At least 703 records · Page 39

Nonproportional scintillation response of NaI:Tl to low energy x-ray photons and electrons

Nonproportional response of the scintillation yield of NaI:Tl was measured using highly monochromatic synchrotron irradiation ranging from 9-100 keV. Special attention is paid to the x-ray escape peaks. They provide us additional information about photon response in the range 0.9-12 keV. A rapid variation in the photon response curve is observed near the iodine K-electron binding energy. A dense sampling of data is performed around this energy and that data are used to apply a method, which we call K-dip spectroscopy. This method allows us to derive the electron response curve of NaI:Tl down to energies as low as 30 eV. A comparison of our data with data of others employing different methods is made. Advantages, limitations, and peculiarities of presented techniques and methods are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exotic Physics with ADMX

The Axion Dark Matter Experiment (ADMX) is an axion haloscope intended to search for local dark matter axions through their resonant conversion to microwave photons. As such, it is extremely sensitive to any particle that couples weakly to microwave photons. Preliminary results from a search for scalar chameleons and plans for a search for a two cavity search for hidden sector photons are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlated Electromagnetic Levitation Actuator: A Reaction Sphere Based Attitude Control System

To address problems experienced by current reaction wheels and control moment gyroscopebased attitude control systems (ACS), researchers at NASA’s Marshall Space Flight Center have begun developing a reaction sphere actuator based on correlated electromagnetic levitation that will be immune to destructive bearing friction, momentum saturation, and gimbal lock. The Correlated Electromagnetic Levitation Actuator (CELA) advances the state of the art of reaction sphere ACSs by employing the concept of correlated magnetics. It is a frictionless, direct-drive reaction sphere that harnesses a unique technology with an array of applications across multiple disciplines. Correlated electromagnets function in a manner that is analogous to a matched filter; the convolution of two signals is peaked at the index representing the greatest match. For CELA, the signals are the patterns of magnetic flux density as a function of position. The magnitude of the convolution equates to an attractive or repulsive force, and these forces can be azimuthal or radial. The development of CELA is based in four distinct disciplines: Advanced Manufacturing, Prototype Development, Electromagnetic Modeling, and Controls. We are developing novel manufacturing techniques required to build arrays of permanent and electromagnet dipoles on curved surfaces. To print the permanent magnetic array, we have developed a probe with pyramidal magnets that will reside on a robotic arm to induce localized magnetic fields on a surface. The probe also includes the ability to erase dipole patterns from a permanent magnet by heating the surface to its Curie temperature. A number of test articles and prototypes have been developed using additive manufacturing methods. These prototypes have included hemispherical motors to test the drive algorithm, and a levitation test bed that demonstrates a magnetic bearing method based on attractive magnetic forces and ratiometric Hall effect sensors. We developed an array of electromagnetic dipoles on a printed circuit board (PCB) with individual H-bridges controlling each coil. This device created various flux density patterns and we measured their magnetic fields using a custom Hall effect 3-D probe and a LabVIEW virtual instrument. These data will serve as a benchmark for characterizing the accuracy of future models. Current work is focused on modeling the magnetic fields of our prototype arrays using COMSOL Finite Element Analysis and verifying the model against our test data. Accurate modeling will allow us to quickly test new patterns of electromagnets and their macro behavior. Eventually, the magnetic field models will be implemented in our controls simulations to facilitate precise control of the reaction sphere. Initial model results agree with field measurements to within 1 G (5% of measured flux density). Currently, we are testing different material properties of the electromagnets and their magnetic fields and thermal effects. These results will be used to refine the design of the electromagnetic dipoles. Our control efforts have centered on developing commutation, levitation, and field pattern shaping hardware in the form of breadboards and PCBs with software running on a local microcontroller. In addition, our partners developed MATLAB Simulink models to demonstrate a PID controller thatmitigates disturbance forces resulting from the interaction of drive and levitation magnetics. Finally, we have designed a three-axis test stand that will be used in future work to demonstrate CELA’s orientation control capability.

controls↗

Diffractive Measurements at the LHC: Elastic and Inelastic Soft Diffraction

A short review of four topics was presented: (1) Photon bremsstrahlung in elastic proton-proton scattering, (2) Low mass Single Diffraction (SD), (3) Low mass Central Exclusive Diffraction (CED), and (4) Event classification of the pp interactions at the LHC. This article summarizes topic (1).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE HIGH-ENERGY EMISSION OF THE CRAB NEBULA FROM 20 keV TO 6 MeV WITH INTEGRAL SPI

The SPI spectrometer aboard the International Gamma-Ray Astrophysics Laboratory mission regularly observes the Crab Nebula since 2003. We report on observations distributed over 5.5 years and investigate the variability of the intensity and spectral shape of this remarkable source in the hard X-rays domain up to a few MeV. While single power-law models give a good description in the X-ray domain (mean photon index approx 2.05) and MeV domain (photon index approx 2.23), crucial information is contained in the evolution of the slope with energy between these two values. This study has been carried out through individual observations and long duration (approx 400 ks) averaged spectra. The stability of the emission is remarkable and excludes a single power-law model. The slopes measured below and above 100 keV agree perfectly with the last values reported in the X-ray and MeV regions, respectively, but without indication of a localized break point. This suggests a gradual softening in the emission around 100 keV and thus a continuous evolution rather than an actual change in the mechanism parameters. In the MeV region, no significant deviation from the proposed power-law model is visible up to 5-6 MeV. Finally, we take advantage of the spectroscopic capability of the instrument to seek for previously reported spectral features in the covered energy range with negative results for any significant cyclotron or annihilation emission on 400 ks timescales. Beyond the scientific results, the performance and reliability of the SPI instrument is explicitly demonstrated, with some details about the most appropriate analysis method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultimate intrinsic coercivity samarian-cobalt magnet. An Earth based feasibility study for Space Shuttle missions

Techniques for the electromagnetic containerless reaction of samarium with cobalt for the formation of samarium-cobalt alloys are summarized. The effort expended to reduce and instrument the oxygen partial pressure in the reaction chamber and coolant gas system are described as well as the experiments in which these improvements were shown to be partially effective. A stainless steel glove box capable of being evacuated to low 10 to the -6th torr pressure and refilled with ultra-pure argon was built and installed. Necessary accessories to perform SmCo5 powder preparation, compaction and subsequent encapsulation of the powder inside a hot isostatic pressing cannister were designed, built, and incorporated into the chamber. All accessories were tested for proper functioning inside the chamber. Using the facility, the first batch of densified SmCo5 powder was fabricated to near total density. Analysis of the densified compacts shows that oxygen contamination during fabrication was near zero.

Das, D.↗

SelenITA: A Dual-Spacecraft Lunar Cubesat Mission to Characterize the Near-Surface Electromagnetic Plasma Environment

SelenITA is an international interdisciplinary mission consisting of two CubeSats that will provide the first multi-point measurement in a sustained low lunar orbit. This mission will advance the understanding of spatiotemporal differentiation of the electromagnetic space environment at the Moon in support of Artemis crew and the geosciences. The mission science objectives are to: (1) further constrain the origins of crustal magnetic fields and their applications; (2) determine the nature of plasma interactions with crustal magnetic fields; (3) characterize plasma waves and turbulence at the Moon; (4) characterize the lunar surface potential in all plasma environments; (5) constrain the composition, thermal state, and structure of the lunar upper mantle and crust; (6) characterize the ionizing radiation in lunar orbit; (7) determine the density of the dust exosphere as a function of latitude, longitude, and altitude, including the lunar polar space environment. The measurement requirements include: 3-component vector magnetic field, plasma distribution (flux, energy, density, temperature), energetic particles (protons, electrons, gamma rays), and dust. SelenITA builds on a rich history of electromagnetic plasma observations of the near lunar surface and space environment, and it answers high level science questions with state of the art instruments in a small package.

space weather↗

Correlated Electromagnetic Levitation Actuator: A Reaction Sphere-Based Attitude Control System

To address problems experienced by current reaction wheels and control moment gyroscopebased attitude control systems (ACS), researchers at National Aeronautics and Space Administration’s (NASA’s) Marshall Space Flight Center (MSFC) have begun developing a reaction sphere actuator based on correlated electromagnetic levitation that will be immune to destructive bearing friction, momentum saturation, and gimbal lock. The Correlated Electromagnetic Levitation Actuator (CELA) advances the state of the art of reaction sphere ACSs by employing the concept of correlated magnetics. It is a frictionless, direct-drive reaction sphere that harnesses a unique technology with an array of applications across multiple disciplines. Correlated electromagnets function in a manner that is analogous to a matched filter; the convolution of two signals is peaked at the index representing the greatest match. For CELA, the signals are the patterns of magnetic flux density as a function of position. The magnitude of the convolution equates to an attractive or repulsive force, and these forces can be azimuthal or radial. The development of CELA is based in four distinct disciplines: Advanced Manufacturing, Prototype Development, Electromagnetic Modeling, and Controls. We are developing novel manufacturing techniques required to build arrays of permanent and electromagnet dipoles on curved surfaces. To print the permanent magnetic array, we have developed a probe with pyramidal magnets that will reside on a robotic arm to induce localized magnetic fields on a surface. We have also used high temperature ovens to erase dipole patterns from a permanent magnet by heating the surface to its Curie temperature. A number of test articles and prototypes have been developed using additive manufacturing methods. These prototypes have included hemispherical motors to test the drive algorithm, and a levitation test bed that demonstrates a magnetic bearing method based on attractive magnetic forces and ratiometric Hall effect sensors. We developed an array of electromagnetic dipoles on a printed circuit board (PCB) with individual H-bridges controlling each coil. This device created various flux density patterns and we measured their magnetic fields using a custom Hall effect 3-D probe and a LabVIEW virtual instrument. These data will serve as a benchmark for characterizing the accuracy of future models. Current work is focused on modeling the magnetic fields of our prototype arrays using COMSOL finite element analysis (FEA) and verifying the model against our test data. Accurate modeling will allow us to quickly test new patterns of electromagnets and their macro behavior. Eventually, the magnetic field models will be implemented in our controls simulations to facilitate precise control of the reaction sphere. Initial model results agree with field measurements to within 1 G (5% of measured flux density). Currently, we are testing different material properties of the electromagnets and their magnetic fields and thermal effects. These results will be used to refine the design of the electromagnetic dipoles. Our control efforts have centered on developing commutation, levitation, and field pattern shaping hardware in the form of breadboards and PCBs with software running on a local microcontroller. In addition, our partners developed MATLAB Simulink models to demonstrate a PID controller that mitigates disturbance forces resulting from the interaction of drive and levitation magnetics. Finally, we have designed a three-axis test stand that will be used in future work to demonstrate CELA’s orientation control capability.

reaction sphere↗

SeaWiFS technical report series. Volume 23: SeaWiFS prelaunch radiometric calibration and spectral characterization

Based on the operating characteristics of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS), calibration equations have been developed that allow conversion of the counts from the radiometer into Earth-existing radiances. These radiances are the geophysical properties the instrument has been designed to measure. SeaWiFS uses bilinear gains to allow high sensitivity measurements of ocean-leaving radiances and low sensitivity measurements of radiances from clouds, which are much brighter than the ocean. The calculation of these bilinear gains is central to the calibration equations. Several other factors within these equations are also included. Among these are the spectral responses of the eight SeaWiFS bands. A band's spectral response includes the ability of the band to isolate a portion of the electromagnetic spectrum and the amount of light that lies outside of that region. The latter is termed out-of-band response. In the calibration procedure, some of the counts from the instrument are produced by radiance in the out-of-band region. The number of those counts for each band is a function of the spectral shape of the source. For the SeaWiFS calibration equations, the out-of-band responses are converted from those for the laboratory source into those for a source with the spectral shape of solar flux. The solar flux, unlike the laboratory calibration, approximates the spectral shape of the Earth-existing radiance from the oceans. This conversion modifies the results from the laboratory radiometric calibration by 1-4 percent, depending on the band. These and other factors in the SeaWiFS calibration equations are presented here, both for users of the SeaWiFS data set and for researchers making ground-based radiance measurements in support of Sea WiFS.

Barnes, Robert A.↗

Beam Asymmetries in {pi}{sup 0} Photoproduction on the Proton

Polarization observables, such as the beam asymmetry {Sigma}, are vital to the study of the many N* and {Delta} resonances that decay to the p{pi}{sup 0} final state. Beam asymmetries in {pi}{sup 0} photoproduction off the proton have been determined using the Crystal Barrel CsI(Tl) calorimeter at ELSA, University of Bonn in Germany, in the energy range E{gamma} = 920 to 1680 MeV by analyzing the neutral decay mode {pi}{sup 0{yields}{gamma}{gamma}}. In this experiment, the BaF{sub 2} spectrometer TAPS was placed in the forward direction increasing the solid angle coverage to nearly 4{pi} and serving as a fast trigger. For the first time, these measurements include the most forward angles in {theta}{sub {pi}}{sup 0c{center_dot}m}. Additionally, this analysis provides new data points in the energy range E{gamma} = 1510 to 1680 MeV where few measurements have previously been made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Weak lensing effects in the measurement of the dark energy equation of state with LISA

The Laser Interferometer Space Antenna's (LISA's) observation of supermassive binary black holes (SMBBH) could provide a new tool for precision cosmography. Inclusion of subdominant signal harmonics in the inspiral signal allows for high-accuracy sky localization, dramatically improving the chances of finding the host galaxy and obtaining its redshift. A SMBBH merger can potentially have component masses from a wide range (10{sup 5}-10{sup 8}M{sub {center_dot}}) over which parameter accuracies vary considerably. We perform an in-depth study in order to understand (i) what fraction of possible SMBBH mergers allow for sky localization, depending on the parameters of the source, and (ii) how accurately w can be measured when the host galaxy can be identified. We also investigate how accuracies on all parameters improve when a knowledge of the sky position can be folded into the estimation of errors. We find that w can be measured to within a few percent in most cases, if the only error in measuring the luminosity distance is due to LISA's instrumental noise and the confusion background from Galactic binaries. However, weak lensing-induced errors will severely degrade the accuracy with which w can be obtained, emphasizing that methods to mitigate weak lensing effects would be required to take advantage of LISA's full potential.

79 ASTRONOMY AND ASTROPHYSICS↗

Electromagnetic Simulations of Ground-Penetrating Radar Propagation near Lunar Pits and Lava Tubes

Placing an Orion capsule at the Earth-Moon L2 point (EML2) would potentially enable telerobotic operation of a rover on the lunar surface. The Human Exploration Virtual Institute (HEVI) is proposing that rover operations be carried out near one of the recently discovered lunar pits, which may provide radiation shielding for long duration human stays as well as a cross-disciplinary, science-rich target for nearer-term telerobotic exploration. Ground penetrating radar (GPR) instrumentation included onboard a rover has the potential to reveal many details of underground geologic structures near a pit, as well as characteristics of the pit itself. In the present work we employ the full-wave electromagnetic code MEEP to simulate such GPR reflections from a lunar pit and other subsurface features including lava tubes. These simulations will feed forward to mission concepts requiring knowledge of where to hide from harmful radiation and other environmental hazards such as plama charging and extreme diurnal temperatures.

Lava Tubes↗

Precision measurements of K{sup {+-}} {yields} {pi}{sup {+-}}{pi}{sup 0}{gamma} decay at NA48/2 and search for CP violation

The direct emission (DE) and interference (INT) terms of the radiative decay K{sup {+-}} {yields} {pi}{sup {+-}}{pi}{sup 0}{gamma} have been measured by the NA48/2 experiment at CERN SPS. About 6 10{sup 5} K{sup {+-}} {yields} {pi}{sup {+-}}{pi}{sup 0}{gamma} decays have been selected from data collected during 2003 and 2004. The relative amounts of DE and INT with respect to the dominant Inner Bremsstrahlung (IB) contribution have been measured in the range 0<T{sub {pi}}{sup *}<80 MeV, where T{sub {pi}}{sup *} is the kinetic energy of the charged pion in the kaon rest frame, obtaining: Frac(DE) = (3.32 {+-}0.15{sub stat}{+-}0.14{sub syst})10{sup -2}, Frac(INT) = (-2.35 {+-}0.35{sub stat}{+-}0.39{sub syst}) 10{sup -2}. This is the first observation of an interference term in K{sup {+-}} {yields} {pi}{sup {+-}}{pi}{sup 0}{gamma} decays. From this measurement the DE normalized electric and magnetic amplitudes are derived: X{sub E} = (-24 {+-}6) GeV{sup -4}, X{sub M} = (254 {+-} 9) GeV{sup -4}.In addition, the CP violating asymmetry in the K{sup +} and K- branching ratios for this channel has been determined to be less than 1.5 10{sup -3} at 90% confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interaction between Faraday rotation and Cotton-Mouton effects in polarimetry modeling for NSTX

The evolution of electromagnetic wave polarization is modeled for propagation in the major radial direction in the National Spherical Torus Experiment with retroreflection from the center stack of the vacuum vessel. This modeling illustrates that the Cotton-Mouton effect-elliptization due to the magnetic field perpendicular to the propagation direction-is shown to be strongly weighted to the high-field region of the plasma. An interaction between the Faraday rotation and Cotton-Mouton effects is also clearly identified. Elliptization occurs when the wave polarization direction is neither parallel nor perpendicular to the local transverse magnetic field. Since Faraday rotation modifies the polarization direction during propagation, it must also affect the resultant elliptization. The Cotton-Mouton effect also intrinsically results in rotation of the polarization direction, but this effect is less significant in the plasma conditions modeled. The interaction increases at longer wavelength and complicates interpretation of polarimetry measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using high-intensity laser-generated energetic protons to radiograph directly driven implosions

The recent development of petawatt-class lasers with kilojoule-picosecond pulses, such as OMEGA EP [L. Waxer et al., Opt. Photonics News 16, 30 (2005)], provides a new diagnostic capability to study inertial-confinement-fusion (ICF) and high-energy-density (HED) plasmas. Specifically, petawatt OMEGA EP pulses have been used to backlight OMEGA implosions with energetic proton beams generated through the target normal sheath acceleration (TNSA) mechanism. This allows time-resolved studies of the mass distribution and electromagnetic field structures in ICF and HED plasmas. This principle has been previously demonstrated using Vulcan to backlight six-beam implosions [A. J. Mackinnon et al., Phys. Rev. Lett. 97, 045001 (2006)]. The TNSA proton backlighter offers better spatial and temporal resolution but poorer spatial uniformity and energy resolution than previous D{sup 3}He fusion-based techniques [C. Li et al., Rev. Sci. Instrum. 77, 10E725 (2006)]. A target and the experimental design technique to mitigate potential problems in using TNSA backlighting to study full-energy implosions is discussed. The first proton radiographs of 60-beam spherical OMEGA implosions using the techniques discussed in this paper are presented. Sample radiographs and suggestions for troubleshooting failed radiography shots using TNSA backlighting are given, and future applications of this technique at OMEGA and the NIF are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The performance of the LHCf detector

The LHCf experiment is designed to measure energies and transverse momenta of neutral particles emitted in the forward region of {radical}(s) = 14 TeV p-p collision at {+-}140 m away from the interaction point1 (IP1) of LHC. The energy resolution is confirm to be within 5% and the position resolution is better than 0.2 mm for gamma-rays with energies from 100 GeV to 200 GeV by the test beam results at the CERN-SPS. LHCf has taken data at 2009 and 2010 at {radical}(s) = 900 GeV and 7 TeV collision. A brief summary of LHCf operation at LHC is also reported here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Hidden Sector Photons with the ADMX Detector

Hidden U(1) gauge symmetries are common to many extensions of the standard model proposed to explain dark matter. The hidden gauge vector bosons of such extensions may mix kinetically with standard model photons, providing a means for electromagnetic power to pass through conducting barriers. The axion dark matter experiment detector was used to search for hidden vector bosons originating in an emitter cavity driven with microwave power. We exclude hidden vector bosons with kinetic couplings {chi}>3.48x10{sup -8} for masses less than 3 {mu}eV. This limit represents an improvement of more than 2 orders of magnitude in sensitivity relative to previous cavity experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗