Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Evaluation of low-exergy heating and cooling systems and topology optimization for deep energy savings at the urban district level

District energy systems have the potential to achieve deep energy savings by leveraging the density and diversity of loads in urban districts. However, planning and adoption of district thermal energy systems is hindered by the analytical burden and high infrastructure costs. It is hypothesized that network topology optimization would enable wider adoption of advanced (ambient temperature) district thermal energy systems, resulting in energy savings. In this study, energy modeling is used to compare the energy performance of “conventional” and “advanced” district thermal energy systems at the urban district level, and a partial exhaustive search is used to evaluate a heuristic for the topology optimization problem. For the prototypical district considered, advanced district thermal energy systems mated with low-exergy building heating and cooling systems achieved a source energy use intensity that was 49% lower than that of conventional systems. The minimal spanning tree heuristic was demonstrated to be effective for the network topology optimization problem in the context of a prototypical district, and contributes to mitigating the problem’s computational complexity. The work presented in this paper demonstrates the potential of advanced district thermal energy systems to achieve deep energy savings, and advances to addressing barriers to their adoption through topology optimization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An optimization framework for the network design of advanced district thermal energy systems

In this work, a topology optimization framework for district thermal energy systems is presented. The framework seeks to address the questions, for a given district, "What is the best subset of buildings to connect to a district thermal energy system, and by what network should they be connected, to minimize life cycle cost?" A particle swarm optimization approach is validated to address the selection of the subset of buildings, and a graph theory-based heuristic is validated for selection of the network topology for any candidate subset of buildings. The framework is applied to a prototypical urban district for illustrative purposes. Additionally, modeling of prototypical districts revealed reductions in source energy use intensity for heating and cooling of 21-25% through the use of advanced district energy systems relative to code-compliant, building level systems. The framework identifies solutions with life cycle cost values 14% to 72% lower than that of base case scenarios based on conventional design approaches, depending on the base case scenario selected. Analysis of the search space indicates that topology optimization facilitates reductions in life cycle cost, source energy use intensity, and carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cosimulating Integrated Energy Systems With Heterogeneous Digital Twins: Matching a Connected World

Energy system integration promises in-creased resiliency and the unlocking of synergies, while also contributing to our goal of decarbonization. It is enabled by both old and new technologies, glued together with data and digital services. Hydrolyzers, heat pumps, distributed renewable generation, smart buildings, and the digital grid edge are all currently the subject of integration with the power system and the energy sector at large. To plan and operate such a multidisciplinary and multisectoral system properly, insight, tools, and expertise are all needed. Further, this is exactly where the state of the art fails to deliver: tools for integrated energy systems (IESs) are still in their infancy, and many times, even academia treats these sectors separately, producing experts in each of them but not across.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Compressor system with heat recovery

A system includes a first working fluid compressor configured to pressurize a working fluid, and a prime mover coupled to the first working fluid compressor and configured to provide a mechanical input into the first working fluid compressor. An exhaust assembly is coupled to the prime mover and is configured to receive exhaust heat from the prime mover, the exhaust assembly including a generator configured to generate electric current based on the exhaust heat received by the exhaust assembly. A second working fluid compressor includes an electric motor electrically and synchronously coupled to the generator and configured to pressurize the working fluid.

Torrey, David Allan↗

Guideline for Characterizing and Evaluating a Candidate Project Site for Solar Thermal Applications

This document presents a structured procedure for characterizing and evaluating candidate project sites for concentrating solar power (CSP) and solar heat for industrial processes (SHIP) applications. The objective is to provide project developers, researchers, and other stakeholders with a consistent, technology-agnostic framework for early-stage site assessment, enabling informed decision-making prior to significant investment in project development. Site selection is a critical factor in project success or failure for both CSP and SHIP projects. Key factors such as solar resource availability, land characteristics, environmental and regulatory constraints, infrastructure availability, and community context are determined by the choice of project site and can materially impact project performance, cost, schedule, and overall viability. This procedure is designed to systematically evaluate these factors, identify potential fatal flaws, and prioritize the most favorable candidate sites for further development. The process begins with rapid screening-level evaluation, using publicly available data to assess solar resource, land availability and suitability, zoning and land-use compatibility, and exclusion zones such as protected lands or sensitive habitats. Sites that meet the minimum screening criteria advance to a more detailed characterization. Subsequent sections of this report provide guidance for a next-level assessment of the most important technical and environmental parameters, including: 1) Solar resource quality, variability, and uncertainty using multiyear datasets and, where appropriate, on-site measurement campaigns; 2) Meteorological conditions such as wind, temperature, extreme weather events, and soiling impacts; 3) Land characteristics including slope, shading, and geotechnical conditions; and 4) Environmental and regulatory considerations, including permitting processes, endangered species, cultural resources, and visual impacts. The procedure also addresses infrastructure and integration considerations, including: 1) Grid interconnection requirements for CSP power generation projects; 2) Electrical and operational integration for SHIP facilities; 3) Water availability, quality, and permitting constraints, which are particularly critical for CSP in arid regions; and 4) Site access, construction logistics, and availability of workforce and supporting services. Recognizing the importance of social and economic context, the procedure includes evaluation of community engagement factors, such as stakeholder sentiment, proximity to sensitive visual receptors, workforce development opportunities, and local economic incentives. The outputs of these assessments are synthesized in a cost and risk evaluation, translating site characteristics into expected impacts on capital cost, operating cost, schedule, and technical risk. This is complemented by screening-level performance modeling, including 8760 simulations and long-term projections, to quantify expected energy or thermal output, assess variability thereof, and support comparison between candidate sites. Finally, the procedure provides high-level guidance on a structured go/no-go decision framework, categorizing sites based on identified risks and constraints, and outlining a clear path forward to feasibility studies and front-end engineering design for viable projects. By standardizing the site characterization process across both CSP and SHIP applications, this guideline aims to: 1) Improve consistency and transparency in early-stage project evaluation; 2) Reduce development risk and avoid investment in nonviable project sites; 3) Support collaboration between developers, researchers, and public agencies; and 4) Accelerate successful deployment of concentrating solar technologies for both power generation and industrial process heat.

14 SOLAR ENERGY↗

Effects of Downstream Vortex Generators on Film Cooling a Flat Plate Fed by Crossflow

Counter-rotating vortices, formed by the interaction of film-cooling jets and the hot gas flow, adversely affect the performance of conventional film-cooling designs. Downstream vortex generators have been shown to improve cooling effectiveness by mitigating the effects of the counter-rotating vortices and by deflecting the cooling jet laterally. In this study, computational and experimental methods were used to examine how cylindrical film-cooling holes (D = 3.2 mm, L/D = 6, p/D = 3, α = 30 deg) with and without downstream vortex generators perform when the coolant supply channel is perpendicular to the direction of the hot gas. For this study, the hot gas had a temperature of 650 K and an average Mach number of 0.23. Here, the hot-gas-to-coolant temperature ratio was 1.9, and two blowing ratios (0.75 and 1.0) were studied. Results from the computational fluid dynamics study show how crossflow affects the interaction between the film-cooling jet and hot gas flow with and without downstream vortex generators. The experimental measurements were based on infrared thermography in a conjugate heat transfer environment. Results were obtained for film-cooling performance in terms of overall effectiveness, film effectiveness, and local heat transfer coefficients. The downstream vortex generators can increase the laterally averaged effectiveness by a factor of 1.5 relative to cylindrical holes, but this higher performance is restricted to low crossflow velocities and higher blowing ratios.

17 WIND ENERGY↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Self‐Assembled NiO Nanocrystal Arrays as Memristive Elements

Abstract Memristive switching, a nonlinear current–voltage ( I – V ) characteristic, has seen a tremendous surge in interest as an approach to achieve implementation of synaptic functions. The memristive switching behavior of self‐assembled NiO nanocrystals is investigated via scanning probe microscopy, based on first‐order reversal curve current–voltage spectroscopy. Synaptic switching is clearly observed as a direct consequence of filament growth (i.e., gradually increased conductance) in the nanocrystals. A spatial dependency of the conduction in the nanocrystals suggests that there is a localization of the switching filament. The current understanding of this localization ignores features related to local lateral variation current, which can generate an excessive local heat and temperature such as electrical dissipation. The observation of low electrical dissipation at the edge of the nanocrystals shows that less energy is wasted as heat such that the bias applied can be utilized more efficiently to assist the nucleation of the filament and thus reduces the power consumption. Electrical power dissipation is also found to scale with nanocrystal height and has spatial dependence within the nanocrystals. The combination of synaptic switching and high density of the nanocrystals demonstrate that it is feasible to exploit them to create a basic architecture for neuromorphic memory devices.

Kurnia, Fran↗

Real-time dispatch optimization for concentrating solar power with thermal energy storage

Concentrating solar power (CSP) plants present a promising path towards utility-scale renewable energy. The power tower, or central receiver, configuration can achieve higher operating temperatures than other forms of CSP, and, like all forms of CSP, naturally pairs with comparatively inexpensive thermal energy storage, which allows CSP plants to dispatch electricity according to market price incentives and outside the hours of solar resource availability. Currently, CSP plants commonly include a steam Rankine power cycle and several heat exchange components to generate high-pressure steam using stored thermal energy. The efficiency of the steam Rankine cycle depends on the temperature of the plant's operating fluid, and so is a main concern of plant operators. However, the variable nature of the solar resource and the conservatism with which the receiver is operated prevent perfect control over the receiver outlet temperature. Therefore, during periods of solar variability, collection occurs at lower-than-design temperature. To support operator decisions in a real-time setting, we develop a revenue-maximizing non-convex mixed-integer, quadradically-constrained program which determines a dispatch schedule with sub-hourly time fidelity and considers temperature-dependent power cycle efficiency. The exact nonlinear formulation proves intractable for real-time decision support. Here we present exact and inexact techniques to improve problem tractability that include a hybrid nonlinear and linear formulation. Our approach admits solutions within approximately 3% of optimality, on average, within a five-minute time limit, demonstrating its usability for decision support in a real-time setting.

14 SOLAR ENERGY↗

Comparative Analysis of Natural Gas Cogeneration Incentives on Electricity Production in Latin America

An analysis to assess the influence of country-dependent variables and incentives on the feasibility of natural gas cogeneration projects in Latin America is presented in this work. The analysis is performed using a hypothetical industrial plant, where the cogeneration solution consists in the recovery of waste heat from the power generation for steam production. The feasibility is evaluated by calculating the Return of Investment (ROI) and the Internal Rate of Return (IRR) of the project. Eight Latin American countries are studied considering their specific natural gas markets, regulation, and macroeconomic variables. Two scenarios, electricity production for self-consumption and electricity production with power surplus sale, are independently analyzed considering the effects of available incentives. In the countries where the project is feasible, the application of incentives leads to a significant reduction in the ROI and, consequently, to an increment in the IRR. The effect of the interest rate and environmental impact were also analyzed. In general terms, along the region, the regulation for cogeneration is incipient while incentives are very standard and similar respect to lowering of import, Value-Added Tax (VAT), and income taxes, which seems to be designed purely to promote capital investment. Following the results from this study, it is of paramount importance to create new policy instruments in the future to advance the regulatory framework for cogeneration in Latin America.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Life cycle analysis of a hydrogen production system based on solid oxide electrolysis cells integrated with different energy and wastewater sources

Hydrogen production via water electrolysis is a promising and evolving technology. The solid oxide electrolysis cell (SOEC) is one of the several technologies for this purpose. They are alternatives to the traditional hydrogen production from fossil fuels to enhance global energy decarbonization. However, in the bid for sustainability and a green economy, these technologies are not free from causing some environmental burdens. Using life cycle assessment (LCA), the greenhouse gas emission and degree of environmental impacts by these technologies can be identified and measured throughout their lifespan. This study addresses how to quantify these CO 2 emission impacts for an electrolytic system with different energy sources. The LCA of a novel integrated hydrogen production SOEC system with energy from solar photovoltaic and bituminous powerplant is performed using simaPro, the leading global LCA solution software. Measuring the environmental impact of the electrolytic operation in terms of weight, the bituminous powerplant poses damage which is, on average 700% more than solar PV. The thermal-to-hydrogen efficiency of the SOEC system is 56%, and a probable 28% reduction in carbon footprint with heat integration. The steam generation and the manufacturing of the SOEC have a very high environmental impact potential on the system. Here, we recommend LCA and net energy analysis is carried out for every new hydrogen technology and adequate comparison to enhance sustainable and green economy.

08 HYDROGEN↗

Trends and limits of CO 2 capture in solid and liquid sorbents at standard conditions

Carbon capture and storage (CCS) plays a critical role in achieving climate change mitigation targets, offering a pathway to decarbonize power generation, industrial processes, and heat production while addressing atmospheric CO 2 removal. While CCS technologies are technically advanced, the widespread adoption of 100 % CO 2 capture capacities such as 1 mol of CO 2 /mol of material and 1 g CO 2 /g storage (targeted by the DARPA, Defense Sciences Office, USA Govt.) has raised questions about the feasibility of achieving higher capture capacities. In the context of limiting global warming to 1.5°C, reaching 100 % CO 2 capture capacity is increasingly necessary, with residual emissions requiring complementary carbon dioxide removal (CDR) technologies. This review exclusively focuses on the CO 2 capture capacities of various sorbents under standard conditions, using different evaluation metrics. This study explores the performance of solid and liquid sorbents under standard conditions, analyzing factors including surface area, pore structure, solvent type, and functionalization to identify materials optimized for industrial-scale CCS applications. Emerging sorbents, including ILs, MOFs, COFs, POPs, DES, RCC, hybrid materials, and reactive sorbents, offer significant potential for enhanced selectivity and energy-efficient regeneration. Through a systematic assessment of gravimetric, volumetric, and molar capacities, the study provides insights into material efficiencies and trade-offs, offering guidance on optimizing sorbent selection for specific applications. The research advances understanding of scalable CCS technologies, contributing to global efforts to achieve net-zero emissions and address the pressing challenge of climate change.

Absorption↗

Validation study of sodium pool fire modeling efforts in $\mathrm{MELCOR}$ and $\mathrm{SPHINCS}$ codes

Discharge of sodium coolant into containment from a sodium-cooled fast reactor vessel can occur in the event of a pipe leak or break. In this situation, some of the liquid sodium droplets discharged from the coolant system will react with oxygen in the air before reaching the containment. This phase of the event is normally termed the sodium spray fire phase. Unreacted sodium droplets pool on the containment floor where continued reaction with containment atmospheric oxygen occurs. This phase of the event is normally termed the sodium pool fire phase. Both phases of these sodium-oxygen reactions (or fires) are important to model because of the heat addition and aerosol generation that occur. Any fission products trapped in the sodium coolant may also be released during this progression of events, which if released from containment could pose a health risk to workers and the public. The paper describes progress of an international collaborative research in the area of the sodium fire modeling in the sodium-cooled fast reactors between the United States and Japan under the framework of the Civil Nuclear Energy Research and Development Working Group. In this collaboration between Sandia National Laboratories and Japan Atomic Energy Agency, the validation basis for and modeling capabilities of sodium spray and pool fires in MELCOR of Sandia National Laboratories and SPHINCS of Japan Atomic Energy Agency are being enhanced. Here this study documents MELCOR and SPHINCS sodium pool fire model validation exercises against the JAEA’s sodium pool fire experiments, F7-1 and F7-2. The proposed enhancement of the sodium pool fire models in MELCOR through addition of thermal hydraulic and sodium spreading models that enable a better representation of experimental results is also described.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermomechanical analysis and modeling of a high-temperature light trapping planar cavity solar receiver

The development of durable particle-based high-temperature solar receivers is critical for advancing concentrating solar-thermal (CST) technologies to enable high-efficiency power generation and industrial process heat. Here, this study presents a computational framework to evaluate the thermomechanical performance of a proposed enclosed light-trapping planar cavity receiver designed for particle-based thermal energy systems. The receiver incorporates absorptive cavities and fluidized particle-bed channels to enhance heat capture and reduce thermal losses. Finite element analysis (FEA) is employed to assess stress, strain, and creep-fatigue behavior under concentrated solar flux using realistic thermal boundary conditions derived from coupled system models and experimental assembly parameters. The analysis investigates the influence of particle-to-wall heat transfer coefficients (HTC) ranging from 800 to 1800 W/m 2 .K on the thermomechanical response of six candidate high-temperature alloys: Alloy 740H, Alloy 282, Alloy 617, 316H, Alloy 230, and 800H. Results show that increasing HTC reduces thermal gradients, leading to lower stresses and strains and extended minimum predicted creep life. While all materials satisfy fatigue life requirements under the investigated conditions, significant differences in creep resistance are observed. Alloy 740H consistently exhibits the longest minimum predicted creep life and the most favorable durability margins, followed by Alloy 282, with the remaining materials showing reduced creep resistance under identical loading. The reported creep lives are conservative lower-bound estimates intended for comparative material evaluation. This framework highlights the critical roles of material selection and geometry optimization in improving mechanical durability and reliability of solar-thermal receivers, forming a foundation for future experimental validation and design optimization.

14 SOLAR ENERGY↗

High-Temperature Ferrofluids Based on Molten Salts

Molten metal chloride salts are promising candidates for advanced heat transfer fluids in generation IV nuclear reactors and beyond. However, research on the magnetic properties of suspended metallic nanoparticles at elevated temperatures is scarce, and there have been no attempts to develop a high-temperature, molten salt based ferrofluid. Such a ferrofluid would enable in situ manipulation of both the physical and thermal properties of the fluid via an external magnetic field. This study examines molten salt based ferrofluids comprised of metallic cobalt nanoparticles dispersed in molten metal chloride salts. High-temperature magnetometry and magneto-thermogalvometric measurements were conducted to evaluate the magnetic characteristics of the ferrofluid. Further analysis was conducted through a combination of microscopy, spectroscopy, solubility tests, and diffraction measurements. Furthermore, the metallic cobalt nanoparticles exhibited a notable degree of chemical stability and sustained magnetism from 25 to 800 °C when suspended in NaCl–MgCl 2 and KCl–ZnCl 2 mixtures.

Cobalt↗

Nanocrystal-to-Ligand Interfacial Thermal Transport: Plasmonic Indium Tin Oxide to Perylene Diimide Adsorbates

The generation and dissipation of heat in nanocrystals upon optical excitation is a process which may either limit or enhance their performance in certain applications. Using transient absorption spectroscopy, we tracked the flow of heat from plasmonic tin-doped indium oxide (ITO) nanocrystals to surface adsorbed perylenediimide (PDI) molecules upon excitation of the ITO near-infrared plasmon resonance. Here, we rationalize the derivative line shapes observed in the transient absorption bleach features are the result of thermal transfer from the ITO core to surface ligands based on temperature-dependent static absorption studies of the PDI molecules adsorbed on plasmonic ITO. Through a series of pump power dependent measurements, we demonstrate that the PDI heating time is largely fluence independent at the powers measured, while the overall recovery time increases. Elucidating thermal transfer rates at the nanocrystal and organic ligand interface is key for applications such as plasmon mediated photocatalysis, where heating may obfuscate hot carrier transfer processes.

heat dissipation↗

The Impact of Radiative Transfer at Reduced Spectral Resolution in Large‐Eddy Simulations of Convective Clouds

Abstract Many radiative transfer schemes approximate the spectral integration over ∼10 5 to ∼10 6 wavelengths with correlated k ‐distributions methods that typically require only 10 1 –10 2 spectral integration points ( g ‐points). The exact number of g ‐points is then chosen as an optimal balance between computational costs and accuracy, normally assessed in terms of a number of radiative quantities. How this radiative accuracy propagates to simulation accuracy, however, is not straightforward. In this study, we therefore explore the sensitivity of cloud properties in large‐eddy simulations (LES) to the accuracy of radiative fluxes and heating rates. We first generate smaller sets of g ‐points from existing k ‐distributions by repeatedly combining adjacent g ‐points while maintaining the highest possible accuracy on a chosen set of radiative metrics. Next, we perform three sets of LES with varying cloud—radiation coupling pathways, and therefore different requirements for the accuracy of the radiative transfer computations, to investigate how these smaller and thus less accurate k ‐distributions affect simulation characteristics. The decrease in radiative accuracy with 3–4 times smaller k ‐distributions results in biases in cloud properties that are relative small compared to their temporal fluctuations. These results show potential for speeding up radiative transfer computations in cloud‐resolving models by reducing the resolved spectral detail. However, more statistically converged simulations and a wider set of case studies is required to fully assess the robustness of our results.

Meteorology & Atmospheric Sciences↗