughly 10% is visible in statistical scores for samples influenced by IRE and/or CNL to at least 50% and there can be considerable benefit for individual samples. Effects of transport errors, not properly characterized remaining emitters and long IMS sampling times (12–24 h) undoubtedly are in contrast to and reduce the benefit of high-quality IRE and CNL stack data. Complementary best estimates for remaining emitters push the scores up by 18% compared to just considering IRE and CNL emissions alone. Despite the efforts undertaken the full multi-model ensemble built is highly redundant. An ensemble based on a few arbitrary runs is sufficient to model the Xe-133 background at the stations investigated. The effective ensemble size is below five. An optimized ensemble at each station has on average slightly higher skill compared to the full ensemble. However, the improvement (maximum of 20% and minimum of 3% in RMSE) in skill is likely being too small for being exploited for an independent period.

54 ENVIRONMENTAL SCIENCES↗

Source Term Analysis of Xenon (STAX): An effort focused on differentiating man-made isotope production from nuclear explosions via stack monitoring

An overview of the hardware and software developed for the Source Term Analysis of Xenon (STAX) project is presented which includes the data collection from two stack monitoring systems installed at medical isotope production facilities, infrastructure to transfer data to a central repository, and methods for sharing data from the repository with users. STAX is an experiment to collect radioxenon emission data from industrial nuclear facilities with the goal of developing a better understanding of the global radioxenon background and the effect industrial radioxenon releases have on nuclear explosion monitoring. The final goal of this work is to utilize collected data along with atmospheric transport modeling to calculate the contribution of a peak or set of peaks detected by the International Monitoring System (IMS) to provide desired discriminating information to the International Data Centre (IDC) and National Data Centers (NDCs). Types of data received from the STAX equipment are shown and collected data was used for a case study to predict radioxenon concentrations at two IMS stations closest to the Institute for RadioElements (IRE) in Belgium. The initial evaluation of results indicate that the data is very valuable to the nuclear explosion monitoring community.

07 ISOTOPE AND RADIATION SOURCES↗

Synthesis and properties of a new quadruple perovskite: A-site ordered PbMn{sub 3}Mn{sub 4}O{sub 12}

PbMn{sub 3}Mn{sub 4}O{sub 12} a quadruple perovskite was prepared by high pressure and high temperature synthesis. Powder X-ray diffraction (PXD) and differential scanning calorimetry reveal a structural phase transition at {approx}380 K. Rietveld refinement of the synchrotron room temperature data indicate rhombohedral symmetry (R-3) with a=6.43675(4) A and {alpha}=109.556(2) Degree-Sign . Similar 423 K PXD data refined in a body centered cubic cell (Im-3) with a=7.4283(9) A. The temperature variation of magnetization, shows a magnetic field dependent antiferromagnetic-like transition at 68 K, and dynamic fluctuations indicative of magnetic frustration. The semiconducting electrical behavior indicates a large decrease in the conductivity near 68 K. The temperature dependence of the real part of the dielectric constant, {epsilon}{sub real} increases dramatically at {approx}68 K, and shows relaxor-type ferroelectric behavior as a function of frequency. The intimate coupling of magnetic, electrical and dielectric properties at 68 K in PbMn{sub 3}Mn{sub 4}O{sub 12} suggests possible multiferroic behavior. - Graphical abstract: Resistance vs. temperature plot showing drastically increasing resistances at temperatures below 68 K (a). Formation of a frequency dependency of the dielectric constant between 68 K and ambient temperature (b). Sharp cusp in the magnetic susceptibility observed at 68 K which is suppressed with increasing magnetic field (c) indicates coupling of magnetic, electric and dielectric effects. Highlights: Black-Right-Pointing-Pointer PbMn{sub 3}Mn{sub 4}O{sub 12} a quadruple perovskite was prepared at high pressure. Black-Right-Pointing-Pointer A structural transition is seen at 380 K from space group R-3-to-Im-3. Black-Right-Pointing-Pointer An antiferromagnetic transition is observed at 68 K. Black-Right-Pointing-Pointer It is semiconducting with a large decrease in the conductivity near 68 K. Black-Right-Pointing-Pointer The temperature dependence of the dielectric constant increases dramatically at 68 K. Black-Right-Pointing-Pointer Coupling of magnetic, electric and dielectric behavior suggests multiferroicity.

36 MATERIALS SCIENCE↗

{pi}-{pi} Interactions and magnetic properties in a series of hybrid inorganic-organic crystals

The series of hybrid inorganic-organic solids T(Im){sub 2}[Ni(CN){sub 4}] with T=Fe, Co, Ni and Im=imidazole were prepared by soft chemical routes from aqueous solutions of the involved building units: imidazole, T{sup 2+} metal and the [Ni(CN){sub 4}]{sup 2-} anionic block. The obtained samples were characterized from infrared and UV-vis spectroscopies, and thermogravimetric, X-ray diffraction and magnetic measurements. Anhydrous solids which crystallize with a monoclinic unit cell, in the I2/a space group with four formula units per cell (Z=4) were obtained. Their crystal structure was solved ab initio from the recorded X-ray powder patterns and then refined by the Rietveld method. The metal T is found with octahedral coordination to four N ends of CN groups and two imidazole molecules while the inner Ni atom preserves its planar coordination. The system of layers remains stacked in an ordered 3D structure through dipole-dipole and {pi}-{pi} interactions between imidazole rings from neighboring layers. In this way, a pillared structure is achieved without requiring the coordination of both nitrogen atoms from imidazole ring. The recorded magnetic data indicate the occurrence of a predominant ferromagnetic interaction at low temperature for Co and Ni but not for Fe. Such magnetic ordering is more favorable for Ni with transition temperature of 14.67 K, which was ascribed to the relatively high polarizing power for this metal. Within the considered T metals, to nickel the highest electron-withdrawing ability corresponds and this leads to an increase for the metal-ligand electron clouds overlapping and to a stronger {pi}-{pi} attractive interaction, two factors that result into a higher magnetic ordering temperature. - Graphical Abstract: Magnetic ordering through the {pi}-{pi} interaction between the imidazole rings. Highlights: Black-Right-Pointing-Pointer Hybrid inorganic-organic solids. Black-Right-Pointing-Pointer Hybrid inorganic-organic molecular based magnets. Black-Right-Pointing-Pointer Ferromagnetic interaction through {pi}-{pi} stacking of imidazole rings. Black-Right-Pointing-Pointer Organic pillars formed through {pi}-{pi} stacking.

36 MATERIALS SCIENCE↗

High-pressure synthesis and relationship between A-site ordering and local structure of multicomponent perovskites (Ln{sub 0.25}Mn{sub 0.75})(Al{sub 0.25}Ti{sub 0.75})O{sub 3}, Ln=La, Pr, Nd, Sm, Gd, Tb, Dy, Y

ABSTRACT: The synthesis of multicomponent perovskites (Ln{sub 0.25}Mn{sub 0.75})(Al{sub 0.25}Ti{sub 0.75})O{sub 3} (Ln=La, Pr, Nd, Sm, Gd, Tb, Dy, Y) have been investigated using a high-pressure and high-temperature (6 GPa, 1175 °C) technique. When Ln{sup 3+} is larger La{sup 3+}, Pr{sup 3+}, Nd{sup 3+}, the A-site ordered perovskites, LnMn{sub 3}(Al{sub 0.25}Ti{sub 0.75}){sub 4}O{sub 12} in Im-3, have been successfully synthesized. The A-site partially disordered one, (Sm{sub 0.80}Mn{sub 0.20})(Sm{sub 0.07}Mn{sub 0.93}){sub 3}(Al{sub 0.25}Ti{sub 0.75}){sub 4}O{sub 12} is also obtained. In the case of smaller Gd{sup 3+}, Tb{sup 3+}, Dy{sup 3+}, we have obtained no single phase but two decomposed perovskite phases. When Ln{sup 3+} is much smaller Y{sup 3+}, it is crystallized as an A-site disorder one in Pnma. The Rietveld structural refinements of the A-site ordered and partially disordered perovskites indicate that the tilting of (Al/Ti)O{sub 6} octahedrons for the A-site ions ordering is correlated with the (Al/Ti)–O and Ln–O bond lengths to optimize the coordination of the A- and A′-sites. The phase stability of the A-site ordered perovskites is discussed from the viewpoint of this correlation. - Graphical abstract: Ln{sup 3+} (VIII) ionic radius dependence of BO{sub 6} octahedron tilt angle and A/B–O distance of Im-3 perovskites (Ln{sub 0.25}Mn{sub 0.75})(Al{sub 0.25}Ti{sub 0.75})O{sub 3} (Ln=La-Sm).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Conformal Locoregional Breast Irradiation with an Oblique Parasternal Photon Field Technique

We evaluated an isocentric technique for conformal irradiation of the breast, internal mammary, and medial supra-clavicular lymph nodes (IM-MS LN) using the oblique parasternal photon (OPP) technique. For 20 breast cancer patients, the OPP technique was compared with a conventional mixed-beam technique (2D) and a conformal partly wide tangential (PWT) technique, using dose-volume histogram analysis and normal tissue complication probabilities (NTCPs). The 3D techniques resulted in a better target coverage and homogeneity than did the 2D technique. The homogeneity index for the IM-MS PTV increased from 0.57 for 2D to 0.90 for PWT and 0.91 for OPP (both p < 0.001). The OPP technique was able to reduce the volume of heart receiving more than 30 Gy (V{sub 30}), the cardiac NTCP, and the volume of contralateral breast receiving 5 Gy (V{sub 5}) compared with the PWT plans (all p < 0.05). There is no significant difference in mean lung dose or lung NTCP between both 3D techniques. Compared with the PWT technique, the volume of lung receiving more than 20 Gy (V{sub 20}) was increased with the OPP technique, whereas the volume of lung receiving more than 40 Gy (V{sub 40}) was decreased (both p < 0.05). Compared with the PWT technique, the OPP technique can reduce doses to the contralateral breast and heart at the expense of an increased lung V{sub 20}.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of a double Time-Of-Flight detector system for accurate velocity measurement in a storage ring using laser beams

The Isochronous Mass Spectrometry (IMS) is a powerful tool for mass measurements of exotic nuclei with half-lives as short as several tens of micro-seconds in storage rings. In order to improve the mass resolving power while preserving the acceptance of the storage ring, the IMS with two Time-Of-Flight (TOF) detectors has been implemented at the storage ring CSRe in Lanzhou, China. Additional velocity information beside the revolution time in the ring can be obtained for each of the stored ions by using the double TOF detector system. In this paper, we introduced a new method of using a 658 nm laser range finder and a short-pulsed ultra-violet laser to directly measure the distance and time delay difference between the two TOF detectors which were installed inside the 10 -11 mbar vacuum chambers. Here, the results showed that the distance between the two ultra-thin carbon foils of the two TOF detectors was ranging from 18032.5 mm to 18035.0 mm over a measurable area of 20x20 mm 2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Increasing the detection sensitivity of the Radionuclide Aerosol Sampler/Analyzer using a cosmic veto system

Different configurations of a cosmic veto system have been evaluated for the Radionuclide Aerosol Sampler/Analyzer (RASA). The upgrade has the potential to resolve the issue that U.S. IMS radionuclide stations have difficulty meeting the 140Ba Minimum Detectable Concentration (MDC) certification requirement when the natural background radioactivity is high. It also aims to improve the detection sensitivity of the RASA system for other fission and activation products indicative of a nuclear explosion. This proof of principal utilizes a prototype RASA system located at Pacific Northwest National Laboratory (PNNL), and has demonstrated background reductions by up to 11.3% and improvements in the average MDC by up to 7.7%. Recommendations are made for either a 1 or 3 plate configuration, which improves the 140Ba MDC by 5.6% and 7.2% for a blank filter. Whilst elevated 212Pb activity remains problematic, the cosmic veto system provides a practical solution for sensitivity improvement with little design modification of the RASA. It also has value in improving sensitivity and preventing false-positives at remote U.S. IMS station locations where sample transfer for laboratory analysis is logistically difficult.

Comprehensive Nuclear-Test-Ban Treaty, RASA, Cosmi↗

Performance characterization of the Radionuclide Aerosol Sampler/Analyzer air sampler during a high-activity release event

The performance of the Radionuclide Aerosol Sampler/Analyzer (RASA) under high-activity conditions has been evaluated to maintain and protect the operations of International Monitoring System (IMS) radionuclide stations. Station measurements following the Fukushima Daichi accident of 11 March 2011 have been combined with laboratory measurements to understand how the quality of the measurements made using the RASA High-Purity Germanium (HPGe) gamma-spectrometer are impacted by increased sample activity and detector dead-time. Detector saturation has been identified to occur at a count rate of 175,000 counts s-1, at which level there are significant impacts to the sample live-time and detector resolution in addition to a system contamination risk. To safeguard against these effects, a dead-time limit of 16.6% is proposed that could be maintained by monitoring the activity collecting on the filter using a Cadmium Zinc Telluride (CZT) detector installed into the particulate collection area of the RASA. This limit would ensure that the IMS technical specifications for measurement time (> 20 h) and detector resolution (2.5 keV at 1332 keV) are met. The CZT would dynamically control the RASA air flow to limit the collection of particulate activity beneath the HPGe dead-time threshold and would also provide measurements useful for CTBT verification purposes and dose assessments.

Burnett, Jonathan L.↗