Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrolyzers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Method—Using Microelectrodes to Explore Solid Polymer Electrolytes

Solid polymer electrolytes are an emerging technology in electrochemistry driven by their use in energy applications such as fuel cells, electrolyzers, and solid-state batteries. Compared to traditional liquid electrolytes, solid polymer electrolytes provide safer, cheaper, and potentially improved device performance. However, there is a lack of standard experimental methods for studying solid electrolytes. Microelectrodes have inherent benefits capable of filling this experimental gap due primarily to their integration into model electrochemical cells with solid electrolytes that represent complex interfaces, enabling additional insight into reaction processes. In this tutorial review, we explore the use of microelectrodes to study solid polymer electrolytes, beginning with a brief history of the field including common experimental cell designs and their benefits and drawbacks. Methods of evaluating essential kinetic and mass-transport parameters are then examined. In addition, the key studies of the past 30 years utilizing microelectrode cells and solid polymer electrolytes are summarized, with important results highlighted and compared. Finally, future studies of solid polymer electrolytes with microelectrodes and potential new avenues of research are commented on.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method—Practices and Pitfalls in Voltage Breakdown Analysis of Electrochemical Energy-Conversion Systems

Many electrochemical energy-conversion systems are evaluated by polarization curves, which report the cell voltage across a range of current densities and are a global measure of operation and state of health. Mathematical models can be used to deconstruct the measured overall voltage and identify and quantify the voltage-loss sources, such as kinetic, ohmic, and mass-transport effects. These results elucidate the best pathways for improved performance. In this work, we discuss several voltage-breakdown methods and provide examples across different low-temperature, membrane-based electrochemical systems including electrolyzers, fuel cells, and related electrochemical energy-conversion devices. We present best practices to guide experimentalists and theorists in polarization-curve breakdown analysis.

30 DIRECT ENERGY CONVERSION↗

Resolving Anodic Current and Temperature Distributions in a Polymer Electrolyte Membrane Water Electrolysis Cell Using a Pseudo-Two-Phase Computational Fluid Dynamics Model

Expanding upon our prior experimental work, we constructed a three-dimensional model of a polymer electrolyte membrane water electrolyzer using computational fluid dynamics. We applied the assumption of pseudo-two-phase flow, the flow of two phases with equal velocity. Experimental data were used to obtain parameters and to determine the conditions under which this model was valid. Anodic distributions of current density, temperature, liquid saturation, and relative humidity were obtained at various flow rates. The overall current density and temperature difference from inlet to outlet at the anode agreed strongly with experimental measurements under most circumstances. This verification allowed us to further examine the apparent gas coverage calculated from experimental and model temperature data. Results suggested a low liquid saturation and low relative humidity at the anode due to the consumption of liquid water and water vapor. However, we questioned the accuracy of the pseudo-two-phase assumption at low water feed rates. We concluded that the model was applicable to systems with liquid water feed rates greater than 0.6 ml min -1 cm -2 . Therefore, it is a fair screening method that can advise which operating conditions lead to excessive temperatures or drying at the anode, thereby promoting the longevity of the membrane and catalyst.

25 ENERGY STORAGE↗

Intermediate-Temperature Proton Exchange Membranes Based on Cerium Ultraphosphate Composited with Polybenzimidazole

This paper reports the rational fabrication and structural, thermal, mechanical and electrochemical characterization of a new type of intermediate-temperature (IT) polymer-inorganic composite (PIC) proton exchange membranes (PEMs) that are made of cerium ultraphosphate (CeP 5 O 14 —CUP) as the solid-state proton conductor composited with a high-temperature (HT) polybenzimidazole (PBI) as the polymeric binder. Here, flexible PBI-CUP PIC membranes with the thickness of ~135 μ m and CUP mass fraction of up to 75% were prepared by solution-casting without additional acid-doping (e.g., phosphoric acid). The proton conductivity of the fabricated IT-PIC-PEMs was up to 5.80 × 10 –2 S cm –1 as measured from a prototype IT PEM fuel cell (PEMFC) operated at 200 °C in the humidified hydrogen and air environment. This type of IT-PIC-PEMs also demonstrated sufficient mechanical strength and flexibility, excellent thermal stability (up to 350 °C), and very good durability of the proton conductivity (within the test duration of 500 h). The present experimental study shows the promising future of the IT-PIC-PEMs for applications in various IT electrochemical processes including IT-PEMFCs, IT-electrolyzers, etc.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance Losses and Current-Driven Recovery from Cation Contaminants in PEM Water Electrolysis

Water contaminants are a common cause of failure for polymer electrolyte membrane (PEM) electrolyzers in the field as well as a confounding factor in research on cell performance and durability. In this study, we investigated the performance impacts of feed water containing representative tap water cations at concentrations ranging from 0.5–500 μ M, with conductivities spanning from ASTM Type II to tap-water levels. We present multiple diagnostic signatures to help identify the presence of contaminants in PEM electrolysis cells. Through analysis of polarization curves and impedance spectroscopy to understand the origins of performance losses, we found that a switch from the acidic to alkaline hydrogen evolution mechanism is a key factor in contaminated cell behavior. Finally, we demonstrated that this mechanism switching can be harnessed to remove cation contaminants and recover cell performance without the use of an acid wash. We demonstrated near-complete recovery of cells contaminated with sodium and calcium, and partial recovery of a cell contaminated with iron, which was further investigated by post-mortem microscopy. The improved understanding of contaminant impacts from this work can inform development of strategies to mitigate or recover performance losses as well as improve the consistency and rigor of electrolysis research.

30 DIRECT ENERGY CONVERSION↗

Mechanistic and Mitigation-Strategy Insights into NaCl and CaCl 2 Contamination of Proton-Exchange-Membrane Water Electrolysis Using Continuum Modeling

Cationic contaminants are detrimental to proton-exchange-membrane water electrolyzers (PEMWEs). To obtain insight, a 1-D, nonisothermal, multiphase continuum cell model including cationic contamination is developed. Simulations of steady-state cell performance predict decreased performance due to an increase in kinetic overpotential associated with the hydrogen-evolution reaction, which was attributed to decreased protonic-activity within the cathode catalyst layer from proton supplantation with contaminant cations. The accumulation and extent of cation exchange in the cathode catalyst layer depends on the operating current density due to migration. Simulations of cell recovery of potential suggest that a contaminated cell can recover approximately 78% (450 mV) with 24 h of constant current density operation at 2 A cm –2 , with higher current densities accelerating reduced recovery times. Parametric studies show that anode-side acidification at lower current densities inhibit cation contaminant adsorption, and cathode-side acidification at larger current densities facilitate the expulsion of adsorbed cations; for a cathode-side pH of 6 and 5, the cell can recover an additional 10% and 100% performance, respectively. Overall, the model serves as a framework for modeling other aspects of PEMWE systems to address durability and performance aspects, which can assist in improving the viability of the technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Editors’ Choice—Molten Salt Electrolysis in Chloride Melts for Energy-Efficient Iron Metal Production

This study explores chloride molten salt electrolysis (CMSE) as a promising route for energy-efficient iron metal (Fe) production. Moderate temperature (500 °C) LiCl-KCl molten salts offer excellent thermodynamic stability, high ionic conductivity and diffusivity, and high solubility for FeCl 3 , thereby enabling efficient Fe metal extraction at high electrowinning rates. Here, we demonstrate the two essential steps for converting taconite ore into Fe metal. First, Fe 2 O 3 from taconite pellets was selectively leached in HCl yielding a high-purity FeCl 3 aqueous solution, while the gangue components settled at the bottom. Then, anhydrous FeCl 3 was electrolyzed in a LiCl-KCl eutectic molten salt at 500 °C at high current density (1 A cm −2 ) and at high Coulombic efficiency (>85%). Analysis of the electrowon Fe deposits revealed dendritic structures with purity of >99 wt%, which could be further improved to nearly 100 wt% through arc re-melting. CMSE offers low specific energy consumption (3.7 kWhr kg −1 ), competitive with H 2 -DRI and other electrolytic approaches being pursued globally. Our findings underscore the potential of CMSE as an energy-efficient route for electrosynthesis of Fe metal.

36 MATERIALS SCIENCE↗

Modeling a High-Temperature Electrochemically Driven Water-Gas-Shift Process Using a Mixed-Conducting Membrane without External Electrical Power

This paper develops a model to predict and interpret the performance of an elevated-temperature, electrochemical, membrane-assisted, water-gas-shift process. The process uses separated feed streams of H 2 O and CO to produce separated streams of H 2 and CO 2 , without an external electrical power source. The dense ceramic membrane is mixed ionic-electronic-conducting (MIEC) gadolinium-doped ceria (GDC) and the porous composite electrodes are Ni-YSZ. At elevated temperature, GDC conducts both oxygen ions and small polarons. The present process uses chemical potential to drive the process. Electrochemical oxidation of CO proceeds within the composite anode and H 2 O reduction proceeds within the composite cathode. At high temperature (e.g., T > 700 °C), GDC has significant electronic leakage in the form of a reduced-cerium small polaron, which supports the charge-transfer reactions. In a typical electrolyzer or fuel cell, this leakage is significantly problematic. However, the present process depends on the leakage current to complete the electrochemical circuit. Model development and validation is based on measured material properties and reactor performance. Potential applications include using CO-rich blast-furnace off gases in steel processing, producing separated streams of H 2 and CO 2 .

Zhu, Huayang↗

A Full-Cell Model for Direct Toluene Electro-Hydrogenation Electrolysis

Liquid organic hydrogen carriers (LOHCs) are organic molecules that undergo a hydrogenation/dehydrogenation cycle to enable storage and transportation of hydrogen fuel under ambient conditions. One promising LOHC candidate is toluene, which can be converted to methylcyclohexane (MCH) electrochemically, enabling a decarbonized process when green electricity is used. In this study, we developed a full-cell model for the direct electro-hydrogenation of toluene to MCH, utilizing a zero-gap membrane electrode assembly architecture. The model incorporates electrochemical kinetics, ionic transport, water transport across the membrane, and mass transport effects. Electrochemical kinetics are characterized using Tafel analysis on Pt/Ru catalyst. The model is validated against experimental data, including polarization curves, Faradaic efficiencies, and water crossover. A voltage breakdown analysis shows that the performance is dominated by kinetic losses, and the model is used to carry out a comparison of different toluene electro-hydrogenation reaction catalysts. Finally, a sensitivity analysis is conducted on key design parameters illustrating which can be modified to maximize electrolyzer performance. The cathode specific surface area and cathode porous transport layer thickness (PTL) have the largest impact on the current density, while the PTL thickness and Pt loading in the PTL have the largest impact on Faradaic efficiency.

Ehlinger, Victoria M. [Lawrence Livermore National↗

Mathematical Modeling of the Potential and Time Dependence of Ir Dissolution from Hydrous Ir Oxide Oxygen Evolution Catalysts

One of the main degradation mechanisms of hydrous iridium oxide acidic oxygen evolution reaction (OER) catalysts is dissolution and loss into the acidic membrane. While degradation models have been proposed, there is a gap in understanding the potential and time dependence of the iridium dissolution reaction and its mechanistic underpinnings. In this work, Ir dissolution rates measured as a function of time and potential via time-resolved inductively-coupled plasma mass spectrometry (ICP-MS) in aqueous acidic electrolyte are used to establish a mathematical model for Ir dissolution. The mathematical model is generated using proposed formation and dissolution reactions for Ir species. Through comparison with the ICP-MS data and existing information on the potential-dependent Ir phase, we find that the potential and time-dependence of dissolution can be modeled as dissolution of an oxide phase, here represented as IrO 2 , with potential dependent kinetics and formation of a passivating species, a process with a rate-limiting step that is not potential dependent. This understanding of the potential dependence of dissolution and passivation kinetics using aqueous electrolyte half-cell measurements can be used to predict the degradation of Ir oxide in operating energy conversion devices relying on the OER, such as proton-exchange membrane water electrolyzers.

Kariuki, Nancy N. [Argonne National Laboratory (AN↗

Quantifying Sources of Long-Term Voltage Decay for Rutile Iridium Oxide Anodes in Proton Exchange Membrane Water Electrolysis

To achieve aggressive hydrogen cost targets for proton exchange membrane water electrolysis (PEMWE), it is necessary to develop catalyst systems that reduce precious metal loadings while maintaining performance over extended operation. While amorphous iridium (Ir) -based catalysts exhibit high initial activity, their long-term stability remains a key limitation. In this study, the behavior of a rutile IrO2 catalyst is investigated over 4000 h of durability testing and compared to past efforts evaluating a more amorphous material. This study finds that rutile IrO2 results in a smaller decay rate (4.9 ..mu..V h-1) than an amorphous catalyst (28 ..mu..V h-1); additionally, the rutile IrO2 results in a smaller degree of Ir migration (20% to the membrane and cathode) than an amorphous catalyst (35%). This research emphasizes rutile IrO2 as a promising avenue for the development of durable, low-iridium anodes that can meet lifetime and cost targets for next-generation electrolyzer systems.

08 HYDROGEN↗

The Impact of Catalyst Layer Properties and Transport Layer Interactions on Rutile Iridium Oxide Anode Durability in Proton Exchange Membrane Electrolysis

The performance and durability of proton exchange membrane electrolyzers are governed by the interplay between catalyst inks and integration, the resulting catalyst layer (CL) structure, and the interface between the CL and porous transport layer (PTL). In this study, we examine the impact of these factors on cell performance and degradation using rutile IrO2 as the anode catalyst. The two commercial rutile IrO2 catalysts differ from each other and from the amorphous benchmark in agglomerate size and ink stability. This has implications for CL morphology and electronic connectivity. In the context of long-term pressurized operation for up to 1000 h, the selection of the PTL has a marginal effect on the durability of CLs with good structural and compositional properties, whereas poorly structured CLs demonstrate evident degradation when used with certain PTLs. Poor CL properties amplify the negative impact of non-ideal CL/PTL interfaces, demonstrating the importance of CL/PTL interface engineering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reports From The Frontier: Overcoming Limitations for Pure-water Anion-exchange-membrane Electrolysis

Anion-exchange-membrane electrolysis is positioned to play a key role in the predicted exponential growth of green hydrogen technology with essential R&D advances. We reveal key design parameters essential to commercialization. First, stable alkaline oxygen-evolution reaction catalysts with high electronic conductivity and minimal surface reconstruction during operation must be designed. Alkaline catalyst layers must also be applied to the membrane electrode assembly with scalable, industrially relevant techniques. Second, ionomer oxidation mitigation strategies must be developed. Furthermore, this approach could also target other creative catalyst layer design, such as phase-separation control to protect oxidation-prone organic components or catalyst engineering to direct selectivity for hydroxide over polymer oxidation. If competitive efficiency and durability can be achieved in pure water, AEM electrolysis has the potential to become a dominant electrolyzer technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

(Invited) Continuum Mathematical Modeling of Water Electrolysis: A Tutorial

Widespread use of hydrogen energy is contingent on the development of reliable and economical sources of hydrogen. Electrolysis from renewably-derived low-carbon electricity is a potentially viable method of hydrogen generation. Prime among the electrolysis technologies are those utilizing ion-conducting polymers (ionomers) including proton-exchange-membrane water electrolyzer (PEMWE). However, these technologies need to exhibit increased efficiency, performance, and durability to become commercially viable. Like most electrochemical devices, PEMWEs involve multiple components (e.g., catalyst, ionomer, transport layers, membrane, plates) and multiple phases, with phenomena occurring across different time and length scales. Furthermore, it is difficult to experimentally probe many of the species and phenomena during operation. Thus, mathematical modeling at the continuum level has been an invaluable aid in exploring, understanding, and optimizing PEMWE cell and components. Furthermore, this is especially true in the highly coupled and complex physics and chemistries that occur with the membrane-electrode assembly (MEA). The physics in a typical volume-averaged non-isothermal model include multiphase transport in porous media, concentrated-solution theory, Ohm's Law, and Butler-Volmer kinetics, and ion, gas, and water transport in the ionomer.

Dizon, Arthur↗

Caltalyst Layer Crack Detector, or CLCD ("clicked") [SWR-20-60]

The Caltalyst Layer Crack Detector, or CLCD ("clicked") is a program that takes in optical micrographs of catalyst coatings for PEM fuel cells or electrolyzers and calculates the percent area that consist of cracks. It does so using a custom algorithm that searches for dark features larger than the background graininess of the catalyst layer.

Pfeilsticker, Jason↗

RODeO (Revenue Operation and Device Optimization Model) [SWR 20-67]

The Revenue, Operation, and Device Optimization (RODeO) model explores optimal system design and operation considering different levels of grid integration, equipment cost, operating limitations, financing, and credits and incentives. RODeO is a price-taker model formulated as a mixed-integer linear programming (MILP) model in the GAMS modeling platform. The objective is to maximizes the net revenue for a collection of equipment at a given site. The equipment includes generators (e.g., gas turbine, steam turbine, solar, wind, hydro, fuel cells, etc.), storage systems (batteries, pumped hydro, gas-fired compressed air energy storage, long-duration systems, hydrogen), and flexible loads (e.g., electric vehicles, electrolyzers, flexible building loads). The input data required by RODeO can be classified into three bins: 1) utility service data, which refers to retail utility rate information (meter cost, energy and demand charges), 2) electricity market data, which include energy and reserve prices, 3) other inputs, which refer to additional electrical demand, product output demand, technological assumptions, financial properties, and operational parameters.

Guerra Fernandez, Omar Jose↗

HOMP (Hybrid Operation and Maintenance Platform) [SWR-22-81]

The HOMP software module is contained within NREL's Hybrid Optimization and Performance Platform (HOPP) at this URL: https://github.com/NREL/HOPP/tree/feature/HOMP. HOMP is a python-based software module which can be used concurrently with the Hybrid Optimization and Performance Platform (HOPP) to model, simulate, and optimize degradation, reliability, and operations and maintenance of hybrid power plant components. The program currently models lithium ion battery, PEM electrolyzer, wind turbine, and solar PV array components, which enables users to understand the design and operation tradeoffs of hybrid power plants. For instance, HOMP enables users to answer questions like: how large does a battery bank need to be to achieve optimal charge/discharge rates for performance and reliability? How does plant design change for different objectives (e.g., profit versus resilience)? Under what conditions is it better to produce electricity versus hydrogen? How do we optimally control hybrid power plants to reduce downtime and increase performance?

Clark, Caitlyn↗

Platinum Group Metals Global Economics Market Supply

Due to uncertainty in the transition away from internal combustion engines (and more importantly, the catalytic convertors these automobiles use), there is large uncertainty in the future of the PGM market. However, proton exchange membrane (PEM) electrolyzers could be a new demand application for PGMs. Therefore, a model was developed which utilizes the system dynamics approach to predict supply and prices for specific demand scenarios. Results indicated that the total PGM market value sees a decline in the late 2020s due to changing automotive application demand. Market decline was due to decreasing internal combustion engine (ICE) vehicle demand resulting in less PGMs supplied for automotive applications. Compounding market decline was an increase in secondary supply of PGMs as more ICE automotives reach their EOL pushing PGM prices down as secondary supply increases while demand simultaneously decreases. Following the market decline, an increase in market value in the early 2030s was observed due to deployment of hydrogen fuel cell technologies and subsequent increase in PGM demand

Kulkarni, Sameer (0000000227573592)↗