Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Atoms-to-devices models for post-irradiation annealing kinetics in III-V semiconductors

Understanding atomic displacement damage and propagating this understanding into validated defect-aware radiation damage models is a critical step toward achieving predictive, atoms-to-systems assessment of radiation vulnerabilities of microelectronics. These models are essential for evaluating the performance and reliability of nuclear stockpile components or space-based electronics (satellites). The goal of this project was to bridge a fundamental science gap between defect spectroscopies and atomistic modeling of radiation-induced defects on the one hand, and simulations of device response on the other hand, to develop predictive defect-aware damage models for high-fidelity device simulations of radiation-damaged III-V semiconductors.

36 MATERIALS SCIENCE↗

Optimize the Autonomous Sensor Fish Device for Understanding Interactions of Aquatic Animals with Marine and Hydrokinetic and Hydro Systems (CRADA 476) Final Report

This project at the Pacific Northwest National Laboratory (PNNL) enhances our understanding of how aquatic life interacts with marine renewable energy (MRE) and hydropower systems through the development and testing of advanced sensor technology. The Marine Sensor Fish (MSF) and its smaller variants, the Sensor Fish Mini (SF Mini) and Flexible Sensor Fish (FSF), measure critical environmental stressors, such as shear forces, pressure changes, and strike impacts, that are essential for assessing the risks posed by energy devices, including tidal turbines, hydropower installations, and other MRE infrastructure. Rigorous field testing has shown that these tools are effective in capturing detailed data on turbulence, pressure variations, strike impacts, and other stressors near these devices, providing valuable insights into the conditions faced by aquatic species. Economically, these tools offer renewable energy developers a practical solution for streamlining environmental assessments and ensuring regulatory compliance, ultimately reducing costs associated with evaluating and mitigating ecological impacts. This research also benefits the public by promoting the growth of renewable energy sources that protect aquatic ecosystems, advancing both sustainable energy production and environmental stewardship.

13 HYDRO ENERGY↗

Sapphire Substrate Trenching to Advance Superconducting High-Coherence Quantum Devices

Achieving longer coherence times in superconducting qubits is essential for advancing quantum information processing and enabling scalable quantum computing. This work presents an innovative fabrication strategy focused on sapphire trenching of the substrate of superconducting high-coherence quantum devices, developed by the SQMS Nanofabrication Taskforce in collaboration with the materials characterization team. In this talk, we present a method to efficiently and consistently trench into the sapphire substrate, without compromising the surface roughness or profile of the etched sapphire. In the literature, trenching in the substrate has been shown to decrease losses, unwanted coupling and thermal stress. Sapphire’s strong covalent bonds make it harder to etch compared to silicon, yet it is more favorable for high-coherence quantum devices due to its lower dielectric losses. This innovative technique opens new possibilities for superconducting qubit fabrication: we fabricated high coherence qubit chips on sapphire substrates with trenching, to demonstrate that it will help pushing towards higher coherence times. By integrating this work with ongoing junction process optimization, design innovation, materials characterization and exploration, we outline a clear pathway toward transmon coherence times reaching millisecond scales and beyond.

Garattoni, S. [Fermilab]↗

Sapphire Substrate Trenching to Advance Superconducting High-Coherence Quantum Devices

Achieving longer coherence times in superconducting qubits is essential for advancing quantum information processing and enabling scalable quantum computing. This work presents an innovative fabrication strategy focused on sapphire trenching of the substrate of superconducting high-coherence quantum devices, developed by the SQMS Nanofabrication Taskforce in collaboration with the materials characterization team. In this talk, we present a method to efficiently and consistently trench into the sapphire substrate, without compromising the surface roughness or profile of the etched sapphire. In the literature, trenching in the substrate has been shown to decrease losses, unwanted coupling and thermal stress. Sapphire’s strong covalent bonds make it harder to etch compared to silicon, yet it is more favorable for high-coherence quantum devices due to its lower dielectric losses. This innovative technique opens new possibilities for superconducting qubit fabrication: we fabricated high coherence qubit chips on sapphire substrates with trenching, to demonstrate that it will help pushing towards higher coherence times. By integrating this work with ongoing junction process optimization, design innovation, materials characterization and exploration, we outline a clear pathway toward transmon coherence times reaching millisecond scales and beyond.

Garattoni, S. [Fermilab]↗

Beamline Device Designators

LAMP is to replace the front-end of LANSCE. Therefore, the device designators for LAMP needs approval from LANSCE. This document defines the agreed upon device designator names to be used in LAMP and in the prototype beamline LAMP in ADEF Tunnel (LAT).

43 PARTICLE ACCELERATORS↗

PLC Integration for the Horn A Magnetic Field Mapping Device

This presentation summarizes the integration of a programmable logic controller (PLC) into the Horn A magnetic field mapping device for the Long-Baseline Neutrino Facility (LBNF). The device is used to position magnetic field probes along the centerline of the Horn A inner conductor to verify that the magnetic field within this region is approximately zero. The presentation covers the PLC hardware and electrical integration, stepper motor and encoder control, ladder logic development, mechanical integration, and system testing. Results include successful bidirectional motion and encoder feedback for the translation and rotation axes, as well as characterization of translational motion for repeatable probe positioning.

Bitakis, Kayla [Unlisted, US, IL]↗

Evaluation of fluxon synapse device based on superconducting loops for energy efficient neuromorphic computing

With Moore’s law nearing its end due to the physical scaling limitations of CMOS technology, alternative computing approaches have gained considerable attention as ways to improve computing performance. Here, we evaluate performance prospects of a new approach based on disordered superconducting loops with Josephson-junctions for energy efficient neuromorphic computing. Synaptic weights can be stored as internal trapped fluxon states of three superconducting loops connected with multiple Josephson-junctions (JJ) and modulated by input signals applied in the form of discrete fluxons (quantized flux) in a controlled manner. The stable trapped fluxon state directs the incoming flux through different pathways with the flow statistics representing different synaptic weights. We explore implementation of matrix–vector-multiplication (MVM) operations using arrays of these fluxon synapse devices. We investigate the energy efficiency of online-learning of MNIST dataset. Our results suggest that the fluxon synapse array can provide ~100× reduction in energy consumption compared to other state-of-the-art synaptic devices. This work presents a proof-of-concept that will pave the way for development of high-speed and highly energy efficient neuromorphic computing systems based on superconducting materials.

42 ENGINEERING↗

First Results from the Thomson Scattering Diagnostic on the Large Plasma Device

We present the first Thomson scattering measurements of electron density and temperature in the Large Plasma Device (LAPD), a 22 m long magnetized linear plasma device at the University of California Los Angeles (UCLA). The diagnostic spectrally resolves the Doppler shift imparted on light from a frequency-doubled Nd:YAG laser when scattered by plasma electrons. A fiber array coupled to a triple-grating spectrometer is used to obtain high stray light rejection and discriminate the faint scattering signal from a much larger background. In the center of the plasma column, the measured electron density and temperature are about ne≈1.5×1013 cm−3 and Te≈ 3 eV, respectively, depending on the discharge parameters and in good agreement with Langmuir probe data. Optical design considerations to maximize photon count while minimizing alignment sensitivity are discussed in detail and compared to numerical calculations. Raman scattering off of a quartz crystal probe is used for an absolute irradiance calibration of the system.

Kaloyan, Marietta (ORCID:0000000182593038)↗

Seismic Waveform Inversion Capability on Resource-Constrained Edge Devices

Seismic full wave inversion (FWI) is a widely used non-linear seismic imaging method used to reconstruct subsurface velocity images, however it is time consuming, has high computational cost and depend heavily on human interaction. Recently, deep learning has accelerated it’s use in several data-driven techniques, however most deep learning techniques suffer from overfitting and stability issues. In this work, we propose an edge computing-based data-driven inversion technique based on supervised deep convolutional neural network to accurately reconstruct the subsurface velocities. Deep learning based data-driven technique depends mostly on bulk data training. In this work, we train our deep convolutional neural network (DCN) (UNet and InversionNet) on the raw seismic data and their corresponding velocity models during the training phase to learn the non-linear mapping between the seismic data and velocity models. The trained network is then used to estimate the velocity models from new input seismic data during the prediction phase. The prediction phase is performed on a resource-constrained edge device such as Raspberry Pi. Raspberry Pi provides real-time and on-device computational power to execute the inference process. In addition, we demonstrate robustness of our models to perform inversion in the presence on noise by performing both noise-aware and no-noise training and feeding the resulting trained models with noise at different signal-to-noise (SNR) ratio values. We make great efforts to achieve very feasible inference times on the Raspberry Pi for both models. Specifically, the inference times per prediction for UNet and InversionNet models on Raspberry Pi were 22 and 4 s respectively whilst inference times for both models on the GPU were 2 and 18 s which are very comparable. Finally, we have designed a user-friendly interactive graphical user interface (GUI) to automate the model execution and inversion process on the Raspberry Pi.

Manu, Daniel (ORCID:0000000154982677)↗

Flexible Magnetic Polymer Composite Substrate with Ba 1.5 Sr 1.5 Z Hexaferrite Particles of VHF/Low UHF Patch Antennas for UAVs and Medical Implant Devices

Our goal is to fabricate flexible magnetic polymer composites as antenna substrates for very high frequency (VHF)/low ultra high frequency (UHF) antennas for unmanned aerial vehicles (UAVs) and medical devices. Magnetodielectric materials, which have permeability (μ) similar to permittivity (ε), have attracted great attention, because they facilitate miniaturization of microwave devices while keeping or enhancing electromagnetic characteristics. Mechanically millled Ba 1.5 Sr 1.5 Co 2 Fe 24 O 41 (Ba 1.5 Sr 1.5 Z) hexaferrite particles were used to increase permeability in the interesting frequency band. The microwave properties of Ba 1.5 Sr 1.5 Z composites were predicted and measured. Hansen’s zero-order analysis of antenna bandwidth and electromagnetic field simulation showed that the hexaferrite-based flexible composite could enhance a bandwidth and achieve the miniaturization of antennas as well. The magnetic antenna substrates can be a good solution to integrate antennas into the UAVs whose dimensions are comparable to or larger than communication wavelength.

36 MATERIALS SCIENCE↗

Dielectrophoresis-Based Positioning of Carbon Nanotubes for Wafer-Scale Fabrication of Carbon Nanotube Devices

In this paper, we report the wafer-scale fabrication of carbon nanotube field-effect transistors (CNTFETs) with the dielectrophoresis (DEP) method. Semiconducting carbon nanotubes (CNTs) were positioned as the active channel material in the fabrication of carbon nanotube field-effect transistors (CNTFETs) with dielectrophoresis (DEP). The drain-source current (IDS) was measured as a function of the drain-source voltage (VDS) and gate-source voltage (VGS) from each CNTFET on the fabricated wafer. The IDS on/off ratio was derived for each CNTFET. It was found that 87% of the fabricated CNTFETs was functional, and that among the functional CNTFETs, 30% of the CNTFETs had an IDS on/off ratio larger than 20 while 70% of the CNTFETs had an IDS on/off ratio lower than 20. The highest IDS on/off ratio was about 490. The DEP-based positioning of carbon nanotubes is simple and effective, and the DEP-based device fabrication steps are compatible with Si technology processes and could lead to the wafer-scale fabrication of CNT electronic devices.

59 BASIC BIOLOGICAL SCIENCES↗

Progress and Application of Halide Perovskite Materials for Solar Cells and Light Emitting Devices

Halide perovskite materials have attracted worldwide attention in the photovoltaic area due to the rapid improvement in efficiency, from less than 4% in 2009 to 26.1% in 2023 with only a nanometer lever photo-active layer. Meanwhile, this nova star found applications in many other areas, such as light emitting, sensor, etc. This review started with the fundamentals of physics and chemistry behind the excellent performance of halide perovskite materials for photovoltaic/light emitting and the methods for preparing them. Then, it described the basic principles for solar cells and light emitting devices. It summarized the strategies including nanotechnology to improve the performance and the application of halide perovskite materials in these two areas: from structure–property relation to how each component in the devices affects the overall performance. Moreover, this review listed the challenges for the future applications of halide perovskite materials.

36 MATERIALS SCIENCE↗

Inactivation of Human Coronavirus by FATHHOME’s Dry Sanitizer Device: Rapid and Eco-Friendly Ozone-Based Disinfection of SARS-CoV-2

The pandemic of SARS-CoV-2/COVID-19 was reported in December 2019 in Wuhan, China. Pertaining to its high transmissibility and wide host adaptability, this unique human coronavirus spread across the planet inflicting 115 million people and causing 2.5 million deaths (as of March 3rd, 2021). Limited or negligible pre-existing immunity to multiple SARS-CoV-2 variants has resulted in severe morbidity and mortality worldwide, as well as a record-breaking surge in the use of medical-surgical supplies and personal protective equipment. In response to the global need for effective sterilization techniques, this study evaluated the virucidal efficacy of FATHHOME’s self-contained, ozone-based dry-sanitizing device, by dose and time response assessment. We tested inactivation of human coronavirus, HCoV-OC43, a close genetic model of SARS-CoV-2, on porous (N95 filtering facepiece respirator/FFR) and nonporous (glass) surfaces. We started our assays with 20 ppm-10 min ozone exposure, and effectively reduced 99.8% and 99.9% of virus from glass and N95 FFR surfaces, respectively. Importantly, the virus was completely inactivated, below the detection limit (over 6-log10 reduction) with 25 ppm-15 min ozone exposure on both tested surfaces. As expected, a higher ozone exposure (50 ppm-10 min) resulted in faster inactivation of HCoV-OC43 with 100% inactivation from both the surfaces, with no residual ozone present after completion of the 5-min post exposure recapture cycle and no measurable increase in ambient ozone levels. These results confirmed that FATHHOME’s device is suitable for rapid decontamination of SARS-CoV-2- from worn items, frequently touched items, and PPE including N95 FFRs, face shields, and other personal items. View Full-Text

59 BASIC BIOLOGICAL SCIENCES↗

Examination of an Electrified Bar Rack Fish Guidance Device for Hydropower Turbines

The potential of hydropower turbines to cause injury or mortality to fish is a concern. To reduce this risk, engineers have begun to develop a conically arranged, cantilevered electrified bar rack (Center Sender). This device is proposed to be mounted within the intake of a turbine, guiding downstream-passing fish towards the center of the turbine where blade velocities are lower and blades are thicker, likely reducing the potential for fish to be injured. A simplified version was installed in a flume for testing with Rainbow trout (Oncorhynchus mykiss) while examining several parameters such as electrification, bar spacing, bar angle, and water velocity. The most effective settings were observed to be a water velocity of 1.0 m s -1 with all bars installed at an angle of 40° with electrification on. Other combinations were still effective but had varying results. A minimal proportion (2.3%) of fish passed at lower velocities with bars electrified and mounted at 20°, suggesting that while it functions well as a guidance device in high-velocity conditions, it performs better as a barrier at lower velocities. The study suggests that the Center Sender has promising potential for reducing the harmful effects of hydropower turbines on fish populations by guiding them away from stressors. Further research is needed, but current results encourage its potential use in hydropower operations.

13 HYDRO ENERGY↗

Pool-Based Tow System for Testing Tethered Hydrokinetic Devices Being Developed to Harvest Energy From Ocean Currents

Abstract The immense potential for ocean current energy harvesting is being actively explored as the push for renewable energy becomes more urgent. This paper demonstrates a tow testing platform built to examine and validate mathematical models related to the performance of tethered, underwater, hydrokinetic devices in development to harvest energy from ocean currents, and presents experimental results illustrating how such a system can be used. The platform has been modularly designed to allow for the testing of various tethered, underwater energy-generation systems, including kite-based systems, coaxial turbines, and duct sails. Previous research on tethered energy-generating systems has primarily been focused on airborne systems. Additionally, the limited experimental research on tethered, underwater energy-generation systems has relied on a rigid rod for mechanical and electrical connections between the test articles and instrumentation. The tow testing platform presented in this paper accomplishes the mechanical and electrical connection through a dual-function tether, featuring internal conductors and an external sheath to support towing loads. The goal of this platform was to enable the emulation of ocean currents, which are largely unidirectional, and to retrofit a regular pool into a cost-effective, adaptable, small-scale tow tank test bed. The capabilities of the system include two-way communication with tethered devices, multiple towing profiles in order to emulate different flow regimes, real-time control, and differential velocities via dual winch operation.

Engineering↗

Multiple-amplifier sensing charged-coupled device: model and improvement of the node removal efficiency

The multiple-amplifier sensing charge-coupled device (MAS-CCD) has emerged as a promising technology for astronomical observation, quantum imaging, and low-energy particle detection due to its ability to reduce the readout time for the same readout noise level compared with its predecessor, the skipper-CCD, by reading out the same charge packet through multiple inline amplifiers. Previous works identified a new parameter in this sensor, called node removal inefficiency (NRI), related to inefficiencies in charge transfer and residual charge removal from the sense node of each amplifier after readout. These inefficiencies can lead to distortions in the measured signals similar to those produced by the charge transfer inefficiencies in standard CCDs. We introduce more details in the mathematical model of the NRI mechanism and provide techniques to quantify its magnitude from the measured data. It also proposes a new operation strategy that significantly reduces its effect with minimal alterations of the timing sequences or voltage settings for the other signals of the sensor. The proposed technique is demonstrated experimentally on a 16-amplifier MAS-CCD. At the same time, the experimental data demonstrate that this approach minimizes the NRI effect to levels comparable with other sources of distortion such as the charge transfer inefficiency in scientific devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring MDSplus data-acquisition software and custom devices

MDSplus is a software tool designed for data acquisition, storage, and analysis of complex scientific experiments. Over the years, MDSplus has primarily been used for data management for fusion experiments. This paper demonstrates that MDSplus can be used for a much wider variety of systems and experiments. We present a step-by-step tutorial describing how to create a simple experiment, manage the data, and analyze it using MDSplus and Python. To this end, a custom example device was developed to be used as the data source. This device was built on an opensource electronic hardware platform, and it consists of a microcontroller and two sensors. We read data from these sensors, store it in MDSplus, and use JupyterLab to visualize and process it. This project and code demo are available on the GitHub site at this URL: https://github.com/santorofer/MDSplusAndCustomeDevices

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Devices and methods for electrochemical liquid phase epitaxy

Electrochemical liquid phase epitaxy (ec-LPE) processes and devices are provided that can form precipitated epitaxial crystalline films or layers on a substrate. The precipitated films may comprise a semiconductor, such as germanium, silicon, or carbon. Dissolution into, saturation within, and precipitation of the semiconductor from a liquid metal electrode (e.g., Hg pool) near an interface region with a substrate yields a polycrystalline semiconductor material deposited as an epitaxial film. Reactor cells for use in an electrochemical liquid phase epitaxy (ec-LPE) device are also provided that include porous membranes to facilitate formation of the precipitated epitaxial crystalline films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗