Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEEDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Evaluation of the Risk of Precipitating Aluminum in Hanford DFLAW Feed Compositions

The Hanford Tank Operations Contractor (TOC), Washington River Protection Solutions (WRPS), developed the Tank Waste Disposition Integrated Flowsheet that defines process flowsheets during each phase of the Waste Treatment and Immobilization Plant transition to full operation. The TOC requested Savannah River National Laboratory (SRNL) personnel to perform a review of gibbsite precipitation risks for the Low-Activity Waste Pretreatment System (LAWPS) and Tank Side Cesium Removal (TSCR) processes at Hanford during the Direct Feed Low-Activity Waste (DFLAW) operational phase of the Hanford Low-Activity Waste (LAW) Vitrification Facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 30H (HTF-30-18-96, -97), Tank 32H (HTF-32-18-98, -99), and Tank 37H (HTF-37-18-100, -101) Samples for Support of the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator

SRNL analyzed samples from Tank 30H, Tank 32H, and Tank 37H to support the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator system. The six samples from Tanks 30H, 32H, and 37H all contain highly concentrated salt solutions with sodium concentrations ranging from 11.8 M to 15.7 M. The samples from Tank 30H show somewhat higher concentrations of the major cations and anions in the sub-surface sample than the surface sample indicating some stratification within the tank. The two Tank 32H samples show similar concentrations of the major anions and cations between the surface and sub-surface samples. The sub-surface sample from Tank 37H shows higher concentrations for most species than the surface sample indicating some stratification within this tank as well. For all six samples, the sum of the major cations versus the sum of the major anions shows a difference of <10% providing an indication of good data quality. The VDS and surface samples from Tank 30H, Tank 32H, and Tank 37H all show silicon concentrations below 30 mg/L except for the Tank 30H VDS with a concentration of 87 mg/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

BTL Plant Operation with Corn Stover Feed

Inputs and outputs for Fischer-Tropsch (FT) diesel production by a 5,000-barrel-per-day BTL plant using corn stover feed. Includes scenarios for carbon capture and sequestration (CCS) and autothermal reforming (ATR). Naphtha is a co-product. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=5B2F9747-8A07-400D-B3B4-810B06693573

09 BIOMASS FUELS↗

BTL Plant Operation with SRWC Feed

Inputs and outputs for Fischer-Tropsch diesel production by a 5,000-barrel-per-day BTL plant using SRWC feed. Includes scenarios for carbon capture and sequestration (CCS) and autothermal reforming (ATR). Naphtha is a co-product. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=BA63239E-4263-4180-82BD-D9DBEA0E01EB

09 BIOMASS FUELS↗

BTL Plant Operation with Switchgrass Feed

Inputs and outputs for FTD production by a 5,000-barrel-per-day BTL plant using switchgrass feed. Includes scenarios for carbon capture and sequestration (CCS) and autothermal reforming (ATR). Naphtha is a co-product. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=FF57463F-460F-4CE1-A4EC-26850B489EBB

09 BIOMASS FUELS↗

CBTL Plant Operation with Coal and Corn Stover Feed

Inputs and outputs for Fischer-Tropsch diesel production by a 30,000 to 50,000 barrel per day CBTL plant using Illinois No. 6 coal and Corn Stover feed. Includes scenarios for CCS and ATR (autothermal reforming). Naphtha is a co-product. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=12141C35-146E-48F2-B9E3-B0548F470835

01 COAL, LIGNITE, AND PEAT↗

CBTL Plant Operation with Coal and SRWC Feed

Inputs and outputs for Fischer-Tropsch diesel production by a 30,000 to 50,000 barrel per day CBTL plant using Illinois No. 6 coal and SRWC feed. Includes scenarios for CCS and ATR (autothermal reforming). Naphtha is a co-product. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=AA10EA47-215C-48B9-A29A-CE1B60E21F56

01 COAL, LIGNITE, AND PEAT↗

CBTL Plant Operation with Coal and Switchgrass Feed

Inputs and outputs for Fischer-Tropsch diesel production by a 30,000 to 50,000 barrel per day CBTL plant using Illinois No. 6 coal and switchgrass feed. Includes scenarios for CCS and ATR (autothermal reforming). Naphtha is a co-product. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=32527237-391E-4979-BDFD-499F34B68AAD

01 COAL, LIGNITE, AND PEAT↗

CTL Plant Operation with Bituminous Coal Feed

Inputs and outputs for Fischer-Tropsch diesel (FTD) production by a 50,000 barrel per day BTL plant using Illinois No. 6 bituminous coal feed. Includes scenarios for CCS and ATR (autothermal reforming). Naphtha is a co-product of all CTL cases. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=8BCFE720-8B54-4140-AA92-AC56B346268F

01 COAL, LIGNITE, AND PEAT↗

Analysis of Tank 30H (HTF-30-19-33, -34), Tank 32H (HTF-32-19-35, -36), and Tank 37H (HTF-37-19-53, -54) Samples for Support of the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator

SRNL analyzed samples from Tank 30H, Tank 32H, and Tank 37H to support the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator system. The six samples from Tanks 30H, 32H, and 37H all contain highly concentrated salt solutions with sodium concentrations ranging from 13.8 M to 16.9 M. Hydroxide is the dominant anion in all of the samples followed by nitrate and nitrite. The preponderance of the analytical determinations (density, anions, cations) on all three tanks show slightly higher concentrations of solute in the sub-surface sample than in the surface sample, indicating some stratification within the tanks. With the exception of the Tank 30H VDS, all of the samples are somewhat more concentrated compared with the compositions of the previous samples. The sum of the major cations versus the sum of the major anions show a difference of <5% for all of the samples indicating good data quality for the non-radioactive analytes in the table. The silicon concentrations measured in the VDS and surface samples from Tank 30H, Tank 32H, and Tank 37H were all below detection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 30H (HTF-30-19-33, -34), Tank 32H (HTF-32-19-35, -36), and Tank 37H (HTF-37- 19-53, -54) Samples for Support of the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator

SRNL analyzed samples from Tank 30H, Tank 32H, and Tank 37H to support the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator system. The six samples from Tanks 30H, 32H, and 37H all contain highly concentrated salt solutions with sodium concentrations ranging from 13.8 M to 16.9 M. Hydroxide is the dominant anion in all of the samples followed by nitrate and nitrite. The preponderance of the analytical determinations (density, anions, cations) on all three tanks show slightly higher concentrations of solute in the sub-surface sample than in the surface sample, indicating some stratification within the tanks. With the exception of the Tank 30H VDS, all of the samples are somewhat more concentrated compared with the compositions of the previous samples. The sum of the major cations versus the sum of the major anions show a difference of <5% for all of the samples indicating good data quality for the non-radioactive analytes in the table. The silicon concentrations measured in the VDS and surface samples from Tank 30H, Tank 32H, and Tank 37H were all below detection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Acetonitrile Destruction in ETF Feed Solutions by UV/OX and Persulfate (Final Report)

The Hanford Site Effluent Treatment Facility (ETF) currently treats aqueous waste streams that include condensates from the 242-A evaporator, leachate from the Environmental Restoration Disposal Facility (ERDF), as well as laboratory wastes and, in the future, will treat liquid effluents from the Hanford Waste Treatment and Immobilization Plant (WTP) and Integrated Disposal Facility (IDF) leachate. Liquid effluents from the WTP will have significant concentrations of acetonitrile. Acetonitrile is formed by reaction of nitrates and sugar in the WTP low activity waste (LAW) melters and is prevalent in the submerged bed scrubber (SBS) and wet electrostatic precipitator (WESP) liquid effluents from WTP off-gas treatment. When these liquids are concentrated in the WTP Effluent Management Facility (EMF) evaporator in the direct feed low activity waste (DFLAW) flow-sheet, testing has shown that the majority of the acetonitrile partitions to the evaporator condensate. Since the evaporator condensate is directed to the ETF, this creates a potential issue with the ETF waste acceptance criteria and, specifically, the ETF Delisting Modification treatability envelope limits. Consequently, there is a need to assess possible mitigation approaches, one of which involves identification and assessment of potential treatment processes to destroy the acetonitrile, which is the subject of the present report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Ammonium and Iodine Decontamination Factors for Hanford's Waste Treatment and Immobilization Plant Feed in the Effluent Treatment Facility

Savannah River National Laboratory (SRNL) reviewed the unit operations in the Effluent Treatment Facility (FTP) at the Hanford site to estimate the partitioning of iodine and ammonia when processing Waste Treatments and Immobilization Plant (WTP) feed. The evaluation consisted of literature and vendor data reviews and no experiments were performed. A list of the unit operations reviewed, along with estimated decontamination factors (DFs) for both iodine and ammonium are shown in the table below. With the exception of the Peroxide Decomposer, reasonable estimations of the decontamination factors for all operations are provided.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY2021 Rotating Bed Reactor for Iodine Removal from ETF Feed to Support DFLAW Start-Up

In FY20, Washington River Protection Solutions, LLC (WRPS) began a program of work to evaluate potential technologies for removal of iodine from the ETF feed. Work at the Pacific Northwest National Laboratory (PNNL) focused on ion exchange media and conventional column based deployment while Atkins and VSL focused on ion exchange media in a Rotating Bed Reactor (RBR) system. In the RBR system, the ion exchange media is loaded into a packed bed, which is rotated in the liquid to be treated. The work described in this report builds on the results from FY20 work, in particular, with regard to improving iodate removal, extending the data set to support process modeling, further comparison of RBR versus column performance, and RBR scale-up testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Full-scale FEED Study for Retrofitting the Prairie State Generating Station with an 816 MWe Capture Plant using Mitsubishi Heavy Industries Post-Combustion CO 2 Capture Technology

A full front-end engineering design (FEED) study to for a carbon capture system for Unit #2 (816 MWe) at the Prairie State Generating Company’s (PSGC) Energy Campus in Marissa, IL based on the KM CDR Process CO 2 capture technology from Mitsubishi Heavy Industries (MHI) using their proprietary solvent KS-21TM. If built this carbon capture plant would be the world's largest to date. The cost of capture of 100 percent of the plant emissions was calculated to be $43.42 per metric tonne of CO 2 based on levelized costs for 30 years of operation (85% capacity factor), and includes Interest on Debt and Return on Equity During Operation.

01 COAL, LIGNITE, AND PEAT↗

FEED Study for Climeworks Direct Air Capture at a California Geothermal Facility with Long-Term Storage (Final Scientific/Technical Report)

The overall objective of the project is to execute and complete a front-end engineering and design (FEED) study of an advanced Direct Air Capture (DAC) and Storage (DAC+S) system that is capable of removing and sequestering a minimum of 5,000 tonne/yr of CO 2 from the air based on cradle-to-gate life cycle assessment (LCA). The project will examine retrofitting and utilizing an existing domestic geothermal resource. The selected DAC system will be technology from Climeworks AG (Climeworks) that consists of an adsorption-desorption process to remove CO 2 from ambient air by using a selective filter. The geothermal host site is operated by Ormat Technologies Inc. (ORMAT). The DAC system will capture CO 2 using thermal energy from the host geothermal resource. This Final Scientific/Technical Report is a collection of the deliverables for the project. The project team was not able to successfully complete all the necessary tasks for this project. Shortly after the start of the project, two (2) project partners removed themselves from the study. The Awardee attempted to find a replacement for the direct air capture technology provider and geothermal energy provider. Due to this the awardee submitted a letter of cancellation for the project, letter is attached in the appendix. No funds were expended during the course of the project.

15 GEOTHERMAL ENERGY↗

Characterization of Precipitate Reactor Feed Tank (PRFT) Batches 15, 22, and 26 from the Defense Waste Processing Facility (DWPF)

The Savannah River Site (SRS) Defense Waste Processing Facility (DWPF) processes a Monosodium Titanate/Sludge Solids (MST/SS) waste stream received from the Salt Waste Processing Facility (SWPF) via the Precipitate Reactor Feed Tank (PRFT). During processing, DWPF is required to provide evidence of compliance with the Waste Acceptance Product Specifications (WAPS) to ensure acceptance of their vitrified high-level waste (HLW) into the Civilian Radioactive Waste Management System. Production Records must document the constituents of the MST/SS material in the PRFT from each salt batch (StB) processed at SWPF. Savannah River Mission Completion (SRMC) has requested Savannah River National Laboratory (SRNL) to analyze PRFT samples representing each SWPF salt batch for thirty-two radionuclides. Additionally, elemental analysis of PRFT slurry and MST/SS solids was performed to aid SRMC in further refinement of the inputs and assumptions used in future frit development and Material Tracking Program calculations. The analyses of PRFT Batches 15, 22, and 26, which corresponds to material from the processing of StB4, StB5, and StB7, respectively, are reported herein. The unwashed dried solids of the PRFT batches were found to be 86-87% MST. Additionally, the total sulfur values are well below the assumed 982 mg of sulfate/kg of PRFT slurry used in Material Tracking Program calculations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗