Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Innovative signal processing for Johnson Noise thermometry

This report summarizes the newly developed algorithm that subtracted the Electromagnetic Interference (EMI). The EMI performance is very important to this measurement because any interference in the form on pickup from external signal sources from such as fluorescent lighting ballasts, motors, etc. can skew the measurement. Two methods of removing EMI were developed and tested at various locations. This report also summarizes the testing performed at different facilities outside Oak Ridge National Laboratory using both EMI removal techniques. The first EMI removal technique reviewed in previous milestone reports and therefore this report will detail the second method.

97 MATHEMATICS AND COMPUTING↗

Search for the Higgs and Physics Beyond the Standard Model with the CMS Electromagnetic Calorimeter

The Compact Muon Solenoid (CMS) Experiment is a general purpose particle detector experiment at the Large Hadron Collider (LHC) at the European Laboratory for Nuclear Research (CERN). The LHC is the world’s highest energy particle collider, providing proton-proton collisions up to a center-of-mass energy of 13 TeV. The primary aim of the LHC and the CMS Experiment is to discover new physics at this high energy frontier. In 2012, the discovery of the Higgs boson at the LHC marked a crucial milestone in the Standard Model (SM) of particle physics and ushered in the beginning of a new era of exploration at the high energy frontier. Since this discovery, two key areas of study were the characterization of the new particle to confirm that it is, indeed, the predicted SM Higgs boson and also the examination of possible deviations from the SM that may hint at new physics. As a member of the CMS collaboration, the main interest of PI Orimoto has been the study of electromagnetic objects (electrons and photons) as a critical ingredient in the characterization of the Higgs boson, and as a window into physics beyond-the-SM (BSM). To this end, the Orimoto group has led numerous physics analyses ranging from SM Higgs boson studies, searches for exotic production and decay of the Higgs boson, as well as searches for supersymmetric particles. Moreover, the Orimoto group has made significant contributions to the CMS electromagnetic calorimeter (ECAL), the sub-detector responsible for the precise measurement of the energies of electrons and photons. The Orimoto group’s contributions have been recognized with many leadership roles and high profile conference presentations. This report outlines the group’s products and accomplishments from the award period (June 2013 through July 2018).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Panoramic View of Temperature and Field Distributions of the Structured Catalyst Under Microwave Irradiation Using Experimental and Modeling Approaches

This is a presentation covers NETL's recent research outcome in numerical modeling of microwave-assisted catalytic reaction. In this presentation, the intrinsic microwave-material interaction was demonstrated in this study through numerical modeling and experimental measurement. Different material combinations and reactor setups were investigated and compared. By combining numerical modeling with advanced measurement techniques, the microwave-material interaction and the relationship between electromagnetic field and heating can be better understood, which further benefits the development of microwave-assisted reactors and their application in process intensification.

Bai, Xinwei↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

The Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavour violating conversion of negative muons into electrons in the coulomb field of an Al nucleus, planning to reach a single event sensitivity of about $3\cdot10^{−17}$, four orders of magnitude beyond the current best limit.The conversion electron has a clear monoenergetic signature at 104.967 MeV, slightly below the muon rest mass, and will be identified by a complementary measurement carried out by a high-resolution tracker and an electromagnetic calorimeter (EMC). The calorimeter is composed of 1348 pure CsI crystals, each read by two custom UV-extended SiPMs, that are arranged in two annular disks. The EMC should achieve better than 10% energy resolution and 500 ps timing resolution for 100 MeV electrons and maintain extremely high levels of reliability and stability and in a harsh operating environment with high vacuum, 1 T B-field and radiation exposures up to 100 krad and $10^{12} \rm{n}_\rm{1MeVeq}/\rm{cm}^{2}$.The calorimeter technological choice, along with the design of the custom front-end electronics, cooling and mechanical systems were validated through an electron beam test on a large-scale 51-crystals prototype (Module-0) and extensive test campaigns that characterised and verified the performance of crystals, photodetectors, analogue and digital electronics. This included hardware stress tests and irradiation campaigns with neutrons, protons, and photons.The production and QC phases of all calorimeter components is completed apart for the digital electronics that has been revised for improving its resilience to SEU and SEL. A series of vertical slice tests with the final electronics is being carried out on the Module-0 at LNF along with the implementation and validation of the calibration procedures. The first disk has been assembled in 2022 while the second disk is under assembly at the moment of writing. Status of construction will be summarised, along with plans for commissioning and first calibration of the fully assembled disks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Policy-Driven Sustainable Saline Drainage Disposal and Forage Production in the Western San Joaquin Valley of California

Environmental policies to address water quality impairments in the San Joaquin River of California have focused on the reduction of salinity and selenium-contaminated subsurface agricultural drainage loads from westside sources. On 31 December 2019, all of the agricultural drainage from a 44,000 ha subarea on the western side of the San Joaquin River basin was curtailed. This policy requires the on-site disposal of all of the agricultural drainage water in perpetuity, except during flooding events, when emergency drainage to the River is sanctioned. The reuse of this saline agricultural drainage water to irrigate forage crops, such as ‘Jose’ tall wheatgrass and alfalfa, in a 2428 ha reuse facility provides an economic return on this pollutant disposal option. Irrigation with brackish water requires careful management to prevent salt accumulation in the crop root zone, which can impact forage yields. The objective of this study was to optimize the sustainability of this reuse facility by maximizing the evaporation potential while achieving cost recovery. This was achieved by assessing the spatial and temporal distribution of the root zone salinity in selected fields of ‘Jose’ tall wheatgrass and alfalfa in the drainage reuse facility, some of which have been irrigated with brackish subsurface drainage water for over fifteen years. Electromagnetic soil surveys using an EM-38 instrument were used to measure the spatial variability of the salinity in the soil profile. The tall wheatgrass fields were irrigated with higher salinity water (1.2–9.3 dS m -1 ) compared to the fields of alfalfa (0.5–6.5 dS m -1 ). Correspondingly, the soil salinity in the tall wheatgrass fields was higher (12.5 dS m -1 –19.3 dS m -1 ) compared to the alfalfa fields (8.97 dS mm -1 –14.4 dS mm -1 ) for the years 2016 and 2017. Better leaching of salts was observed in the fields with a subsurface drainage system installed (13–1 and 13–2). The depth-averaged root zone salinity data sets are being used for the calibration of the transient hydro-salinity computer model CSUID-ID (a one-dimensional version of the Colorado State University Irrigation Drainage Model). This user-friendly decision support tool currently provides a useful framework for the data collection needed to make credible, field-scale salinity budgets. In time, it will provide guidance for appropriate leaching requirements and potential blending decisions for sustainable forage production. This paper shows the tie between environmental drainage policy and the role of local governance in the development of sustainable irrigation practices, and how well-directed collaborative field research can guide future resource management.

54 ENVIRONMENTAL SCIENCES↗

Origin of Pulsed Radio Emission from Magnetars

Extended periods of radio pulsations have been observed for six magnetars, displaying characteristics different from those of ordinary pulsars. In this Letter, we argue that radio emission is generated in a closed, twisted magnetic flux bundle originating near the magnetic pole and extending beyond 100 km from the magnetar. The electron–positron flow in the twisted bundle has to carry electric current and, at the same time, experiences a strong drag from the radiation field of the magnetar. This combination forces the plasma into a “radiatively locked” state with a sustained two-stream instability, generating radio emission. We demonstrate this mechanism using novel first-principles simulations that follow the plasma behavior by solving the relativistic Vlasov equation with the discontinuous Galerkin method. First, using one-dimensional simulations, we demonstrate how radiative drag induces the two-stream instability, sustaining turbulent electric fields. When extended to two dimensions, the system produces electromagnetic waves, including superluminal modes capable of escaping the magnetosphere. We measure their frequency and emitted power and incorporate the local simulation results into a global magnetospheric model. The model explains key features of the observed radio emission from magnetars: its appearance after an X-ray outburst, wide pulse profiles, luminosities ∼10 30 erg s −1 , and a broad range of frequencies extending up to ∼100 GHz.

Astronomical simulations↗

Large-scale synthesis, characterization and microwave absorption properties of carbon nanotubes of different helicities

Carbon nanotubes of high helicity (H-HCNTs, Sample A) have been synthesized in large-scale by pyrolysis of acetylene at 450 deg. C over Fe nanoparticles derived from coprecipitation/hydrogen reduction method. With controlled introduction of hydrogen during acetylene pyrolysis, CNTs of low helicity (L-HCNTs, Sample B) and worm-like CNTs (Sample C) were obtained in large quantities. The yields of the CNTs products are high, especially that of H-HCNTs (ca. 7474%). The complex permittivity and permeability of Composites A, B, and C that contain Samples A, B and C (30 wt%) were measured in the 2-18 GHz frequency range. Good absorption of electromagnetic wave (reflection loss<-20 dB) was observed in the 7.18-10.68 and 7.5-10.7 GHz range over Composites B and C (2.0-3.0 mm thickness), respectively. Thus, through the suggested route, CNTs can be produced easily and selectively in large quantities. The lightweight materials can be utilized for microwave absorption. - Graphical abstract: FESEM image of Sample B and reflection loss versus frequency of Composite B (containing 30 wt% of Sample B) in the range of 2-18 GHz.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microwave remote sensing for atmospheric chemistry

Microwave remote sensing is a well-established technique for making sensitive thermal emission measurements at microwave frequencies. This thermal emission described by Planck’s law is the electromagnetic radiation at microwave wavelengths intrinsically emitted from hot objects. This is the blackbody radiation that constitutes the microwave baseline signal. The transitions between quantized rotational states of the constituent gas species gives rise to spectral features on top of this background signal. A distribution of the atmospheric constituents is retrieved from the measured emission lineshape correlated to pressure broadening as a function of altitude. Thus microwave radiometers enable the detection and continuous monitoring of trace gases present in the atmosphere. Microwave radiometers are deployed at various sites around the world measuring an assortment of species and meteorological parameters of interest. Several groups worldwide are active in this field, NRL remote sensing division and the Institute of Physics at the University of Bern among the prominent few. The technology is quite mature with the availability of room temperature RF components at W–band frequencies.

58 GEOSCIENCES↗

Report of METL Mutual Inductance Level Sensor Development for Use in Liquid Metals – FY2023

A robust mutual inductance level sensor (MILS) for use in high temperature liquid metals has been developed at Argonne National Laboratory (ANL). The current design utilizes mineral insulated cables with a 300-series stainless steel sheath, magnesium oxide insulation, and a single copper conductor. Two coils are wrapped on a common core made of a 300-series stainless steel tube. One coil is energized with an alternating current (AC) source, and this electromagnetically couples with the second coil to generate an induced voltage. The voltage is measured to determine the mutual induction between the coils, and the mutual inductance measurement can be used to determine the level of a nearby liquid metal volume. The MILS can be located in an isolating thimble that is fully sealed to a vessel containing liquid metal for ease of maintenance and replacement. When the primary coil is energized with the AC source, the coil not only electromagnetic (EM) couples with the second coil, but also the surrounding liquid metal. The EM coupling with the surrounding liquid metal reduces the EM coupling with the second coil, producing an inverse-linear relationship between liquid metal level and secondary coil voltage. This has all been demonstrated at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at ANL. The most current iteration of the MILS system is the MILS-MK-II. This sensor system has been commissioned in a non-sodium test stand where calibrations were performed using a sodium analog. The calibrations proved to be highly linear and repeatable. The MILS-MK-II has been installed in the METL expansion tank where high temperature sodium tests have been performed. The MILS-MK-II has been calibrated against a known standard at temperature of 300°C, and the calibrations have proved to be highly linear and repeatable. The calibrated MILS-MK-II has been in operation in the METL facility for several thousands of hours at temperatures around 300°C. The experimental data has been used to develop and validate electromagnetic finite element models in COMSOL Multiphysics, and now these models can be used to advance the development of the sensor system. Next steps will include temperature compensation to allow for operation at various temperatures. Additionally, efforts to incorporate a self-calibration methodology are underway.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Compton scattering cross section at a few GeV electron energy

Electron Compton scattering is the best known fundamental QED process, however, a precision measurement of its cross section for a beam energy above 1 GeV has been lacking up to now. An updated high precision measurement of the neutral pion lifetime via the Primakoff effect (PrimEx-II) experiment was performed in Hall B of Jefferson Lab in 2010. The experiment used small angle coherent photoproduction of π 0 ’s in the Coulomb field of a nucleus, i:e: the Primakoff effect, to determine the lifetime with a precision of less than 1:5% . It therefore requires thorough understanding of the underlying systematic uncertainties. To facilitate that data for well known electromagnetic processes were taken concurrently with the photoproduction data. This analysis pertains to measuring the Compton scattering cross section, which occurs with similar kinematics to the primary process. The combination of the well established theory for this process with large collected statistics allowed to extract this cross section with high precision in an energy region of 4-5 GeV for 12 C and 28 Si targets. The results of this analysis will be presented.

Ye, Li↗

Damage detection technique by measuring laser-based mechanical impedance

This study proposes a method for measurement of mechanical impedance using noncontact laser ultrasound. The measurement of mechanical impedance has been of great interest in nondestructive testing (NDT) or structural health monitoring (SHM) since mechanical impedance is sensitive even to small-sized structural defects. Conventional impedance measurements, however, have been based on electromechanical impedance (EMI) using contact-type piezoelectric transducers, which show deteriorated performances induced by the effects of a) Curie temperature limitations, b) electromagnetic interference (EMI), c) bonding layers and etc. This study aims to tackle the limitations of conventional EMI measurement by utilizing laser-based mechanical impedance (LMI) measurement. The LMI response, which is equivalent to a steady-state ultrasound response, is generated by shooting the pulse laser beam to the target structure, and is acquired by measuring the out-of-plane velocity using a laser vibrometer. The formation of the LMI response is observed through the thermo-mechanical finite element analysis. The feasibility of applying the LMI technique for damage detection is experimentally verified using a pipe specimen under high temperature environment.

42 ENGINEERING↗

Doppler Spectrometry for Ultrafast Temporal Mapping of Density Dynamics in Laser-Induced Plasmas

We present high resolution measurements of the ultrafast temporal dynamics of the critical surface in moderately overdense, hot plasma by using two-color, pump-probe Doppler spectrometry. Our measurements clearly capture the initial inward motion of the plasma inside the critical surface of the pump laser which is followed by outward expansion. The measured instantaneous velocity and acceleration profiles are very well reproduced by a hybrid simulation that uses a 1D electromagnetic particle-in-cell simulation for the initial evolution and a hydrodynamics simulation for the later times. The combination of high temporal resolution and dynamic range in our measurements clearly provides quantitative unraveling of the dynamics in this important region, enabling this as a powerful technique to obtain ultrafast snapshots of plasma density and temperature profiles for providing benchmarks for simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte-Carlo Analysis of the Accuracy of a Novel Thomson Scattering Lidar Approach for Determination of the Electron Temperature in Fusion Plasmas

The accuracy of a novel Thomson scattering lidar approach for determination of the electron temperature in fusion plasmas is investigated by statistical Monte-Carlo modeling of the measurement process. The approach is based on the unambiguous temperature dependence of the ratio of the signal powers of two wide Thomson scattering spectral regions. It is shown that the accuracy of the novel approach is comparable with those of the center-of-mass wavelength approach we have developed recently and the commonly used fitting approach. Thus, such an approach would be advantageous by the possibility of using essentially simpler hardware consisting of only two receiving spectral channels.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact Analysis of High-Altitude Electromagnetic Pulse Coupling Effects on Power Grid Protection Relays

Protection relays are important equipment used for protection, control, and metering functions in the power grid. These relays are used to protect critical and difficult-to-replace equipment, like generators, transformers, and capacitor banks. Once the protection devices are disturbed or damaged, a high risk of power generation interruption occurs. Therefore, it is important and necessary to study the relay’s immunity to electromagnetic pulse (EMP) events. As a preliminary step toward empirical experimentation on actual equipment, this manuscript outlines an economical and efficient methodology for evaluating the impact of an EMP. An impedance measurement strategy was employed to model the equipment, setting the stage for subsequent immunity analyses. These analyses included the pulse current injection (PCI) method, which utilized an injecting probe to introduce the transient, and frequency domain electromagnetic (FEKO) simulation, which integrated electromagnetic coupling effects into the transient simulation. The impedance measurement and simulation results in this paper provide a reliable basis for gauging equipment performance in the face of HEMP threats. The results obtained using the PCI and FEKO simulations demonstrated the performance of different port responses under a high-altitude EMP, indicating the requirement for some protection to ensure the reliable operation of relays.

42 ENGINEERING↗

A Technique for Estimating Liquid Droplet Diameter and Liquid Water Content in Stratocumulus Clouds Using Radar and Lidar Measurements

This paper describes a technique for estimating the liquid water content (LWC) and a characteristic particle diameter in stratocumulus clouds using radar and lidar observations. The uncertainty in LWC estimate from radar and lidar measurements is significantly reduced once the characteristic particle diameter is known. The technique is independent of the drop size distribution. It is applicable for a broad range of W-band reflectivity Z between -30 and 0 dBZ and all values of lidar backscatter β observations. No partitioning of cloud or drizzle is required on the basis of an arbitrary threshold of Z as in prior studies. A method for estimating droplet diameter and LWC was derived from the electromagnetic simulations of radar and lidar observations. In situ stratocumulus cloud and drizzle probe spectra were input to the electromagnetic simulation. The retrieved droplet diameter and LWC were validated using in situ measurements from the southeastern Pacific Ocean. The retrieval method was applied to radar and lidar measurements from the northeastern Pacific. Uncertainty in the retrieved droplet diameter and LWC that are due to the measurement errors in radar and lidar backscatter measurements are 7% and 14%, respectively. The retrieved LWC was validated using the concurrent G-band radiometer estimates of the liquid water path.

54 ENVIRONMENTAL SCIENCES↗

Variable magnetic field electron spectrometer to measure hot electrons in the range of 50–460 keV

Resonance absorption (RA) occurs when a p-polarized electromagnetic wave, obliquely incident on an inhomogeneous plasma, tunnels past its turning point and resonantly excites an electron plasma wave (EPW) at the critical density. This phenomenon is important, for instance, in the direct drive approach to inertial fusion energy and is a particular example of a wider phenomenon in plasma physics known as mode conversion, which is crucial for heating magnetic fusion devices, such as tokamaks, via RF heating. Direct measurement of these RA-generated EPW accelerated hot electrons, with energy in the range of a few tens to a few hundreds of keV, is a challenging task due to the relatively low deflecting magnetic fields needed. The solution described here is a magnetic electron spectrometer (MES) with a continually changing magnetic field, lower at the entrance of the MES and gradually increasing toward the end, that enables the measurement of a wide spectral range of electrons with energies between 50 and 460 keV. Electron spectra taken in a LaserNetUS RA experiment were acquired from plasmas generated by irradiating polymer targets with the combination of an ~300 ps pulse followed by a series of ten high intensity 50–200 fs duration laser pulses from the ALEPH laser at Colorado State University. In conclusion, the high intensity beam is designed as spike trains of uneven duration and delay pulses in order to modify the RA phenomenon.

47 OTHER INSTRUMENTATION↗

A new approach to calculate the transport matrix in RF cavities

A realistic approach to calculate the transport matrix in RF cavities is developed. It is based on joint solution of equations of longitudinal and transverse motion of a charged particle in an electromagnetic field of the linac. This field is a given by distribution (measured or calculated) of the component of the longitudinal electric field on the axis of the linac. New approach is compared with other matrix methods to solve the same problem. The comparison with code ASTRA has been carried out. Complete agreement for tracking results for a TESLA-type cavity is achieved. A corresponding algorithm will be implemented into the MARS15 code. A realistic approach to calculate the transport matrix in RF cavities is developed. Complete agreement for tracking results with existed code ASTRA is achieved. New algorithm will be implemented into MARS15 code.

43 PARTICLE ACCELERATORS↗