Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Hydrodynamic and Longitudinal Impedance Analysis of Cerebrospinal Fluid Dynamics at the Craniovertebral Junction in Type I Chiari Malformation

Elevated or reduced velocity of cerebrospinal fluid (CSF) at the craniovertebral junction (CVJ) has been associated with type I Chiari malformation (CMI). Thus, quantification of hydrodynamic parameters that describe the CSF dynamics could help assess disease severity and surgical outcome. In this study, we describe the methodology to quantify CSF hydrodynamic parameters near the CVJ and upper cervical spine utilizing subject-specific computational fluid dynamics (CFD) simulations based on in vivo MRI measurements of flow and geometry. Hydrodynamic parameters were computed for a healthy subject and two CMI patients both pre- and post-decompression surgery to determine the differences between cases. For the first time, we present the methods to quantify longitudinal impedance (LI) to CSF motion, a subject-specific hydrodynamic parameter that may have value to help quantify the CSF flow blockage severity in CMI. In addition, the following hydrodynamic parameters were quantified for each case: maximum velocity in systole and diastole, Reynolds and Womersley number, and peak pressure drop during the CSF cardiac flow cycle. The following geometric parameters were quantified: cross-sectional area and hydraulic diameter of the spinal subarachnoid space (SAS). The mean values of the geometric parameters increased post-surgically for the CMI models, but remained smaller than the healthy volunteer. All hydrodynamic parameters, except pressure drop, decreased post-surgically for the CMI patients, but remained greater than in the healthy case. Peak pressure drop alterations were mixed. To our knowledge this study represents the first subject specific CFD simulation of CMI decompression surgery and quantification of LI in the CSF space. Further study in a larger patient and control group is needed to determine if the presented geometric and/or hydrodynamic parameters are helpful for surgical planning.

59 BASIC BIOLOGICAL SCIENCES↗

Poroelastic measurement schemes resulting in complete data sets for granular and other anisotropic porous media

Poroelastic analysis usually progresses from assumed knowledge of dry or drained porous media to the predicted behavior of fluid-saturated and undrained porous media. Unfortunately, the experimental situation is often incompatible with these assumptions, especially when field data (from hydrological or oil/gas reservoirs) are involved. The present work considers several different experimental scenarios typified by one in which a set of undrained poroelastic (stiffness) constants has been measured using either ultrasound or seismic wave analysis, while some or all of the dry or drained constants are normally unknown. Drained constants for such a poroelastic system can be deduced for isotropic systems from available data if a complete set of undrained compliance data for the principal stresses are available - together with a few other commonly measured quantities such as porosity, fluid bulk modulus, and grain bulk modulus. Similar results are also developed here for anisotropic systems having up to orthotropic symmetry if the system is granular (i.e., composed of solid grains assembled into a solid matrix, either by a cementation process or by applied stress) and the grains are known to be elastically homogeneous. Finally, the analysis is also fully developed for anisotropic systems with nonhomogeneous (more than one mineral type), but still isotropic, grains - as well as for uniform collections of anisotropic grains as long as their axes of symmetry are either perfectly aligned or perfectly random.

54 ENVIRONMENTAL SCIENCES↗

Power balance and wall erosion measurements in a helicon plasma

The power balance measurements in a 1 kW argon helicon plasma discharge are demonstrated. The quantitative wall heat flux measurements using nonintrusive infrared imaging of the glass tube surface, along with data from bolometric probes and calibrated photodiodes to measure heat flux from the rest of the plasma, are shown. For the cylindrical discharge, with radius much less than the axial length, approximately 15% of 1 kW input power is lost in the transmission lines and matching network, 54% is lost through radial particle transport to the walls, 16% is lost through radiation, and 8% is lost through ion impact in the vicinity of the antenna. Wall erosion of the confining glass tube occurs due to sputter etching by ions accelerated in the electrostatic fields produced by the antenna. Wall etch rate measurements are used to quantify particle fluxes to the wall, which are in rough agreement with particle fluxes calculated from thermal flux.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Autonomous sensor suite for evaluating fish-turbine interactions and environmental impacts in marine renewable energy and hydropower

Marine renewable energy (MRE) harnesses ocean-based resources such as waves, tides, currents, and thermal or salinity gradients for sustainable power generation. It has the potential to complement existing renewable resources, support remote communities, and contribute to decarbonization efforts. However, understanding the hydrodynamic forces created by MRE devices and their impacts on marine life is critical for responsible deployment. Here, to address these concerns, advanced sensor devices, including the Marine Sensor Fish (MSF), Sensor Fish Mini (SF Mini), and Flexible Sensor Fish (FSF), were developed to measure interactions between aquatic organisms and MRE systems. This paper details the design, manufacturing, calibration, and field deployment of these sensor suites, highlighting their ability to capture key physical stressors such as shear forces, pressure changes, and collision impacts. The MSF successfully evaluated turbine interactions at a tidal turbine in the Salish Sea, capturing data on turbulence, collision impact, and pressure gradients. The SF Mini validated hydrodynamic conditions in scaled hydraulic models, supporting computational fluid dynamics simulations. The FSF, with its flexible silicone body, measured species-specific impacts in turbulent environments. This research demonstrates the potential of Sensor Fish technology to advance sustainable marine energy systems by reducing biological impacts and informing environmentally sustainable designs.

Ecological impacts↗

Photoacoustically Measured Speeds of Sound of Liquid HBO2: On Unlocking the Fuel Potential of Boron

Elucidation of geodynamic, geochemical, and shock induced processes is often limited by challenges to accurately determine molecular fluid equations of state (EOS). High pressure liquid state reactions of carbon species underlie physiochemical mechanisms such as differentiation of planetary interiors, deep carbon sequestration, propellant deflagration, and shock chemistry. Here we introduce a versatile photoacoustic technique developed to measure accurate and precise speeds of sound (SoS) of high pressure molecular fluids and fluid mixtures. SoS of an intermediate boron oxide, HBO{sub 2} are measured up to 0.5 GPa along the 277 C isotherm. A polarized Exponential-6 interatomic potential form, parameterized using our SoS data, enables EOS determinations and corresponding semi-empirical evaluations of > 2000 C thermodynamic states including energy release from bororganic formulations. Our thermochemical model propitiously predicts boronated hydrocarbon shock Hugoniot results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MICRO- AND NANOSCALE MEASUREMENT METHODS FOR PHASE CHANGE HEAT TRANSFER ON PLANAR AND STRUCTURED SURFACES

In this opinion piece, we discuss recent advances in experimental methods for characterizing phase change heat transfer. We begin with a survey of techniques for high-resolution measurements of temperature and heat flux at the solid surface and in the working fluid. Next, we focus on diagnostic tools for boiling heat transfer and describe techniques for visualizing the temperature and velocity fields, as well as measurements at the single bubble level. Finally, we discuss techniques to probe the kinetics of vapor formation within a few molecular layers of the interface. We conclude with our outlook for future progress in experimental methods for phase change heat transfer.

Buongiorno, J↗

Coaxial probe for nuclear magnetic resonance diffusion and relaxation correlation experiments

A coaxial nuclear magnetic resonance (NMR) probe is built to measure diffusion and relaxation properties of liquid samples. In particular, we demonstrate the acquisition of two-dimensional (2D) distribution functions (T{sub 1}-T{sub 2} and diffusion–T{sub 2}), essential for fluids characterization. The compact design holds promise for miniaturization, thus enabling the measurement of molecular diffusion that is inaccessible to conventional micro-NMR setups. Potential applications range from crude oil characterization to biomolecular screening and detections.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of Brayton Cycles Utilizing Supercritical Carbon Dioxide

This white paper documents a detailed and extensive Brayton cycle analysis that was performed to better understand at a fundamental level the dependence of the Brayton cycle performance on operating conditions, working fluid, supercritical fluid properties, and some cycle non-idealities. This work was performed to better understand the factors controlling Brayton cycle performance and optimal operating conditions, particularly for cycles utilizing supercritical CO 2 (sCO 2 ) as the working fluid. The focus of this study is on cycle performance, particularly efficiency. No cost estimates were performed. However, as a single indirect measure of cycle cost, some sensitivity analyses on specific power (net output divided by working fluid mass flow rate) were included.

42 ENGINEERING↗

ARM Aerial Facility (AAF) - Unmanned Aircraft Systems, Fine Condensation Particle Counter via CVI Inlet, Quality Controlled

The Fine Condensation Particle Counter (or CPCF) measures sub-micron aerosol particle number concentration by condensing fluid onto particles and causing them to grow to sizes that are easily detectable by optical scattering. Counts particles with sizes that range from 10 to 3000 nanometers. Quality controlled and merged with AAF Nav data.

54 ENVIRONMENTAL SCIENCES↗

One-dimensional temperature measurement of supersonic jet flow by resonantly ionized photoemission thermometry of molecular nitrogen

As the field of fluid dynamics progresses, the demand for sophisticated diagnostic methods to accurately assess flow conditions rises. In this work, resonantly ionized photoemission thermometry (RIPT) has been used to directly target and ionize diatomic nitrogen (N 2 ) to measure one-dimensional (1D) temperature profiles in a supersonic jet flow. This technique can be considered non-intrusive as the premise uses resonantly enhanced multiphoton ionization (REMPI) to target molecular nitrogen. This resonance excites N 2 into absorption bands of the P, Q, and R rotational branches of N 2 ( b 1 Π u ). The ideal (3 + 1) REMPI scheme excites from the ground state and ionizes N 2 ( b 1 Π u ← X 1 Σ g + ) where de-excitation results in photoemission from the first negative band of ionized N 2 + ( B 2 Σ u + → X 2 Σ g + ) as nitrogen returns to the ground state. The resulting emission can be observed using an intensified camera, thus permitting inference of the rotational temperature of ground-state molecular nitrogen. A linearly regressive Boltzmann distribution is applied based on previous calibration data for this technique to quantify the temperature along the ionized line. This work applies this technique to a pure N 2 supersonic jet in cross-flow and counter-flow orientations to demonstrate N 2 RIPT’s applications in a supersonic flow. Temperature variations are observed at different locations downstream of the exit in cross-flow, and axisymmetric in counter-flow, to generate profiles characterizing the flow dynamics. Due to the collisional effects resulting from the number density of N 2 at higher pressures, a (3 + 2) REMPI scheme is observed throughout this text.

Clark, Aleksander (ORCID:0009000855600042)↗

TWO-TEMPERATURE MODELS FOR POLAR PLUMES: COOLING BY MEANS OF STRONG BASE HEATING

In earlier one-fluid hydrodynamical calculations incorporating heat conduction and radiative losses, it was shown that the high densities in polar plumes could be reproduced by including a concentrated heat source near the plume base, in addition to the global heating required in both the plume and interplume regions of the coronal hole. The extra heating (attributed to interchange reconnection between the open flux and an underlying magnetic bipole) results in lower flow speeds and temperatures relative to the interplume gas, predictions that have since been confirmed by spectroscopic measurements. Here, the model is extended to the two-fluid case, in which ions and electrons are allowed to have different temperatures, coupling is via Coulomb collisions, and heat transport is mainly by electrons. Again, we find that depositing energy very close to the coronal base, in either the protons or electrons (or both), raises the densities and decreases the flow speeds everywhere along the flux tube. The higher densities in turn act to lower the ion temperatures by coupling the protons more closely to the energy-losing electrons. In addition, we find that energy must be deposited globally in both the electrons and the ions; without this direct heating, the electrons would end up cooler in the interplume region than in the plume, contrary to observations. Increasing the rate of flux-tube expansion has the effect of lowering the electron and ion temperatures and reducing the asymptotic flow speed, both in the plume and the interplume region; the observed densities and temperatures can be matched by taking the magnetic field to fall off with radius roughly as r{sup -4}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New experimental correlations to characterize compressible flow losses at 90-degree T-junctions

New experimental correlations to characterize energy losses in adiabatic compressible flow at 90-degree T-junctions and their expanded uncertainties are presented. These new correlations are based on a new linking between branches coefficient definition, K, and show a logarithmic relationship with mass flow rate ratio between branches, q, and the extrapolated Mach number in the common branch, M{sub 3}{sup *}, for all the different flow types studied. The extrapolated properties up to the junction are calculated, from measurement sections, subtracting the frictional losses using the Fanno fluid flow model. These two parameters or global correlations, K = K(M{sub 3}{sup *},q), can be easily implemented as boundary conditions into 1-D global simulation codes. (author)

42 ENGINEERING↗

A decade of progress in understanding and managing legacy well integrity for geologic carbon storage

This study reviews a decade of research progress in legacy well integrity and risk management for geologic carbon storage (GCS) to commemorate the 20 th anniversary of the Intergovernmental Panel on Climate Change’s 2005 Special Report on Carbon Capture and Storage. In the past ten years, legacy well research has benefited from global efforts to constrain emissions from abandoned oil and gas wells, a continued focus on well materials performance in the presence of CO 2 -rich fluids, and practical experience gained through GCS implementation. Field measurements of abandoned well emissions show that leakage is not universal or catastrophic but forms a continuum of low-to-moderate fluxes that depend on isolation integrity and environmental attenuation. Materials research has constrained the conditions under which Portland cements exhibit self-sealing and non-sealing behaviors, and has identified the impact of geomechanical properties, non-uniform pathway apertures, multi-phase flow, and impurities in the CO 2 stream, on leakage pathways as important new areas for investigation. GCS projects at brownfield sites have inspired the creation of new workflows that integrate various tools and technologies to manage legacy well leakage risks. GCS implementation has also motivated a push towards scenario-based well modeling that directly informs permit applications. These advances inspire new research questions for the coming decade, particularly around the level of legacy well leakage risk that is environmentally acceptable and tolerable to stakeholders when sequestering millions of tonnes of CO 2 annually.

Carbon capture and storage↗

Above zone pressure interpretation for leaky well characterization and its identification from leaky caprock/fault

Pressure transient analysis has long been used for reservoir characterization. Above-zone (AZ) pressure has been recently investigated for inferring leakage pathway characteristics in leakage events from subsurface injection operations. The recorded pressure in the AZ should be purely related to leakage and therefore it can be safely inverted to deduce leakage characteristics. It is crucial to evaluate fluid leakage through abandoned wells to plan for further measurements of leakage prevention. However, the recorded AZ leakage signal may not be related to leaky well(s). Therefore, identification and spatial investigation of well leakage is required for leakage evaluation. Here in this paper, we propose a pressure interpretation method for early detection of leaky pathways, applying two observation points in the AZ. We distinguish leaky well, fault and caprock based on their corresponding flow regime identification. We show that the pressure difference of the two observation wells can be applied as a proxy for unknown leakage rate, which is crucial for leakage identification as well as characterization. Results show that the estimated location of the leaky well, leakage coefficient, and the leakage rate are in good agreement with the actual values. The estimated leakage coefficient of the leaky well can be used to evaluate well leakage in multiphase systems such as carbon dioxide leakage in deep saline aquifers.

02 PETROLEUM↗

Distribution of bisphenol A into tissues of adult, neonatal, and fetal Sprague-Dawley rats

Bisphenol A (BPA) is an important industrial chemical used in the manufacture of polycarbonate plastic products and epoxy resin-based food can liners. The presence of BPA metabolites in urine of > 90% of Americans aged 6-60 suggests ubiquitous and frequent exposure in the range of 0.02-0.2 {mu}g/kg bw/d (25th-95th percentiles). The current study used LC/MS/MS to measure placental transfer and concentrations of aglycone (receptor-active) and conjugated (inactive) BPA in tissues from Sprague-Dawley rats administered deuterated BPA (100 {mu}g/kg bw) by oral and IV routes. In adult female rat tissues, the tissue/serum concentration ratios for aglycone BPA ranged from 0.7 in liver to 5 in adipose tissue, reflecting differences in tissue perfusion, composition, and metabolic capacity. Following IV administration to dams, placental transfer was observed for aglycone BPA into fetuses at several gestational days (GD), with fetal/maternal serum ratios of 2.7 at GD 12, 1.2 at GD 16, and 0.4 at GD 20; the corresponding ratios for conjugated BPA were 0.43, 0.65, and 3.7. These ratios were within the ranges observed in adult tissues and were not indicative of preferential accumulation of aglycone BPA or hydrolysis of conjugates in fetal tissue in vivo. Concentrations of aglycone BPA in GD 20 fetal brain were higher than in liver or serum. Oral administration of the same dose did not produce measurable levels of aglycone BPA in fetal tissues. Amniotic fluid consistently contained levels of BPA at or below those in maternal serum. Concentrations of aglycone BPA in tissues of neonatal rats decreased with age in a manner consistent with the corresponding circulating levels. Phase II metabolism of BPA increased with fetal age such that near-term fetus was similar to early post-natal rats. These results show that concentrations of aglycone BPA in fetal tissues are similar to those in other maternal and neonatal tissues and that maternal Phase II metabolism, especially following oral administration, and fetal age are critical in reducing exposures to the fetus. - Highlights: > Studies of BPA in rat tissues showed placental transfer and fetal metabolism. > Levels in fetus are similar to maternal tissues. > Fetal metabolism can reduce levels.

60 APPLIED LIFE SCIENCES↗

Numerical Simulation and Experimental Study of the Gas–Solid Flow Behavior Inside a Full-Loop Circulating Fluidized Bed: Evaluation of Different Drag Models

Both experimental and computational studies of the fluidization of high-density polyethylene (HDPE) particles in a small-scale full-loop circulating fluidized bed (CFB) are conducted. Experimental measurements of pressure drop are taken at various locations along the bed. The solids circulation rate is measured with an advanced particle image velocimetry (PIV) technique. Bed height of the quasi-static region in the standpipe is also measured. Comparative numerical simulations are performed with a computational fluid dynamics solver utilizing a discrete element method (CFD-DEM). Here, this paper examines the effect of different drag laws used in the CFD simulations through a detailed and direct comparison with experimental data from a small-scale, full-loop circulating fluidized bed. The Hill–Koch–Ladd drag correlation was shown to have good agreement with respect to system component pressure drop and inventory height in the standpipe.

42 ENGINEERING↗

Note: Calibration of atomic force microscope cantilevers using only their resonant frequency and quality factor

A simplified method for calibrating atomic force microscope cantilevers was recently proposed by Sader et al. [Rev. Sci. Instrum. 83, 103705 (2012); Sec. III D] that relies solely on the resonant frequency and quality factor of the cantilever in fluid (typically air). This method eliminates the need to measure the hydrodynamic function of the cantilever, which can be time consuming given the wide range of cantilevers now available. Using laser Doppler vibrometry, we rigorously assess the accuracy of this method for a series of commercially available cantilevers and explore its performance under non-ideal conditions. This shows that the simplified method is highly accurate and can be easily implemented to perform fast, robust, and non-invasive spring constant calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗