Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Monte Carlo Second- and Third-Order Many-Body Green’s Function Methods with Frequency-Dependent, Nondiagonal Self-Energy

We fully develop the Monte Carlo many-body Green’s function (MC-GF) method with the following enhancements: (1) The truncation order of the perturbation expansion of the Dyson self-energy is raised from the second order (MC-GF2) to the third order (MC-GF3) with the aid of a computerized procedure to enumerate and transform all 84 third-order Goldstone diagrams into Monte Carlo integrable expressions and then into central processing unit (CPU)/graphical processing unit (GPU)-parallel computer codes. (2) An efficient algorithm is proposed that computes all off-diagonal and diagonal elements of the MC-GF2 and MC-GF3 self-energy matrices by common subexpression elimination. (3) The frequency-independent approximation is lifted by introducing a method that computes frequency derivatives of the MC-GF2 and MC-GF3 self-energies up to any arbitrarily high order at nearly no additional computational cost. (4) The imaginary-time integration in the Laplace-transformed expressions of the self-energy is carried out stochastically (instead of using a quadrature in the previous implementations), resulting in a 50- to 200-fold speedup. (5) The efficiency of the redundant-walker convergence acceleration scheme is analyzed numerically, and the guidelines are established to select an optimal number of walkers for maximal efficiency. When such an optimal number is used, the cost per sample is constant of molecular size on either many CPUs or many GPUs. (6) The computational cost to obtain a binding energy within a given statistical uncertainty is observed to increase as (tentatively) O(n 4 ) and O(n 5 ) of molecular size (n is the number of electrons) with and without the diagonal approximation, respectively, as opposed to O(n 5 ) and O(n 6 ) of the corresponding deterministic algorithms. With this method applied to the electron binding energies of C 60 , we show that the third-order corrections to the self-energies are much greater in electron binding energies than in ground-state energies. As a result, they display a sign of oscillatory convergence toward experimental results, not necessarily improving the agreement with increasing perturbation order, justifying MC-GF3 and motivating even higher-order methods.

Algorithms↗

Magnetized retarding field energy analyzer measuring the particle flux and ion energy distribution of both positive and negative ions

This paper presents the development of a magnetized retarding field energy analyzer (MRFEA) used for positive and negative ion analysis. The two-stage analyzer combines a magnetic electron barrier and an electrostatic ion energy barrier allowing both positive and negative ions to be analyzed without the influence of electrons (co-extracted or created downstream). An optimal design of the MRFEA for ion-ion beams has been achieved by a comparative study of three different MRFEA configurations, and from this, scaling laws of an optimal magnetic field strength and topology have been deduced. The optimal design consists of a uniform magnetic field barrier created in a rectangular channel and an electrostatic barrier consisting of a single grid and a collector placed behind the magnetic field. The magnetic barrier alone provides an electron suppression ratio inside the analyzer of up to 6000, while keeping the ion energy resolution below 5 eV. The effective ion transparency combining the magnetic and electrostatic sections of the MRFEA is measured as a function of the ion energy. It is found that the ion transparency of the magnetic barrier increases almost linearly with increasing ion energy in the low-energy range (below 200 eV) and saturates at high ion energies. The ion transparency of the electrostatic section is almost constant and close to the optical transparency of the entrance grid. We show here that the MRFEA can provide both accurate ion flux and ion energy distribution measurements in various experimental setups with ion beams or plasmas run at low pressure and with ion energies above 10 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy savings modelling of re-tuning energy conservation measures in large office buildings

Today, many large commercial buildings use sophisticated building automation systems (BASs) to manage a wide range of building equipment. While the capabilities of BASs have increased over time, many buildings still do not fully use the BAS’s capabilities and are not properly commissioned, operated or maintained, which leads to inefficient operation, increased energy use, and reduced lifetimes of the equipment. This paper investigates the energy savings potential of several common HVAC system re-tuning measures on a typical large office building, using the Department of Energy’s building energy modeling software, EnergyPlus. The baseline prototype model uses roughly as much energy as an average large office building in existing building stock, but does not utilize any re-tuning measures. Individual re-tuning measures simulated against this baseline include automatic schedule adjustments, damper minimum flow adjustments, thermostat adjustments, as well as dynamic resets (set points that change continuously with building and/or outdoor conditions) to static pressure, supply-air temperature, condenser water temperature, chilled and hot water temperature, and chilled and hot water differential pressure set points. Six combinations of these individual measures have been formulated – each designed to conform to limitations to implementation of certain individual measures that might exist in typical buildings. All the individual measures and combinations were simulated in 16 climate locations representative of specific U.S. climate zones. The modeling results suggest that the most effective energy savings measures are those that affect the demand-side of the building (air-systems and schedules). Many of the demand-side individual measures were capable of reducing annual total HVAC system energy consumption by over 20% in most cities that were modeled. Supply side measures affecting HVAC plant conditions were only modestly successful (less than 5% annual HVAC energy savings for most cities for all measures). Combining many of the re-tuning measures revealed deep savings potential. Some of the more aggressive combinations revealed 35-75% reductions in annual HVAC energy consumption, depending on climate and building vintage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accelerating Ocean-Based Renewable Energy Educational Opportunities to Achieve a Clean Energy Future

The United Nations has named 2021–2030 the Decade of Ocean Science for Sustainable Development with goals to 'strengthen the international cooperation needed to develop the scientific research and innovative technologies that can connect ocean science with the needs of society' (IOC 2019 The science we need for the ocean we want: the United Nations decade of ocean science for sustainable development (2021–2030) (Paris) p 24). Important actions that have been identified in support of sustainable development goals include capacity-building, training, and education. This includes educational opportunities for ocean-based renewable energy development in support of a healthy planet and ocean. Offshore wind is experiencing rapid development globally and, while the U.S. offshore wind market is still nascent, it is on the brink of exponential growth based on large cost reductions driven largely by European development and technology advances. Growth is also expected in wave and tidal energy with significant opportunities identified for various distributed markets through the Powering the Blue Economy™ initiative, with longer-term implications for expansion at the utility scale (LiVecchi et al 2019 Powering the blue economy; exploring opportunities for marine renewable energy in maritime markets p 207). In order to expedite progress and maximize benefits to the national, state, and local economies, these development actions will require a broad, diverse, and appropriately trained workforce. The ocean-based renewable energy workforce needs engineers and scientists to develop cost-effective technologies, as well as trade and maritime workers to eventually deploy the technologies at scale. In the United States, educational institutions, state governments, and private developers are taking action to understand job skills and capability requirements and to develop educational and training programs to meet offshore workforce needs; most are focused on offshore wind power, with gaining interest in marine energy. This article explores the workforce requirements of the growing ocean-based renewable energy industry and the current state of education and training programs to meet those requirements in order to identify gaps and make recommendations for further workforce development activities and initiatives. An international view needs to be adopted that incorporates the education and skill needs of early-stage marine energy technologies and evolving offshore wind technologies together with more market-ready offshore renewable energy markets. By accelerating educational development opportunities in ocean-based renewable energy, these growing blue economy markets can deliver significant economic and social benefits.

50 EE - Wind and Water Power Program - Water (EE-4↗

Limits on dark radiation, early dark energy, and relativistic degrees of freedom

Recent cosmological data analyses hint at the presence of an extra relativistic energy component in the early universe. This component is often parametrized as an excess of the effective neutrino number N{sub eff} over the standard value of 3.046. The excess relativistic energy could be an indication for an extra (sterile) neutrino, but early dark energy and barotropic dark energy also contribute to the relativistic degrees of freedom. We examine the capabilities of current and future data to constrain and discriminate between these explanations, and to detect the early dark energy density associated with them. We find that while early dark energy does not alter the current constraints on N{sub eff}, a dark radiation component, such as that provided by barotropic dark energy models, can substantially change current constraints on N{sub eff}, bringing its value back to agreement with the theoretical prediction. Both dark energy models also have implications for the primordial mass fraction of Helium Y{sub p} and the scalar perturbation index n{sub s}. The ongoing Planck satellite mission will be able to further discriminate between sterile neutrinos and early dark energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy-range relation and mean energy variation in therapeutic particle beams

Analytical expressions for the mean energy and range of therapeutic light ion beams and low- and high-energy electrons have been derived, based on the energy dependence of their respective stopping powers. The new mean energy and range relations are power-law expressions relevant for light ion radiation therapy, and are based on measured practical ranges or known tabulated stopping powers and ranges for the relevant incident particle energies. A practical extrapolated range, R{sub p}, for light ions was defined, similar to that of electrons, which is very closely related to the extrapolated range of the primary ions. A universal energy-range relation for light ions and electrons that is valid for all material mixtures and compounds has been developed. The new relation can be expressed in terms of the range for protons and alpha particles, and is found to agree closely with experimental data in low atomic number media and when the difference in the mean ionization energy is low. The variation of the mean energy with depth and the new energy-range relation are useful for accurate stopping power and mass scattering power calculations, as well as for general particle transport and dosimetry applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The energy dependence of lithium formate and alanine EPR dosimeters for medium energy x rays

Purpose: To perform a systematic investigation of the energy dependence of alanine and lilthium formate EPR dosimeters for medium energy x rays. Methods: Lithium formate and alanine EPR dosimeters were exposed to eight different x-ray beam qualities, with nominal potentials ranging from 50 to 200 kV. Following ionometry based on standards of absorbed dose to water, the dosimeters were given two different doses of approximately 3 and 6 Gy for each radiation quality, with three dosimeters for each dose. A reference series was also irradiated to three different dose levels at a {sup 60}Co unit. The dose to water energy response, that is, the dosimeter reading per absorbed dose to water relative to that for {sup 60}Co {gamma}-rays, was estimated for each beam quality. In addition, the energy response was calculated by Monte Carlo simulations and compared to the experimental energy response. Results: The experimental energy response estimates ranged from 0.89 to 0.94 and from 0.68 to 0.90 for lithium formate and alanine, respectively. The uncertainties in the experimental energy response estimates were typically 3%. The relative effectiveness, that is, the ratio of the experimental energy response to that following Monte Carlo simulations was, on average, 0.96 and 0.94 for lithium formate and alanine, respectively. Conclusions: This work shows that lithium formate dosimeters are less dependent on x-ray energy than alanine. Furthermore, as the relative effectiveness for both lithium formate and alanine were systematically less than unity, the yield of radiation-induced radicals is decreased following x-irradiation compared to irradiation with {sup 60}Co {gamma}-rays.

60 APPLIED LIFE SCIENCES↗

The CUNY Energy Institute Electrical Energy Storage Development for Grid Applications (Final report)

1. Project Objectives: The objectives of the project are to elucidate science issues intrinsic to high energy density electricity storage (battery) systems for smart-grid applications, research improvements in such systems to enable scale-up to grid-scale and demonstrate a large 200 kWh battery to facilitate transfer of the technology to industry. 2. Background: Complex and difficult to control interfacial phenomena are intrinsic to high energy density electrical energy storage systems, since they are typically operated far from equilibrium. One example of such phenomena is the formation of dendrites. Such dendrites occur on battery electrodes as they cycle, and can lead to internal short circuits, reducing cycle life. An improved understanding of the formation of dendrites and their control can improve the cycle life and safety of many energy storage systems, including rechargeable lithium and zinc batteries. Another area where improved understanding is desirable is the application of ionic liquids as electrolytes in energy storage systems. An ionic liquid is typically thought of as a material that is fully ionized (consisting only of anions and cations) and is fluid at or near room temperature. Some features of ionic liquids include a generally high thermal stability (up to 450°C), a high electrochemical window (up to 6 V) and relatively high intrinsic conductivities. Such features make them attractive as battery or capacitor electrolytes, and may enable batteries which are safer (due to the good thermal stability) and of much higher energy density (due to the higher voltage electrode materials which may be employed) than state of the art secondary (rechargeable) batteries. Of particular interest is the use of such liquids as electrolytes in metal air batteries, where energy densities on the order of 1-2,000 Wh/kg are possible; this is 5-10 times that of existing state of the art lithium battery technology. The Energy Institute has been engaged in the development of flow-assisted nickel zinc battery technology. This technology has the promise of enabling low-cost (<$250/kWh) energy storage, while overcoming the historical poor cycle-life drawback. To date, the results have been promising, with a cycle life of 1,500 cycles demonstrated in small laboratory cells – an improvement of approximately 400%. Prior state of the art nickel zinc batteries have only demonstrated about 400 cycles to failure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Prototype Courthouse Building Energy Model: Building Characteristics and Energy Simulation Results

To coordinate commercial building energy research activities, the US Department of Energy uses a suite of commercial prototype building models, which includes 16 building types and covers 80% of US commercial floorspace. Efforts are underway to expand this suite by developing prototype models for additional building types, including a courthouse. Informed by building design guides, databases, documented projects, and personal communication with courthouse design experts, a 3-story, 4-courtroom, 69,324 ft 2 building was considered as the prototype courthouse to represent an average-sized courthouse in the United States. This report documents the building and system characteristics of the prototype courthouse model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. To verify the energy simulation results, energy use statistics of existing courthouses from different building database are also presented. Based on the simulated energy use, the site energy use intensity of the prototype courthouse ranged from 45 to 159 kBtu/ft 2 compared with the average energy use intensity of 94.7 kBtu/ft 2 for the courthouse building type in the 2012 Commercial Building Energy Consumption Survey (CBECS) Data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decarbonization of Residential Building Energy Supply: Impact of Cogeneration System Performance on Energy, Environment, and Economics

Electrical and thermal loads of residential buildings present a unique opportunity for onsite power generation, and concomitant thermal energy generation, storage, and utilization, to decrease primary energy consumption and carbon dioxide intensity. This approach also improves resiliency and ability to address peak load burden effectively. Demand response programs and grid-interactive buildings are also essential to meet the energy needs of the 21st century while addressing climate impact. Given the significance of the scale of building energy consumption, this study investigates how cogeneration systems influence the primary energy consumption and carbon footprint in residential buildings. The impact of onsite power generation capacity, its electrical and thermal efficiency, and its cost, on total primary energy consumption, equivalent carbon dioxide emissions, operating expenditure, and, most importantly, thermal and electrical energy balance, is presented. The conditions at which a cogeneration approach loses its advantage as an energy efficient residential resource are identified as a function of electrical grid’s carbon footprint and primary energy efficiency. Compared to a heat pump heating system with a coefficient of performance (COP) of three, a 0.5 kW cogeneration system with 40% electrical efficiency is shown to lose its environmental benefit if the electrical grid’s carbon dioxide intensity falls below 0.4 kg CO 2 per kWh electricity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2012 ARPA-E Energy Innovation Summit Keynote Presentation (Secretary of Energy Steven Chu)

The third annual ARPA-E Energy Innovation Summit was held in Washington D.C. in February, 2012. The event brought together key players from across the energy ecosystem - researchers, entrepreneurs, investors, corporate executives, and government officials - to share ideas for developing and deploying the next generation of energy technologies. Dr. Steven Chu, Energy Secretary, gave the first keynote presentation of the day. He discusses how President Obama's all-of-the-above approach to energy will help the Unites States solve 21st century global energy challenges and maintain its leadership as an exporter of energy technology. Secretary of Energy Steven Chu highlighted our vulnerability to price fluctuations in the fuel markets, most recently to oil and gasoline, as well as our inability to drill our way out of the problem. Secretary Chu made the case for leveraging energy innovation in order to reduce our exposure to oil price fluctuations and improve the U.S.'s economic competitiveness.

02 PETROLEUM↗

Building envelope advancement under the US-China Clean Energy Research Center for building energy efficiency

The US–China Clean Energy Research Center (CERC) was launched in 2009 by U.S. Energy Secretary Steven Chu, Chinese Minister of Science and Technology Wan Gang, and Chinese National Energy Agency Administrator Zhang Guobao. 1 This five-year collaboration emerged from the fact that the U nited States and China are the world’s largest energy producers, energy consumers , and greenhouse gas emitters 2 (Figure 1) , and that their joint effort could have positive repercussions worldwide. CERC’s main goal is to develop and deploy clean energy technologies that will help both countries meet energy and climate challenges. Three consortia were established to address the most pressing energy-related research areas: Advanced Coal Technology, Clean Vehicles, and Building Energy Efficiency (BEE).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Frontier Research Centers: Science For Our Nation’s Energy Future (July 2019)

As world demand for energy rapidly expands, transforming the way energy is collected, stored, and used has become a defining challenge of the 21st century. At its heart, this challenge is a scientific one, inspiring the U.S. Department of Energy’s (DOE) Office of Basic Energy Sciences (BES) to establish the Energy Frontier Research Center (EFRC) program in 2009. The EFRCs represent a unique approach, bringing together creative, multidisciplinary scientific teams to perform energy-relevant basic research with a complexity beyond the scope of single-investigator projects. These centers take full advantage of powerful new tools for characterizing, understanding, modeling, and manipulating matter from atomic to macroscopic length scales. They also train the next-generation scientific workforce by attracting talented students and postdoctoral researchers interested in energy science. To date, BES has supported 82 EFRCs, of which 46 are currently active, involving more than 1,600 senior investigators and at least 5,400 students and postdoctoral researchers at over 170 institutions. The EFRCs have collectively demonstrated the potential to substantially advance the scientific understanding underpinning transformational energy technologies. Both a BES Committee of Visitors and a Secretary of Energy Advisory Board Task Force have found the EFRC program to be highly successful in meeting its goals. The scientific output from the EFRCs is impressive, and many centers have reported that their results are already impacting both technology research and industry. This report on the EFRC program includes selected highlights from 2016-2019.

99 GENERAL AND MISCELLANEOUS↗

Energy storage in combined gas-electric energy transitions models: The case of California

California’s vision for a net-zero future by 2045 relies heavily on variable renewable energy systems. Thus, energy storage - particularly long-duration storage - could play a fundamental role in reliably supplying low-carbon electricity. We study energy storage using the BRIDGES model, a combined gas-electric capacity expansion model for California across multiple investment periods (2025-2045), modeled with progressively decreasing carbon emission targets to a zero emissions by 2045. This least-cost optimization model includes renewable gas production via power-to-gas, long-term storage of energy in gaseous form, electric energy storage such as through batteries and hydrogen storage, and renewable energy generation, all with capacity tracking and investment. Multiple scenarios are evaluated to examine the sensitivity of the optimal storage portfolio to system-level and sector-level parameters. The scenario results show that all electric energy storage systems - which vary in storage duration - are deployed and required in a net-zero California in 2045, amounting to around 75 GW of storage capacity. Lithium ion systems make up approximately 80% of this power capacity and supply most short-run storage needs. Hydrogen storage - in the form of a power-to-gas-to-power system - emerges as a replacement to conventional natural gas storage, comprising most of the total energy storage capacity (~ 4 TWh). This capacity is less than 5% of the current natural gas storage capacity (94 TWh), indicating sufficient room for repurposing part of the gas infrastructure. A demand-side sensitivity analysis proves that higher electricity demand correlates with more builds of Li-ion batteries, while higher industrial heat demand leads to more builds of long-duration storage systems in a net-zero economy. Furthermore, power-to-gas systems satisfy part of the industrial heat demand by locally supplying renewable gas, which overtakes the traditional centralized gas storage and transfers through pipelines, casting significant doubts on the future of the large-scale gas infrastructure.

03 NATURAL GAS↗

AI-Based Analytics and Energy Modeling Framework for Characterizing Urban Energy Systems

Developing location-specific district energy models is essential for understanding energy patterns and supporting efficient management and planning decisions. However, accurately characterizing these models remains challenging due to gaps in building characteristics and labor-intensive traditional modeling workflows. To address these challenges, we develop an AI-based framework that integrates top-down and bottom-up building energy data to automate urban energy model characterization. The framework trains multimodal deep learning models using heterogeneous ResStockTM datasets to infer missing building characteristics from varying levels of known information and generate simulation-ready inputs for district-scale energy modeling. It also employs a conditioning-based injection approach to generate ”what-if” scenarios, enabling users to explore retrofit, efficiency, and technology-upgrade pathways. Integrated within URBANoptTM, a bottom-up district energy modeling platform for simulating co-located buildings, the framework infers detailed building-level inputs required for bottom-up simulations. Both localized and generalized AI models are developed to learn relationships across categorical, numerical, and time-series data, enabling reconstruction of missing attributes and generation of targeted upgrade scenarios. We demonstrate this methodology on a residential neighborhood in Baltimore, MD, assessing internal consistency against ResStock reference data and URBANopt simulation, and comparing selected attributes against real-world building characteristics. Results show strong overall predictive accuracy in data completion and scenario generation, with localized and generalized models offering complementary trade-offs between precision and scalability. Overall, our automated framework streamlines energy modeling and provides a reliable framework for urban building energy characterization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electronic Energies Are Not Enough: An Ion Mobility-Aided, Quantum Chemical Benchmark Analysis of H + GPGG Conformers

Peptides and proteins exist not as single, lowest energy structures but as ensembles of states separated by small barriers. In order to study these species we must be able to correctly identify their gas phase conformational distributions, and ion mobility spectrometry (IMS) has arisen as an experimental method for assessing the gas phase energetics of flexible peptides. Here, we present a thorough exploration and benchmarking of the low energy conformers of the small, hairpin peptide H+ GPGG with the aid of ion mobility spectrometry against a wide swath of density functionals (35 dispersion-corrected and uncorrected functionals represented by 21 unique exchange–correlation functionals) and wave function theory methods (15 total levels of theory). The three experimentally resolved IMS peaks were found to correspond to three distinct pairs of conformers, each pair composed of species differing only by the chair or boat configuration of the proline. Two of the H+ GPGG conformer pairs possess a cis configuration about the Pro–Gly1 peptide bond while the other adopts a trans configuration. While the experimental spectrum reports a higher intensity for the cis-1 conformer than the trans conformer, 13 WFT levels of theory, including a complete basis set CCSD(T) extrapolation, obtain trans to be favored in terms of the electronic energy. This same effect is seen in 14 of the 18 dispersion-corrected density functionals studied, whereas the remaining 17 functionals show more variety. Only when Gibbs free energies are considered do the WFT methods and dispersion-corrected functionals reflect the experimental distribution. CAM-B3LYP-D3BJ emerges as the best-performing density functional, matching the experimental distribution and the CCSD(T)/CBS relative energies within 6%. Further analysis reveals the trans conformer to be favored electronically, but entropically disfavored, leading to the experimental preference of the cis-1 conformer. Furthermore, these results highlight the danger in considering only the electronic energies, which is common practice in electronic structure theory predictions of conformational energy distributions. Additionally, the effects of temperature and scaling of the frequencies used in obtaining the Gibbs free energies are explored.

Energy↗