Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Functionally Graded”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Production and Performance of the InFOCmicronS 20-40 keV Graded Multilayer Mirror

The International Focusing Optics Collaboration for micron Crab Sensitivity (InFOC micronS) balloon-borne hard x-ray incorporates graded multilayer technology to obtain significant effective area at energies previously inaccessible to x-ray optics. The telescope mirror consists of 2040 segmented thin aluminum foils coated with replicated Pt/C multilayers. A sample of these foils was scanned using a pencil-beam reflectometer to determine, multilayer quality. The results of the reflectometer measurements demonstrate our capability to produce large quantity of foils while maintaining high-quality multilayers with a mean Nevot-Croce interface roughness of 0.5nm. We characterize the performance of the complete InFOC micronS telescope with a pencil beam raster scan to determine the effective area and encircled energy function of the telescope. The effective area of the complete telescope is 78, 42 and 22 square centimeters at 20 30 and 40 keV. respectively. The measured encircled energy fraction of the mirror has a half-power diameter of 2.0 plus or minus 0.5 arcmin (90% confidence). The mirror successfully obtained an image of the accreting black hole Cygnus X-1 during a balloon flight in July, 2001. The successful completion and flight test of this telescope demonstrates that graded-multilayer telescopes can be manufactured with high reliability for future x-ray telescope missions such as Constellation-X.

Berendse, F.↗

Knife mill operating factors effect on switchgrass particle size distributions

Biomass particle size impacts handling, storage, conversion, and dust control systems. Switchgrass (Panicum virgatum L.) particle size distributions created by a knife mill were determined for integral classifying screen sizes from 12.7 to 50.8 mm, operating speeds from 250 to 500 rpm, and mass input rates from 2 to 11 kg/min. Particle distributions were classified with standardized sieves for forage analysis that included horizontal sieving motion with machined-aluminum sieves of thickness proportional to sieve opening dimensions. Then, a wide range of analytical descriptors were examined to mathematically represent the range of particle sizes in the distributions. Correlation coefficient of geometric mean length with knife mill screen size, feed rate, and speed were 0.872, 0.349, and 0.037, respectively. Hence, knife mill screen size largely determined particle size of switchgrass chop. Feed rate had an unexpected influence on particle size, though to a lesser degree than screen size. The Rosin Rammler function fit the chopped switchgrass size distribution data with an R2 > 0.982. Mass relative span was greater than 1, which indicated a wide distribution of particle sizes. Uniformity coefficient was more than 4.0, which indicated a large assortment of particles and also represented a well-graded particle size distribution. Knife mill chopping of switchgrass produced strongly fine skewed mesokurtic particles with 12.7 25.4 mm screens and fine skewed mesokurtic particles with 50.8 mm screen. Results of this extensive analysis of particle sizes can be applied to selection of knife mill operating parameters to produce a particular size of switchgrass chop, and will serve as a guide for relations among the various analytic descriptors of biomass particle distributions.

09 BIOMASS FUELS↗

N08C9 (Alliance): A Phase 3 Randomized Study of Sulfasalazine Versus Placebo in the Prevention of Acute Diarrhea in Patients Receiving Pelvic Radiation Therapy

Purpose: To provide confirmatory evidence on the use of sulfasalazine to reduce enteritis during pelvic radiation therapy (RT), following 2 prior single-institution trials suggestive that benefit existed. Methods and Materials: A multi-institution, randomized, double-blind, placebo-controlled phase 3 trial was designed to assess the efficacy of sulfasalazine versus placebo in the treatment of RT-related enteritis during RT including the posterior pelvis (45.0-53.5 Gy) and conducted through a multicenter national cooperative research alliance. Patients received 1000 mg of sulfasalazine or placebo orally twice daily during and for 4 weeks after RT. The primary endpoint was maximum severity of diarrhea (Common Terminology Criteria for Adverse Events version 4.0). Toxicity and bowel function were assessed by providers through a self-administered bowel function questionnaire taken weekly during RT and for 6 weeks afterward. Results: Eighty-seven patients were enrolled in the trial between April 29, 2011, and May 13, 2013, with evenly distributed baseline factors. At the time of a planned interim toxicity analysis, more patients with grade ≥3 diarrhea received sulfasalazine than received placebo (29% vs 11%, P=.04). A futility analysis showed that trial continuation would be unlikely to yield a positive result, and a research board recommended halting study treatment. Final analysis of the primary endpoint showed no significant difference in maximum diarrhea severity between the sulfasalazine and placebo arms (P=.41). Conclusions: Sulfasalazine does not reduce enteritis during pelvic RT and may be associated with a higher risk of adverse events than placebo. This trial illustrates the importance of confirmatory phase 3 trials in the evaluation of symptom-control agents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of a commercial hybrid iterative and model-based reconstruction algorithm in radiation oncology

Purpose: Iterative reconstruction (IR) reduces noise, thereby allowing dose reduction in computed tomography (CT) while maintaining comparable image quality to filtered back-projection (FBP). This study sought to characterize image quality metrics, delineation, dosimetric assessment, and other aspects necessary to integrate IR into treatment planning. Methods: CT images (Brilliance Big Bore v3.6, Philips Healthcare) were acquired of several phantoms using 120 kVp and 25–800 mAs. IR was applied at levels corresponding to noise reduction of 0.89–0.55 with respect to FBP. Noise power spectrum (NPS) analysis was used to characterize noise magnitude and texture. CT to electron density (CT-ED) curves were generated over all IR levels. Uniformity as well as spatial and low contrast resolution were quantified using a CATPHAN phantom. Task specific modulation transfer functions (MTF{sub task}) were developed to characterize spatial frequency across objects of varied contrast. A prospective dose reduction study was conducted for 14 patients undergoing interfraction CT scans for high-dose rate brachytherapy. Three physicians performed image quality assessment using a six-point grading scale between the normal-dose FBP (reference), low-dose FBP, and low-dose IR scans for the following metrics: image noise, detectability of the vaginal cuff/bladder interface, spatial resolution, texture, segmentation confidence, and overall image quality. Contouring differences between FBP and IR were quantified for the bladder and rectum via overlap indices (OI) and Dice similarity coefficients (DSC). Line profile and region of interest analyses quantified noise and boundary changes. For two subjects, the impact of IR on external beam dose calculation was assessed via gamma analysis and changes in digitally reconstructed radiographs (DRRs) were quantified. Results: NPS showed large reduction in noise magnitude (50%), and a slight spatial frequency shift (∼0.1 mm{sup −1}) with application of IR at L6. No appreciable changes were observed for CT-ED curves between FBP and IR levels [maximum difference ∼13 HU for bone (∼1% difference)]. For uniformity, differences were ∼1 HU between FBP and IR. Spatial resolution was well conserved; the largest MTF{sub task} decrease between FBP and IR levels was 0.08 A.U. No notable changes in low-contrast detectability were observed and CNR increased substantially with IR. For the patient study, qualitative image grading showed low-dose IR was equivalent to or slightly worse than normal dose FBP, and is superior to low-dose FBP (p < 0.001 for noise), although these did not translate to differences in CT number, contouring ability, or dose calculation. The largest CT number discrepancy from FBP occurred at a bone/tissue interface using the most aggressive IR level [−1.2 ± 4.9 HU (range: −17.6–12.5 HU)]. No clinically significant contour differences were found between IR and FBP, with OIs and DSCs ranging from 0.85 to 0.95. Negligible changes in dose calculation were observed. DRRs preserved anatomical detail with <2% difference in intensity from FBP combined with aggressive IRL6. Conclusions: These results support integrating IR into treatment planning. While slight degradation in edges and shift in texture were observed in phantom, patient results show qualitative image grading, contouring ability, and dosimetric parameters were not adversely affected.

60 APPLIED LIFE SCIENCES↗

Equipping an FPGA-Based Mars Rover With an LN-200 IMU

The Mars Exploration Rovers (MER) currently navigating the surface of Mars are outfitted with an advanced stereovision correlation algorithm which allows them to "see" three-dimensionally and autonomously avoid obstac'les in their path. A bottleneck of this system is that it is computationally intense and requires 3 minutes of processing for every correlated image and path choice. Taking advantage of the optimization and reprogrammability of FPGAs, the Mobility Avionics lab has reduced this process to under a second. The lab is demonstrating the advancement with a prototype rover, complete with an LN-200 inertial measurement unit (IMU), which is a flight spare from MER. The LN-200 is a space-grade, six degrees-of-freedom IMU using three fiber-optic gyroscopes and three silicon accelerometers and no moving parts. It has particular power-sequencing needs and communicates with a specialized serial protocol (SDLC over RS-422), requiring specific hardware and software for proper functionality and interfacing with an FPGA. The process of incorporating the LN-200 into the system is described herein.

Zola, Nicholas J.↗

Complement 5a stimulates macrophage polarization and contributes to tumor metastases of colon cancer

Highlights: • The mechanisms regulating the TAM M2 phenotype in tumor metastases remain unclear. • C5a regulates the M2 phenotype of TAMs in tumor metastases through NF-κB signaling. • C5aR may be a novel marker for cancer prognosis and drugs targeting for management. Inflammatory cells such as macrophages can play a pro-tumorigenic role in the tumor stroma. Tumor-associated macrophages (TAMs) generally display an M2 phenotype with tumor-promoting activity; however, the mechanisms regulating the TAM phenotype remain unclear. Complement 5a (C5a) is a cytokine-like polypeptide that is generated during complement system activation and is known to promote tumor growth. Herein, we investigated the role of C5a on macrophage polarization in colon cancer metastasis in mice. We found that deficiency of the C5a receptor (C5aR) severely impairs the metastatic ability of implanted colon cancer cells. C5aR was expressed on TAMs, which exhibited an M2-like functional profile in colon cancer liver metastatic lesions. Furthermore, C5a mediated macrophage polarization and this process relied substantially on activation of the nuclear factor-kappa B (NF-κB) pathway. Finally, analysis of human colon carcinoma indicated that C5aR expression is negatively associated with tumor differentiation grade. Our results demonstrate that C5aR has a central role in regulating the M2 phenotype of TAMs, which in turn, contributes to hepatic metastasis of colon cancer through NF-κB signaling. C5a is a potential novel marker for cancer prognosis and drugs targeting complement system activation, specifically the C5aR pathway, may offer new therapeutic opportunities for colon cancer management.

60 APPLIED LIFE SCIENCES↗

PEDOT:PSS/GO nanocomposites: Determination of the aspect ratio by indirect measurements

Polymer nanocomposites properties significantly depend on the average size of the fillers dispersed into the matrix and on the grade of the dispersion, the latter influenced by the process techniques. In this work, we determined the aspect ratio of graphene oxide (GO) dispersed into Poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS), starting from the indirect measurement of the rheological behavior of polymer/filler mixtures, as a function of the shear rate and the volumetric composition. PEDOT:PSS+GO nanocomposite films were also realized by spin coating on different substrates and characterized by Scanning electron microscopy (SEM) and X-ray diffraction (XRD), in order to analyze the quality of the dispersion, even by direct measurements.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Experimental analysis of conductive drying of paper and board

The primary heat transfer source in the conventional multi-cylinder drying of paper and board is conduction. Conduction is facilitated by high-tension contact with steam-heated cylinders, while convective drying, the main mass transfer source, operates as heated air flows over the paper web in the pockets. This conduction process occurs at elevated temperatures and contact pressures to ensure effective contact between the wet paper web and the heated cylinders. The contact pressures and temperatures of the hot surface significantly influence the conductive drying characteristics. This research paper presents an experimental study that involves designing a simple lab-scale setup with in-situ and continuous sensing capabilities for various commercially available grades of paper and board. Embedded thermocouples measure the temperatures of the heated platen and the sheet, allowing the collection of flux data to determine heat transfer characteristics. Here, the goal of this study is to ascertain the instantaneous contact coefficients for different basis weights as a function of moisture content. The acquired data will provide valuable insights and information towards process development, design and simulation of the paper drying process.

42 ENGINEERING↗

MELCOR Accident Progression and Source Term Demonstration Calculations for a Heat Pipe Reactor

MELCOR is an integrated thermal hydraulics, accident progression, and source term code for reactor safety analysis that has been developed at Sandia National Laboratories for the United States Nuclear Regulatory Commission (NRC) since the early 1980s. Though MELCOR originated as a light water reactor (LWR) code, development and modernization efforts have expanded its application scope to includ e non-LWR reactor concepts. Current MELCOR development efforts include providing the NRC with the analytical capabilities to support regulatory readiness for licensing non-LWR techno logies under Strategy 2 of the NRC?s near- term Implementation Action Plans. Beginning with the Next Generation Nuclear Project (NGNP), MELCOR has undergone a range of enha ncements to provide analytical capabilities for modeling the spectrum of advanced non-LWR concepts. This report describes the generic plant model developed to demonstrate MELCOR capabilities to perform heat pipe reactor (HPR) safety evaluations. The generic plant mode l is based on a publicly-available Los Alamos National Laboratory (LANL) Megapower design as modified in the Idaho National Laboratory (INL) Design A description. For plant aspects (e.g., reactor building size and leak rate) that are not described in the LANL and INL references , the analysts made assumptions needed to construct a MELCOR full-plant model. The HP R uses high assay, low-enrichment uranium (HALEU) fuel with steel cladding that uses heat pipes to transfer heat to a secondary Brayton air cycle. The core region is surrounded by a stainless-steel shroud, alumina reflector, core barrel and boron carbide neutron shield. The reactor is secured inside a below-grade cavity, with the operating floor located above the cavity. Example calculations are performed to show the plant response and MELCOR capabilities to characterize a range of accident conditions. The accidents selected for evaluation consider a range of degraded and failed modes of operation for key safety functions providing re activity control, the primary and secondary system heat removal, and the effectiveness of th e confinement natural circulation flow into the reactor cavity (i.e., a flow blockage).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of graded distribution of scattering centers on ballistic transport

The transmission coefficient of a two dimensional scattering region connected to ideal leads was calculated for the case of electrons interacting with an inhomogeneous distribution of repulsive or attractive scattering centers. The scattering centers with Gaussian profiles were positioned at regular intervals perpendicular to the transport direction, but were spaced according to a power law along this direction. The transmission function was obtained using a scattering formalism based on the R-matrix method. The simulations revealed that although, overall, the transmission coefficient decreases and becomes almost monotonously dependent on energy as the inhomogeneity of both attractive and repulsive scattering centers increases, the redistribution of transmission between open channels depends on the type of scattering centers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effectiveness and Morbidity Associated With Reirradiation in Conservative Salvage Management of Recurrent Soft-Tissue Sarcoma

Purpose: The management of isolated local recurrence of soft-tissue sarcoma is therapeutically complex, and functional conservative management is preferable to radical or amputative salvage surgery. This study reviews University of Florida experience using conservative resection and reirradiation to manage isolated local recurrences of soft-tissue sarcoma. Methods and Materials: Between 1976 and 2005, a total of 14 patients who underwent primary conservative resection and irradiation developed isolated local recurrence and were managed with salvage conservative resection and reirradiation. Of the patients treated, 3 had tumors of the distal extremity, 8 had tumors of the proximal extremity, and 3 had tumors of the trunk. At the time of recurrence, 64% of tumors were greater than 5 cm and 79% were high grade. In combination with gross total resection, 13 of 14 patients received external beam radiotherapy with or without brachytherapy, and 1 patient was treated with brachytherapy alone. Two patients received chemotherapy. Results: The median follow-up was 30 months, and no living patients were lost during follow-up. From retreatment, the 5-year actuarial overall survival, cause-specific survival, and local control rates were 40%, 40%, and 18% respectively. There was a 50% incidence of serious complication requiring either reoperation or leading to permanent functional impairment. Of the 14 patients, only 1 has remained disease free and without significant complications. No treatment factors, including achieving wide surgical margins or delivering higher radiation dosages, seemed to confer an advantage in local control. Conclusions: Salvage therapy for management of locally recurrent soft-tissue sarcoma is challenging, and the effects of reoperation and reirradiation can be severe.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of minority-carrier diffusion lengths using wedge-shaped semiconductor photoelectrodes

Measurement of the photocurrent as a function of the thickness of a light absorber has been shown herein both theoretically and experimentally to provide a method for determination of the minority-carrier diffusion length of a sample. To perform the measurement, an illuminated spot of photons with an energy well above the band gap of the material was scanned along the thickness gradient of a wedge-shaped, rear-illuminated semiconducting light absorber. Photogenerated majority carriers were collected through a back-side transparent ohmic contact, and a front-side liquid or Schottky junction collected the photogenerated minority carriers. Calculations showed that the diffusion length could be evaluated from the exponential variation in photocurrent as a function of the thickness of the sample. Good agreement was observed between experiment and theory for a solid-state silicon Schottky junction measured using this method. As an example for the application of the technique to semiconductor/liquid-junction photoelectrodes, the minority-carrier diffusion length was determined for graded thickness, sputtered tungsten trioxide and polished bismuth vanadate films under back-illumination in contact with an aqueous electrolyte. Furthermore, this wedge technique does not require knowledge of the spectral absorption coefficient, doping, or surface recombination velocity of the sample.

42 ENGINEERING↗

Lunar base heat pump, phase 1

This report describes the Phase 1 process and analysis used to select a refrigerant and thermodynamic cycle as the basis of a vapor compression heat pump requiring a high temperature lift, then to perform a preliminary design to implement the selected concept, including major component selection. Use of a vapor compression heat pump versus other types was based on prior work performed for the Electric Power Research Institute. A high lift heat pump is needed to enable a thermal control system to remove heat down to 275 K from a habitable volume when the external thermal environment is severe. For example, a long-term lunar base habitat will reject heat from a space radiator to a 325 K environment. The first step in the selection process was to perform an optimization trade study, quantifying the effect of radiator operating temperature and heat pump efficiency on total system mass; then, select the radiator operating temperature corresponding to the lowest system mass. Total system mass included radiators, all heat pump components, and the power supply system. The study showed that lunar night operation, with no temperature lift, dictated the radiator size. To operate otherwise would require a high mass penalty to store power. With the defined radiation surface, and heat pump performances assumed to be from 40 percent to 60 percent of the Carnot ideal, the optimum heat rejection temperature ranged from 387 K to 377 K, as a function of heat pump performance. Refrigerant and thermodynamic cycles were then selected to best meet the previously determined design conditions. The system was then adapted as a ground-based prototype lifting temperature to 360 K (versus 385 K for flight unit) and using readily available commercial-grade components. Over 40 refrigerants, separated into wet and dry compression behavioral types, were considered in the selection process. Refrigerants were initially screened for acceptable critical temperature. The acceptable refrigerants were analyzed in ideal single and two-stage thermodynamic cycles. Top candidates were analyzed assuming realistic component limits and system pressure drops, and were evaluated for other considerations such as safety, environmental impact, and commercial availability. A maximum coefficient of performance (COP) of 56 percent of the Carnot ideal was achievable for a three-stage CFC-11 cycle operating under the flight conditions above. The program was completed by defining a control scheme and by researching and selecting the major components, compressor and heat exchangers, that could be used to implement the thermodynamic cycle selected. Special attention was paid to using similar technologies for the SIRF and flight heat pumps resulting in the commercially available equivalent of the flight unit. A package concept was generated for the components selected and mass and volume estimated.

Goldman, Jeffrey H.↗

C-Sphere Strength-Size Scaling in a Bearing-Grade Silicon Nitride

A C-sphere specimen geometry was used to determine the failure strength distributions of a commercially available bearing-grade silicon nitride (Si3N4) having ball diameters of 12.7 and 25.4 mm. Strengths for both diameters were determined using the combination of failure load, C sphere geometry, and finite element analysis and fitted using two-parameter Weibull distributions. Effective areas of both diameters were estimated as a function of Weibull modulus and used to explore whether the strength distributions predictably strength-scaled between each size. They did not. That statistical observation suggested that the same flaw type did not limit the strength of both ball diameters indicating a lack of material homogeneity between the two sizes. Optical fractography confirmed that. It showed there were two distinct strength-limiting flaw types in both ball diameters, that one flaw type was always associated with lower strength specimens, and that significantly higher fraction of the 24.5-mm-diameter c-sphere specimens failed from it. Predictable strength-size-scaling would therefore not result as a consequence of this because these flaw types were not homogenously distributed and sampled in both c-sphere geometries.

36 MATERIALS SCIENCE↗

Software Development: 3D Animations and Creating User Interfaces for Realistic Simulations

My fall 2015 semester was spent at the Lyndon B. Johnson Space Center working in the Integrated Graphics, Operations, and Analysis Laboratory (IGOAL). My first project was to create a video animation that could tell the story of OMICS. OMICS is a term being used in the field of biomedical science to describe the collective technologies that study biological systems, such as what makes up a cell and how it functions with other systems. In the IGOAL I used a large 23 inch Wacom monitor to draw storyboards, graphics, and line art animations. I used Blender as the 3D environment to sculpt, shape, cut or modify the several scenes and models for the video. A challenge creating this video was to take a term used in biomedical science and describe it in such a way that an 8th grade student can understand. I used a line art style because it would visually set the tone for what we thought was an educational style. In order to get a handle on the perspective and overall feel for the animation without overloading my workspace, I split up the 2 minute animation into several scenes. I used Blender's python scripting capabilities which allowed for the addition of plugins to add or modify tools. The scripts can also directly interact with the objects to create naturalistic patterns or movements. After collecting the rendered scenes, I used Blender's built-in video editing workspace to output the animation. My second project was to write software that emulates a physical system's interface. The interface was to simulate a boat, ROV, and winch system. Simulations are a time and cost effective way to test complicated data and provide training for operators without having to use expensive hardware. We created the virtual controls with 3-D Blender models and 2-D graphics, and then add functionality in C# using the Unity game engine. The Unity engine provides several essential behaviors of a simulator, such as the start and update functions. A framework for Unity, which was developed in the lab, provided a way to place the different widgets on the virtual console dock and have them resize correctly based on the window dimensions.. My task in this project was to create the controls and visualizations for the data coming in from the simulator for the boat portion of the project. I wrote a class for each control window to handle the functionality of that widget. I implemented 11 widgets that make up the ship portion of the simulator. The members of the lab were each masters of their craft and I'm glad I had the opportunity to learn from them. I learned to plan strategically so I could finish this project on time. I allotted time for storyboarding, development, and refinement. In regards to animating I learned to use modifiers like lattice, boolean and build deformers. I also learned how to animate with drivers, how to use the dope sheet, and how to use the graph editor. In coding I learned to limit the chances for bugs by privatizing functions that should be exclusive to their class. I learned how to use the GIT repository to commit, stash and pull the latest build. I learned a bit of everything because I had the chance to see the entire application development process from the artwork, to the implementation.

Gordillo, Orlando Enrique↗

The effect of pore structure in ethane-selective metal-organic frameworks for ethylene purification

Separation of ethylene from ethane is of great importance in petrochemical industry. Adsorptive separation making use of porous materials such as metal-organic frameworks (MOFs) is an energy efficient technology compared to the conventional cryogenic distillation. However, preferential adsorption of ethylene over ethane represents the major current challenge. Here we demonstrate how pore structure can significantly alter the adsorption selectivity in two isoreticular Zr-MOFs. A simple ligand functionalization in UiO-66 yields smaller/better matching pore for ethane, and weaker interaction with ethylene, greatly enhancing ethane/ethylene selectivity in MOF-801. Ab initio calculations combined with in situ infrared spectroscopic analysis unveil the nature of host-guest interactions and differences in the overall binding energies. Polymer-grade ethylene (99.9%) can be produced directly from ethane/ethylene mixture in a single step. Having well-balanced adsorption capacity and selectivity, low-cost synthesis and easy scalability MOF-801 stands out as a promising ethane-selective adsorbent for one-step ethylene purification under ambient conditions.

36 MATERIALS SCIENCE↗