Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Systems Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Preliminary Scaling and controls Analysis of an FHR-HTSE System Idaho National Laboratory Summer 2013 Final Report

For new nuclear reactor system designs to be approved by regulatory agencies like the Nuclear Regulatory Commission (NRC), the details of system operation must be validated with respect to standards of safety, control, and output. A scaled experiment that replicates certain properties of the system can be used to validate compliance with regulatory standards, while avoiding the prohibitive cost and labor required to develop a fully functional prototype system; therefore, designing such an experiment is of special interest to current efforts to develop hybrid energy systems (HES) that integrate small modular reactors (SMRs), renewable energy systems, and industrial process applications such as hydrogen production and desalination. In addition, a scaled experiment can be an economical method of analyzing the interconnections between HES components and understanding the time constants associated between inter-component energy and information flows. This report discusses the results of a preliminary scaling analysis done for the primary loop of a 300 MWth Fluoride-Salt-Cooled High Temperature Reactor (FHR) that is coupled with a High-Temperature Steam Electrolysis system (HTSE), as well as the basic control logic that governs the primary components and the necessary hardware to achieve optimal functionality. The scaled facility will be a 1 MWth system that uses Dowtherm A as the simulant fluid for Flibe (the coolant of choice for the primary loop of molten salt reactors), and can validate the heat transfer and steady-state operational requirements of the 300 MWth prototype. The scaled facility matches the Prandtl and Reynolds numbers associated with steady-state operation of the FHR-HTSE’s primary loop without having to deal with very high temperatures, flow rates, or power inputs. This will allow the facility to run experiments that analyze various thermophysical and fluid-dynamic properties that characterize reactor operation, such as pressure drops, radial temperature distribution, heat exchanger conditions. The facility also has potential to integrate additional components of the prototype system, such as intermediate thermal-hydraulics loops, real-time grid-demand data, energy storage, and HTSE.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Preliminary Scaling and controls Analysis of an FHR-HTSE System Idaho National Laboratory Summer 2013 Final Report

For new nuclear reactor system designs to be approved by regulatory agencies like the Nuclear Regulatory Commission (NRC), the details of system operation must be validated with respect to standards of safety, control, and output. A scaled experiment that replicates certain properties of the system can be used to validate compliance with regulatory standards, while avoiding the prohibitive cost and labor required to develop a fully functional prototype system; therefore, designing such an experiment is of special interest to current efforts to develop hybrid energy systems (HES) that integrate small modular reactors (SMRs), renewable energy systems, and industrial process applications such as hydrogen production and desalination. In addition, a scaled experiment can be an economical method of analyzing the interconnections between HES components and understanding the time constants associated between inter-component energy and information flows. This report discusses the results of a preliminary scaling analysis done for the primary loop of a 300 MWth Fluoride-Salt-Cooled High Temperature Reactor (FHR) that is coupled with a High-Temperature Steam Electrolysis system (HTSE), as well as the basic control logic that governs the primary components and the necessary hardware to achieve optimal functionality. The scaled facility will be a 1 MWth system that uses Dowtherm A as the simulant fluid for Flibe (the coolant of choice for the primary loop of molten salt reactors), and can validate the heat transfer and steady-state operational requirements of the 300 MWth prototype. The scaled facility matches the Prandtl and Reynolds numbers associated with steady-state operation of the FHR-HTSE’s primary loop without having to deal with very high temperatures, flow rates, or power inputs. This will allow the facility to run experiments that analyze various thermophysical and fluid-dynamic properties that characterize reactor operation, such as pressure drops, radial temperature distribution, heat exchanger conditions. The facility also has potential to integrate additional components of the prototype system, such as intermediate thermal-hydraulics loops, real-time grid-demand data, energy storage, and HTSE.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Stochastic Optimization and Uncertainty Quantification of Natrium-based Nuclear-Renewable Energy Systems for Flexible Power Applications in Deregulated Markets

Rapid integration of variable renewable energy sources (VRES) has made modeling and stochastic optimization of hybrid energy systems crucial for studying their long-term performance and viability. However, most studies have focused on just historical data, which may be unreliable for capturing short-term fluctuations, rare events, and long-term patterns of energy demand, price, and the variability of renewable energy sources. For this study, optimal synthetic time series models were developed using Wasserstein distance. The models were validated by comparing the key statistical measures against those of the historical data. They were then used to optimize the integrated Natrium-style advanced energy systems and their long-term (30 years) economics. The stochastic model performs bi-level optimization to find the optimal sizes for the balance of plant and thermal energy storage, while also optimizing energy dispatch to achieve the maximum net present value. In studies of two deregulated markets (California ISO and the Electric Reliability Council of Texas), the integrated Natrium-style system performed better in CAISO than in ERCOT, given higher and more consistent electricity prices during peak-demand periods. The potentially enlarged cost associated with the variable operation and maintenance of the TES system also plays a significant role in driving the system sizing, thus its impacts on the system are investigated in detail through comparison against a baseline case. The study also finds that the bi-level optimization results based on stochastic gradient descent closely match the grid search results. The uncertainty quantification of the stochastic signals provides further NPV-related insights and probability distributions for the case studies. The normal standard error of the mean of NPV for the case with and without TES VOM for CAISO were found to be 7.73M (plus-minus sign) 1.09M USD and 104.99M (plus-minus sign) 1.25M USD, respectively based on a 95% confidence. Given the relatively small NPV variance based on 150 samples, the analysis affords the most robust possible prediction of the techno-economic performance of the integrated Natrium-style energy systems.

25 ENERGY STORAGE↗

Generic modelling and optimal day-ahead dispatch of micro-energy system considering the price-based integrated demand response

As an extension of micro-grid, micro-energy system (MES) is one of the important carriers for energy utilization in the future, and using energy prices as a controllable resource is conducive to improving the optimization potential of MES. Firstly, based on the energy hub model, a generic method for modelling the steady-state energy balance equation of MES is proposed. Then, considering the multi-energy substitution effect in the background of multi-energy coupling, the concept of price-based integrated demand response (P-IDR) is introduced. Meanwhile, based on the price elasticity theory and the discrete choice theory, the energy timing transfer characteristics and energy substitution characteristics in P-IDR is modelled. Furthermore, after taking into account the P-IDR, an MINLP model for day-ahead dispatch of MES is built, and a generalized benders decomposition method is used for solution. Case studies are conducted on an MES to verify the effectiveness of the proposed modelling method. Here, the result shows that it is beneficial to improve renewable energy accommodation and reduce the peak and off-peak difference of energy load when the P-IDR is deployed. In addition, consider the energy substitution characteristics can reduce the user’s cost on energy purchase and be more in line with the user’s rational consumption behaviour.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Potential of Utilizing Thermal Energy Storage Integrated Ground Source Heat Pump System to Reshape Electricity Demand in the United States

Each year, more than 20% of electricity generated in the United States is consumed for meeting the thermal demands (e.g., space cooling, space heating, and water heating) in residential and commercial buildings. Integrating thermal energy storage (TES) with building’s HVAC systems has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable generation and the demand of buildings. A novel ground source heat pump (GSHP) system integrated with underground thermal energy storage (UTES) has been proposed to level the electric demand of buildings while still satisfying their thermal demands. This study assessed the potential impacts of the proposed system with a bottom-up approach. The impacts on the electricity demand in various electricity markets were quantified. The results show that, within the capacity of the existing electric grids, the maximum penetration rate of the proposed system in different wholesale markets could range from 51% to 100%. Altogether, about 46 million single-family detached houses can be retrofitted into the proposed system without increasing the annual peak demand of the corresponding markets. By implementing the proposed system at its maximum penetration rate, the grid-level summer peak demand can be reduced by 9.1% to 18.2%. Meanwhile, at the grid level, the annual electricity consumption would change by –12% to 2%. The nationwide total electricity consumption would be reduced by 9%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Energy Justice and Equity Impacts from Replacing Peaker Plants with Energy Storage

Transitions to low-carbon energy systems are essential to mitigating and adapting to climate change. Energy storage systems are a key component in achieving a viable decarbonized electric grid. However, decarbonization alone does not guarantee a fairer, more inclusive, or socially just energy system. Energy equity and justice should be integrated in energy system transitions to ensure benefits and burdens are shared equitably. In this paper, we discuss the relationship between energy storage and social equity by assessing the use of energy storage to replace natural gas-fired (NG) peaker plants. Peaker plants are disproportionately located near disadvantaged communities and tend to be older and high emitters of health-affecting fine particulate matter and other pollutants. This paper investigates the equity implications of NG peaker plant replacements with battery energy storage in the context of Washington State’s peaker plants to highlight the human-centered values of retiring the plants. The study performed production cost simulations using the latest Western Electric Coordinating Council Anchor Dataset 2030 case and found that total generation cost, locational marginal price, and total annual emissions were reduced with the replacements. These reductions will have equity benefits on local communities including access to clean air, enhanced health outcomes, and energy burden reductions.

Tarekegne, Bethel W.↗

Multicarrier Energy Systems: Shaping Our Energy Future

Multicarrier energy systems (MCESs) are characterized by strong coordination in operation and planning across multiple energy vectors and/or sectors to deliver reliable, cost-effective energy services to end users/customers with minimal impact on the environment. They have efficiency and flexibility benefits and are deployed in large and small scales on the supply and demand sides and at the network level but are more complex to control and manage. Here, MCESs are reviewed in the context of future low carbon energy systems based on electrification and very high variable renewable energy penetrations. Fully exploiting these systems requires some cost reductions, more sophisticated operations enabled by standardized communications and control capabilities detailed planning paradigms, and addressing their corresponding economic challenges. All these point toward the direction of analysis, markets, and technology research and development coupled with better policy and regulatory frameworks. One futuristic vision of a very low carbon energy system is proposed that illustrates potential pathways to an MCES-dominated energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Future energy system challenges for Africa: Insights from Integrated Assessment Models

Although Africa’s share in the global energy system is only small today, the ongoing population growth and economic development imply that this can change significantly. In this paper, we discuss long-term energy developments in Africa using the results of the LIMITS model inter-comparison study. The analysis focusses on the position of Africa in the wider global energy system and climate mitigation. The results show a considerable spread in model outcomes. Without specific climate policy, Africa’s share in global CO 2 emissions is projected to increase from around 1-4% today to 3-23% by 2100. In all models, emissions only start to become really significant on a global scale after 2050. Furthermore, by 2030 still around 50% of total household energy use is supplied through traditional bio-energy, in contrast to existing ambitions from international organisations to provide access to modern energy for all. After 2050, the energy mix is projected to converge towards a global average energy mix with high shares of fossil fuels and electricity use. Finally, although the continent is now a large net exporter of oil and gas, towards 2050 it most likely needs most of its resources to meet its rapidly growing domestic demand. With respect to climate policy, the rapid expansion of the industrial and the power sector also create large mitigation potential and thereby the possibility to align the investment peak in the energy system with climate policy and potential revenues from international carbon trading.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electrification of residential and commercial buildings integrated with hybrid renewable energy systems: A techno-economic analysis

Here, this study assesses the techno-economic viability of city-scale building electrification, comparing a base case scenario with conventional HVAC systems to an electrified scenario with heat pump systems. EnergyPlus simulations reveal a 28% increase in annual electricity consumption in the electrified scenario, shifting the peak consumption from summer to winter with a 49% surge. Hybrid renewable energy systems (HRESs) are then evaluated using HOMER Pro, considering renewable penetration from 0% to 100%. The net present cost (NPC) of the base case and electrified scenarios range from $\$10.34$ to $\$24.38$ billion and $\$8.79$ to $\$50.31$ billion, respectively. Sensitivity analysis explores the impact of carbon tax, fuel price, and renewable subsidies on HRESs in the electrified scenario. Results indicate that applying a carbon tax up to $\$120$/tonne of CO 2 increases the optimum renewable fraction from 5% to 26%, while higher fuel prices and renewable subsidies further enhance the feasibility by shifting the optimum renewable fraction to 60% and 54%, respectively, demonstrating the interplay between economic factors and renewable integration in electrified urban contexts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 11: Renewable Microgrids as a Foundation of the Future Sustainable Electrical Energy System

Renewable microgrids are an integral part of the future sustainable energy system. This chapter focuses on the role of renewable energy-based microgrids in the electricity system transformation. It is seen as a foundation that complements large-scale generation plants and high-voltage transmission lines by providing additional flexibility and resilience. This flexibility and resilience are crucial for balancing the energy system and ensuring its long-term sustainability, given the changing supply and demand patterns due to rooftop solar photovoltaics (PV), battery storage, electric mobility, and heat pumps. It is also an opportunity for residential and commercial consumers to become active participants in the energy market. Innovation, new technologies and business models will act as the key enabler for this transformation. The regulatory restructuring of the energy market will be crucial for successful integration of prosumers and aggregated energy communities. The chapter presents the vision of a sustainable, decentralized, and digitized energy future including market potential, most innovative case study projects and start-up companies, and the shifts needed in the regulatory landscape.

battery storage↗

Laboratory Validation of Integrated Lighting Systems Retrofit Performance and Energy Savings

Light-emitting diodes (LED) fixtures and lamps have emerged as leading technologies for general illumination and are a well-established energy efficiency retrofit measure in commercial buildings (from around 2% of installed fixtures and lamps in 2013 to 28% by 2020). Retrofit approaches that integrate elements, such as networked controls, daylight dimming, and advanced shade technologies lag in comparison. Integrated retrofits have been shown to increase savings over single end-use retrofits, but are perceived as higher complexity and risk. More validation of integrated lighting system performance is needed. This study presents results from laboratory testing of three packages combining fixtures, networked controls, task tuning, and daylight dimming, advanced shades, and lighting layout changes. We characterize performance in perimeter open-office zones, finding energy savings from 20% for daylight dimming and automated shades (no LED retrofit) to over 70% for LED retrofits with advanced controls and shades or lighting layout changes. We present some implementation details, including lessons learned from installation and commissioning in the laboratory setting. We also discuss cost-benefit analysis approaches for the types of packages presented, including the need to quantify and incorporate energy and non-energy benefits for advanced shades packages, which enhance occupant comfort but add significant cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Repurposing Fossil-Fueled Assets For Energy Storage

The annual retirement of U.S. coal-fired electricity generation units (CF-EGU) is at an all-time high and is expected to continue. This loss of reliable baseload generation, combined with predicted growth of variable renewable energy (VRE) generation, is expected to stress grid reliability as the number of load-following resources drops below the experienced load variability. Many regions are already experiencing challenges, and fossil retirement-related warnings by the North American Electric Reliability Corp. are becoming more dire. All CF-EGU retirements pose significant challenges to asset owners, local workforces, and their communities. Repurposing a retiring CF-EGU as a long-duration energy storage plant can address these challenges and offer a suite of additional benefits to asset owners, the grid, and society. This project performed a techno-economic evaluation and assessment of repurposing a Duke Energy fossil-fueled asset (in particular, a coal plant) into an energy storage system by integrating the retiring asset with a Malta long duration Pumped Heat Energy Storage (PHES) system. The project validated the technoeconomic benefits of repurposing retiring coal plants into long-duration energy storage using Malta’s PHES. Key findings for this project are summarized below: (1) Technical: (a) Retiring coal plants (and other steam turbine fossil generation) can be repurposed to enable the clean energy transition using Malta’s technology. (b) For older retiring coal plants, repurposing the site and electrical interconnection for a standalone PHES plant is the most economically favorable option. (c) For newer coal plants where there is also a local peaking capacity need, repowering the steam cycle into a hybrid integration with PHES is attractive. (d) A process was developed to assist fossil generation owners in choosing the best path for each plant’s circumstances. (2) Economic (a) Communities facing economic challenges caused by the retirement of fossil generation would benefit from repurposing the plant as long-duration energy storage using Malta’s PHES. (b) On a $/MW basis, repowering retiring coal units into Malta PHES plants can maintain the same number and types of jobs and economic activity. (c) For a 70% carbon reduction scenario, a 10-hour Malta PHES plant is more economic for the asset owner than similar-power 4-hour batteries. This project showed that repurposing a retiring coal unit into thermal energy storage, by integrating it with a Malta PHES system, makes techno-economic sense. At least two integration options are available, with the optimal solution depending on the coal plant and its location. Repurposing retiring coal plant into energy storage results in economic benefits for the plant owner and local communities.

20 FOSSIL-FUELED POWER PLANTS↗

Interleaved Cuk Converter Wave Energy System With Advanced Control and Grid Support Functions for Seamless Integration: Preprint

This paper presents an innovative wave energy conversion system employing an interleaved Cuk converter and advanced nonlinear control for seamless integration with the grid. The proposed system utilizes the interleaved Cuk converter for efficient power extraction on the DC side, while an inverter facilitates power transfer to the grid or load on the AC side. A sophisticated nonlinear control architecture based on Lyapunov energy functions ensures stable and optimal operation under varying wave conditions. Case study results demonstrate the effectiveness of the proposed system, highlighting its ability to efficiently harness wave energy and seamlessly integrate with the grid, thus paving the way for sustainable and reliable renewable energy generation. The overall system is verified via computer simulations based on MATLAB/Simulink and various case study results are presented.

HYDRO ENERGY,TIDAL AND WAVE POWER↗

Life Prediction Model for Grid-Connected Li-ion Battery Energy Storage System

Lithium-ion (Li-ion) batteries are being deployed on the electrical grid for a variety of purposes, such as to smooth fluctuations in solar renewable power generation. The lifetime of these batteries will vary depending on their thermal environment and how they are charged and discharged. To optimal utilization of a battery over its lifetime requires characterization of its performance degradation under different storage and cycling conditions. Aging tests were conducted on commercial graphite/nickel-manganese-cobalt (NMC) Li-ion cells. A general lifetime prognostic model framework is applied to model changes in capacity and resistance as the battery degrades. Across 9 aging test conditions from 0oC to 55oC, the model predicts capacity fade with 1.4% RMS error and resistance growth with 15% RMS error. The model, recast in state variable form with 8 states representing separate fade mechanisms, is used to extrapolate lifetime for example applications of the energy storage system integrated with renewable photovoltaic (PV) power generation.

25 ENERGY STORAGE↗

The Implications of Global Change for the Co-Evolution of Argentina's Integrated Energy-Water-Land Systems

This study seeks to understand how Argentina’s energy, water, and land (EWL) systems will co-evolve under a representative array of human and earth system influences, including socioeconomic change, climate change, and climate policy. To capture Argentina’s sub-national EWL dynamics in the context of global change, we couple the Global Change Analysis Model with a suite of consistent, gridded sectoral downscaling models to explore multiple stakeholder-engaged scenarios. Across scenarios, Argentina has the economic opportunity to use its vast land resources to satisfy growing domestic and international demand for crops, such as oil (e.g., soy) and biomass. The human (rather than earth) system produces the most dominant changes in mid-century EWL resource use. A Reference scenario characterized by modest socioeconomic growth projects a 40% increase in Argentina’s agricultural production by 2050 (relative to 2020) by using 50,000 km 2 of additional cropland and 40% more water. A Climate Policy scenario designed to achieve net-zero carbon emissions globally shortly after mid-century projects that Argentina could use 100,000 km 2 of additional land (and 65% more water) to grow biomass and other crops. The burden of navigating these national opportunities and challenges could fall disproportionately on a subset of Argentina’s river basins. The Colorado and Negro basins could experience moderate-to-severe water scarcity as they simultaneously navigate substantial irrigated crop demand growth and climate-induced declines in natural water availability. Argentina serves as a generalizable testbed to demonstrate that multi-scale EWL planning challenges can be identified and managed more effectively via integrated analysis of coupled human-earth systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

AUXILIARY FEEDWATER REHEATING TO MITIGATE PRIMARY AND SECONDARY SIDE THERMAL STRESSORS

A consequence of operating steam cycles under time varying loads, is the variability of the feedwater temperature entering the bottom of the steam generators. This variability is a direct result of changes in turbine impulse pressure and subsequently turbine tap pressures in response to the load changes, with a reduction in feed temperature during periods of low turbine demand. These fluctuations over time will increase thermal cycling and threaten the integrity of the tube bundle as well as other components in the feed system. Sensible heat, TES systems have been shown to be an effective load management strategy allowing nuclear reactor systems to operate at effectively 100% full power while storing excess thermal energy for recovery later. A byproduct of the TES system is the availability of large amounts of low grade waste heat that can be used for ancillary applications, including auxiliary feed heating during periods of low turbine demand. The addition of an auxiliary feed heater at the end of the traditional feed train can minimize feed temperature variations during periods of low turbine demand, reducing the effects of thermal cycling and increasing overall thermodynamic efficiency. This paper discusses the design, operation and control strategies for an auxiliary feed water system as an integral component of a coupled Thermal Energy Storage system and Integral Pressurized Water Reactor. The impact on system performance, particularly as it affects reactor dynamic response and reductions in thermal cycling will be addressed. In addition to the improved thermal efficiency, a benefit of this approach is the relocation of thermal stressors from the reactor coolant system to more easily managed Balance of Plant systems

22 GENERAL STUDIES OF NUCLEAR REACTORS↗