Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

SU-E-T-117: Analysis of the ArcCHECK Dosimetry Gamma Failure Using the 3DVH System

Purpose: To evaluate gamma analysis failure for the VMAT patient specific QA using ArcCHECK cylindrical phantom. The 3DVH system(Sun Nuclear, FL) was used to analyze the dose difference statistic between measured dose and treatment planning system calculated dose. Methods: Four case of gamma analysis failure were selected retrospectively. Our institution gamma analysis indexes were absolute dose, 3%/3mm and 90%pass rate in the ArcCHECK dosimetry. The collapsed cone convolution superposition (CCCS) dose calculation algorithm for VMAT was used. Dose delivery was performed with Elekta Agility. The A1SL(standard imaging, WI) and cavity plug were used for point dose measurement. Delivery QA plans and images were used for 3DVH Reference data instead of patient plan and image. The measured data of ‘.txt’ file was used for comparison at diodes to acquire a global dose level. The,.acml’ file was used for AC-PDP and to calculated point dose. Results: The global dose of 3DVH was calculated as 1.10 Gy, 1.13, 1.01 and 0.2 Gy respectively. The global dose of 0.2 Gy case was induced by distance discrepancy. The TPS calculated point dose of was 2.33 Gy to 2.77 Gy and 3DVH calculated dose was 2.33 Gy to 2.68 Gy. The maximum dose differences were −2.83% and −3.1% for TPS vs. measured dose and TPS vs. 3DVH calculated respectively in the same case. The difference between measured and 3DVH was 0.1% in that case. The 3DVH gamma pass rate was 98% to 99.7%. Conclusion: We found the TPS calculation error by 3DVH calculation using ArcCHECK measured dose. It seemed that our CCCS algorithm RTP system over estimated at the central region and underestimated scattering at the peripheral diode detector point. The relative gamma analysis and point dose measurement would be recommended for VMAT DQA in the gamma failure case of ArcCHECK dosimetry.

60 APPLIED LIFE SCIENCES↗

SU-E-T-231: Cross-Validation of 3D Gamma Comparison Tools

Purpose: Moving the computational analysis for 3D gel dosimetry into the 3D Slicer (www.slicer.org) environment has made gel dosimetry more clinically accessible. To ensure accuracy, we cross-validate the 3D gamma comparison module in 3D Slicer with an independently developed algorithm using simulated and measured dose distributions. Methods: Two reference dose distributions were generated using the Varian Eclipse treatment planning system. The first distribution consisted of a four-field box irradiation delivered to a plastic water phantom and the second, a VMAT plan delivered to a gel dosimeter phantom. The first reference distribution was modified within Eclipse to create an evaluated dose distribution by spatially shifting one field by 3mm, increasing the monitor units of the second field, applying a dynamic wedge for the third field, and leaving the fourth field unchanged. The VMAT plan was delivered to a gel dosimeter and the evaluated dose in the gel was calculated from optical CT measurements. Results from the gamma comparison tool built into the SlicerRT toolbox were compared to results from our in-house gamma algorithm implemented in Matlab (via MatlabBridge in 3D Slicer). The effects of noise, resolution and the exchange of reference and evaluated designations on the gamma comparison were also examined. Results: Perfect agreement was found between the gamma results obtained using the SlicerRT tool and our Matlab implementation for both the four-field box and gel datasets. The behaviour of the SlicerRT comparison with respect to changes in noise, resolution and the role of the reference and evaluated dose distributions was consistent with previous findings. Conclusion: Two independently developed gamma comparison tools have been cross-validated and found to be identical. As we transition our gel dosimetry analysis from Matlab to 3D Slicer, this validation serves as an important test towards ensuring the consistency of dose comparisons using the 3D Slicer environment.

60 APPLIED LIFE SCIENCES↗

SU-E-T-441: Gamma Passing Rates for IMRT QA and VMAT QA

Purpose: This study compares gamma passing rates for a cohort of similar intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) quality assurance (QA) plans to determine the equivalence of the patient specific QA plan delivery. The passing criterion is 90% gamma index with 3% dose difference (DD), 3mm distance-to-agreement (DTA) and a dose threshold of 10%. Methods: Gamma passing results of previously treated IMRT QA plans, delivered to Sun Nuclear MapCheck phantom, and VMAT QA plans, delivered to ScandiDos Delta4 phantom, are organized by anatomical site and treatment machine. Both Varian and Elekta machines are included. Pairs of IMRT and VMAT plans are matched based on site, machine, and PTV volume to ensure similar plan cohorts. A two-tailed t-test analysis of the data with an alpha of 0.05 determines if there exists a statistically significant difference. Power was calculated to detect a difference of 4%; all data sets were strong with above a 0.8 power. Results: The first data set consisting of 20 matched pairs of prostate plans was statistically insignificant (p-value=0.90, Power=0.99). The 14 matched pairs set of head and neck plans has a statistically significant Result (p-value=0.028, Power=0.88). The head and neck IMRT gamma indexes have a mean of 93.1% and range of 82%-100% while the VMAT gamma indexes have a mean of 96.7% and range of 92%-100%. The two combined data sets of matched plans had a statistically insignificant Result (p-value=0.073, Power=0.99). Conclusion: Overall, IMRT and VMAT have equivalent passing rates when comparing the gamma analysis using a passing criterion of 3% DD and 3mm DTA. When separated by site, prostate IMRT and VMAT plans have equivalent passing rates while head and neck plans have a statistically significant variation of passing rates. The passing rates for the two modalities are independent of delivery machine for matched PTV target volumes.

60 APPLIED LIFE SCIENCES↗

SU-F-T-294: The Analysis of Gamma Criteria for Delta4 Dosimetry Using Statistical Process Control

Purpose: To evaluate the sensitivity of gamma criteria for patient-specific volumetric modulated arc therapy(VMAT) quality assurance of the Delta{sup 4} dosimetry program using the statistical process control(SPC) methodology. Methods: The authors selected 20 patient-specific VMAT QA cases which were undertaken MapCHECK and ArcCHECK with gamma pass rate better than 97%. The QAs data were collected Delta4 Phantom+ and Elekta Agility six megavolts without using an angle incrementer. The gamma index(GI) were calculated in 2D planes with normalizing deviation to local dose(local gamma). The sensitivity of the GI methodology using criterion of 3%/3mm, 3%/2mm and 2%/3mm was analyzed with using process acceptability indices. We used local confidence(LC) level, the upper control limit(UCL) and lower control limit(LCL) of I-MR chart for process capability index(Cp) and a process acceptability index (Cpk). Results: The lower local confidence levels of 3%/3mm, 3%/2mm and 2%/3mm were 92.0%, 83.6% and 78.8% respectively. All of the calculated Cp and Cpk values that used LC level were under 1.0 in this study. The calculated LCLs of I-MR charts were 89.5%, 79.0% and 70.5% respectively. These values were higher than 1.0 which means good quality of QA. For the generally used lower limit of 90%, we acquired over 1.3 of Cp value for the gamma index of 3%/3mm and lower than 1.0 in the rest of GI. Conclusion: We applied SPC methodology to evaluate the sensitivity of gamma criteria and could see the lower control limits of VMAT QA for the Delta 4 dosimetry and could see that Delta 4 phantom+ dosimetry more affected by the position error and the I-MR chart derived values are more suitable for establishing lower limits. Acknowledgement: This research was supported by Basic Science Research Program through the National Research Foundation of Korea(NRF) funded by the Ministry of Education (No. 2015R1D1A1A01060463)

60 APPLIED LIFE SCIENCES↗

Neurogenic Effects of Low-Dose Whole-Body HZE (Fe) Ion and Gamma Irradiation

Understanding the dose-toxicity profile of radiation is critical when evaluating potential health risks associated with natural and man-made sources in our environment. This study was done to evaluate the effects of low-dose whole-body high-energy charged (HZE) iron (Fe) ions and low-energy gamma exposure on proliferation and differentiation of adult-born neurons within the dentate gyrus of the hippocampus, cells deemed to play a critical role in memory regulation. To determine the dose-response characteristics of the brain to whole-body Fe-ion vs. gamma-radiation exposure, C57BL/6J mice were irradiated with 1 GeV/n Fe ions or a static 137 Cs source (0.662 MeV) at doses ranging from 0 to 300 cGy. The neurogenesis was analyzed at 48 h and one month postirradiation. These experiments revealed that whole-body exposure to either Fe ions or gamma radiation leads to: 1. An acute decrease in cell division within the dentate gyrus of the hippocampus, detected at doses as low as 30 and 100 cGy for Fe ions and gamma radiation, respectively; and 2. A reduction in newly differentiated neurons (DCX immunoreactivity) at one month postirradiation, with significant decreases detected at doses as low as 100 cGy for both Fe ions and gamma rays. The data presented here contribute to our understanding of brain responses to whole-body Fe ions and gamma rays and may help inform health-risk evaluations related to systemic exposure during a medical or radiologic/nuclear event or as a result of prolonged space travel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Functional Bounding Content Envelope for Gamma and Neutron Emitting Isotopes in the Model 9977 Packaging

The contents approved for shipment in a Type B radioactive material transportation package have historically been descriptions of discrete items, or groupings of well-defined similar items, in the package safety basis documentation. The need for a comprehensive functional content envelope of both gamma and neutron emitting nuclides compliant with regulatory limits has become necessary as the DOE complex requires shipments of unique mixtures of radionuclides and impurities. Recent publications have presented a calculational model and a corresponding content envelope intended to be compliant with federal regulatory external radiation limits as well as design decay heat limits based on the Model 9977 Packaging. The methodology used to develop this content envelope consisted of determining the external radiation dose rates based on one gram of a given isotope combined, in the case of actinides, with various levels of light element impurities and determining the allowable mass to the regulatory limits based on these dose rates. The method of ratioing from these calculations to the masses that meet the regulatory limits fails in the case of some combinations of actinides and light element impurities because of the effect of subcritical multiplication, resulting in non-conservative and non-compliant dose rates in some cases. This is particularly true for many actinides combined with beryllium, boron, fluorine, lithium, and sodium. In this study, the source was modeled as a sphere with the appropriate dimensions based on the actinide or gamma source density and placed at the bottom of the containment vessel for maximum conservatism. The results presented in this report rectify the above-noted deficiencies by adjusting the previously determined mass limits so that the resulting dose rates are compliant with regulatory limits. Some amount of iteration was required in some instances to adjust the masses for dose compliance. In some instances the masses were increased since they were too conservative. In addition, the method of ratioing the masses when applied to several gamma emitting isotopes also resulted in either non-conservative or overly conservative data. The mass imits presented here are for bare sources and are complaint with the design decay heat limit of 19W. The masses are based on package surface dose rates (the limiting dose rate) that fall in the range 185-195 mrem/h, thus giving an additional margin of between 7.5% and 2.5% to the regulatory limit of 200 mrem/h. This report presents a revised set of mass limits (i.e., content envelope) for several neutron emitting actinides with varying levels of light element impurities compliant with both external radiation and design decay heat limits. In addition, revised limits for gamma sources are also presented. The neutron emitter mass limits are in Tables 1 through 9 and the gamma emitter mass limits are in Table 10. The revised content envelope covering a wide range of materials present in the DOE complex, was developed for the Model 9977 Packaging, providing conservative limits for other commonly-used Type B Packagings such as the Models 9975 and 9978. It should be noted that for the Model 9977 package, shipment is also possible with three shielded containers – lead or tungsten for gamma sources and polyethylene for neutron emitters. The design decay heat limits for these are as follows: 19W for tungsten, 6W for lead and 3W for polyethylene. The limits presented in this report would need to be checked against the lower decay heat limits for the lead and polyethylene and adjusted as required for compliance. Criticality safety is not factored into these limits and should be evaluated on a case by case basis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Precision Gamma-Ray Branching Ratios for Long-Lived Radioactive Nuclei

Many properties of the high-energy-density environments in nuclear weapons tests, advanced laser-fusion experiments, the interior of stars, and other astrophysical bodies must be inferred from the resulting long-lived radioactive nuclei that are produced. These radioactive nuclei are most easily and sensitively identified by studying the characteristic gamma rays emitted during decay. Measuring a number of decays via detection of the characteristic gamma-rays emitted during the gamma-decay (the gamma-ray branching ratio) of the long-lived fission products is one of the most straightforward and reliable ways to determine the number of fissions that occurred in a nuclear weapon test. The fission products 147 Nd, 144 Ce, 156 Eu, and certain other long-lived isotopes play a crucial role in science-based stockpile stewardship, however, the large uncertainties (about 8%) on the branching ratios measured for these isotopes are currently limiting the usefulness of the existing data [1,2]. We performed highly accurate gamma-ray branching-ratio measurements for a group of high-atomic-number rare earth isotopes to greatly improve the precision and reliability with which the fission yield and reaction products in high-energy-density environments can be determined. We have developed techniques that take advantage of new radioactive-beam facilities, such as DOE's CARIBU located at Argonne National Laboratory, to produce radioactive samples and perform decay spectroscopy measurements. The absolute gamma-ray branching ratios for 147 Nd and 144 Ce are reduced <2% precision. In addition, high-energy monoenergetic neutron beams from the FN Tandem accelerator in TUNL at Duke University was used to produce 167 Tm using the 169 Tm(n,3n) reaction. Fourtime improved branching ratio of 167 Tm is used now to measure reaction-in-flight (RIF) neutrons from a burning DT capsule at NIF [10]. This represents the first measurement of RIF neutrons in any laboratory fusion system, and the magnitude of the signal has important implications for fundamental plasma science and for weapons physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of Gamma Dose Rate Calculation Methodology using the Morris and Turkey Point Measurements

The ability to accurately predict the dose rates from the spent nuclear fuel assembly is very important for determining whether the used nuclear fuel is self-guarded and self-protected. Studies have shown that the direct numerical calculations of the dose rates gave a much lower value than a typical reference. This report summarizes the benchmark studies performed to evaluate the numerical methodologies used in calculating the gamma dose rates of the spent nuclear fuel assemblies. The Morris and Turkey Point experimental data for dose rates measured through air were used in the analyses. Numerical simulations of the gamma dose rate measurements included the fuel depletion analysis of the fuel assembly as well as its structural materials irradiated inside the reactor core, the radioisotopes decay, and photon transport simulations to calculate the gamma dose rates. The different factors which affect the calculated gamma dose rates were addressed. The calculated results were compared with the measured gamma dose rates. Good agreement was obtained when the detectors were placed at the middle of the fuel assembly region. The deviations of the calculated dose rates became larger when the measurements were performed at the top or bottom fuel assemblies. In these benchmark studies, the spent nuclear fuel assemblies were all PWR assemblies and had fuel burnup around 25 MWd/kg to 40 MWd/kg. Its cooling time before the measurements was around 1.8 years to 7 years. The used nuclear fuel assembly is usually self-protected while discharged from the core. Its radioactivity decreases and after a few tens of years it may fall down below the current threshold of 100 r/h. Future validation work is necessary in order to better evaluate the numerically calculated gamma dose rates with experiments performed for other types of fuel assemblies and for fuel assemblies with higher burnup and/or longer cooling times.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Report to NCSP on 2008 DANCE measurements of 233 U($\eta$,$\gamma$)

Uranium-233 plays an important role in the Th-U fuel cycle, with substantial production in the cycle. This cycle has been proposed as an alternative to the U-Pu fuel cycle due to its reduced production of transuranic elements. An accurate measurement of the 233 U($\eta$,$\gamma$) cross section is required by the National Criticality Safety Program (NCSP) to complete the neutron-induced cross section data, where experimental capture cross section data are scarce and were measured decades ago. The most recent capture cross section data available in the literature were measured in 2007 at the n_TOF facility (CERN); in the 60s measurements were performed at Rensselaer Polytechnic Institute (RPI) and at LANL. Finally, as reported by ORNL, a new evaluation with a revised (renormalized) fission cross section is needed on 233 U. The challenge for this measurement lies in the difficulty of measuring the capture cross section data in the competing fission background, as the fission cross section is around one order of magnitude larger than the capture cross section for 233 U. The accuracy of a capture cross section measurement depends on discrimination between $\gamma$’s produced in capture and fission reactions, for which an experimental setup combining capture and fission detectors is needed. For the ($\eta$,$\gamma$) cross section measurement at LANSCE, this discrimination is achieved by combining the Detector for Advanced Neutron Capture Experiments (DANCE), to measure $\gamma$’s from capture reactions, with a Parallel Plate Avalanche Counter (PPAC) to tag the $\gamma$’s produced by fission. This method was successfully used to measure 235 U and 239 Pu capture cross sections. In these measurements, the neutron capture cross section was determined in a large fission background well above 100 keV. As part of the NCSP nuclear data effort, we have looked at past DANCE measurements on 233 U($\eta$,$\gamma$) and evaluated whether existing data is adequate to apply this technique.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterizing Shielded Special Nuclear Material by Neutron Capture Gamma-Ray Multiplicity Counting

We present a new neutron multiplicity counting analysis and measurement method for neutron-shielded fissile material using neutron-capture gamma rays. Neutrons absorbed in shielding produce characteristic gamma rays that preserve the otherwise lost neutron multiplicity signature. Neutron multiplicity counting provides estimates of fission parameters, such as neutron leakage multiplication, spontaneous fissioner (e.g. Pu-240) mass, and (α,n) ratio. Standard neutron multiplicity counting can incorporate the new neutron-capture gamma-ray multiplicity counting technique to characterize previously degenerate or intractable source configurations by maximizing the multiplicity signature. The new method decouples neutron source-detector interferences, such as reflection and thermalization time in the detector, that could improve measurements of the mean neutron lifetime. We also develop a detector prototype for the multiplicity counting of neutron-capture gamma rays and present detector design considerations, such as detection material and shielding, to optimize the detection of the 2.2 MeV hydrogen capture gamma ray. We simulate the prototype neutron- capture gamma-ray multiplicity counter against the BeRP ball in polyethylene shells to inform future measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification and Validation Tests of the Gamma Library of the ARC Software Package (Rev.1)

As part of the verification and validation (V&V) efforts of the Argonne Reactor Code (ARC) software system to support the Versatile Test Reactor (VTR) project of the U.S. Department of Energy (DOE), work has been performed to verify and validate the gamma (or photon) library of the multigroup cross section generation code MC 2 -3 of the ARC system, which is the essential part of the coupled neutron and gamma heating calculations to determine the heat generation rate or power distribution in the core. This V&V study was carried out in three steps: 1) review of the procedures and utility programs for generating the MC 2 -3 gamma library, 2) verification tests of cross sections and KERMA factors by comparing the total heat generation rate of coupled neutron and gamma calculation with that obtained with reaction Q values under the assumption of local gamma energy deposition and by comparing the prompt heat generation rate with that calculated with the MCNP6.2 code, and 3) validation tests of cross sections and KERMA factors by analyzing the ZPPR-15D gamma dose data measured with thermoluminescent dosimeters (TLD).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Creating a high energy alert system for the HAWC gamma ray observatory

One of the greatest mysteries in astrophysics is exactly how Cosmic Rays (CRs) are accelerated up to extremely high energies within our galaxy. The highest-energy galactic CRs are associated with gamma rays at ~100 TeV. Hadronic models of possible CR accelerators, including supernova remnants and pulsars, require the production of both gamma rays and neutrinos at these sources. Searching for coincidences between neutrino and the highest energy gamma ray observations can help confirm these theories. The High Altitude Water Cherenkov (HAWC) observatory is a ground based gamma ray observatory located in Puebla, Mexico. HAWC is able to detect gamma rays with energies greater than 100 TeV. It has a wide field of view and a 95% duty cycle, making it ideal for these types of coincidence searches. This work aims to create a high energy alert system for HAWC, sending out an alert to other experiments for high-energy gamma ray events it sees.

79 ASTRONOMY AND ASTROPHYSICS↗

Gamma and Neutron Measurement and Modeling of Irradiated TRISO Fuel

Given the unique characteristics of the PBR fuel cycle, both gamma and neutron measurements are expected to play important roles in performing and maintaining nuclear material control and accounting for spent pebbles to safeguard the fuel cycle. Given the lack of irradiated pebbles in the US, a variety of irradiated TRISO fuel samples with wide ranges of burnups and cooling times available at ORNL were used in this work. A large number of gamma and neutron measurements have been performed on these samples to collect data to test the various detectors and to benchmark the computer models to simulate the depletion and decay of the fuel and the measurements themselves. Two neutron detectors, including a custom-made detector and the Very High-Performance Neutron Multiplicity Counting, were used to measure the neutrons emitted by these TRISO samples. Three gamma spectrometry detectors, including an HPGe and the M400 CZT detector, were used to measure gamma-ray emissions from these samples. The M400 was recently adopted by the IAEA for fresh uranium measurements, but it was tested for spent fuel measurements prior to this project. Detailed MCNP models were developed to simulate these neutron and gamma measurements. Some GADRAS models were also developed to cross check the MCNP models for the gamma measurements. It was found challenging to perform neutron measurements in the hot cell due to the high background counts. Close agreements were observed between the simulated and measured neutron count rates in both detectors’ measurements of californium calibration sources. Both the HPGe and M400 detectors were able to measure the 604 and 662 keV peaks from these samples, which are the two most important peaks used to infer fuel burnup. Although the M400 detector did not have nearly good energy resolution and did not detect some of the minor peaks as the HPGe detector, it was found to be capable of handling significantly higher dose rates than HPGe. Given the complexities in the TRISO samples (e.g., different samples sizes) and uncertainties in the alignments between the detector and the TRISO fuel inside the containers, large scatters were found between the peak area rates and the samples’ burnups. However, the 604/662 peak ratios were found to trend well with the samples’ burnups among most samples in both measured and simulated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Search for Gravitational-wave Signals Associated with Gamma-Ray Bursts during the Second Observing Run of Advanced LIGO and Advanced Virgo

We present the results of targeted searches for gravitational-wave transients associated with gamma-ray bursts during the second observing run of Advanced LIGO and Advanced Virgo, which took place from 2016 November to 2017 August. We have analyzed 98 gamma-ray bursts using an unmodeled search method that searches for generic transient gravitational waves and 42 with a modeled search method that targets compact-binary mergers as progenitors of short gamma-ray bursts. Both methods clearly detect the previously reported binary merger signal GW170817, with p-values of <9.38 10 -6 (modeled) and 3.1 10 -4 (unmodeled). We do not find any significant evidence for gravitational-wave signals associated with the other gamma-ray bursts analyzed, and therefore we report lower bounds on the distance to each of these, assuming various source types and signal morphologies. Using our final modeled search results, short gamma-ray burst observations, and assuming binary neutron star progenitors, we place bounds on the rate of short gamma-ray bursts as a function of redshift for z ≤ 1. We estimate 0.07-1.80 joint detections with Fermi-GBM per year for the 2019-20 LIGO-Virgo observing run and 0.15-3.90 per year when current gravitational-wave detectors are operating at their design sensitivities.

79 ASTRONOMY AND ASTROPHYSICS↗

Evidence that Ultra-high-energy Gamma Rays Are a Universal Feature near Powerful Pulsars

The highest-energy known gamma-ray sources are all located within 0°5 of extremely powerful pulsars. This raises the question of whether ultra-high-energy (UHE; >56 TeV) gamma-ray emission is a universal feature expected near pulsars with a high spin-down power. Using four years of data from the High Altitude Water Cherenkov Gamma-Ray Observatory, we present a joint-likelihood analysis of 10 extremely powerful pulsars to search for subthreshold UHE gamma-ray emission correlated with these locations. We report a significant detection (>3σ), indicating that UHE gamma-ray emission is a generic feature of powerful pulsars. Finally, we discuss the emission mechanisms of the gamma rays and the implications of this result. The individual environment, such as the magnetic field and particle density in the surrounding area, appears to play a role in the amount of emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Molecular hydrogen in the galaxy and galactic gamma rays

Recent surveys of 2.6 mm CO emission and 100 MeV gamma-radiation in the galactic plane reveal a striking correlation suggesting that both emissions may be primarily proportional to the line-of-sight column density of H2 in the inner galaxy. Both the gamma ray and CO data suggest a prominent ring or arm consisting of cool clouds of H2 at a galactocentric distance of approximately 5 kpc with a mean density of approximately 4 atoms/cu cm. The importance of H2 in understanding galactic gamma ray observations is also reflected in the correlation of galactic latitude distribution of gamma rays and dense dust clouds. A detailed calculation of the gamma ray flux distribution in the 0 deg to 180 deg range using the CO data to obtain the average distribution of molecular clouds in the galaxy shows that most of the enhancement in the inner galaxy is due to pion-decay radiation and the 5 kpc ring plays a major role. Detailed agreement with the gamma ray data is obtained with the additional inclusion of contributions from bremsstrahlung and Compton radiation of secondary electrons and Compton radiation from the intense radiation field near the galactic center.

Stecker, F. W.↗

Significance of medium energy gamma ray astronomy in the study of cosmic rays

Medium energy (about 10 to 30 MeV) gamma ray astronomy provides information on the product of the galactic electron cosmic ray intensity and the galactic matter to which the electrons are dynamically coupled by the magnetic field. Because high energy (greater than 100 MeV) gamma ray astronomy provides analogous information for the nucleonic cosmic rays and the relevant matter, a comparison between high energy and medium energy gamma ray intensities provides a direct ratio of the cosmic ray electrons and nucleons throughout the galaxy. A calculation of gamma ray production by electron bremsstrahlung shows that: bremsstrahlung energy loss is probably not negligible over the lifetime of the electrons in the galaxy; and the approximate bremsstrahlung calculation often used previously overestimates the gamma ray intensity by about a factor of two. As a specific example, expected medium energy gamma ray intensities are calculated for the speral arm model.

Fichtel, C. E.↗

SAS-2 gamma-ray observations of PSR 1747-46

Observations with the SAS-2 high energy ( 35 MeV) gamma-ray telescope show evidence of gamma-ray emission from the radio pulsar PSR 1747-46. When the arrival times of gamma-rays from the region of the pulsar were converted to pulsar phases using the radio period and period derivative, a single peak was found in the phase plot, with a Poisson probability of occurring by chance of .00008. Independently, the time-averaged data for the PSR 1747-46 region show an enhancement over the surrounding region of the sky at the same galactic latitude, with a Poisson probability of chance occurrence of less than .008. The probability that these results are chance is the product of these two probabilities times the number of radio pulsars examined (73). This overall probability is sufficiently small (.00005) to suggest an identification of a new gamma-ray pulsar. In the gamma-ray pulsar plot, the peak falls 0.16 + or - 0.03 period after the radio pulsar peak. This phase shift is, within uncertainties, the same as that observed between the single radio peak and the first of the two gamma-ray peaks seen in the phase plot for PSR-0833-45 (the Vela pulsar).

Thompson, D. J.↗