Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detectors Instrumentation Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Parameter trade-offs for imaging spectroscopy systems

With the advent of the EOS era and of configurable sensors, users of these instruments are faced with the twin problems of specifying data acquisition parameters and extracting desired information from the voluminous data. An application of a system model is made to explore system parameter trade-offs for a model sensor based on the High Resolution Imaging Spectrometer. Radiometric performance was studied, along with the effect on classification accuracy of several system parameters. Using a model scene based on typical agricultural reflectance and atmospheric conditions, the atmosphere and sensor are seen to have significant effects on the mean received signal and noise performance. The effect of random uncorrelated errors in the radiometric calibration of the detector array is seen to degrade system performance, especially in the spectral bands below 1 micron. Accurate pixel-to-pixel relative radiometric calibration and the use of the Image Motion Compensation option are seen to improve classification accuracy, especially at high solar zenith angles. Feature sets chosen from characteristics of the scene performed best overall, but ones chosen based on signal-to-noise ratios were seen to be more robust.

Kerekes, John P.↗

VIIRS-J1 Polarization Narrative

The VIS/NIR bands polarization sensitivity of Joint Polar Satellite Sensor 1 (JPSS1) Visible/Infrared Imaging Radiometer Suite (VIIRS) instrument was measured using a broadband source. While polarization sensitivity for bands M5-M7, I1, and I2 was less than 2.5%, the maximum polarization sensitivity for bands M1, M2, M3, and M4 was measured to be 6.4%, 4.4%, 3.1%, and 4.3%, respectively with a polarization characterization uncertainty of less than 0.3%. A detailed polarization model indicated that the large polarization sensitivity observed in the M1 to M4 bands was mainly due to the large polarization sensitivity introduced at the leading and trailing edges of the newly manufactured VISNIR bandpass focal plane filters installed in front of the VISNIR detectors. This was confirmed by polarization measurements of bands M1 and M4 bands using monochromatic light. Discussed are the activities leading up to and including the instruments two polarization tests, some discussion of the polarization model and the model results, the role of the focal plane filters, the polarization testing of the Aft-Optics-Assembly, the testing of the polarizers at Goddard and NIST and the use of NIST's T-SIRCUS for polarization testing and associated analyses and results.

polarization↗

Spacecraft Alignment Determination and Control for Dual Spacecraft Precision Formation Flying

Many proposed formation flying missions seek to advance the state of the art in spacecraft science imaging by utilizing precision dual spacecraft formation flying to enable a virtual space telescope. Using precision dual spacecraft alignment, very long focal lengths can be achieved by locating the optics on one spacecraft and the detector on the other. Proposed science missions include astrophysics concepts with spacecraft separations from 1000 km to 25,000 km, such as the Milli-Arc-Second Structure Imager (MASSIM) and the New Worlds Observer, and Heliophysics concepts for solar coronagraphs and X-ray imaging with smaller separations (50m-500m). All of these proposed missions require advances in guidance, navigation, and control (GNC) for precision formation flying. In particular, very precise astrometric alignment control and estimation is required for precise inertial pointing of the virtual space telescope to enable science imaging orders of magnitude better than can be achieved with conventional single spacecraft instruments. This work develops design architectures, algorithms, and performance analysis of proposed GNC systems for precision dual spacecraft astrometric alignment. These systems employ a variety of GNC sensors and actuators, including laser-based alignment and ranging systems, optical imaging sensors (e.g. guide star telescope), inertial measurement units (IMU), as well as microthruster and precision stabilized platforms. A comprehensive GNC performance analysis is given for Heliophysics dual spacecraft PFF imaging mission concept.

Virtual Telescope↗

Orbital Path and Spacecraft Attitude Correction for the MODIS Lunar Spatial Characterization

For the Moderate Resolution Imaging Spectroradiometer(MODIS) on the Terra and Aqua platforms, regularlyscheduled lunar observations using spacecraft roll maneuvershave been used extensively for sensor characterization. Whilethe primary purpose of these observations is for radiometriccalibration of the reflective solar bands, they have also beenleveraged for a number of other sensor performance assessments,such as the band-to-band (BBR) and detector-to-detector (DDR)spatial registration. The spatial registration calculations arecomplicated by the fact that the Moon does not move in astraight path across the sensor field-of-view (FOV). This path isdetermined by the relative orbital motion between the spacecraftand the Moon and the instrument attitude error that resultsfrom the roll maneuver. In this work, we develop a correctionfor the MODIS lunar spatial characterization measurements bycalculating the predicted path of the Moon across the sensor FOVusing spacecraft and lunar ephemeris data to model the relativeorbital motion between the spacecraft and the Moon along withspacecraft attitude error data acquired during the roll maneuver.The difference between measured and predicted positions of theMoon in the MODIS FOV can be used to calculate the BBRand DDR results. Since the predicted path across the FOV willbe the same for each band, the BBR results will be minimallyaffected. However, we will show that the along-scan spread inthe DDR can be significantly reduced, which results in a muchgreater consistency throughout the full mission for both Aquaand Terra MODIS.

Truman Wilson↗

Coherent Detector Arrays for Continuum and Spectral Line Applications

This viewgraph presentation reviews the requirements for improved coherent detector arrays for use in continuum and spectral line applications. With detectors approaching fundamental limits, large arrays offer the only path to sensitivity improvement. Monolithic Microwave Integrated Circuit (MMIC) technology offers a straightforward path to massive focal plane millimeter wave arrays: The technology will readily support continuum imagers, polarimeters and spectral line receivers from 30-110 GHz. Science programs, particularly large field blind surveys will benefit from simultaneous observations of hundreds or thousands of pixels 1000 element array is competitive with a cost less than $2M.

instrumentation↗

Multiband selection device

Current science projections for future earth-imaging instruments indicate the need for as many as 25 spectral bands, with bandwidths as narrow as 20 nanometers. The desire for a multiplicity of bands has led researchers to study various spectrally dispersive instrument designs as a means of providing the desired future capability. These instrument designs, however, are costly, complex, and of high technical risk. This paper describes a 'multiband selection device' containing several spectral filters that can be placed at the exit faces of a broadband multiport beam splitter and thereby provide a multiplicity of spectral bands with a high degree of spatial coregistration while utilizing state-of-the-art linear array detectors. Fabrication of the multiband selection device has been successfully accomplished, and the design and test results are described.

Richard, H. L.↗

Landsat Data Continuity Mission

The Landsat Data Continuity Mission (LDCM) is currently under development and is on schedule to launch the 8th satellite in the Landsat series in December of 2012. LDCM is a joint project between the National Aeronautics and Space Administration (NASA) and the United States Geological Survey (USGS). NASA is responsible for developing and launching the flight hardware and on-orbit commissioning and USGS is responsible for developing the ground system and operating the system onorbit after commissioning. Key components of the flight hardware are the Operational Land Imager (OLI), nearing completion by Ball Aerospace & Technologies Corp in Boulder, CO, the Thermal Infrared Sensor (TIRS), being built by NASA's Goddard Space Flight Center and the spacecraft, undergoing integration at Orbital Sciences Corp in Gilbert, Arizona. The launch vehicle will be an Atlas-5 with launch services provided by NASA's Kennedy Space Center. Key ground systems elements are the Mission Operations Element, being developed by the Hammers Corporation, and the Collection Activity Planning Element, Ground Network Element, and Data Processing and Archive System, being developed internally by the USGS Earth Resources Observations and Science (EROS) Center. The primary measurement goal of LDCM is to continue the global coverage of moderate spatial resolution imagery providing continuity with the existing Landsat record. The science goal for this imagery is to monitor land use and land cover, particularly as it relates to global climate change. Together the OLI and TIRS instruments on LDCM replace the ETM+ instrument on Landsat-7 with significant enhancements. The OLI is a pushbroom design instrument where the scanning mechanism of the ETM+ is effectively replaced by a long line of detectors. The OLI has 9 spectral bands with similar spatial resolution to ETM+: 7 of them similar to the reflective spectral bands on ETM+ and two new bands. The two new bands cover (1) the shorter wavelength blue part of the spectrum to help with coastal studies and aerosol analyses/atmospheric correction and (2) an atmospheric water absorption band, where the Earth surface is generally not visible, but Cirrus clouds are, to aid in cloud detection and screening. The radiometry of OLI benefits from improved SNR, dynamic range and quantization. OLI is undergoing system testing with a delivery scheduled for Spring 2011. The TIRS is also a pushbroom design and used QWIPS detectors that require cooling to 43K using a cryocooler. It.has two spectral bands, effectively splitting the ETM+ band 6 in half, that can be used as a split window to aid in atmospheric correction. It has nominally 100 m spatial resolution as opposed to the 60 m of Landsat-7 ETM+: TIRS has commenced integration and test, with a delivery to the spacecraft vendor scheduled for Winter 2011-2012. The Orbital spacecraft currently being integrated for LDCM will have improved capabilities for pointing over previous missions. These capabilities will allow the OLI and TIRS instruments to point off-nadir the equivalent of one WRS-2 path to increase the chances of coverage for high priority targets, particularly in the event of natural disasters. Also, the pointing capability will allow the calibration of the OLI using the sun (roughly weekly), the moon (monthly), stars (during commissioning) and the Earth (at 90 deg from normal orientation, a.k.a., side slither) quarterly. The solar calibration will be used for OLI absolute and relative calibration, the moon for trending the stability of the OLI response, the stars will be used for Line of Sight determination and the side slither will be an alternate OLI and relative gain determination methodology. The spacecraft is scheduled to begin integration with the OLI instrument in Summer 2011. The LDCM data processing and archive system (DPAS), located at USGS EROS, generates the products for distribution to users. Like Landsat-7 this includes an image assessment system for characrizing instrument performance and updating calibration parameters. Products will be generated that include the spectral bands from both instruments, terrain corrected and registered to the geoid. Also, like Landsat-7, data products will be distributed at no charge to the user. The current status and plans of the space and ground segments of the LDCM project will be presented along with performance predictions as available. More detailed information on the two instruments is intended to be presented in separate papers.

Markham, Brian↗

Extrasolar planet detection

This paper discusses the concept of extrasolar planet detection using a large-aperture infared imaging telescope. Coronagraphic stellar apodization techniques are less efficient at infrared wavelengths compared to the visible, as a result of practical limitations on aperture dimensions, thus necessitating additional starlight suppression to make planet detection feasible in this spectral domain. We have been investigating the use of rotational shearing interferometry to provide up to three orders of magnitude of starlight suppression over broad spectral bandwidths. We present a theoretical analysis of the system performance requirements needed to make this a viable instrument for planet detection, including specifications on the interferometer design and telescope aperture characteristics. The concept of using rotational shearing interferometry as a wavefront error detector, thus providing a signal that can be used to adaptively correct the wavefront, will be discussed. We also present the status of laboratory studies of on-axis source suppression using a recently constructed rotational shearing interferometer that currently operates in the visible.

Korechoff, R. P.↗

The Observed On-Orbit Background of the ACIS Instrument of the Chandra X-Ray Observatory

We have analyzed calibration data acquired during the Orbital Activation and Checkout (OAC) phase of the Chandra X-ray Observatory (CXO) mission in order to characterize the background of the Advanced CCD Imaging Spectrometer (ACIS) produced by charged particles and non-cosmic x-rays. The ACIS instrument contains eight Front-Illuminated (FI) CCDs and two Back-Illuminated (BI) CCDs. The FI and BI CCDs exhibit dramatically different responses to enhancements in the particle flux. The FI CCDs show relatively little increase in the overall count rate, typical increases are 1-3 counts/s; the BI CCDs show large excursions to as high as 100 counts/s. The directions of these intervals of enhanced background are highly variable ranging from 100 s to 5000 s. The spatial distribution of these background events is relatively flat across the detectors. The spectral distribution can be characterized by a simple power law. The events produce morphologies which are similar to cosmic x-ray events, so that morphology alone cannot be used as a rejection criterion. We explore the correlation of these times of high background with the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument and archival data from the Advanced Composition Explorer (ACE) satellite. We discuss strategies for observers to identify and exclude times of high background and to model and subtract the background events from their data.

Plucinsky, Paul P.↗

QWIPs, SLS, Landsat and the International Space Station

In 1988 DARPA provided funding to NASA’s Goddard Space Flight Center to support the development of GaAs Quantum Well Infrared Photodetectors (QWIP). The goal was to make a single element photodetector that might be expandable to a two-dimensional array format. Ultimately, this led to the development of a 128 x 128 element array in collaboration with AT&T Bell Labs and Rockwell Science Center in 1990. We continued to develop numerous generations of QWIP arrays most recently resulting in the multi-QWIP focal plane for the NASA-US Geological Survey (USGS) Landsat 8 mission launched in 2013 and a similar instrument on the Landsat 9 mission to be launched in 2020. Toward the end of the Landsat 8 QWIP-based Thermal Infrared Sensor (TIRS) instrument the potential of the newly developed Strained Layer Superlattice (SLS) detector array technology became of great interest to NASA for three primary reasons: 1) higher operating temperature; 2) broad spectral response and; 3) higher sensitivity. We have collaborated extensively with QmagiQ, LLC and Northwestern University to further pursue and advance the SLS technology ever since we started back in 2012. In December of 2018 we launched the first SLS-based IR camera system to the International Space Station on board the Robotic Refueling Mission #3 (RRM3). This paper will describe the evolution of QWIP technology leading to the current development of SLS-based imaging systems at the Goddard Space Flight Center over the past 30 years.

Jhabvala, M.↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope Observatory, the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

Modeling Studies of the MODIS Solar Diffuser Attenuation Screen and Comparison with On-Orbit Measurements

The MODIS instrument relies on solar calibration to achieve the required radiometric accuracy. This solar calibration occurs as the TERRA spacecraft comes up over the North Pole. The earth underneath the spacecraft is still dark for approximately one minute and the sun is just rising over the earth's north polar regions. During this time the sun moves through about 4 degrees, the scan mirror rotates about 19 times and about 50 frames (exposures) are made of the white solar diffuser. For some of MODIS'S bands the brightness of the screen is reduced, to prevent detector saturation, by means of a pinhole screen, which produces approximately 600 pinhole images of the sun within the field of view of any one detector. Previous attempts at creating a detailed radiometric model of this calibration scenario produced intensity variations on the focal planes with insufficient detail to be useful. The current computational approach produces results, which take into account the motion of the sun and the scan mirror and produces variations, which strongly resemble the observed focal plane intensity variations. The computational approach and results and a comparison with actual observational data are presented.

Waluschka, Eugene↗

Satellite Ocean Color Sensor Design Concepts and Performance Requirements

In late 1978, the National Aeronautics and Space Administration (NASA) launched the Nimbus-7 satellite with the Coastal Zone Color Scanner (CZCS) and several other sensors, all of which provided major advances in Earth remote sensing. The inspiration for the CZCS is usually attributed to an article in Science by Clarke et al. who demonstrated that large changes in open ocean spectral reflectance are correlated to chlorophyll-a concentrations. Chlorophyll-a is the primary photosynthetic pigment in green plants (marine and terrestrial) and is used in estimating primary production, i.e., the amount of carbon fixed into organic matter during photosynthesis. Thus, accurate estimates of global and regional primary production are key to studies of the earth's carbon cycle. Because the investigators used an airborne radiometer, they were able to demonstrate the increased radiance contribution of the atmosphere with altitude that would be a major issue for spaceborne measurements. Since 1978, there has been much progress in satellite ocean color remote sensing such that the technique is well established and is used for climate change science and routine operational environmental monitoring. Also, the science objectives and accompanying methodologies have expanded and evolved through a succession of global missions, e.g., the Ocean Color and Temperature Sensor (OCTS), the Seaviewing Wide Field-of-view Sensor (SeaWiFS), the Moderate Resolution Imaging Spectroradiometer (MODIS), the Medium Resolution Imaging Spectrometer (MERIS), and the Global Imager (GLI). With each advance in science objectives, new and more stringent requirements for sensor capabilities (e.g., spectral coverage) and performance (e.g., signal-to-noise ratio, SNR) are established. The CZCS had four bands for chlorophyll and aerosol corrections. The Ocean Color Imager (OCI) recommended for the NASA Pre-Aerosol, Cloud, and Ocean Ecosystems (PACE) mission includes 5 nanometers hyperspectral coverage from 350 to 800 nanometers with three additional discrete near infrared (NIR) and shortwave infrared (SWIR) ocean aerosol correction bands. Also, to avoid drift in sensor sensitivity from being interpreted as environmental change, climate change research requires rigorous monitoring of sensor stability. For SeaWiFS, monthly lunar imaging accurately tracked stability at an accuracy of approximately 0.1% that allowed the data to be used for climate studies [2]. It is now acknowledged by the international community that future missions and sensor designs need to accommodate lunar calibrations. An overview of ocean color remote sensing and a review of the progress made in ocean color remote sensing and the variety of research applications derived from global satellite ocean color data are provided. The purpose of this chapter is to discuss the design options for ocean color satellite radiometers, performance and testing criteria, and sensor components (optics, detectors, electronics, etc.) that must be integrated into an instrument concept. These ultimately dictate the quality and quantity of data that can be delivered as a trade against mission cost. Historically, science and sensor technology have advanced in a "leap-frog" manner in that sensor design requirements for a mission are defined many years before a sensor is launched and by the end of the mission, perhaps 15-20 years later, science applications and requirements are well beyond the capabilities of the sensor. Section 3 provides a summary of historical mission science objectives and sensor requirements. This progression is expected to continue in the future as long as sensor costs can be constrained to affordable levels and still allow the incorporation of new technologies without incurring unacceptable risk to mission success. The IOCCG Report Number 13 discusses future ocean biology mission Level-1 requirements in depth.

Ocean Color↗

Search for soft X-ray emission from SN 1987A with a CCD X-ray imaging spectrometer

The results of soft X-ray observations of SN 1987A over the energy band 0.65-2.0 keV are reported. The upper limits on the soft X-ray flux are inconsistent with an extrapolation of the spectrum measured by the Ginga Satellite to the energy band and require a turnover in the X-ray spectrum between 2 and 4 keV. If this turnover is due to absorption by intervening material, a neutral column density associated with the supernova of at least 2.8 x 10 to the 21st/sq cm is required. The background rate for the Texas Instruments 800 x 800 pixel CCD, measured between 150 and 285 km altitude, was 1.1 counts/sq cm s. The background spectrum has a broad peak at 350 electrons, corresponding to charge deposited in the detector by minimally ionizing particles.

Burrows, D. N.↗

An assessment of AVIRIS data for hydrothermal alteration mapping in the Goldfield Mining District, Nevada

Airborne Visible and Infrared Imaging Spectrometer (AVIRIS) data were acquired over the Goldfield Mining District, Nevada, in September 1987. Goldfield is one of the group of large epithermal precious metal deposits in Tertiary volcanic rocks, associated with silicic volcanism and caldera formation. Hydrothermal alteration consists of silicification along fractures, advanced agrillic and argillic zones further away from veins and more widespread propylitic zones. An evaluation of AVIRIS data quality was performed. Faults in the data, related to engineering problems and a different behavior of the instrument while on-board the U2, were encountered. Consequently, a decision was made to use raw data and correct them only for dark current variations and detector read-out-delays. New software was written to that effect. Atmospheric correction was performed using the flat field correction technique. Analysis of the data was then performed to extract spectral information, mainly concentrating on the 2 to 2.45 micron window, as the alteration minerals of interest have their distinctive spectral reflectance features in this region. Principally kaolinite and alunite spectra were clearly obtained. Mapping of the different minerals and alteration zones was attempted using ratios and clustering techniques. Poor signal-to-noise performance of the instrument and the lack of appropriate software prevented the production of an alteration map of the area. Spectra extracted locally from the AVIRIS data were checked in the field by collecting representative samples of the outcrops.

Carrere, Veronique↗

Photon-Counting Multikilohertz Microlaser Altimeters for Airborne and Spaceborne Topographic Measurements

We consider the optimum design of photon-counting microlaser altimeters operating from airborne and spaceborne platforms under both day and night conditions. Extremely compact Q-switched microlaser transmitters produce trains of low energy pulses at multi-kHz rates and can easily generate subnanosecond pulse-widths for precise ranging. To guide the design, we have modeled the solar noise background and developed simple algorithms, based on Post-Detection Poisson Filtering (PDPF), to optimally extract the weak altimeter signal from a high noise background during daytime operations. Practical technology issues, such as detector and/or receiver dead times, have also been considered in the analysis. We describe an airborne prototype, being developed under NASA's instrument Incubator Program, which is designed to operate at a 10 kHz rate from aircraft cruise altitudes up to 12 km with laser pulse energies on the order of a few microjoules. We also analyze a compact and power efficient system designed to operate from Mars orbit at an altitude of 300 km and sample the Martian surface at rates up to 4.3 kHz using a 1 watt laser transmitter and an 18 cm telescope. This yields a Power-Aperture Product of 0.24 W-square meter, corresponding to a value almost 4 times smaller than the Mars Orbiting Laser Altimeter (0. 88W-square meter), yet the sampling rate is roughly 400 times greater (4 kHz vs 10 Hz) Relative to conventional high power laser altimeters, advantages of photon-counting laser altimeters include: (1) a more efficient use of available laser photons providing up to two orders of magnitude greater surface sampling rates for a given laser power-telescope aperture product; (2) a simultaneous two order of magnitude reduction in the volume, cost and weight of the telescope system; (3) the unique ability to spatially resolve the source of the surface return in a photon counting mode through the use of pixellated or imaging detectors; and (4) improved vertical and transverse spatial resolution resulting from both (1) and (3). Furthermore, because of significantly lower laser pulse energies, the microaltimeter is inherently more eyesafe to observers on the ground and less prone to internal optical damage, which can terminate a space mission prematurely.

Degnan, John J.↗

NOAA-20 VIIRS Thermal Emissive Bands On-Orbit Performance

The VIIRS (Visible Infrared Imaging Radiometer Suite) instrument onboard the NOAA-20 satellite (launched on November 18, 2017) started to collect Earth-view data after its nadir door opened on December 13, 2017. Seven of the VIIRS bands, I4-5 and M12-16 are thermal emissive bands (TEBs), covering a spectral range from 3.6 to 12.5 meters. They began collecting valid data after the cold focal plane assembly (CFPA) cooled down to its nominal operating temperature on January 6, 2018. This paper will present the performance of each TEB, including calibration coefficients, noise equivalent differential temperature (NEdT), on-orbit calibration coefficient estimates from scheduled onboard blackbody warm-up and cool-down (WUCD) data, as well as related telemetry temperatures. Several methods are tested and compared in the WUCD data analysis for estimating the calibration coefficients. Based on the preliminary results, the NEdT of each band is well below the design specification and very close to that of the VIIRS onboard the Suomi National Polar-orbiting Partnership (SNPP) satellite. The detector gains appear stable for bands on the short- and mid-wave infrared CFPA, whereas the detector gains have larger than expected degradation for bands on the long-wave infrared CFPA during the early mission. All TEB-related telemetry temperatures are stable. The on-orbit performance of NOAA-20 VIIRS TEB is compared with VIIRS onboard the SNPP.

Thermal Emissive Bands (TEB)↗

Balloon-based interferometric techniques

A balloon-borne triple-etalon Fabry-Perot Interferometer, observing the Doppler shifts of absorption lines caused by molecular oxygen and water vapor in the far red/near infrared spectrum of backscattered sunlight, has been used to evaluate a passive spaceborne remote sensing technique for measuring winds in the troposphere and stratosphere. There have been two successful high altitude balloon flights of the prototype UCL instrument from the National Scientific Balloon Facility at Palestine, TE (May 80, Oct. 83). The results from these flights have demonstrated that an interferometer with adequate resolution, stability and sensitivity can be built. The wind data are of comparable quality to those obtained from operational techniques (balloon and rocket sonde, cloud-top drift analysis, and from the gradient wind analysis of satellite radiance measurements). However, the interferometric data can provide a regular global grid, over a height range from 5 to 50 km in regions of clear air. Between the middle troposphere (5 km) and the upper stratosphere (40 to 50 km), an optimized instrument can make wind measurements over the daylit hemisphere with an accuracy of about 3 to 5 m/sec (2 sigma). It is possible to obtain full height profiles between altitudes of 5 and 50 km, with 4 km height resolution, and a spatial resolution of about 200 km, along the orbit track. Below an altitude of about 10 km, Fraunhofer lines of solar origin are possible targets of the Doppler wind analysis. Above an altitude of 50 km, the weakness of the backscattered solar spectrum (decreasing air density) is coupled with the low absorption crosssection of all atmospheric species in the spectral region up to 800 nm (where imaging photon detectors can be used), causing the along-the-track resolution (or error) to increase beyond values useful for operational purposes. Within the region of optimum performance (5 to 50 km), however, the technique is a valuable potential complement to existing wind measuring systems and can provide a low cost addition to powerful active (LIDAR) wind measuring systems now under development.

Rees, David↗