Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Momentum and Heat Flux Measurements in the Exhaust of VASIMR Using Helium Propellant

Electromagnetic thrusters typically use electric and magnetic fields to accelerate and exhaust plasma through interactions with the charged particles in the plasma. The energy required to create the plasma, i.e. ionization energy, is potential energy between the electron and ion. This potential energy is typically lost since it is not recovered as the plasma is exhausted and is known as frozen flow loss. If the frozen flow energy is a small fraction of the total plasma energy, this frozen flow loss may be negligible. However, if the frozen flow energy is a major fraction of the total plasma energy, this loss can severely reduce the energy efficiency of the thruster. Recovery and utilization of this frozen flow energy can improve the energy efficiency of a thruster during low specific impulse operating regimes when the ionization energy is a large fraction of the total plasma energy. This paper quantifies the recovery of the frozen flow energy, i.e. recombination energy, via the process of surface recombination for helium. To accomplish this task the momentum flux and heat flux of the plasma flow were measured and compared to calculated values from electrostatic probe data. This information was used to deduce the contribution of recombination energy to the total heat flux on a flat plate as well as to characterize the plasma conditions. Helium propellant was investigated initially due to its high ionization potential and hence available recombination energy.

Chavers, D. Gregory↗

Measurement of a radial flow profile with eddy current flow meters and deep neural networks

Eddy current flow meters (ECFMs) measure flows of conductive fluids. Recent interest in ECFMs has increased due to applications in advanced nuclear reactors. ECFMs are well suited for such applications, as they can provide non-invasive measurements of flow in fluids that are often difficult to measure. Traditionally, ECFMs are operated using an alternating current at a single frequency, limiting ECFMs to measure average fluid velocities, blockages, or voids. Here, we expand the capabilities of ECFMs by measuring the fluid radial velocity profile of liquid mercury. To accomplish this, we made several ECFM sensitivity measurements at a range of frequencies. Different frequencies vary the electromagnetic skin depth of the device. By adjusting frequencies, we probed the fluid velocity at various radial locations and constructed a flow-velocity profile. The relationship between the ECFM measurements and velocity profile is nonlinear and requires solving an inverse problem. Using electromagnetic finite-element simulations to train a deep neural network (DNN), we created a model that provides a stable general relationship between the sensitivity measurements of an ECFM and the fluid velocity profile. Using ECFM measurements of liquid mercury, our DNN model calculates a flow profile that agrees well with computational fluid dynamics (CFD) simulations. This technique has potential to improve flow monitoring for optimization, safe operation of conductive fluid loops, and/or validating complex CFD models.

47 OTHER INSTRUMENTATION↗

Nuclear matrix elements from direct lifetime or cross-section measurements

The method of simultaneous lifetime and g factor measurements using a plunger device and the RDDS and TDRIV techniques is introduced. Results on lifetimes and hyperfine-interaction parameters for 2{sup +}{sub 1} states in {sup 104-108}Pd, {sup 96,98,104}Ru, and {sup 92,94}Zr, using a plunger device. Another method to obtain electromagnetic matrix elements is direct cross section measurements using NRF. The method is outlined, and some recent results on {sup 76}Se are shown.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dynamic Characterization of Galfenol (Fe81.6Ga18.4)

Galfenol has the potential to transform the smart materials industry by allowing for the development of multifunctional, load-bearing devices. One of the primary technical challenges faced by this development is the very limited experimental data on Galfenol's frequency-dependent response to dynamic stress, which is critically important for the design of such devices. This report details a novel and precise characterization of the constitutive behavior of polycrystalline Galfenol (Fe81.6Ga18.4) under quasi-static (1 Hz) and dynamic (4 to 1000 Hz) stress loadings. Mechanical loads are applied using a high-frequency load frame. Quasi-static minor and major hysteresis loop measurements of magnetic flux density and strain are presented for constant electromagnet currents (0 to 1.1 A) and constant magnetic fields 0 to 14 kA/m (0 to 180 Oe). The dynamic stress amplitude for minor and major loops is 2.88 and 31.4 MPa (418 and 4550 psi), respectively. Quasi-static material properties closely match published values for similar Galfenol materials. Quasi-static actuation responses are also measured and compared to quasi-static sensing responses; the high degree of reversibility seen in the comparison is consistent with published measurements and modeling results. Dynamic major and minor loops are measured for dynamic stresses up to 31 MPa (4496 psi) and 1 kHz, and the bias condition resulting in maximum, quasi-static sensitivity. Eddy current effects are quantified by considering solid and laminated Galfenol rods. Three key sources of error in the dynamic measurements are accounted for: (1) electromagnetic noise in strain signals due to Galfenol's magnetic response, (2) error in load signals due to the inertial force of fixturing, and (3) phase misalignment between signals due to conditioning electronics. For dynamic characterization, strain error is kept below 1.2 percent of full scale by wiring two collocated gauges in series (noise cancellation) and through leadwire weaving. Inertial force error is kept below 0.41 percent by measuring the dynamic force in the specimen using a nearly collocated piezoelectric load washer. The phase response of all conditioning electronics is explicitly measured and corrected for. In general, as frequency is increased, the sensing response becomes more linear because of an increase in eddy currents. As frequency increases above approximately 100 Hz, the elbow in the strain-versus-stress response disappears as the active (soft) regime stiffens toward the passive (hard) regime. Under constant-field conditions, the loss factors of the solid rod peak between 200 and 600 Hz, rather than exhibiting a monotonic increase. Compared to the solid rod, the laminated rod exhibits much slower increases in hysteresis with frequency, and its quasi-static behavior extends to higher frequencies. The elastic modulus of the laminated rod decreases between 100 and 300 Hz; this trend is currently unexplained.

Dynamic sensing↗

Developing novel techniques for readout, calibration and event selection in the NOvA long-baseline neutrino experiment

The NOvA long-baseline neutrino experiment uses a fine-grained, low-Z, fully active detector that offers unprecedented electron neutrino identification capabilities for a detector of its scale. In this award’s proposal, the PI outlined the development and implementation of novel techniques for channel readout, detector calibration, and event reconstruction that make full use of the strengths of the NOvA detector technology. In particular, this included designing custom event reconstruction algorithms that utilize the rich information available in the substructure of hadronic and electromagnetic showers. Exploiting this information provides not only substantial improvement in background rejection for the electron neutrino search but also better shower energy resolution (improving the precision on measured oscillation parameters) and a high-energy electromagnetic calibration source (through neutral pion events). The PI further proposed developing and deploying a new electronics readout scheme compatible with the existing hardware that can reduce near detector event pile-up and can offer powerful timing information to the reconstruction, allowing for cosmic ray muon tagging via track direction determination, among other things. In conjunction with the above, the PI proposed leading the calibration of the NOvA detectors, including characterizing individual electronics channels, correcting for spatial variations across the detector, and establishing absolute event energy scales. All three of these lines of effort have been successfully completed, feeding directly into the NOvA’s recent exciting neutrino oscillation results. The techniques developed under this award are detailed in this final technical report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual polarized receiving steering antenna array for measurement of ultrawideband pulse polarization structure

To measure simultaneously two orthogonal components of the electromagnetic field of nano- and subnano-second duration, an antenna array has been developed. The antenna elements of the array are the crossed dipoles of dimension 5 × 5 cm. The arms of the dipoles are connected to the active four-pole devices to compensate the frequency response variations of a short dipole in the frequency band ranging from 0.4 to 4 GHz. The dipoles have superimposed phase centers allowing measuring the polarization structure of the field in different directions. The developed antenna array is the linear one containing four elements. The pattern maximum position is controlled by means of the switched ultrawideband true time delay lines. Discrete steering in seven directions in the range from −40° to +40° has been realized. The error at setting the pattern maximum position is less than 4°. The isolation of the polarization exceeds 29 dB in the direction orthogonal to the array axis and in the whole steering range it exceeds 23 dB. Measurement results of the polarization structure of radiated and scattered pulses with different polarization are presented as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Millikelvin measurements of permittivity and loss tangent of lithium niobate

Lithium niobate is an electro-optic material with many applications in microwave and optical signal processing, communication, quantum sensing, and quantum computing. In this Letter, we present findings on evaluating the complex electromagnetic permittivity of lithium niobate at millikelvin temperatures. Measurements are carried out using a resonant-type method with a superconducting radio-frequency cavity operating at 7 GHz and designed to characterize anisotropic dielectrics. The relative permittivity tensor and loss tangent are measured at 50 mK with unprecedented accuracy.

36 MATERIALS SCIENCE↗

The structure of the nucleon: Elastic electromagnetic form factors

Precise proton and neutron form factor measurements at Jefferson Lab, using spin observables, have recently made a significant contribution to the unraveling of the internal structure of the nucleon. Accurate experimental measurements of the nucleon form factors are a test-bed for understanding how the nucleon's static properties and dynamical behavior emerge from QCD, the theory of the strong interactions between quarks. There has been enormous theoretical progress, since the publication of the Jefferson Lab proton form factor ratio data, aiming at reevaluating the picture of the nucleon. We will review the experimental and theoretical developments in this field and discuss the outlook for the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searching for Heavy Photons with Detached Verices in the Heavy Photon Search Experiment

The Jefferson Lab Heavy Photon Search (HPS) experiment is searching for a hypothetical massive particle called the heavy photon which could mediate a dark electromagnetic-type force. If heavy photons kinetically mix with Standard Model photons, they may be radiated by electrons scattering from a heavy nucleus and then decay to e+e- pairs. HPS uniquely searches for heavy photons that either decay at the target or a measurable distance after. The experiment utilizes a silicon vertex tracker (SVT) for momentum and vertex reconstruction, together with an electromagnetic calorimeter for measuring particle energies and triggering events. The HPS experiment took its first data during the spring 2015 engineering run using a 1 GeV electron beam incident on a tungsten target and its second data in the spring of 2016 at a beam energy of 2.3 GeV. The 2015 run obtained two days of production data that was used for the first physics results. The analysis of the data was conducted as a blinded analysis by tuning cuts on 10% of the data. This dissertation discusses the displaced vertex search for heavy photons in the 2015 engineering run. It describes the theoretical motivation for looking for heavy photons and provides an overview of the HPS experimental design and performance. The performance details of the experiment are primarily derived from the 2015 engineering run with some discussion from the higher energy running in 2016. This dissertation further discusses the cuts used to optimize the displaced vertex search and the results of the search. The displaced vertex search did not set a limit on the heavy photon but did validate the methodology for conducting the search. Finally, we used the full data set to make projections and guide future analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wireless and chip-less passive radiation sensors for high dose monitoring

The safety of nuclear infrastructures may involve the monitoring of many parameters in harsh environments (high radiation level, high temperature, high pressure,..). If technological solutions exist for transducers part in such environments, the electronic part used in reader is not appropriate and still a challenging task. Well-known solutions to remove the electronic part from the harsh environment consist of connecting the transducer and the reader by long electrical wires or performing ex situ remote sensing. However wires may practically be difficult to implement while ex situ measurements are not compatible with on line monitoring. Wireless and passive sensors working in harsh environments could be an appropriate solution for the remote sensing of critical parameters. Passive sensors without electronics in the sensing unit are available (e.g., SAW sensors) but they suffer from short reading range (typically lower than 10 meters). In order to overcome this range limitation a new class of electromagnetic transducers was developed in the mid-2000's. The operating principle is based on the modification of the properties of high-frequency (>> 1 GHz) passive electromagnetic devices by the quantity to be measured. Based on this principle a wide range of sensing properties can be addressed and a large number of materials can be chosen. Moreover the use of high frequency allows reducing the size of the sensor elements (antenna, transducer) and enhancing the immunity to multi-path. Several principles of RF transducers have been already validated by LAAS-CNRS (e;g; pressure, temperature, stress) as well as radar-based solution for the wireless long-range sensors interrogation. The sensor dosimeter exploit here the known property of Hydrogen-Pressure Dosimeters (HPD) for which the polymer material dehydrogenates under nuclear irradiation. The transducer principle is described. The irradiation will generate the out-gazing (hydrogen) of the polymer inside a micro-chamber. The resulting overpressure leads to the deflection of a silicon membrane which modifies the resonant frequency of the RF resonator. Tests structures have been designed in order to quantify the HDPE out-gazing inside a micro-cavity by measuring the deflection of a boss silicon membrane with a mechanical profiler. A specific set up using interferometry method has been also developed to evaluate the pressure generated inside the micro-cavity. The procedure consists in applying a pressure that pushes the membrane to recover a flat membrane. This condition is monitored thanks to the extinction of the Newton rings. Irradiations have been performed up to 30 kGy using 6 MeV focused e-beam providing by electron accelerator. Membrane deflection and generated pressure around 0.2 μm/mg{sub HDPE}/kGy and 70 mbar/mg{sub HDPE}/kGy has been obtained for a 70 μm thick membrane. In order to characterize the hermetic sealing of the micro-chamber under hydrogen over-pressure, membrane deflection after irradiation has been recorded during 50 days. The variations of membrane deflection are randomly distributed and generally lower than ±5%, showing a good hermeticity during this period. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnosing electric and magnetic fields in laser-driven coil targets

Laser-driven capacitor coils are widely used to generate intense magnetic fields for various applications in high-energy-density (HED) physics research. Accurate measurement of the magnetic fields is essential but challenging, due to the overlapping contributions from magnetic and electric fields in proton radiography, which is the primary tool diagnosing the field generation around the coils. In this study, we systematically analyze proton radiographs obtained from laser-driven capacitor-coil targets along two orthogonal axes under various electromagnetic field conditions, including magnetic field only, electric field only, and combined electromagnetic fields. By analyzing key features in the radiographs, we distinguish and characterize the respective contributions from magnetic and electric fields. Using detailed simulations validated by experimental benchmarks, methods to isolate and quantify the magnetic field and electric field are given. The methods are successfully applied to determine the electric current and charge distribution in a double coil configuration. Our findings provide insights into improving the diagnostic capability of proton radiography, potentially leading to more accurate measurements of electromagnetic fields and enhancing the utility of laser-driven capacitor coils in HED experiments.

electromagnetic field diagnostics↗

Low-loss negative index metamaterials for X, Ku, and K microwave bands

Low-loss, negative-index of refraction metamaterials were designed and tested for X, Ku, and K microwave frequency bands. An S-shaped, split-ring resonator was used as a unit cell to design homogeneous slabs of negative-index metamaterials. Then, the slabs of metamaterials were cut unto prisms to measure experimentally the negative index of refraction of a plane electromagnetic wave. Theoretical simulations using High-Frequency Structural Simulator, a finite element equation solver, were in good agreement with experimental measurements. The negative index of refraction was retrieved from the angle- and frequency-dependence of the transmitted intensity of the microwave beam through the metamaterial prism and compared well to simulations; in addition, near-field electromagnetic intensity mapping was conducted with an infrared camera, and there was also a good match with the simulations for expected frequency ranges for the negative index of refraction.

36 MATERIALS SCIENCE↗

Local field enhancement on metallic periodic surface structures produced by femtosecond laser pulses

Periodic surface structures on aluminium are produced by femtosecond laser pulses for efficient excitation of surface electromagnetic waves using a strong objective (NA = 0.5). The local electromagnetic field enhancement on the structures is measured using the technique of surface-enhanced Raman scattering from pyridine molecules. (extreme light fields and their applications)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Platform development for dE/dx measurements on short-pulse laser facilities

We illustrate generating benchmark data on charged-particle stopping power in dense plasma is a challenge, motivating new experimental platforms for facilities such as short-pulse lasers. We report on several experiments that aimed to develop a platform for high-precision stopping power measurements at OMEGA EP, specifically developing target-normal sheath acceleration (TNSA) sources, proton isochoric heating, and radiatively heated foams. Integrated experiments were performed to measure stopping power, but several phenomena have been identified that would need to be mitigated for a stopping-power measurement, including irreproducibility of the TNSA sources, spurious electromagnetic fields around proton-heated targets, and cross-talk between the source and subject targets. This work provides a basis for potential future work towards mitigating these problems and performing stopping-power measurements, and is also valuable data for general understanding of TNSA and proton isochoric heating experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing the impact of electromagnetic fields on the directed flow of constituent quarks in heavy-ion collisions

It has been proposed that strong electromagnetic fields produced in the early stages of heavy-ion collisions can lead to splitting of the rapidity-odd directed flow of positive and negative hadrons. For light hadrons, the interpretation of such measurements is complicated by the low magnitude of directed flow as well as by ambiguities arising from transported quarks. To overcome these complications, we propose measurements using only hadrons carrying produced quarks (u¯, d¯, s s¯ ). Here, we discuss how to identify the kinematics where such hadrons are produced via the coalescence mechanism and therefore their flow is the sum of the flow of their constituent quarks. With this sum rule verified for certain combinations of hadrons, the expected systematic violation of this rule with increasing electric charge can be measured, which could be a consequence of the electromagnetic fields produced in the collisions. Our approach can be tested with the high statistics data from Phase II of the Beam Energy Scan program at the Relativistic Heavy Ion Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The NOvA Test Beam Program

NOvA is a long-baseline off-axis beam neutrino experiment at Fermilab and Ash River, Minnesota. By measuring νμ \nu_\mu disappearance and νe \nu_e appearance at the 14 kiloton NOvA Far Detector, the experiment is addressing outstanding questions in neutrino physics, including the neutrino mass hierarchy and existence of leptonic CP violation. The NOvA Test Beam program, under deployment at the Fermilab Test Beam Facility, will use a scaled-down NOvA detector to sample beams of tagged electrons, muons, pions, and protons in the momentum range of 0.3 to 2 GeV/c. It will further the NOvA physics reach by precisely measuring the detector's muon energy scale and electromagnetic and hadronic response, and provide real data for detailed studies of particle identification techniques. Ongoing efforts on beamline instrumentation, data acquisition, simulation, momentum reconstruction and particle identification are presented. Implications for the neutrino oscillation measurements are discussed.

Huang, Junting [Texas U.]↗