Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electromagnetic Radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Excessive charge, beam loading, and impedance collapse thresholds for a velvet emitter

Excess emission has been observed from velvet cathodes with total emission times >150 ns. In this diode experiment, we produce a sub-relativistic electron beam with the ability to consistently change γ from 1.2 to 1.5 and β = 0.5–0.75. Electron emission in this particular diode geometry requires electric fields >40 kV/cm. The current increases at steady rates >0.05 A/ns after the head of the pulse, indicating an expansion of the emission surface and reduction in the effective AK gap. Small transients of excess emission (or arcs) are consistently observed for current pulses exceeding 150 ns. The excess emission results in beam loaded levels ≥10 kV on the diode voltage. The effects described here are compounded as diode voltage is increased. The principal objective of these experiments is to quantify electric field emission thresholds, current ramps, excess emission delays, effective beam loading, and impedance collapse.

43 PARTICLE ACCELERATORS↗

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION↗

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION↗

Absolute magneto-optical measurement of magnetic field on a long pulse high electrical current driven solenoid

We describe a direct absolute magneto-optical approach to measuring the magnetic field driven by long pulse width (>5 ms) and high electrical current (∼kA) in a solenoidal coil. The magnetic field and electrical current are among the most important operating parameters in lightning research and electrical power distribution and are essential to understanding the properties of the radiation output in pulsed energy accelerators as well as other research platforms. However, accurately measuring these magnetic fields and electrical currents using conventional electrical diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element material sensing crystal that is highly resistant to electromagnetic interference, allows for absolute measurement, and does not require an external calibration. Here, we focus on device theory, operating parameters, magneto-optical results from an experiment on a high current solenoid, and comparison with a calculation of the magnetic field and reference electrical current flowing downstream of the solenoid.

Owens, Israel [Sandia National Laboratories (SNL-N↗

Development and characterization of a laser-gated, high resolution x-ray radiography platform for high energy density experiments using toroidally bent crystals

Bent crystal x-ray imagers are a well-established diagnostic tool to study high energy density (HED) objects by acquiring two-dimensional x-ray radiographs. Often, studying these HED objects requires very high spatial resolution, which is limited by astigmatism when using spherically bent crystals. By using toroidal-shaped crystals instead, astigmatism can be reduced and the overall spatial resolution of the instrument improved. Here, the development and characterization of a laser-gated x-ray radiography platform at the National Ignition Facility using a toroidal crystal is presented. This includes measurements of the spatial and temporal profile, which is determined by the x-ray source. In conclusion, to properly validate the reduced astigmatism, a new multi-plane grid approach was implemented, which, for the first time, allows a depth of field measurement, alignment verification and x-ray source size estimate in a single shot, demonstrating the current platform’s capability to provide sub-10 μm resolution over a 0.9 mm depth of field with a temporal resolution of 110 ps.

Crystal optics↗

Calibration of a broadband x-ray crystal spectrometer using a continuum x-ray source and photon-counting detectors

We report measurements of sensitivity of a broadband (≃20–30 keV) x-ray crystal spectrometer using a bremsstrahlung continuum x-ray source and several detectors, including an energy-discriminating photon-counting point detector (Si drift diode, Amptek Inc.), imaging hybrid photon-counting detectors (Eiger2-Si and Eiger2-CdTe, DECTRIS Ltd.), and image plates (SR type). Sensitivity is defined as a ratio of the crystal-reflected energy-position-dispersed spectrum measured by a given detector to the incident non-dispersed spectrum measured using the energy-discriminating point detector. The sensitivity derived from data measured exclusively by the point detector is considered detector-independent and serves as a reference. The sensitivities derived from data collected with the hybrid photon-counting detectors were matched to the reference using a scale factor of 1.05. The image plate-derived sensitivities required a scale factor of 1.16 to match the reference. Furthermore, the resulting mismatch in the shapes of all measured scaled sensitivities in the range of the spectrometer was ≲±10%, while the mismatch between the shapes of the sensitivities corresponding to the Si-based detectors was ≲±2.5%.

Crystal optics↗

Measurement of near- and far-field impurity flows during pellet-induced rapid shutdown in DIII-D

Both near-field (<1 m away toroidally from the pellet) and far-field (>1 m away toroidally from the pellet) poloidal and toroidal impurity (carbon ion) flows are measured using visible imaging and fast bolometry during a polypropylene pellet-induced rapid plasma shutdown in the DIII-D tokamak. In the near field, the pellet appears to increase poloidal flow in the ion diamagnetic direction, possibly due to the strong radial temperature gradient caused by the pellet ablation. In the far field, the poloidal impurity flow typically appears slower and in the opposite direction. Toroidal impurity flow appears to be strongly influenced by the plasma initial toroidal rotation, especially in the far field. These results demonstrate that rapid shutdown impurity flows are not necessarily global in structure but can be quite different close to and far from the injected pellet.

Electromagnetic radiation detectors↗

Demonstration of a 1820 channel multiplexer for transition-edge sensor bolometers

The scalability of most transition-edge sensor arrays is limited by the multiplexing technology, which combines their signals over a reduced number of wires and amplifiers. Here, in this Letter, we present and demonstrate a multiplexer design optimized for transition-edge sensor bolometers with 1820 sensors per readout unit, a factor of two more than the previous state-of-the-art. The design is optimized for cosmic microwave background imaging applications, and it builds on previous microwave superconducting quantum interference device multiplexers by doubling the available readout bandwidth to the full 4–8 GHz octave. Evaluating the key performance metrics of yield, sensitivity, and crosstalk through laboratory testing, we find an end-to-end operable detector yield of 78%, a typical nearest-neighbor crosstalk amplitude of ∼0.4%, and a median white noise level of 83 pA/$\sqrt{\textrm{Hz}}$ due to the multiplexer, corresponding to an estimated contribution of 4% to the total system noise for a ground-based cosmic microwave background telescope. Additionally, we identify a possible path toward reducing resonator loss for future designs with reduced noise. We expect these developments to alleviate the system complexity, cryogenic requirements, and cost of future large arrays of low temperature detectors.

cosmic microwave background↗

Localised electromagnetic waves in a rhombic waveguide array with competing nonlinearities

We consider a model of a discrete photonic system representing a quasi-one-dimensional rhombic array of waveguides, where, in addition to the positive cubic nonlinearity, the negative quintic nonlinearity is taken into account for the material of which the central chain of the waveguides is made. The other two waveguide chains are made of an optically linear material. A continual approximation is used to obtain a solution for a system of coupled waves, which describes a wave localised in the transverse direction. In a certain special case, the competition of nonlinearities leads to the formation of a step-shaped distribution of the field intensities over the waveguides. (integrated optics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reversible plasmonic switching in a graphene nanoresonator loaded with a core – shell quantum dot

A model of an all-plasmonic switch based on a graphene waveguide integrated with a stub nanoresonator loaded with a quantum dot is considered. Using the full-wave numerical simulation, it is shown that successive on/off switching of the control surface plasmon – polariton wave at the input of the waveguide leads to a change in the phase of the signal plasmon – polariton wave in the nanoresonator by π. This causes reversible switching of the device operation regime – from almost complete blocking to stable transmission of the signal plasmon – polariton wave through the waveguide. The effect is implemented at rates of ∼0.5 THz for infrared electromagnetic waves localised in a device with a switching region of 40 × 20 nm. (paper)

36 MATERIALS SCIENCE↗

Nonlocal effects from boosted dark matter in indirect detection

Here, indirect dark matter (DM) detection typically involves the observation of standard model (SM) particles emerging from DM annihilation/decay inside regions of high dark matter concentration. We consider an annihilation scenario in which this reaction has to be initiated by one of the DMs involved being boosted while the other is an ambient nonrelativistic particle. This “trigger” DM must be created, for example, in a previous annihilation or decay of a heavier component of DM. Remarkably, boosted DM annihilating into gamma rays at a specific point in a galaxy could actually have traveled from its source at another point in the same galaxy or even from another galaxy. Such a “nonlocal” behavior leads to a nontrivial dependence of the resulting photon signal on the galactic halo parameters, such as DM density and core size, encoded in the so-called “astrophysical” J-factor. These nonlocal J-factors are strikingly different than the usual scenario. A distinctive aspect of this model is that the signal from dwarf galaxies relative to the Milky Way tends to be suppressed from the typical value to various degrees depending on their characteristics. This feature can thus potentially alleviate the mild tension between the DM annihilation explanation of the observed excess of approximately GeV photons from the Milky Way’s Galactic Center vs the apparent nonobservation of the corresponding signal from dwarf galaxies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Signatures of deconfined quark phases in binary neutron star mergers

We investigate the quark deconfinement phase transition in the context of binary neutron star (BNS) mergers. We employ a new finite-temperature composition-dependent equation of state (EOS) with a first order phase transition between hadrons and deconfined quarks to perform numerical relativity simulations of BNS mergers. Here, the softening of the EOS due to the phase transition causes the merger remnants to be more compact and to collapse to a black hole (BH) at earlier times. The phase transition is imprinted on the postmerger gravitational wave (GW) signal duration, amplitude, and peak frequency. However, this imprint is only detectable for binaries with sufficiently long-lived remnants. Moreover, the phase transition does not result in significant deviations from quasi-universal relations for the postmerger GW peak frequency. We also study the impact of the phase transition on dynamical ejecta, remnant accretion disk masses, r-process nucleosynthetic yields and associated electromagnetic (EM) counterparts. While there are differences in the EM counterparts and nucleosynthesis yields between the purely hadronic models and the models with phase transitions, these can be primarily ascribed to the difference in remnant collapse time between the two. An exception is the non-thermal afterglow caused by the interaction of the fastest component of the dynamical ejecta and the interstellar medium, which is systematically boosted in the binaries with phase transition as a consequence of the more violent merger they experience.

79 ASTRONOMY AND ASTROPHYSICS↗

BICEP/ Keck XVIII: Measurement of BICEP3 polarization angles and consequences for constraining cosmic birefringence and inflation

We use a custom-made calibrator to measure individual detectors’ polarization angles of BICEP3, a small aperture telescope observing the cosmic microwave background (CMB) at 95 GHz from the South Pole. We describe our calibration strategy and the statistical and systematic uncertainties associated with the measurement. We reach an unprecedented precision for such measurement on a CMB experiment, with a repeatability for each detector pair of 0.02°. Here, we show that the relative angles measured using this method are in excellent agreement with those extracted from CMB data. Because the absolute measurement is currently limited by a systematic uncertainty, we do not derive cosmic birefringence constraints from BICEP3 data in this work. Rather, we forecast the sensitivity of BICEP3 sky maps for such analysis. We investigate the relative contributions of instrument noise, lensing, and dust, as well as astrophysical and instrumental systematics. We also explore the constraining power of different angle estimators, depending on analysis choices. We establish that the BICEP3 2-year dataset (2017–2018) has an on-sky sensitivity to the cosmic birefringence angle of 𝜎 𝛼 = 0.07⁢8°, which could be improved to 𝜎 𝛼 = 0.05⁢5° by adding all of the existing BICEP3 data (through 2023). Furthermore, we emphasize the possibility of using the BICEP3 sky patch as a polarization calibration source for CMB experiments, which with the present data could reach a precision of 0.035°. Finally, in the context of inflation searches, we investigate the impact of detector-to-detector variations in polarization angles as they may bias the tensor-to-scalar ratio 𝑟. We show that while the effect is expected to remain subdominant to other sources of systematic uncertainty, it can be reliably calibrated using polarization angle measurements such as the ones we present in this paper.

Cosmic microwave background↗

Constraints on Lorentz Invariance Violation from HAWC Observations of Gamma Rays above 100 TeV

Because of the high energies and long distances to the sources, astrophysical observations provide a unique opportunity to test possible signatures of Lorentz invariance violation (LIV). Superluminal LIV enables the decay of photons at high energy. The high altitude water Cherenkov (HAWC) observatory is among the most sensitive gamma-ray instruments currently operating above 10 TeV. HAWC finds evidence of 100 TeV photon emission from at least four astrophysical sources. These observations exclude, for the strongest of the limits set, the LIV energy scale to 2.2 × 10 31 eV , over 1800 times the Planck energy and an improvement of 1 to 2 orders of magnitude over previous limits.

79 ASTRONOMY AND ASTROPHYSICS↗

New Probe of Cosmic Birefringence Using Galaxy Polarization and Shapes

We propose a novel statistical method to measure cosmic birefringence and demonstrate its power in probing parity violation due to axions. Exploiting an empirical correlation between the integrated radio polarization direction of a spiral galaxy and its apparent shape, we devise an unbiased minimum-variance estimator for the rotation angle, which should achieve an uncertainty of 5°–15° per galaxy. In conclusion, large galaxy samples from the forthcoming SKA continuum surveys, together with optical shape catalogs, promise a comparable or even lower noise power spectrum for the rotation angle than in the CMB Stage-IV (CMB-S4) experiment, with different systematics.

Axion-like particles↗