Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

A portable X-pinch design for x-ray diagnostics of warm dense matter

We describe the design and x-ray emission properties (temporal, spatial, and spectral) of Dry Pinch I, a portable X-pinch driver developed at Imperial College London. Dry Pinch I is a direct capacitor discharge device, 300 × 300 × 700 mm3 in size and ∼50 kg in mass, that can be used as an external driver for x-ray diagnostics in high-energy-density physics experiments. Among key findings, the device is shown to reliably produce 1.1 ± 0.3 ns long x-ray bursts that couple ∼50 mJ of energy into photon energies from 1 to 10 keV. The average shot-to-shot jitter of these bursts is found to be 10 ± 4.6 ns using a combination of x-ray and current diagnostics. The spatial extent of the x-ray hot spot from which the radiation emanates agrees with previously published results for X-pinches—suggesting a spot size of 10 ± 6 µm in the soft energy region (1–10 keV) and 190 ± 100 µm in the hard energy region (>10 keV). These characteristics mean that Dry Pinch I is ideally suited for use as a probe in experiments driven in the laboratory or at external facilities when more conventional sources of probing radiation are not available. At the same time, this is also the first detailed investigation of an X-pinch operating reliably at current rise rates of less than 1 kA/ns.

47 OTHER INSTRUMENTATION↗

Preface to the Proceedings of the 23rd Topical Conference on High-Temperature Plasma Diagnostics

Measurements of phenomena advance our understanding of the physical universe. As our understanding grows, more precise measurements are required, as are measurements of new quantities. Diagnosis of a plasma requires developing new instruments, also called diagnostics, as well as new ways to analyze, interpret, synthesize, and correlate their measurements. Further, as computing power increases and multi-physics codes improve their accuracy, more precise measurements are needed to guide future code developments and to validate predictions of these simulation codes. The Topical Conference on High-Temperature Plasma Diagnostics is focused on presenting and documenting the most recent advances in these instrumentation areas for plasmas. The 23rd occurrence of this biennial conference took place on December 14–17, 2020, and was hosted by Los Alamos National Laboratory. Originally scheduled for June 2020 in Santa Fe, New Mexico, the conference was postponed and then held virtually due to the global COVID-19 pandemic. Conference times were adjusted and presentations were scheduled to meet the needs of attendees in Europe, the USA, and Asia.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The phase-2 particle x-ray temporal diagnostic for simultaneous measurement of multiple x-ray and nuclear emission histories from OMEGA implosions (invited)

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as T e is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (~15 ps) scintillator-channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons (DTn) from OMEGA Cryo-DT implosions. High quality data have been collected from warm implosions at OMEGA. These data have been used to infer spatially integrated T e (t) with <10% uncertainty at peak emission. Nuclear and x-ray emission histories are measured with 10 ps relative timing uncertainty for x rays and DTn and 12 ps for x rays and deuterium- 3 He protons (D 3 Hep). A future upgrade to the system will enable spatially integrated T e (t) with 40 ps time-resolution from cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fusion product measurements by nuclear diagnostics in the Joint European Torus deuterium–tritium 2 campaign (invited)

We report a new deuterium–tritium experimental, DTE2, campaign has been conducted at the Joint European Torus (JET) between August 2021 and late December 2021. Motivated by significant enhancements in the past decade at JET, such as the ITER-like wall and enhanced auxiliary heating power, the campaign achieved a new fusion energy world record and performed a broad range of fundamental experiments to inform ITER physics scenarios and operations. New capabilities in the area of fusion product measurements by nuclear diagnostics were available as a result of a decade long enhancement program. These have been tested for the first time in DTE2 and a concise overview is provided here. Confined alpha particle measurements by gamma-ray spectroscopy were successfully demonstrated, albeit with limitations at neutron rates higher than some 10 17 n/s. High resolution neutron spectroscopy measurements with the magnetic proton recoil instrument were complemented by novel data from a set of synthetic diamond detectors, which enabled studies of the supra-thermal contributions to the neutron emission. In the area of escaping fast ion diagnostics, a lost fast ion detector and a set of Faraday cups made it possible to determine information on the velocity space and poloidal distribution of the lost alpha particles for the first time. This extensive set of data provides unique information for fundamental physics studies and validation of the numerical models, which are key to inform the physics and scenarios of ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of an electron cyclotron emission diagnostics suite for COMPASS Upgrade tokamak

COMPASS Upgrade is a medium size and high field tokamak that is capable of addressing key challenges for reactor grade tokamaks, including power exhaust and advanced confinement scenarios. Electron cyclotron emission will be available among the first diagnostics to provide measurements of high spatial and temporal resolution of electron temperature profiles and electron temperature fluctuation profiles through a radial view. A separate oblique view at 12° from normal will be utilized to study non-thermal electrons. Both the radial and oblique views are envisioned to be located in a wide-angle midplane port, which has dimensions that enable simultaneous hosting of the front-end of their quasi-optical (QO) designs. Each QO design will have an in situ hot calibration source in the front-end to provide standalone and calibrated Te (R,t) measurements. The conceptual design for each QO system, the Gaussian beam analysis, and the details of the diagnostic channels are presented.

Instruments & Instrumentation↗

Upgrade of the helically symmetric experiment Thomson scattering diagnostic suite

The Helically Symmetric eXperiment (HSX) Thomson Scattering (TS) diagnostic is being upgraded to decrease uncertainty in electron temperature and density measurements. Upgrades to the HSX TS diagnostic will consist of a novel redesign of polychromator electronics and digitization of the TS output signal. Here, we also present a study of the benefits of an additional spectral channel that will sample the red-shifted band of the scattered spectrum. In conclusion, to maximize system bandwidth (BW) and gain, while minimizing noise, the existing low-BW polychromator electronics on HSX will be replaced by high-BW, high gain circuitry designed in-house.

47 OTHER INSTRUMENTATION↗

Overview and first measurements of the MAST Upgrade bolometer diagnostic

Here, a suite of multi-channel resistive bolometers has been implemented to measure the total radiation from Mega Amp Spherical Tokamak Upgrade plasmas, with cameras covering the core plasma and lower divertor chamber. Data are digitized and processed using novel field-programmable gate array-based electronics, offering improved compactness and new operational capabilities. A synthetic diagnostic has been developed to explore the quality of 2D reconstructions available from the system and to quantify the uncertainty on quantities such as the total radiated power. Measurements in the first campaign have demonstrated correct functioning of the diagnostic while also highlighting issues with electrical noise and some failure mechanisms of the detectors, as well as significant neutral beam fast-particle losses.

47 OTHER INSTRUMENTATION↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

A diagnostic to measure time-resolved atom column density and Doppler temperature in atomic vapors produced by laser ablation

We report on the development of a diagnostic to measure the time-resolved column density and Doppler temperature of atomic vapors produced by laser ablation. The diagnostic is based on the strong frequency dependence of the atomic susceptibility near an electronic transition in the interrogated atomic species. Interference on the face of a fast photodetector between the several frequency components present in a sinusoidally phase-modulated probe beam will produce a time signature uniquely determined by the column density of atoms in the probed atomic state and the Doppler temperature of the atomic vapor. With the extensive, high precision atomic spectroscopy data available in the literature, it is possible to model the vapor and extract the desired parameters through comparison of the model result with the experimental data.

47 OTHER INSTRUMENTATION↗

Design of a 140 GHz waveguide notch filter for millimeter-wave receiver module protection in fusion plasma diagnostics

A carefully designed waveguide-based millimeter-wave notch filter, operating at 140 GHz, safeguards plasma diagnostic instruments from gyrotron leakage. Here, utilizing cylindrical cavity resonators with aperture coupling, the filter efficiently resonates 140 GHz wave-power into the TE 11p mode, optimizing various geometrical parameters for practical fabrication and high-yield production. Thorough thermal analysis ensures its ability to handle power. The filter achieves outstanding performance with over 90 dB rejection at 140 GHz while providing low insertion loss over the passband (110–138 GHz), which is ideally suited for system-on-chip approach F-band diagnostic system applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pop-up Langmuir probe diagnostic in the water cooled divertor of Wendelstein 7-X

The design, development, and successful implementation of pop-up Langmuir probes installed in the water-cooled divertor of W7-X are described. The probes are controlled by drive coils (actuators) installed behind the divertor plates. These drive coils make use of the magnetic field in W7-X to move the probe tips into and out of the plasma. The drive coils were installed in the vacuum vessel after extensively testing the durability of the coils and analyzing the criteria for safe operation. The probe design is carefully tailored for each of the 36 probe tips in order to be suitable for the different magnetic field configurations used in W7-X and ensure that the probes do not present leading edges to the magnetic flux tubes. An electronic bridge circuit is used for measurement to compensate for the effects of signal propagation time on the long cable lengths used. The diagnostic is integrated with the segment control of W7-X for automated operation and control of the diagnostic. The evaluation of the results from the plasma operation is presented after accounting for appropriate sheath expansion for negative bias voltage on the probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward an integrated multi-gigahertz ionizing particle diagnostic

Needs arising at both current and future accelerator facilities call for the development of radiation-hardened position-sensing diagnostics that can operate with multi-GHz repetition rates. Such instruments are likely to also have applications in the diagnosis of rapid plasma behavior. Here, building on the recent work of our Advanced Accelerator Diagnostics Collaboration, we are exploring the development of integrated multi-GHz ionizing particle detection systems based on chemical-vapor deposition diamond sensors, with the initial goal of producing a quadrant detector that can determine the intensity and centroid position of a particle beam at a repetition rate between 5 and 10 GHz. Results from our initial high-speed characterization work are presented, including those from a single-channel sensor with a GHz response. Approaches to achieving multi-GHz (5–10 GHz) rate capability, including the design of a dedicated Application Specific Integrated Circuit and the use of 3D RF-solver computer aided design software, are presented and discussed in more detail. 3D RF simulations suggest clean pulses of duration less than 250 ps (FWHM less than 125 ps) can be achieved with the approaches developed by this work.

43 PARTICLE ACCELERATORS↗

The motional Stark effect diagnostic for ITER

An overview of the plans for the motional Stark effect (MSE) diagnostic installation on the International Thermonuclear Experimental Reactor (ITER) is presented. The MSE diagnostic uniquely provides spatially localized magnetic field measurements inside the plasma. These are used to constrain equilibrium reconstructions to determine q(r), the safety factor as a function of minor radius. Meeting the system requirements to deliver q-profiles and related quantities with the specified radial resolution of 20 points over the minor radius, 10 ms time resolution, and better than 10% accuracy is challenging. MSE systems observe the D/H-α emission near 656.3 nm from neutral beams. As the beam atoms traverse the magnetic field, B⃗, at high velocity, v⃗, they experience a Lorentz electric field, v⃗×B⃗, which causes the spectral emission to be split and polarized due to the Stark effect. Traditional MSE-LP (line polarization) measurements determine the direction of the magnetic field in the observation volume using polarimetric analysis of the detected light. The harsh conditions of ITER are expected to deposit thin films of contaminants on the first mirror, which would alter the polarization state of reflected light significantly. On ITER, the combination of high magnetic field strength and high energy beams makes the Stark spectrum resolution suitable for the determination of the magnetic field magnitude from the line shift, so this approach has been selected. Every aspect of the measurement system must be planned for the burning plasma environment and carefully analyzed ahead of time. Current status and plans for the system are presented.

Instruments & Instrumentation↗

Design of a Thomson scattering diagnostic for the SMall Aspect Ratio Tokamak (SMART)

Here, we describe the design of a Thomson scattering (TS) diagnostic to be used on the SMall Aspect Ratio Tokamak (SMART). SMART is a spherical tokamak being commissioned in Spain that aims to explore positive triangularity and negative triangularity plasma scenarios at a low aspect ratio. The SMART TS diagnostic is designed to operate at high spatial resolution, 6 mm scattering length in the low-field side and 9 mm in the high-field side regions, and a wide dynamic range, electron temperature from 1 eV to 1 keV and density from 5 x 10 18 m -3 to 1 x 10 20 m -3 ⁠, to resolve large gradients formed at the plasma edge and in the scrape-off layer (SOL) under different triangularities and low aspect ratios. A 2 J @1064 nm laser will be used that is capable of operating in the burst mode at 1, 2, and 4 kHz to investigate fast phenomena and at 30 Hz to study 1 s (or more) long discharges. The scattered light will be collected over an angular range of 60° – 120° from 28 spatial points in the midplane covering the entire plasma width and the outer midplane SOL. Each scattering signal will be spectrally resolved on five wavelength channels of a polychromator to obtain the electron temperature measurement. We will also present a method to monitor in situ laser alignment in the core during calibrations and plasma operations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New millimeter-wave diagnostics to locally probe internal density and magnetic field fluctuations in National Spherical Torus Experiment-Upgrade (invited)

A set of new millimeter-wave diagnostics will deliver unique measurement capabilities for National Spherical Torus Experiment-Upgrade to address a variety of plasma instabilities believed to be important in determining thermal and particle transport, such as micro-tearing, global Alfvén eigenmodes, kinetic ballooning, trapped electron, and electron temperature gradient modes. These diagnostics include a new integrated intermediate-k Doppler backscattering (DBS) and cross-polarization scattering (CPS) system (four channels, 82.5–87 GHz) to measure density and magnetic fluctuations, respectively. The system can access reasonably large normalized wavenumbers k θ ρ s ranging from ≤0.5 to 15 (where ion sound gyroradius ρ s = 1 cm and k θ is the binormal density turbulence wavenumber). The system addresses the challenges for making useful DBS/CPS measurements with a remote control of launch polarization (X- or O-mode), probed wavenumber, polarization match of the launch beam with the edge magnetic field pitch angle, and beam steering of the launched beam for wave-vector alignment. In addition, a low-k DBS system consisting of eight fixed frequencies (34–52 GHz) and four tunable frequencies (55–75 GHz) for low-k density turbulence and fast ion physics will be located at a nearby port location. Finally, the combined systems cover the near LCFS and pedestal regions (34–52 GHz), the pedestal or mid-radius (50–75 GHz), and core plasmas (82.5–87 GHz).

47 OTHER INSTRUMENTATION↗

Three-dimensional reconstruction of laser-direct-drive inertial confinement fusion hot-spot plasma from x-ray diagnostics on the OMEGA laser facility (invited)

A deep-learning convolutional neural network (CNN) is used to infer, from x-ray images along multiple lines of sight, the low-mode shape of the hot-spot emission of deuterium–tritium (DT) laser-direct-drive cryogenic implosions on OMEGA. The motivation of this approach is to develop a physics-informed 3-D reconstruction technique that can be performed within minutes to facilitate the use of the results to inform changes to the initial target and laser conditions for the subsequent implosion. The CNN is trained on a 3D radiation-hydrodynamic simulation database to relate 2D x-ray images to 3D emissivity at stagnation. The CNN accounts for the lack of an absolute spatial reference and the different bands of photon energies in the x-ray images. While previous works studied the effect of mode-1 asymmetries on implosion performance using nuclear diagnostics, this work focuses on the effect of mode 2 inferred from x-ray diagnostics on implosion performance. A current analysis of 19 DT cryogenic implosions indicates there is an upper limit of ~20% reduction in the neutron yield caused by an ℓ = 2 amplitude for ℓ 2 /ℓ 0 ≤ 0.32. Here, these conclusions are supported by 2D simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of low temperature spectrometers for the JET high resolution Thomson scattering diagnostic for disruption plasma measurements

This work presents a system upgrade of the High Resolution Thomson Scattering (HRTS) diagnostic on JET that allows it to measure low temperature (1–500 eV) plasma pre- and post-Thermal quench (TQ), which would help us further understand the Shattered Pellet Injection (SPI) physics. The upgrade was done by connecting optic fibers from the original HRTS system to four spectrometers specialized in measuring low temperature plasmas. The upgraded system allows for the measurement of low temperature plasma at up to 12 spatial points, which can be flexibly distributed throughout the JET outer midplane profile during the dedicated SPI experiments. In other JET experiments, four previously unused groups of fibers were used to measure the central plasma to provide disruption data without changing the standard HRTS system. The low temperature Thomson scattering system was installed, commissioned, and cross-calibrated against the standard HRTS diagnostic in a calibration pulse. The system worked reliably during the JET experiments and provided electron density and temperature profiles for pre- and post-TQ low temperature plasmas in the SPI campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a correlation reflectometer radiometer diagnostic and measurements of the electron density–temperature cross-phase angle in the H-mode pedestal with small edge localized modes at ASDEX Upgrade

This work presents the hardware design and first results from a newly commissioned correlation reflectometer radiometer diagnostic that measures the cross-phase angle between electron density and temperature fluctuations in ASDEX Upgrade plasmas. This diagnostic employs cross correlations between signals measured by a tunable, continuous wave, perpendicular incidence, fluctuation reflectometer, and a 24-channel radiometer sharing the same line of sight. Novel measurements in the pedestal of a helium H-mode plasma with small edge localized modes show changes in the cross-phase angle between the electron density and temperature fluctuations from ∼90° to 120°, suggesting changes in the properties of the turbulence driving transport in the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗