At least 703 records · Page 39

Methodology for Automated Detection of Degradation and Faults in Packaged Air Conditioners and Heat Pumps Using Only Two Sensors

The software was created in the process of developing a system known as the Smart Monitoring and Diagnostic System (SMDS) for packaged air conditioners and heat pumps used on commercial buildings (known as RTUs). The SMDS provides automated remote monitoring and detection of performance degradation and faults in these RTUs and could increase the awareness by building owners and maintenance providers of the condition of the equipment, the cost of operating it in degraded condition, and the quality of maintenance and repair service when it is performed. The SMDS provides these capabilities and would enable conditioned-based maintenance rather than the reactive and schedule-based preventive maintenance commonly used today, when maintenance of RTUs is done at all. Improved maintenance would help ensure persistent peak operating efficiencies, reducing energy consumption by an estimated 10% to 30%.

Source record↗

Solar assisted heat pumps: A possible wave of the future

With the higher costs of electric power and the widespread interest to use solar energy to reduce the national dependence on fossil fuels, heat pumps are examined to determine their suitability for use with solar energy systems.

Smetana, F. O.↗

Pre-Commercial Scale-Up of a Gas-Fired Absorption Heat Pump

The project sought to advance the maturity of SMTI’s 80 kBTU/hr residential space and water heating GAHP from the engineering prototype stage (TRL-7) to pre-production readiness by addressing manufacturing, balance of system design and installation, cost, reliability, and field application questions. As part of this project, the project team has: (1) Matured the design package for a commercially ready product (2) Demonstrated compliance with relevant ANSI standards (3) Completed manufacturing and assembly process specifications (4) Completed total production cost estimates and capital equipment requirements (5) Initiated component and system level reliability assessments (6) Completed a small field demonstration including measured performance, installation requirements and expected costs, and customer/key stakeholder feedback. (7) Completed a Techno-economic analysis for representative applications and climate zones, including justification for utility incentive programs. (8) Completed a market intelligence report. Scope of Work: A multi-faceted project was completed that included: (a) design for manufacturing tasks for both the sealed system and balance of system, (b) development and trial of key manufacturing processes and techniques, (c) evaluation of component and system level reliability, (d) exploration of make/buy decisions including impact on cost and required capital. Additionally, (e) installation and monitoring of a small number of field test units was completed to demonstrate energy savings and collect customer/installer feedback, and (f) a focused market research task was completed to explore potential barriers and improve market introduction plans. These tasks addressed many of the remaining technical risks regarding long-term reliability, verification of manufacturing cost estimates and identification of cost concerns, identify installation and balance of system design criteria necessary to achieve energy savings and installed cost goals, and identify market barriers and strategies prior to product market introduction.

03 NATURAL GAS↗

Novel PCM Integration with Electrical Heat Pump for Demand Response

In this paper, we examine the potential for using phase change material (PCM) as a thermal storage medium for improving the efficiency as well as enabling grid-responsive control of heat pump (HP) systems. Previous research in PCM integration in buildings has primarily been focused on integration with building envelopes. An objective of our research is to design a novel and practical PCM integration with existing HP systems. High-fidelity models for building, HP and PCM are developed to facilitate the model-based predictive control (MPC) design. To optimize the operation of HP and PCM, we introduce an optimization problem considering various constraints for both comfort and hardware constraints. We include experimental results in which a house fleet are optimized to minimize their power consumption or electricity cost. We numerically demonstrate the designs potential for reducing power consumption or electricity cost by 13% or 19%, respectively.

Dong, Jin↗

An Assessment of Impacts on Electric End-Use Load Profile of a Typical Residential Building from a Ground Source Heat Pump Systems Integrated with Underground Thermal Energy Storage

Buildings are the primary users of electricity, and a considerable amount of electric energy consumed in residential and commercial buildings is for meeting thermal demands (e.g., space heating/cooling, water heating, etc.). Therefore, integrating thermal energy storage with a building’s energy system has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable power supply and the thermal demands of buildings. A novel ground-source heat pump system (GSHP) integrated with underground thermal energy storage (UTES) has been developed to enable flexible electric demand at buildings while meeting their thermal demands with an energy-efficient GSHP system. This paper assessed the potential impacts of the proposed system on the peak electrical demand and annual electricity consumption in a typical residential building at various climate zones in the United States. The results show that by replacing the conventional HVAC system (air conditioner and natural gas furnace) with the UTES integrated GSHP system, summer peak electric demand can be reduced by 27% to 50% depending on the weather. Although the winter peak electrical demand could be increased by up to 70% if the proposed system replaces natural gas furnace, the existing electricity supply system for single-family homes in most regions of the United States have adequate capacity for the replacement. While eliminating the natural gas consumption for space heating, the proposed system consumes more electricity on an annual basis in heating-dominated regions. However, it consumes less electricity in cooling dominated regions. The resulting variance in annual electricity consumption in various climate zones is within 15% compared with the baseline system.

Shi, Liang↗

Connected Thermostat Alternatives for Room Air Conditioners and Minisplit Heat Pumps

The availability of smart, connected thermostats has improved climate control, energy efficiency, and grid demand-response programs for central HVAC systems. However, a significant gap exists in addressing integrated control systems for point-source heating and cooling systems such as window air-conditioners (window ACs) and mini-split heat pumps (MSHPs). This report examines the emerging market of third-party connected thermostats tailored for these systems, focusing on their effectiveness, reliability, and potential barriers to adoption.This study evaluates several commercially available products designed for room ACs and MSHPs through a series of laboratory tests. While these infrared-based (IR-based) thermostats offer remote temperature control and scheduling via mobile apps, our findings reveal that none are seamless, with reliability of basic functions being a critical factor. Promising features include integration of indoor air quality metrics and time-of-use pricing, but the latter are not yet available in the U.S. Barriers to broad user acceptance include non-seamless setup processes, challenges in thermostat placement, and unclear product differentiation. There is a pressing need for research and development in enabling MSHPs and central thermostats to coordinate, enhancing energy savings and comfort in retrofit applications. This study underscores the importance of further innovation in connected thermostat technology to address the diverse needs of single-zone HVAC systems and promote efficient energy management in households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of Residential Air Source Heat Pump using Low–Global Warming Potential Refrigerants

We report low–global warming potential refrigerants can significantly reduce the direct emissions of CO 2 originating from HVAC systems. However, high-efficiency systems are needed to reduce indirect CO 2 emissions. In this study, an R410A residential 5-Ton heat pump was optimized using R32, R454A, R454B, R454C, and R455A. Among these options, R455A and R454C have the lowest global warming potential but have lower volumetric capacity and high glide. Optimization results using 5 mm tube heat exchangers showed 12.4% to 19.1% efficiency improvements and 13% to 33% reduction in CO 2 emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electron subband degeneracy heat pump for cryogenic cooling

An unconventional method of solid-state cryogenic cooling utilizing the electron subband degeneracy of semiconductor heterostructures is discussed in this Letter. The working principle of using the electrons as the working medium to perform cyclic heat pumping under electrostatic subband "expansion" and "compression" is discussed. The calculated base temperature can reach below dilution refrigeration temperatures with the fundamental limit set by electron-phonon interaction. Using an ultra-wide GaAs quantum well as an example, the cooling power per unit volume is estimated to reach $0.85\ \rm \mu W/cm^3$ at $25\ \rm mK$ with a hot-side temperature of $42.5\ \rm mK$, suitable for applications such as quantum computing.

Wang, Chulin↗

Comments on "The "Elevated Heat Pump" Hypothesis for the Aerosol-Monsoon Hydroclimate Link: "Grounded" in Observations?" by S. Nigam and M. Bollasina

In their recent paper Nigam and Bollasina [2010, hereafter NB] claimed to have found observational evidences that are at variance with the Elevated Heat Pump (EHP) hypothesis regarding the possible impacts of absorbing aerosols on the South Asian summer monsoon [Lau et al., 2006; Lau and Km 2006). We found NB's arguments and inferences against the EHP hypothesis flawed, stemming from a lack of understanding and an out-of-context interpretation of the hypothesis. It was argued that the simultaneous negative correlation of aerosol with rainfall, and correlations with other quantities in May as evidences against the EHP hypothesis. They cannot be more wrong in that argument. First, Lau and Kim [2006, hereafter, LKO6] never stated that the main rainfall response to EHP is in May. Second, the EHP is about responses of the entire Indian monsoon system that are non-local in space and time with respect to the aerosol forcing. Third, the correlation maps shown in NB, including the increased convection over the Bay of Bengal is not the response to EHP but rather represents the large-scale circulation that provides the build-up of the aerosols, before the onset of the monsoon rainfall over India. Because aerosol can only accumulate where there is little or no wash-out by rain, the negative correlation is a necessary condition for increased atmospheric loading of aerosols.

Lau, K. M.↗

Comment on "'Elevated Heat Pump' Hypothesis for the Aerosol-Monsoon Hydroclimate Link: 'Grounded' in Observations?" by S. Nigam and M. Bollasina

In their recent paper, Nigam and Bollasina [2010] (hereinafter NB) claimed to have found observational evidences that are at variance with the elevated heat pump (EHP) hypothesis regarding the possible impacts of absorbing aerosols on the South Asian summer monsoon [Lau et al., 2006; Lau and Kim, 2006]. We found NB's arguments and inferences against the EHP hypothesis flawed, stemming from their own out of context interpretation of the hypothesis. NB argued that the simultaneous negative correlation of aerosol with rainfall, and correlations with other quantities in May, are evidence against the EHP hypothesis. Their argument cannot be justified. First, Lau and Kim [2006] (hereinafter LK06) never stated that the main rainfall response to EHP is in May. Second, the EHP is about responses of the entire Indian monsoon system that are nonlocal in space and time with respect to the aerosol forcing. As shown in Figure 4 of LK06, while the aerosol anomalies are strongest in April-May, the strongest rainfall response is in June-July, with the enhanced rainfall fed by an induced thermally driven circulation which brings additional moisture from the ocean to the Indian subcontinent. Third, the increased rainfall over the Bay of Bengal as shown in Figure 1a of NB and the increased low-level convergence in Figure 1f of NB do not necessarily reflect responses associated with EHP but rather the large ]scale circulation that provides the buildup of the aerosols before the onset of the monsoon rainfall over India. Because aerosol can only accumulate where there is little or no washout by rain, the negative correlation is a necessary condition for increased atmospheric loading of aerosols. For the same reason, the spatial distributions of rainfall and aerosol generally are offset with each other, i.e., high aerosol in regions of low rainfall. This is evident in Figure 1, which shows the climatological mean of the MODIS aerosol optical depth (AOD), and TRMM rainfall over India in May. The maximum AOD is found over the Indo-Gangetic Plain and the desert regions of northwest India and Pakistan

Lau, K. M.↗

Heat Pump Water Heater Using Wrapped-Tank Microchannel Condenser Coil for Charge Reduction – FY19 1st Quarter (Regular) Milestone Report: Development of Wrapped-Tank Condenser Model (Round Tube and Microchannel), Coupled with Water Tank Model

We recently grew the DOE/HPDM model library to enhance its heat pump water heater (HPWH) design and simulation capability. The new additions include wrapped-tank round tube coil, microchannel coil and a one-dimensional stratified water tank. A wrapped-tank condenser coil has strong coupling with a stratified water tank, which leads HPWH simulation a transient process. The new one-dimensional stratified water tank model is an improvement to the open-source EnergyPlus water tank model, by introducing a calibration factor to account for bulk mixing effect due to water draws and circulations, etc. The wrapped-tank condenser coil model, using a segment-to-segment modeling approach to simulate round tubes or microchannel ports. The heat exchanger models can accept arbitrary refrigerant types, e.g. HFCs, HFOs, natural refrigerants like CO 2 and propane, etc.

42 ENGINEERING↗

Next Generation Refrigerants for Domestic Heat Pump Water Heaters

To select next generation refrigerants and phase out R-134a, we conducted extensive drop-in tests of multiple new refrigerants. For laboratory investigations, we performed drop-in UEF (uniform energy factor) and FHR (first hour rating) tests on two heat pump water heaters (HPWHs), one uses a 220V compressor and 40-gallon water tank, and the other uses a 120V compressor and 50-gallon tank. The alternative refrigerants/blends include R-1234yf, R-1234ze, R-515B, R-513A, and R-516A, among which R-513A is A1, non-flammable and the others are in A2L category. All the alternative refrigerants required similar optimum system charges as the baseline R-134a. They resulted in similar or better UEFs than R-134a. R-516A led to best UEFs in both the HPWHs. The resultant discharge temperatures of the new refrigerants/blends are lower than R-134a, indicating good lubricant compatibility. The 120V HPWH delivered > 60 gallons first-hour rating using R-134a. The alternatives led to reduced FHRs due to their smaller volumetric vaporization capacities using the same compressor. Except R-515B, the other refrigerants/blends delivered FHRs > 60 gallons. R-516A produced better UEFs and FHRs in both the units than the other replacements. If considering flammability, R-513A would be the best option, which has similar UEF and FHR as R-134a.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Energy Savings and Economics of Advanced Control Strategies for Packaged Heat Pumps

Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Program (BTP), evaluated a number of control strategies for packaged cooling equipment that can be implemented in an advanced controller, which can be retrofit into existing packaged heat pump units to improve their operational efficiency. This report documents the results of that analysis.

Wang, Weimin↗

Metal hydride heat pump engineering demonstration and evaluation model

Future generations of portable life support systems (PLSS's) for space suites (extravehicular mobility units or EMU's) may require regenerable nonventing thermal sinks (RNTS's). For purposes of mobility, a PLSS must be as light and compact as possible. Previous venting PLSS's have employed water sublimators to reject metabolic and equipment heat from EMU's. It is desirable for long-duration future space missions to minimize the use of water and other consumables that need to be periodically resupplied. The emission of water vapor also interferes with some types of instrumentation that might be used in future space exploration. The test article is a type of RNTS based on a metal hydride heat pump (MHHP). The task of reservicing EMU's after use must be made less demanding in terms of time, procedures, and equipment. The capability for quick turnaround post-EVA servicing (30 minutes) is a challenging requirement for many of the RNTS options. The MHHP is a very simple option that can be regenerated in the airlock within the 30 minute limit by the application of a heating source and a cooling sink. In addition, advanced PLSS's must provide a greater degree of automatic control, relieving astronauts of the need to manually adjust temperatures in their liquid cooled ventilation garments (LCVG's). The MHHP includes automatic coolant controls with the ability to follow thermal load swings from minimum to maximum in seconds. The MHHP includes a coolant loop subsystem with pump and controls, regeneration equipment for post-EVA servicing, and a PC-based data acquisition and control system (DACS).

Lynch, Franklin E.↗

Laboratory Performance Evaluation of Residential Scale Gas Engine Driven Heat Pump

Building space cooling is, and until 2040 is expected to continue to be, the single largest use of electricity in the residential sector in the United States (EIA Energy Outlook 2015 .) Increases in electric-grid peak demand leads to higher electricity prices, system inefficiencies, power quality problems, and even failures. Thermally-activated systems, such as gas engine-driven heat pump (GHP), can reduce peak demand. This study describes the performance of a residential scale GHP. It was developed as part of a cooperative research and development agreement (CRADA) that was authorized by the Department of Energy (DOE) between OAK Ridge National Laboratory (ORNL) and Southwest Gas. Results showed the GHP produced 16.5 kW (4.7 RT) of cooling capacity at 35 C (95 F) rating condition with gas coefficient of performance (COP) of 0.99. In heating, the GHP produced 20.2 kW (5.75 RT) with a gas COP of 1.33. The study also discusses other benefits and challenges facing the GHP technology such as cost, reliability, and noise.

Abu-Heiba, Ahmad↗

A Year-Round Energy-Efficient Fresh Air Handling System with Two-Stage Heat Pumps and Lake Water Pre-Treatment

Supplying fresh air is important for indoor air quality, but the energy consumption to treat fresh air is significant. The main problems in existing fresh air system include: supplying single-temperature water to treat fresh air and not applying natural energy sufficiently restrict the efficiency improvement of cooling and heat sources; unused air handling devices under most operating conditions throughout the year increase the fan energy consumption. Thus, this study proposes an efficient fresh air system that uses lake water to pre-treat fresh air and two-stage heat pumps for further treatment, and the unused air handling devices in the system are bypassed. A fresh air system in northern China is selected as a case to show the annual energy performance of the proposed system, and a comparative analysis is conducted between the proposed system and a traditional system. The results show that the annual energy-savings of the proposed system compared to the traditional system come from fans, and compressors, which are 56.5%, and 31.1%, respectively, with an entire system energy saving of 32.2%. The proposed system can achieve an annual system coefficient of performance (COP) of 5.5. This study provides potential for further improving the energy efficiency in fresh air treatment.

Liang, Chenjiyu↗