Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data acquisition systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

CO (Carbon Monoxide Mixing Ratio System) Handbook

The main function of the CO instrument is to provide continuous accurate measurements of carbon monoxide mixing ratio at the ARM SGP Central Facility (CF) 60-meter tower (36.607 °N, 97.489 °W, 314 meters above sea level). The essential feature of the control and data acquisition system is to record signals from a Thermo Electron 48C and periodically calibrate out zero and span drifts in the instrument using the combination of a CO scrubber and two concentrations of span gas (100 and 300 ppb CO in air). The system was deployed on May 25, 2005.

54 ENVIRONMENTAL SCIENCES↗

Monte Carlo simulation of the data acquisition chain of scintillation detectors

The good performance of a detector can be strongly affected by the instrumentation used to acquire the data. The possibility of anticipating how the acquisition chain will affect the signal can help in finding the best solution among different set-ups. In this work we developed a Monte Carlo code that aims to simulate the effect of the various components of a digital Data Acquisition system (DAQ) applied to scintillation detectors. The components included in the model are: the scintillator, the photomultiplier tube (PMT), the signal cable and the digitizer. We benchmarked the code against real data acquired with a NE213 scintillator, comparing simulated and real signal pulses induced by gamma-ray interaction. Then we studied the dependence of the energy resolution of a pulse height spectrum (PHS) on the sampling frequency and the bit resolution of the digitizer. We found that exceeding some values of the sampling frequency and the bit resolution improves only marginally the performance of the system. The method can be applied for the study of various detector systems relevant for nuclear techniques, such as in fusion diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Limits on Subcritical Reactivity Determination using Rossi-α and Related Methods

The subcritical reactivity, ρ, of a neutron multiplying system is of interest to many factions of the nuclear community. The subcritical reactivity in a nuclear system can be inferred from measurements of the prompt neutron decay constant, α. Near critical, the reactivity is linearly proportional with α, but the linearity between these quantities does not hold in systems with low multiplication or significantly above prompt critical. This work examines a large range of subcritical prompt neutron decay constant measurements on a thermal HEU metal system. This system is designed to mimic a solution system and to have the optimal H/ 235 U ratio to minimize the critical mass. The reactivity of these measurements varies between 0$\$$ and 70$\$$ below critical. In addition to experimental measurements on the thermal system, simulations are performed on both the thermal HEU system and a fast HEU metal system. Both the fast and thermal results are compared to baseline simulations performed using criticality eigenvalue (KCODE) mode in MCNP®6.2. These simulations are used for comparisons on the linearity between α and ρ. Prompt neutron decay constant measurements in this work are performed using the Rossi-α method. The measurements are taken using a 3 He neutron detection system and a Los Alamos National Laboratory designed list-mode data acquisition system. A specially designed computer program determines α from list-mode data. The α-eigenvalue, or α at delayed critical, for the thermal HEU system is -199:4±4:4 s -1 as measured during this work. The α-eigenvalue for the fast HEU system was previously measured to be -8:5 x 10 -5 s -1 . The results from the thermal HEU system study suggest that the relationship between ρ and α is linear when k eff > 0:80 based on the simulation results. The experimental results also agree with this result, but have less fidelity. No experimental results are available for the fast HEU system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A sophisticated, multi-channel data acquisition and processing system for high frequency noise research

A sophisticated, multi-channel computerized data acquisition and processing system was developed at the NASA LeRC for use in noise experiments. This technology, which is available for transfer to industry, provides a convenient, cost-effective alternative to analog tape recording for high frequency acoustic measurements. This system provides 32-channel acquisition of microphone signals with an analysis bandwidth up to 100 kHz per channel. Cost was minimized through the use of off-the-shelf components. Requirements to allow for future expansion were met by choosing equipment which adheres to established industry standards for hardware and software. Data processing capabilities include narrow band and 1/3 octave spectral analysis, compensation for microphone frequency response/directivity, and correction of acoustic data to standard day conditions. The system was used successfully in a major wind tunnel test program at NASA LeRC to acquire and analyze jet noise data in support of the High Speed Civil Transport (HSCT) program.

Hall, David G.↗

Undergraduate Measurements For Fission Reactor Applications

Undergraduate students at the University of Dallas (UD) have investigated elastic and inelastic neutron scattering cross sections on structural materials important for criticality considerations in nuclear fission processes. Neutrons scattered off of {sup 23}Na and {sup Nat}Fe were detected using neutron time-of-flight techniques at the University of Kentucky Low-Energy Nuclear Accelerator Facility. These measurements are part of an effort to increase the efficiency of power generation from existing fission reactors in the US and in the design of new fission systems. Students have learned the basics of how to operate the Model CN Van de Graaff generator at the laboratory, setup detectors and electronics, use data acquisition systems, and they are currently analyzing the angular dependence of the scattered neutrons for incident neutron energies of 3.57 and 3.80 MeV. Most students participating in the project will use the research experience as the material for their undergraduate research thesis required for all Bachelor of Science students at the University of Dallas. The first student projects on this topic were completed during the summer of 2010; an overview of student participation in this investigation and their preliminary results will be presented.

99 GENERAL AND MISCELLANEOUS↗

FPGA-based compression of streaming x-ray photon correlation spectroscopy data

A data acquisition system to perform real-time background subtraction and lower-level-discrimination-based compression of streaming x-ray photon correlation spectroscopy (XPCS) data from a fast charge-coupled device (CCD) area detector has been built and put into service at the Advanced Photon source (APS) at Argonne National Laboratory. A commercial frame grabber with on-board field-programmable gate array (FPGA) was used in the design, and continuously processes 60 frames per second each consisting of 1,024 x 1,024 pixels with up to 64512 photon hits per frame.

43 PARTICLE ACCELERATORS↗

Design and operation specifications of an active monitoring system for detecting southern resident killer whales

Before final approval is given to the Snohomish County Public Utility District No. 1 for deploying the first tidal power devices in the United States in an open water environment, a system to manage the potential risk of injury to killer whales due to collision with moving turbine blades must be demonstrated. The Pacific Northwest National Laboratory (PNNL) is tasked with establishing the performance requirements for, constructing, and testing a prototype marine animal alert system for triggering temporary turbine shutdown when there is risk of collision with a killer whale. To develop a system that relies on active sonar two critical areas must be investigated - the target strength of killer whales and the frequency content of commercially available active sonar units. PNNL studied three target strength models: a simple model, the Fourier matching model, and the Kirchoff-ray mode model. Using target strength measurements of bottlenose dolphins obtained by previous researchers and assuming killer whales share similar morphology and structure, PNNL extrapolated the target strength of an adult killer whale 7.5 m in length at a frequency of 67 kHz. To study the frequency content of a commercially available sonar unit, direct measurements of the signal transmitted by the sonar were obtained by using a hydrophone connected to a data acquisition system in both laboratory and field conditions. The measurements revealed that in addition to the primary frequency of 200 kHz, there is a secondary frequency component at 90 kHz, which is within the hearing range of killer whales. The amplitude of the 90-kHz frequency component is above the hearing threshold of killer whales but below the threshold for potential injuries.

16 TIDAL AND WAVE POWER↗

Let’s get our hands dirty: a comprehensive evaluation of DAQDB, key-value store for petascale hot storage

Data acquisition systems are a key component for successful data taking in any experiment. The DAQ is a complex distributed computing system and coordinates all operations, from the data selection stage of interesting events to storage elements. For the High Luminosity upgrade of the Large Hadron Collider, the experiments at CERN need to meet challenging requirements to record data with a much higher occupancy in the detectors. The DAQ system will receive and deliver data with a significantly increased trigger rate, one million events per second, and capacity, terabytes of data per second. An effective way to meet these requirements is to decouple real-time data acquisition from event selection. Data fragments can be temporarily stored in a large distributed key-value store. Fragments belonging to the same event can be then queried on demand, by the data selection processes. Implementing such a model relies on a proper combination of emerging technologies, such as persistent memory, NVMe SSDs, scalable networking, and data structures, as well as high performance, scalable software. In this paper, we present DAQDB (Data Acquisition Database) — an open source implementation of this design that was presented earlier, with an extensive evaluation of this approach, from the single node to the distributed performance. Furthermore, we complement our study with a description of the challenges faced and the lessons learned while integrating DAQDB with the existing software framework of the ATLAS experiment.

Abed Abud, Adam↗

Building a multi-cathode-gas-filled scintillator detector for fission fragments

Radiation cannot be detected directly by human senses, indeed detecting and identifying the fission products or decay yield with high accuracy is a great challenge for experimental physicist. In this work we are building a Multi-Cathode-Gas-filled Scintillator MCGS detector. The detector consists of two parts. First: anode-wire proportional chamber and cathode strip foil, which measure the energy loss of the particles in the gas, due to the ionization, and identifies the position of the products on the detector plane depending on their energy with the presence of a magnetic field. Second: a 7 mm thick scintillator attached to a photomultiplier tube in the back end of the detector. This part measures the rest energy of the particles. A data acquisition system records the events and the particles infonnation. The yields are identified from the energy loss to rest energy ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CMS Event-Builder System for LHC Run 3 (2021-23)

The data acquisition system (DAQ) of the CMS experiment at the CERN Large Hadron Collider (LHC) assembles events of 2MB at a rate of 100 kHz. The event builder collects event fragments from about 750 sources and assembles them into complete events which are then handed to the highlevel trigger (HLT) processes running on O(1000) computers. The aging eventbuilding hardware will be replaced during the long shutdown 2 of the LHC taking place in 2019/20. The future data networks will be based on 100 Gb/s interconnects using Ethernet and Infiniband technologies. More powerful computers may allow to combine the currently separate functionality of the readout and builder units into a single I/O processor handling simultaneously 100 Gb/s of input and output trac. It might be beneficial to preprocess data originating from specific detector parts or regions before handling it to generic HLT processors. Therefore, we will investigate how specialized coprocessors, e.g. GPUs, could be integrated into the event builder. We will present the envisioned changes to the event-builder compared to today’s system. Initial measurements of the performance of the data networks under the event-building trac pattern will be shown. Implications of a folded network architecture for the event building and corresponding changes to the software implementation will be discussed. Corresponding author: remigius.mommsen@cern.c

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advanced Systems for Monitoring Underwater Sounds

The term "Passive Acoustic Monitoring System" (PAMS) describes a developmental sensing-and-data-acquisition system for recording underwater sounds. The sounds (more precisely, digitized and preprocessed versions from acoustic transducers) are subsequently analyzed by a combination of data processing and interpretation to identify and/or, in some cases, to locate the sources of those sounds. PAMS was originally designed to locate the sources such as fish of species that one knows or seeks to identify. The PAMS unit could also be used to locate other sources, for example, marine life, human divers, and/or vessels. The underlying principles of passive acoustic sensing and analyzing acoustic-signal data in conjunction with temperature and salinity data are not new and not unique to PAMS. Part of the uniqueness of the PAMS design is that it is the first deep-sea instrumentation design to provide a capability for studying soniferous marine animals (especially fish) over the wide depth range described below. The uniqueness of PAMS also lies partly in a synergistic combination of advanced sensing, packaging, and data-processing design features with features adapted from proven marine instrumentation systems. This combination affords a versatility that enables adaptation to a variety of undersea missions using a variety of sensors. The interpretation of acoustic data can include visual inspection of power-spectrum plots for identification of spectral signatures of known biological species or artificial sources. Alternatively or in addition, data analysis could include determination of relative times of arrival of signals at different acoustic sensors arrayed at known locations. From these times of arrival, locations of acoustic sources (and errors in those locations) can be estimated. Estimates of relative locations of sources and sensors can be refined through analysis of the attenuation of sound in the intervening water in combination with water-temperature and salinity data acquired by instrumentation systems other than PAMS. A PAMS is packaged as a battery-powered unit, mated with external sensors, that can operate in the ocean at any depth from 2 m to 1 km. A PAMS includes a pressure housing, a deep-sea battery, a hydrophone (which is one of the mating external sensors), and an external monitor and keyboard box. In addition to acoustic transducers, external sensors can include temperature probes and, potentially, underwater cameras. The pressure housing contains a computer that includes a hard drive, DC-to- DC power converters, a post-amplifier board, a sound card, and a universal serial bus (USB) 4-port hub.

Lane, Michael↗

Diamond detector for high rate monitors of fast neutrons beams

A fast neutron detection system suitable for high rate measurements is presented. The detector is based on a commercial high purity single crystal diamond (SDD) coupled to a fast digital data acquisition system. The detector was tested at the ISIS pulsed spallation neutron source. The SDD event signal was digitized at 1 GHz to reconstruct the deposited energy (pulse amplitude) and neutron arrival time; the event time of flight (ToF) was obtained relative to the recorded proton beam signal t{sub 0}. Fast acquisition is needed since the peak count rate is very high ({approx}800 kHz) due to the pulsed structure of the neutron beam. Measurements at ISIS indicate that three characteristics regions exist in the biparametric spectrum: i) background gamma events of low pulse amplitudes; ii) low pulse amplitude neutron events in the energy range E{sub dep}= 1.5-7 MeV ascribed to neutron elastic scattering on {sup 12}C; iii) large pulse amplitude neutron events with E{sub n} < 7 MeV ascribed to {sup 12}C(n,{alpha}){sup 9}Be and 12C(n,n')3{alpha}.

43 PARTICLE ACCELERATORS↗

Detecting anomalous SRF cavity behavior with unsupervised learning

We present an unsupervised learning framework for detecting anomalous superconducting radio-frequency (SRF) cavity behavior at the Continuous Electron Beam Accelerator Facility (CEBAF), emphasizing its initial performance and effectiveness. Key to the system’s success was the development of data acquisition systems (DAQs) that capture fast-sampled, information-rich signals, essential for detecting transient effects. The approach involves creating daily cavity-specific models using principal component analysis to handle variations in rf signal behavior and mitigate performance degradation from data drift. This unsupervised method eliminates the need for expensive labeling by continuously updating models with recent data. Deployed and operational for 3 months before a scheduled shutdown, the system successfully identified several issues with DAQ signals, confirming its effectiveness. Despite access to only a fraction of CEBAF’s SRF cavity signals, the framework efficiently detected several instances requiring intervention, demonstrating a significant improvement over traditional, labor-intensive methods of manual plot inspection. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Misuse Detection for a Generalized SFR Test Reactor

Sodium-cooled Fast Reactors (SFRs) present unique challenges for international safeguards. SFRs possess neutron physics characteristics that if configured appropriately could produce more fissile material than consumed. An adversary state may choose to build an SFR, justified by a lack of domestic natural uranium and limited access or interest to procuring uranium from international markets. Once constructed, the state may choose to misuse the SFR for the purpose of diverting fissile plutonium from declared operation. This work shows that a demonstration SFR does not need to be configured as a plutonium breeder to create one Significant Quantity (SQ) of plutonium in a short amount of time (e.g., one to few years). However, such an extreme case of misuse would change the core reactivity in such a way as to be easily indicated by deviations of control rod position compared to declared operation. In this work a contrived SFR demonstration reactor was modeled for the purpose of exploring proliferation scenarios and how such misuse could be detected using the SFR's Reactor Data Acquisition System (RDAS). Typically, the International Atomic Energy Agency (IAEA) does not have access to the control rod position, power, thermal, pressure sensing and indicating systems of nuclear power plants. However, this work shows that such data streams can be compared against a parallel detailed simulation model (a Digital Twin) to detect possible misuse.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

An Aerial Radiological Survey of Selected Areas of Area 18 - Nevada Test Site

As part of the proficiency training for the Radiological Mapping mission of the Aerial Measuring System (AMS), a survey team from the Remote Sensing Laboratory-Nellis (RSL-Nellis) conducted an aerial radiological survey of selected areas of Area 18 of the Nevada Test Site (NTS) for the purpose of mapping man-made radiation deposited as a result of the Johnnie Boy and Little Feller I tests. The survey area centered over the Johnnie Boy ground zero but also included the ground zero and deposition area of the Little Feller I test, approximately 7,000 feet (2133 meters) southeast of the Johnnie Boy site. The survey was conducted in one flight. The completed survey covered a total of 4.0 square miles. The flight lines (with the turns) over the surveyed areas are presented in Figure 1. One 2.5-hour-long flight was performed at an altitude of 100 ft above ground level (AGL) with 200 foot flight-line spacing. A test-line flight was conducted near the Desert Rock Airstrip to ensure quality control of the data. The test line is not shown in Figure 1. However, Figure 1 does include the flight lines for a ''perimeter'' flight. The path traced by the helicopter flying over distinct roads within the survey area can be used to overlay the survey data on a base map or image. The flight survey lines were flown in an east-west orientation perpendicular to the deposition patterns for both sites. This technique provides better spatial resolution when contouring the data. The data were collected by the AMS data acquisition system (REDAR V) using an array of twelve 2-inch x 4-inch x 16-inch sodium iodide (NaI) detectors flown on-board a twin-engine Bell 412 helicopter. Data, in the form of gamma energy spectra, were collected every second over the course of the survey and were geo-referenced using a differential Global Positioning System. Spectral data allows the system to distinguish between ordinary fluctuations in natural background radiation levels and the signature produced by man-made radioisotopes. Spectral data can also identify specific radioactive isotopes. Based on the results of the RSL NTS 1994 surveys, this area was chosen for a resurvey to improve the spatial resolution of the reported depositions for the Johnnie Boy and Little Feller I events. In addition, the survey was expected to confirm the absence of detectable concentrations of Americium-241 (Am-241) at the Johnnie Boy site and attempt to confirm the presence of Uranium-235 (U-235).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Building energy simulation in real time through an open standard interface

Building energy models (BEMs) are typically used for design and code compliance for new buildings and in the renovation of existing buildings to predict energy use. We present the increasing adoption of BEM as standard practice in the building industry presents an opportunity to extend the use of BEMs into construction, commissioning and operation. In 2009, the authors developed a real-time simulation framework to execute an EnergyPlus model in real time to improve building operation. This paper reports an enhancement of that real-time energy simulation framework. The previous version only works with software tools that implement the custom co-simulation interface of the Building Controls Virtual Test Bed (BCVTB), such as EnergyPlus, Dymola and TRNSYS. The new version uses an open standard interface, the Functional Mockup Interface (FMI), to provide a generic interface to any application that supports the FMI protocol. In addition, the new version utilizes the Simple Measurement and Actuation Profile (sMAP) tool as the data acquisition system to acquire, store and present data. Lastly, this paper introduces the updated architecture of the real-time simulation framework using FMI and presents proof-of-concept demonstration results which validate the new framework.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Telescope Array Radar (TARA) Observatory for Ultra-High Energy Cosmic Rays

Construction was completed during summer 2013 on the Telescope Array RAdar (TARA) bi-static radar observatory for Ultra-High Energy Cosmic Rays (UHECR). TARA is co-located with the Telescope Array, the largest “conventional” cosmic ray detector in the Northern Hemisphere, in radio-quiet Western Utah. TARA employs an 8 MW Effective Radiated Power (ERP) VHF transmitter and smart receiver system based on a 250 MS/s data acquisition system in an effort to detect the scatter of sounding radiation by UHECR-induced atmospheric ionization. TARA seeks to demonstrate bi-static radar as a useful new remote sensing technique for UHECRs. In this report, we describe the design and performance of the TARA transmitter and receiver systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Scalable Online Monitoring System Based on Elasticsearch for Distributed Data Acquisition in Cms

The part of the CMS Data Acquisition (DAQ) system responsible for data readout and event building is a complex network of interdependent distributed applications. To ensure successful data taking, these programs have to be constantly monitored in order to facilitate the timeliness of necessary corrections in case of any deviation from specified behaviour. A large number of diverse monitoring data samples are periodically collected from multiple sources across the network. Monitoring data are kept in memory for online operations and optionally stored on disk for post-mortem analysis. We present a generic, reusable solution based on an open source NoSQL database, Elasticsearch, which is fully compatible and non-intrusive with respect to the existing system. The motivation is to benefit from an off the-shelf software to facilitate the development, maintenance and support efforts. Elasticsearch provides failover and data redundancy capabilities as well as a programming language independent JSON-over-HTTP interface. The possibility of horizontal scaling matches the requirements of a DAQ monitoring system. The data load from all sources is balanced by redistribution over an Elasticsearch cluster that can be hosted on a computer cloud. In order to achieve the necessary robustness and to validate the scalability of the approach the above monitoring solution currently runs in parallel with an existing in-house developed DAQ monitoring system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗