Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Deriving High-Resolution Reservoir Bathymetry from ICESat-2 Prototype Photon-Counting Lidar and Landsat Imagery

Knowledge of reservoir bathymetry is essential for many studies on terrestrial hydrological and biogeochemical processes. However, there are currently no cost-effective approaches to derive reservoir bathymetry at the global scale. This study explores the potential of generating high-resolution global bathymetry using elevation data collected by the 532-nm Advanced Topographic Laser Altimeter System (ATLAS) onboard the Ice, Cloud, and Land Elevation Satellite (ICESat-2). The novel algorithm was developed and tested using the ICESat-2 airborne prototype, the Multiple Altimeter Beam Experimental Lidar (MABEL), with Landsat-based water classifications (from 1982 to 2017). MABEL photon elevations were paired with Landsat water occurrence percentiles to establish the elevation-area (E-A) relationship, which in turn was applied to the percentile image to obtain partial bathymetry over the historic dynamic range of reservoir area. The bathymetry for the central area was projected to achieve the full bathymetry. The bathymetry image was then embedded onto the digital elevation model (DEM). Results were validated over Lake Mead against survey data. Results over four transects show coefficient of determination (R²) values from 0.82 to 0.99 and root-mean-square error (RMSE) values from 1.18 to 2.36 m. In addition, the E-A and elevation-storage (E-S) curves have RMSEs of 1.56 m and 0.08 km³, respectively. Over the entire dynamic reservoir area, the derived bathymetry agrees very well with independent survey data, except for within the highest and lowest percentile bands. With abundant overpassing tracks and high spatial resolution, the newly launched ICESat-2 should enable the derivation of bathymetry over an unprecedented number of reservoirs.

Yao Li↗

Global Intercomparison of hyper-resolution ECOSTRESS coastal sea surface temperature measurements from the Space Station with VIIRS-N20

The ECOSTRESS multi-channel thermal radiometer on the Space Station has an unprecedented spatial resolution of 70 m and a return time of hours to 5 days. It resolves details of oceanographic features not detectable in imagery from MODIS or VIIRS, and has open-ocean coverage, unlike Landsat. We calibrated two years of ECOSTRESS sea surface temperature observations with L2 data from VIIRS-N20 (2019–2020) worldwide but especially focused on important upwelling systems currently undergoing climate change forcing. Unlike operational SST products from VIIRS-N20, the ECOSTRESS surface temperature algorithm does not use a regression approach to determine temperature, but solves a set of simultaneous equations based on first principles for both surface temperature and emissivity. We compared ECOSTRESS ocean temperatures to well-calibrated clear sky satellite measurements from VIIRS-N20. Data comparisons were constrained to those within 90 min of one another using co-located clear sky VIIRS and ECOSTRESS pixels. ECOSTRESS ocean temperatures have a consistent 1.01 ◦C negative bias relative to VIIRS-N20, although deviation in brightness temperatures within the 10.49 and 12.01 µm bands were much smaller. As an alternative, we compared the performance of NOAA, NASA, and U.S. Navy operational split-window SST regression algorithms taking into consideration the statistical limitations imposed by intrinsic SST spatial autocorrelation and applying corrections on brightness temperatures. We conclude that standard bias-correction methods using already validated and well-known algorithms can be applied to ECOSTRESS SST data, yielding highly accurate products of ultra-high spatial resolution for studies of biological and physical oceanography in a time when these are needed to properly evaluate regional and even local impacts of climate change.

Nicolas Weidberg↗

NUV Spectroscopic Studies of Eta Car's Weigelt D across the 2003.5 Minimum

HST/STIS high dispersion, high spatial resolution spectra in the near UV (2424-2705A) were recorded of Weigelt D, located 0.25" from Eta Carinae, before, during and after the star's 2003.5 minimum. Most nebular emission, including Lyman-alpha pumped Fe II and [Fe III] lines show phase dependent variations with disappearance at the minimum and reappearance a few months later. Circumstellar absorptions increase at minimum, especially in the Fe II resonance lines originating not only from ground levels but also meta stable levels well above the ground levels. These ionization/excitation effects can be explained by a sudden change in UV flux reaching the blobs, likely due to a line-of-sight obscuration of the hotter companion star, Eta Car B, recently discovered by Iping et al. (poster, this meeting). The scattered starlight seen towards Weigelt D display noticeable different line profiles than the direct starlight from Eta Carinae. P-Cygni absorption profiles in Fe II stellar lines observed directly towards Eta Carinae, show terminal velocities up to -550 km/s. However, scattered starlight of Weigelt D display significant lower velocities ranging from -40 to -150 km/s.We interpret this result to be indicative that no absorbing Fe II wind structure exists between the Central source and Weigelt D. The lower velocity absorption appears to be connected to the outer Fe II wind structure of Eta Car A extending beyond Weigelt D intersecting the observer's line of sight. This result is consistent with the highly extended wind of Eta Car A.

Ivarsson, S.↗

Spatial Variations in Titan's Atmospheric Temperature: ALMA and Cassini Comparisons from 2012 to 2015

Submillimeter emission lines of carbon monoxide (CO) in Titan's atmosphere provide excellent probes of atmospheric temperature due to the molecule's long chemical lifetime and stable, well constrained volume mixing ratio. Here we present the analysis of 4 datasets obtained with the Atacama Large Millimeter/Submillimeter Array (ALMA) in 2012, 2013, 2014, and 2015 that contain strong CO rotational transitions. Utilizing ALMA's high spatial resolution in the 2012, 2014, and 2015 observations, we extract spectra from 3 separate regions on Titan's disk using datasets with beam sizes ranging from 0.35 ×0.28'' to 0.39 ×0.34''. Temperature profiles retrieved by the NEMESIS radiative transfer code are compared to Cassini Composite Infrared Spectrometer (CIRS) and radio occultation science results from similar latitude regions. Disk-averaged temperature profiles stay relatively constant from year to year, while small seasonal variations in atmospheric temperature are present from 2012 to 2015 in the stratosphere and mesosphere ( approx. 100-500 km) of spatially resolved regions. We measure the stratopause (320 km) to in- crease in temperature by 5 K in northern latitudes from 2012 to 2015, while temperatures rise throughout the stratosphere at lower latitudes. We observe generally cooler temperatures in the lower stratosphere ( approx. 100 km) than those obtained through Cassini radio occultation measurements, with the notable exception of warming in the northern latitudes and the absence of previous instabilities; both of these results are indicators that Titan's lower atmosphere responds to seasonal effects, particularly at higher latitudes. While retrieved temperature profiles cover a range of latitudes in these observations, deviations from CIRS nadir maps and radio occultation measurements convolved with the ALMA beam-footprint are not found to be statistically significant, and discrepancies are often found to be less than 5 K throughout the atmosphere. ALMA's excellent sensitivity in the lower stratosphere (60-300 km) provides a highly complementary dataset to contemporary CIRS and radio science observations, including altitude regions where both of those measurement sets contain large uncertainties. The demonstrated utility of CO emission lines in the submillimeter as a tracer of Titan's atmospheric temperature lays the groundwork for future studies of other molecular species -particularly those that exhibit strong polar abundance enhancements or are pressure-broadened in the lower atmosphere, as temperature profiles are found to consistently vary with latitude in all three years by up to 15 K.

Thelen, Alexander E.↗

Osiris-REx Spacecraft Current Status and Forward Plans

The NASA New Frontiers OSIRIS-REx spacecraft executed a flawless launch on September 8, 2016 to begin its 23-month journey to near-Earth asteroid (101955). The primary objective of the OSIRIS-REx mission is to collect and return to Earth a pristine sample of regolith from the asteroid surface. The sampling event will occur after a two-year period of remote sensing that will ensure a high probability of successful sampling of a region on the asteroid surface having high science value and within well-defined geological context. The OSIRIS-REx instrument payload includes three high-resolution cameras (OCAMS), a visible and near-infrared spectrometer (OVIRS), a thermal imaging spectrometer (OTES), an X-ray imaging spectrometer (REXIS), and a laser altimeter (OLA). As the spacecraft follows its nominal outbound-cruise trajectory, the propulsion, power, communications, and science instruments have undergone basic functional tests, with no major issues. Outbound cruise science investigations include a search for Earth Trojan asteroids as the spacecraft approaches the Sun-Earth L4 Lagrangian point in February 2017. Additional instrument checkouts and calibrations will be carried out during the Earth gravity assist maneuver in September 2017. During the Earth-moon flyby, visual and spectral images will be acquired to validate instrument command sequences planned for Bennu remote sensing. The asteroid Bennu remote sensing campaign will yield high resolution maps of the temperature and thermal inertia, distributions of major minerals and concentrations of organic matter across the asteroid surface. A high resolution 3d shape model including local surface slopes and a high-resolution gravity field will also be determined. Together, these data will be used to generate four separate maps that will be used to select the sampling site(s). The Safety map will identify hazardous and safe operational regions on the asteroid surface. The Deliverability map will quantify the accuracy with which the navigation team can deliver the spacecraft to and from specific sites on the asteroid surface. The Sampleability map quantifies the regolith properties, providing an estimation of how much material would be sampled at different points on the surface. The final Science Value map synthesizes the chemical, mineralogical, and geological, observations to identify the areas of the asteroid surface with the highest science value. Here, priority is given to organic, water-rich regions that have been minimally altered by surface processes. Asteroid surface samples will be acquired with a touch-and-go sample acquisition system (TAGSAM) that uses high purity pressurized N2 gas to mobilize regolith into a stainless steel canister. Although the mission requirement is to collect at least 60 g of material, tests of the TAGSAM routinely exceeded 300 g of simulant in micro-gravity tests. After acquiring the sample, the spacecraft will depart Bennu in 2021 to begin its return journey, with the sample return capsule landing at the Utah Test and Training Range on September 23, 2023. The OSIRIS-REx science team will carry out a series of detailed chemical, mineralogical, isotopic, and spectral studies that will be used to determine the origin and history of Bennu and to relate high spatial resolution sample studies to the global geological context from remote sensing. The outline of the sample analysis plan is described in a companion abstract.

Messenger, Scott↗

Post-Perihelion Volatile Production and Release from Jupiter-Family Comet 45P/Honda-Mrkos-Pajdušáková

High-resolution infrared spectra of Jupiter-family comet 45P/Honda-Mrkos-Pajdušáková were obtained with NIRSPEC at the W. M. Keck Observatory on two post- perihelion dates (UT 2017 February 13 and 19), when the comet was at heliocentric distances of 1.01 and 1.10 AU, respectively. On UT February 13, H2O was measured simultaneously with six trace parent molecules: CH3OH, C2H6, HCN, NH3, C2H2, and H2CO. On UT February 19, CH4 and CO were also targeted in addition to the species measured on UT February 13. Abundances of CO, CH4, and C2H2 relative to H2O are consistent with values obtained from IRTF/iSHELL observations of 45P in early January 2017 just after perihelion when the heliocentric distance was 0.55–0.56 AU. Differences are seen in H2CO/H2O, C2H6/H2O, CH3OH/H2O, and HCN/H2O in February compared to January. Additionally, NH3 abundances appear highly variable during the February measurements, suggesting possible fluctuations of a factor of ten; however, there is significant uncertainty in quantifying NH3 owing to the marginal detections of only one or two lines on each of the two dates. Combining all infrared spectroscopic observations of 45P in January and February 2017, a post-perihelion relationship of Q(H2O) = (2.81 ± 0.25) × 10(exp 27) [R(sub h) (sup −3.83 ± 0.18)] molecules/s is derived. However, all measurements suggest significant variability in H O production on timescales of hours and days. Compared to other comets, volatile abundances relative to H2O in 45P are as follows: CO (depleted relative to all measured comets), CH3OH (enriched/all comets), CH4 and C2H6 (typical/all comets, enriched/Jupiter-family comets), C2H2 (depleted/all comets, typical/Jupiter-family comets), H2CO (January: typical, February depleted/all comets), HCN (January: severely depleted, February: typical/Jupiter-family comets). The small geocentric distances of the comet in February 2017 provide high spatial resolution in the coma of 45P (~12 and 19 km/pixel on February 13 and 19, respectively). Overall, the spatial distributions of volatiles and dust suggest a relatively symmetric and uniform coma during the UT February 13 and 19 observations, with small spatial differences noted between some volatile species. Measured C2H2 and HCN abundances are consistent with HCN as the primary parent of CN and C2H2 as a significant but not primary parent for C2, based on C2 and CN 2017 and previous apparitions. Extracted spectra show an increase in the dust-to-gas ratio in 45P from February 13 to 19 in agreement with contemporaneous narrowband optical measurements.

Russo, Neil Dello↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

Simulation studies of a full-ring, CZT SPECT system for whole-body imaging of 99m Tc and 177 Lu

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. With the goal of filling this technological gap, we have designed a cadmium zinc telluride (CZT) full-ring SPECT scanner instrumented with a broad-energy tungsten collimator. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT does not rely on the dual- and the triple-head rotational SPECT standard paradigm, enabling a larger effective area in each scan to increase the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized phantoms filled with 99m Tc and 177 Lu. Our SPECT design can resolve 7.9 mm rods for 99m Tc (140 keV) and 9.5 mm for 177 Lu (208 keV) in a hot-rod Derenzo phantom with a 3-min exposure and reach an image contrast of 78% for 99m Tc and 57% for 177 Lu using the NEMA IQ phantom with a 6-min exposure. Our modified scatter correction shows an improved contrast-recovery ratio compared to a standard correction. In this paper, we demonstrate the good performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99m Tc imaging of brain perfusion and 123 I imaging of dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design provides similar IQ and contrast to the commercial full-ring SPECT VERITON for 99m Tc. Regarding 177 Lu imaging of the 208 keV emissions, our design provides similar contrast to that of other state-of-the-art SPECTs with a significant reduction in exposure. In conclusion, the high sensitivity and extended energy range up to 250 keV makes our SPECT design a promising alternative for clinical imaging and theranostics of emerging radionuclides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Super-resolution model for overlapping peak detection and improved spatial resolution in high-energy diffraction microscopy

Reconstruction quality in Far-field High-Energy Diffraction Microscopy (FF-HEDM) is limited by the spatial resolution of area detectors and the frequent occurrence of overlapping diffraction spots. To address these challenges, we developed a super-resolution (SR) framework using convolutional neural networks (CNNs) to recreate 2D diffraction peaks at up to ×8 resolution from raw detector data. A specialized simulation tool was created to generate synthetic training datasets with varying degrees of peak overlap. Integrated into the Microstructural Imaging using Diffraction Analysis Software (MIDAS), the SR model improves the spatial accuracy and precision of 3D grain reconstruction by an order of magnitude. This approach provides a robust solution for investigation of complex micromechanical states and material classes where the analysis is limited by the presence of overlapping peaks. Furthermore, the methodology developed here can potentially be extended to other techniques that require sub-pixel accuracy for high-fidelity data analysis.

High-energy diffraction microscopy↗

In Situ Observation of Domain Wall Lateral Creeping in a Ferroelectric Capacitor

As a promising candidate for next-generation nonvolatile memory devices, ferroelectric oxide films exhibit many emergent phenomena with functional applications, making understanding polarization switching and domain evolution behaviors of fundamental importance. However, tracking domain wall motion in ferroelectric oxide films with high spatial resolution remains challenging. Here, in this study, an in situ biasing approach for direct atomic-scale observations of domain nucleation and sideways motion is presented. By accurately controlling the applied electric field, the lateral translational speed of the domain wall can decrease to less than 2.2 Å s −1 , which is observable with atomic resolution STEM imaging. In situ observations on a capacitor structured PbZr 0.1 Ti 0.9 O 3 /La 0.7 Sr 0.3 MnO 3 heterojunction demonstrate the unique creeping behavior of a domain wall under a critical electric field, with the atomic structure of the creeping domain wall revealed. Moreover, the evolution of the metastable domain wall forms an elongated morphology, which contains a large proportion of charged segments. Phase-field simulations unveil the competition between gradient, elastic, and electrostatic energies that decide this unique domain wall creeping and morphology variation. This work paves the way toward a complete fundamental understanding of domain wall physics and potential modulations of domain wall properties in real devices.

36 MATERIALS SCIENCE↗

Probing the Nanoscale Excitonic Landscape and Confinement of Excitons in Gated Monolayer Semiconductors

Engineering and probing excitonic properties at the nanoscale remains a central challenge in quantum photonics and optoelectronics. While exciton confinement via electrical control and strain engineering has been demonstrated in 2D semiconductors, substantial nanoscale heterogeneity limits the scalability of 2D quantum photonic device architectures. Here, in this work, we use cathodoluminescence spectroscopy to probe the excitonic landscape of monolayer WS 2 under electrostatic gating. Exploiting the high spatial resolution of the converged electron beam, we resolve a homojunction arising between gated and ungated regions. Moreover, we reveal an exciton confinement channel arising from an unconventional doping mechanism driven by the interplay between the electron beam and the applied gate fields. These findings offer new insights into the optoelectronic behavior of monolayer semiconductors under the combined influence of electron-beam excitation and electrostatic gating. Our approach provides a pathway for exciton manipulation at the nanoscale and opens opportunities for controlling quantum-confined exciton transport in 2D materials.

2D materials↗

Electro-Thermal Characterization of Dynamical VO 2 Memristors via Local Activity Modeling

We report translating the surging interest in neuromorphic electronic components, such as those based on nonlinearities near Mott transitions, into large-scale commercial deployment faces steep challenges in the current lack of means to identify and design key material parameters. These issues are exemplified by the difficulties in connecting measurable material properties to device behavior via circuit element models. Here, the principle of local activity is used to build a model of VO 2 /SiN Mott threshold switches by sequentially accounting for constraints from a minimal set of quasistatic and dynamic electrical and high-spatial-resolution thermal data obtained via in situ thermoreflectance mapping. By combining independent data sets for devices with varying dimensions, the model is distilled to measurable material properties, and device scaling laws are established. The model can accurately predict electrical and thermal conductivities and capacitances and locally active dynamics (especially persistent spiking self-oscillations). The systematic procedure by which this model is developed has been a missing link in predictively connecting neuromorphic device behavior with their underlying material properties, and should enable rapid screening of material candidates before employing expensive manufacturing processes and testing procedures.

36 MATERIALS SCIENCE↗

Silicon-Lattice-Matched Boron-Doped Gallium Phosphide: A Scalable Acousto-Optic Platform

The compact size, scalability, and strongly confined fields in integrated photonic devices enable new functionalities in photonic networking and information processing, both classical and quantum. Gallium phosphide (GaP) is a promising material for active integrated photonics due to its high refractive index, wide bandgap, strong nonlinear properties, and large acousto-optic figure of merit. Here, this study demonstrates that silicon-lattice-matched boron-doped GaP (BGaP), grown at the 12-inch wafer scale, provides similar functionalities as GaP. BGaP optical resonators exhibit intrinsic quality factors exceeding 25,000 and 200,000 at visible and telecom wavelengths, respectively. It further demonstrates the electromechanical generation of low-loss acoustic waves and an integrated acousto-optic (AO) modulator. High-resolution spatial and compositional mapping, combined with ab initio calculations, indicate two candidates for the excess optical loss in the visible band: the silicon-GaP interface and boron dimers. These results demonstrate the promise of the BGaP material platform for the development of scalable AO technologies at telecom and provide potential pathways toward higher performance at shorter wavelengths.

36 MATERIALS SCIENCE↗

A Review and Perspective on Cathodoluminescence Analysis of Halide Perovskites

Halide perovskite solar cells have achieved a certified efficiency of 25.2%, surpassing CdTe and CuInGaSe 2 , which have long been regarded as the most-efficient thin-film photovoltaic materials. As this exciting class of materials continues to mature, researchers will require characterization techniques capable of exposing the interplay among structure, chemistry, and optoelectronic properties to inform processing strategies and increase both device efficiencies and long-term stability. Cathodoluminescence microscopy is an ideal technique to provide such information due to the high spatial resolution and robust optical information acquired. Here, the current body of work related to cathodoluminescence analysis of halide perovskite materials for optoelectronic applications is surveyed. This review demonstrates how cathodoluminescence can monitor degradation due to environmental stressors, phase segregation resulting from material processing, and other halide perovskite-centric material issues. A persistent concern associated with e-beam-based analysis of halide perovskites is what effect the electron beam has on the material properties being probed. Addressing this, a detailed discussion is provided on the origin of the cathodoluminescence signal and a review of studies focused on revealing changes in the properties of halide perovskites resulting from e-beam excitation. Finally, a perspective on future opportunities to expand the role of cathodoluminescence analysis for halide perovskites is provided.

14 SOLAR ENERGY↗

Small Signaling Peptides in Sorghum bicolor : Integrating Phylogeny and Gene Expression to Characterize Roles in Stem Development

Small signaling peptides (SSPs) are important regulators of plant growth, development, and responses to biotic and abiotic stress, yet their role in the C4 grass Sorghum bicolor is largely uncharacterized. To help fill this knowledge gap, 219 sorghum genes that encode SSPs were identified based on SSP sequences previously identified in Arabidopsis thaliana, Zea mays, Oryza sativa, Triticum aestivum , and Brachypodium distachyon . The 219 sorghum SSP-encoding genes were assigned to 19 gene families, analyzed for the presence of motifs, and aligned with genes that encode SSPs in other plants using phylogenetic analysis. Sorghum genes in 12 of the 19 SSP gene families had not been previously characterized. Expression of the 219 SSP-encoding genes in sorghum organs, during stem development, and in stem tissues and cell types revealed distinct spatial, temporal, and developmental patterns of expression. Genes associated with the SbCEP and SbRGF families were preferentially expressed in roots, whereas SbEPF genes were expressed in stem epidermal and pith parenchyma cells and panicles. The expression of genes during bioenergy sorghum stem growth and development was investigated because stems account for ~80% of harvested biomass and serve as conduits for water and nutrient transport between leaves and roots. During stem development, 28 SSP genes in several families ( CLE, EPF, CEP, GASS, PSY, ES, PSK, CAPE, POE ) were expressed at higher levels in zones of cell proliferation. For example, the TDIF homologs SbCLE41 and SbCLE42 were expressed at high levels in nascent stem nodes where they may regulate vascular bundle cambial activity and cell differentiation. A different set of 15 genes in the CIF, POE, CAPE, PSY, CEP, RALF , and CLE families were expressed at higher levels in zones of stem tissue differentiation highlighted by elevated expression of five SbRALFR s in the stem nodal plexus. Cell type–specific expression of many sorghum genes that encode SSPs was observed in fully elongated internodes indicating gene expression is regulated with high spatial resolution. Overall, the results provide a foundation of information for analysis of SSP function in sorghum that can be integrated with knowledge of sorghum gene regulatory networks to modulate traits important for production of sorghum crops.

bioenergy sorghum↗

Imaging Secondary Electron Emission from a Single Atomic Layer

Graphene-based devices hold promise for a wide range of technological applications. Yet characterizing the structure and the electrical properties of a material that is only one atomic layer thick still poses technical challenges. Recent investigations indicate that secondary-electron electron-beam-induced current (SE-EBIC) imaging can reveal subtle details regarding electrical conductivity and electron transport with high spatial resolution. Here, it is shown that the SEEBIC imaging mode can be used to detect suspended single layers of graphene and distinguish between different numbers of layers. Pristine and contaminated areas of graphene are also compared to show that pristine graphene exhibits a substantially lower SE yield than contaminated regions. In conclusion, this SEEBIC imaging mode may provide valuable information for the engineering of surface coatings where SE yield is a priority.

36 MATERIALS SCIENCE↗

Capturing soil moisture and salinity changes in flooded coastal forests using electrical resistivity and induced polarization

Geophysical methods provide high-resolution spatial measurements of physical quantities sensitive to changes in soil moisture and salinity and can be used to monitor soil hydrological responses to flooding. However, extracting quantitative hydrological information from geophysical data remains challenging. In this study, we extended existing petrophysical models to estimate soil moisture and salinity from electrical measurements to address this challenge. We manipulated two hydrologically isolated 2000 m 2 experimental plots by simultaneously inundating them with 265 m 3 of either freshwater or estuarine water. Repeated electrical resistivity and induced polarization measurements were used to image the water and solute infiltration along two transects that are 100 and 42 m in length. Petrophysical models derived from laboratory multi-salinity electrical measurements were used to estimate changes in soil moisture and fluid salinity from field measurements of real and imaginary conductivity during the ecosystem-scale flooding experiment. The real conductivity increased by ∼100% in the freshwater plot and ∼570% in the saltwater plot. The change in imaginary conductivity in the freshwater plot was <1 mS/m, whereas that of the estuarine water plot was ∼5 mS/m. Real conductivity shows dependence on soil moisture content with a coefficient of determination (R 2 ) > 0.7, while the imaginary conductivity shows a dependence on soil salinity with R 2 > 0.6. The results validate the use of electrical resistivity for estimating changes in soil moisture content in response to flooding. Combining electrical resistivity imaging with induced polarization measurements provides the possibility to account for changes in pore fluid conductivity.

Adebayo, Moses B. [Univ. of Toledo, OH (United Sta↗